Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.0 L+₹5,463 (0.16%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹37.6 L+₹3.6 L (10.7%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to not fulfilling Category b(ii) | |
| 5 | Rejected-Technical INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | - | Rejected-Technical Due to not fulfilling Category b(ii) |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
21 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Bhamre Kiran S
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
REPAIR/MAINTENANCE OF CSS AND CONNECTED WORKS UNDER GE (AF) JAMNAGAR NO. 1.
2021_MES_491310_1
8137/E8
Open Tender
Miscellaneous Works
Item Rate
365 days
Jamnagar
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹68,000
Yes
9 Feb 2022
30 Nov 2021
22 Dec 2021
30 Nov 2021
21 Dec 2021
14 Dec 2021
60 days
Amount
Preventive maintenance for 100-315 KVA compact substation (CSS) which includes general preventive maintenance activities carried out twice in a year and breakdown Maintenance / emergency visit twice in a year Note:- (i) Preventive maintenance shall be carried out one time in every six months (twice in contract period) (ii) Contractor shall be responsible for repairing the CSS and connected items during any breakdown / emergency. (within contract period deemed included in the quoted rates) (iii) Routine testing shall be carried out once in six months. (iv) Contractor shall be responsible for refilling of gas required for CSS (v) the quoted rate shall be inclusive of repairing works like welding / Hinges of CSS both door's
(ii) Contractor shall be responsible for repairing the CSS during any breakdown / emergency.
(iii) Preventive maintenance and routine testing as detailed above.
(iv) Contractor shall also be responsible for refilling of gas required for CSS
Lubrication of mechanical critical parts of circuit breaker shall be done.
Lubrication of spring mechanism shall be carried out.
Checking the movement and interlocks of RMU with VCB & isolator.
Checking of alignment of open cable doors.
Physical healthiness of switches,indication lamp, aux relays.
Busbar tightness , bus joint healthiness checks by torque wrench and contact resistance check.
Any other service point observed
Planning & updating maintenance
CSS testing
Testing of protection relay by secondary injection test.
Routine testing of transformer.
Check the trip operation of the breaker through relay
Primary injection test on CTs.
Contact resistance testing on breaker and bus joints
Ratio check of potential transformer
Checked the open delta voltage ( if applicable)
Megger & HV test
B. Check list for CSS preventive Maintenance :-
(a) Common check point :-
Visual Inspection of CSS
Visual Inspection of side wall of CSS
Earthing pit connection checking
Earthing pit Healthiness verification-ground resistance
Opening and Closing of HT door
Opening and Closing of Metering Door
Opening and Closing of Trafo door -1
Opening and Closing of Trafo door -2
Opening and Closing of LT door
Operation Healthiness HT door limit switch
Operation Healthiness Trfo door limit switch -1- HT tripping /alarm
Operation Healthiness Trafo door limit switch -2- HT tripping / alarm
Operation Healthiness LT door limit switch
(c) Operational checking point of HT panel :-
SF6 gas level indication - position in zone
DC power pack operation healthiness
Battary 24 V DC heathiness
Spring Charging of HT breaker -by manual operation
Spring Charging of HT breaker -by motor operation if available
Closing of breaker by push button
Opening of breaker by push button
Off load Isolater closing and opening
Earthswitch closing and opening checking
Interlock between breaker and off load isolater
Interlock between Earth switch and off load isolater
Interlock of earth switch and BKR cable door
ON load isolater operation of closing and opening by manual
ON load isolater operation of closing and opening by motor if available
ON load isolater earth switch operation
ON load Isolater Interlock of earth switch and cable door
Individual opening and closing of cable door -ON load isolater
Individual opening and closing of cable door -Breaker-3
Earthing tigthness checking of HT Breaker.
Termination Tightness verifiation of all three HT module
Ensure - for proper Gland plate, Cable support , termination boot.
Ensure - cable bushing must be unloaded
Tripping coil health in operation
Remote tripping of HT breaker.
Relay self power battery checking.
Relay trip test operation checking
Reading in measurement checking / healthiness of relay by testing .
VPIS heathiness
Transformer protection Relay working
Earth Fault indicator testing / resetting
All Padlock checking of RMU
(d) Transformer Check Points :-
Visual inspection of transformer
Check oil leakage if oil type
Check oil level in transformer if oil type
Visual inspection of bushing & bolt.
Insulation resistance of Trafo cable
Insulation resistance of Transformer
Tigtness of HT bushing
Tigtness of Bus bar
Transformer earthing
CSS body earthing
Hooter operation healthiness checking
Pressure relief Valve healthiness
Pressure relief Valve and HT tripping/alarm verification if provided
WTI reading verification
WTI operation tripping / alarm checking
OTI reading verification
OTI operation tripping / alarm checking
Tap change over opeartion healthiness.
Transformer compartment lamp
Proper HT Cable support
GI earthing strip supporting Insulator condition
(e) LT compartment Check Points :-
Manual operation of ACB - charging ,
Manual closing and opening.
Charging of ACB by Motor if available
Tightness off all busbar
Earthing connection verification.
Indication Lamp of Phase
LT BKR / ACB indication ( alarm / trip)
Protection relay working- LT
Note for Item No 1 :-
(i) Spare parts /items shall be measured and paid under revelent items of schedule
(ii) AMC will be carried entire satisfaction of engineer-in-charge
Following spare part shall be used for SAFEPLUS RING MAIN UNIT
S&F in repair Bushing 400 Series Bolted Type item Code NHP201699R1
S&F in repair O Ring 72 x 6 BUSHING 400 SERIES BOLTED item Code NHP402076P15
S&F in repair SHAFT FOR OPERATING HANDEL item code NHP304961P1
S&F in repair 2PA Mechanism w/o hex rod item code NHP101985R002
S&F in repair TRIP COIL SAFEO FORCE AMPL WIC & ASHDA item code 1VDP000142R1
S&F in repair Linkage between K and A item code NHP201703R1
S&F in repair PUSH BUTTON RED W/ LABEL "O" item code 1SFA616199R1104
S&F in repair PUSH BUTTON GREEN W/LABEL "I" item code 1SFA616199R1106
S&F in repair BRACKET 'A' Mechanism hldg 2 push buttons item code NHP201536P1
S&F in repair Opening Finger, Manual Operating_D item code 2RAA011099A0001
S&F in repair Closing Finger, Manual Operating_C item code 2RAA011100A0001
S&F in repair BRACKET for 'K' Mechanism item code NHP201495P1
S&F in repair BRACKET FOR CT MTG RMU RHS item code NHP304233P1
S&F in repair 24 kV VPIS cord item code PTMVT120702-01
S&F in repair Capacitor Unit, VPIS, 9-15kV without cord item code YN1V400916-587
S&F in repair PRESSURE REFILLING EQUIPMENT( KAR-6) item code IN54280001-K
S&F in repair RONIS KEY WITH HARDWARE item code 4200669056.9005
S&F in repair RONIS LOCK & KEY FOR RMU WITH KEY A item code 4200040617.1001
S&F in repair RONIS KEY INTERLOCK OF LBS WITH KEY C item code 4200130305.9001
S&F in repair RONIS INTERLOCK EL11P OF LBS WITH KEY B item code 4200033538.9005
S&F in repair Fuse Holder Assembly item code NHP201487R001
S&F in repair TERMINAL PROTECTOR SILCAB (RAYCHEM) for 11kV item code 1VYN303050-060
S&F in repair T SHROUD (NEW) for 11kV item code 1VYN403250-92N
S&F in repair Reducer Stud for Cable Bushing_A 128 item code 2REA024265P0001
S & F in repair Trip Coil Only Y1 Control Volt 24 VDC item code NHP304453R1
S & F in repair Close Coil Only Y2 Control Volt 24 VDC item code NHP304453R6
S & F in repair O Ring 65 x 5 For LBS Mech Bushing item code NHP402076P24
S & F in repair Spring charging Motor with Gear 24 V DC item code NHP201491R1
S & F in repair WIKA make Manometer+Gas density switch item code YN1V400929-420
S & F in repair ELECTRONIC MOTOR KIT FOR C MODULE-MGVCL item code 4200901778.9004
S & F in repair STANDARD MOTORISED KIT FOR V MODULE item code YN1V400922-023
S & F in repair BRACKET-FOR RMU (New Indication) item code NHP304264P1
S & F in repair Position indicator item code 1VDP001531P001
S & F in repair Indicator local item code 1VDP002477P001
S & F in repair Shaft item code 1VDP002579P001
S & F in repair Indicator Flag C-module OFF item code 1VYN403050-496
S & F in repair Indicator Flag C-module ON item code 1VYN403050-498
S & F in repair Indicator Flag C-module PLAIN item no 1VYN403050-499
S & F in repair Manometer+Gas density switch(CO contact) item code 4200800466.5012
S & F in repair STANDARD MOTORISED KIT FOR C MODULE item code YN1V400922-022
S & F in repair BATTERY -12VDC ,12AH item code 1VYN401350-173
S & F in repair Capacitor Unit,VPIS 15-24kV without cord item code YN1V400916-588
S & F in repair S series bushings item code 2REA020480A0001
S & F in repair O ring for S series bushing item code 3WEA010283P0001
S & F in repair GEARED MOTOR 24VDC (MS) item code No 1VCR012079G0001
S & F in repair SHUNT CLOSING RELEASE -MC 24VDC item code no 1VCR004291G0001
S & F in repair VD4 MC Closing Coil (48V AC-DC)) item code no 1VCR004291G0003
S & F in repair SHUNT CLOSING RELEASE 110VDC/AC -MC item code No 1VCR004291G0005
S & F in repair MC Closing Coil(220-250V DC/220-250V AC) item code no 1VCR004291G0007
S & F in repair Tripping coil of VD4 24 VDC item code no 1VCR004289G0001
S & F in repair SHUNT OPENING RELEASE 110DC/AC -M01 item code no 1VCR004289G0005
S & F in repair Open. Coil Mo1 (220-250V DC/220-250V AC) item code no 1VCR004289G0007
S & F in repair MO2 Assy. (24Vcc)(Additional Trip) item code no 1VCR002985G0001
S & F in repair AUX.SWITCH 2NO+3NC PLUG CONN.,FORK TYPE item code no GCE7002397R0122
S & F in repair AUX.SWITCH 3NO+2NC PLUG CONN.,FORK TYPE item code no GCE7002397R0121
S & F in repair BKR Auxiliary Switch Assy._C item code no 2REA016209A0001
S & F in repair Closing spring signalling item code no 510831-802
S & F in repair SWITCH ELEMENT S826 E/L item code no NZN000859P11
S & F in repair Auxiliary Switch Assembly_A item code no 2REA009781A0001
S & F in repair Disconnector Mechanism assembly item code no 2REA016749A0001
S & F in repair Ring switch mechanism RH item code no 2REA009811A0004
S & F in repair Ring switch mechanism LH item code no 2REA014003A0001
S & F in repair Bushing + Contact Knives Assembly RH_B item code no 2REA010249A0001
S & F in repair Bushing + Contact Knives Assembly LH_B item code no 2REA010249A0002
S & F in repair TP bushing assembly item code no 2REA010376A0002
S & F in repair T-off cable bushing item code no 2REA009169A0001
S & F in repair VPIS Cable Switch L1-0.7, L2-0.6, L3-0.5 item code no 2REA014974P0002
S & F in repair VPIS Cable T-Off L1-1.36,L2-1.255,L3-1.15 item code no 2REA014974P0001
S & F in repair ABB RELAY TYPE REJ 603-REJ603BB401NN3XE item code no YN1V400919-532
S & F in repair Operating Handle Assembly_C item code no 2REA017122A0001
S & F in repair OPERATION COUNTER item code no 510753-802
S & F in repair OPENING SOLENOID ASSEMBLY_B item code no 2REA016775A0001
S & F in repair GAS SPRING FRONT DOOR_03 item code no 308(A)-02
S & F in repair Manometer assembly item code no 2REA013719P0001
S & F in repair Manometer with density switch assembly item code no 2REA013719P0002
Note for item No 2 to 76:- Item Code No given for spare part are of make ABB contractor may use spare part of other make as approved by the Engineer in Charge
(Note: Item no 1 to 76 If any above HT/LT Equipment and connected items become breakdown, the contractor shall locate the problem/fault at site within 12 hours on intimation by JE/Engineer-In-Charge and ensure that the fault and rectified within 24 to 48 Hours , failing which an amount of Rs 200 /- per hour will be recovered as penal recovery from any payment due to the contractor after expiry of 48 hours.)
SURESH ELECTRICALS
Sukhi Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .