Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC ESD BAIJNATH DISTT KANGRA | KANGRA | HIMACHAL PRADESH | 175013 | ₹4.1 L Quoted ₹4.2 L | L1 | Accepted-AOC awarded on negotiated rates |
| 2 | L2₹4.5 LRejected-Finance GOVT CONTRACTOR VILL GUJREHRA TIKKRI P O TEHSIL JAISINGHPUR DISTT KANGRA H P 176095 | KANGRA | HIMACHAL PRADESH | 176095 | ₹4.5 L | L2 | Rejected-Finance rejected due to higher rates |
| 3 | L2₹4.5 LRejected-Finance | ₹4.5 L | L2 | Rejected-Finance rejected due to higher rates |
Tender Value
₹4.1 L
EMD Value
₹4,065
Closing Date
21 Feb 2026, 10:00 amClosed
Sr. Executive Engineer
o/o Sr. Executive Engineer, Electrical Division, HPSEBL, Baijnath
Tender for restoration of damaged lines due to heavy rain and flood during rainy season at various locations under ESD Baijnath under Electrical Division HPSEBL Baijnath.
2026_HPSEB_128334_1
BED-103/2025-26
Open Tender
Electrical Works
30 days
Baijnath
refer tender docs
3 documents required · 3 mandatory
₹590
₹4,065
18 Mar 2026
12 Feb 2026
21 Feb 2026
12 Feb 2026
21 Feb 2026
12 Feb 2026
Restoration of LT line at E-Section Baijnath-2
Prov. RCC Muff with concrete filling (2000 mm).
Prov. AAAC 7/3.15mm (50 mm sq.) additional 3% (sag,Jumpering wastage}.
Prov. Schackle Insulator
Prov. D-Iron
Prov. M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) {Preferably 16 mm Dia or more}
Erection charges for poles
Erection charges for Conductor
Erection charges for fixing of Jumpers.
Erection charges for LT stay set
GST on Erection
Restoration of LT line at Gankhetar under E-Section Baijnath-1
Prov. AAAC 7/2.50mm (30 mm sq.) additional 3% (sag,Jumpering wastage}.
Erection charges for poles
Erection charges for Conductor
Erection charges for GI wire
GST on Erection
Restoration of LT line at Uttrala & Kandral under section Harer
Prov. RCC Muff with concrete filling (2000 mm).
Prov. LT Stay Set.
Prov. Earthing set
Prov. Schackle Insulator
Prov. D-Iron
Prov. AAAC 7/3.15 mm
Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more}
Prov. Stay Wire 7/3.15 mm
Erection charges for poles
Erection charges for Conductor
Erection charges for GI wire
Erection charges for LT stay set
Erection charges for Earthing set
Erection charges for fixing of Jumpers.
GST on Erection
Restoration of HT line at (location Kandral) in E- section Harer
Prov. S/T Pole 09 Mtr. Long.
Prov. RCC Muff with concrete filling (2000 mm).
Prov. AAAC 7/3.15 mm
Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 90 KN,) i/c Dead end clamps etc.) * (3 Nos. conductors) * (2 Nos. sides).
11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure.
Prov. HT Stay set complete in all respect (1 No/ single pole, 4 no/ double pole structure).
Prov. Egg Insulator
Prov. Stay Wire 7/3.15 mm
Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)].
Prov. Half Clamp (M.S. Flat 50x6 mm).
Prov. Full clamp
Prov. MS Channel iron (100x50x6), Length 2800mm
Prov. MS Channel iron (100x50x6), Length 1800mm
Prov. MS Angle iron (50x50x6), Length 1800mm
Prov. MS Angle iron (50x50x6), Length 2125mm
Erection charges for poles
Erection charges for Conductor
Erection charges for LT stay set
Erection charges for fixing of Jumpers.
GST on Erection
Restoration of HT line at Sarajada in E- section Harer
Prov. S/T Pole 09 Mtr. Long.
Prov. RCC Muff with concrete filling (2000 mm).
Prov.AAAC 7/2.50 mm sq. (30 mm sq.) additional 3% (sag,Jumpering wastage}.
Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 90 KN,) i/c Dead end clamps etc.) * (3 Nos. conductors) * (2 Nos. sides).
11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure.
Prov. HT Stay set complete in all respect (1 No/ single pole, 4 no/ double pole structure).
Prov. Egg Insulator
Prov. Stay Wire 7/3.15 mm
Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)].
Prov. Half Clamp (M.S. Flat 50x6 mm).
Prov. Full clamp
Prov. MS Channel iron (100x50x6), Length 2800mmx2
Prov. MS Angle iron (50x50x6), Length 2800mmx2
Prov. MS Angle iron (50x50x6), Length 2125mmx3
Erection charges for poles
Erection charges for Conductor (30mm2)
Erection charges for LT stay set
Erection charges for fixing of Jumpers.
GST on Erection
Restoration of LT line at E-Section Baijnath-1
Prov. S/T Pole 09 Mtr. Long.
Prov. RCC Muff with concrete filling (2000 mm).
11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure.
Erection charges for poles
Erection charges for Conductor
Erection charges for GI wire
GST on Erection
Restoration of LT line at E-Section Bir
Prov.AAAC 7/3.15 mm sq. (50 mm sq.) additional 3% (sag,Jumpering wastage}.
Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 90 KN,) i/c Dead end clamps etc.) * (3 Nos. conductors) * (2 Nos. sides).
11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure.
Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)].
Prov. Half Clamp (M.S. Flat 50x6 mm).
Prov. MS Channel iron (100x50x6), Length 2800mmx2
Erection charges for fixing of jumpers
Erection charges for Conductor
Erection charges for GI wire
Transportation charges for all works
GST on Erection
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.77 MB
BID-103.pdf
Tender Documents • 1.10 MB
BOQ_189597.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid