Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹51.5 L+₹2.7 L (5.48%)Rejected-Finance PLOT NO 361 FLAT NO 06 FIRST FLOOR SECTOR 11 HIRAN MAGRI UDAIPUR 313001 RAJ | UDAIPUR | UDAIPUR | RAJASTHAN | 313001 | L2 | Rejected-Finance Rejected being L2 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
18 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (ARMY) CENTRAL JODHPUR
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
SPL REPAIR FOR BLDG NO P305 01 TO 04 OFFRS MD ACCN OPPOSITE JSI OFFICERS COLONY AND OTHER SANCTIONED WORKS IN ARMY AREA UNDER AGE BR I OF GE ARMY CENTRAL JODHPUR(9141/E8)
2022_MES_554228_2
GE/J/A OF 2022-23 (9141/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (ARMY) CENTRAL MULTAN LINE ARMY AREA JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) CENTRAL JODHPUR
₹99,000
Yes
4 Nov 2022
1 Oct 2022
20 Oct 2022
1 Oct 2022
18 Oct 2022
6 Oct 2022
Amount
B/R WORKS Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness ( below or above ground level) of any description and removing rubbish to out side MD land complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concerete, subbase complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) laid in alternative bays as in plinth protection including finishing the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight, complete all as specified and directed.
Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any colour, design & pattern, & size/ shape, as approved by GE as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
Demolition of brick work/stone masonary built in cement mortar including all quoins, pillars, etc., removal of unserviceable materials, debris, rubbish to outside MD land, complete all as specified and as directed by Engr-in-Charge.
M&L for cutting into old masonry to form toothings for bonding in new brick or stone work including making good in cement mortar 1:6, complete all as specified and as directed.
M&L for squared rubble walling, Jodhpur type, regular coursed, well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and as directed.
All as per item No 8 here-in-above, but except stone.
Precast cement concrete block masonry using PCC 1:2:4, type B-1 solid blocks, 10 cm thick and setting in cement mortar 1:6, straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed.
Extra over square rubble stone walling, Jodhpur type, regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing, complete all as specified and as directed.
Dismantling, stone slab, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as directed.
Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and as directed by Engr-in-Charge.
M&L for 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring, incld. finishing the surface even & rough to receive tiling etc., complete all as specified and as directed.
M&L for ultra charged vitrified tiles, 10 mm thick (square/ rectagular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.96 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles, including & over 15 mm thick screed bed in cement mortar 1:6, complete all as specified and as directed. Make : Somany/ Kajaria/ Johnson as approved by GE.
All as per item No. 15.00 here-in-above, but as in skirting / dado including & over 10 mm thick backing coat in cement motar 1:4
Joint free non skid ceramic coloured tiles (premium quality) of size 6 to 7 mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. Make : Kajaria/ Somany/ Jhonson as approved by GE.
Joint free non skid ceramic coloured tiles (premium quality) of size 6 to 7 mm thick (square/rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.38 Sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed. Make : Kajaria/ Somany/ Jhonson as approved by GE.
M&L for digital glossy wall tiles (premium quality) of size 350X450X7 mm / 250X375X7 mm, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles (Highlighter pattern), over and including 10mm thick backing coat in CM (1:4) complete all as specified and as directed. Make : Kajaria/ Somany/ Jhonson as approved by GE.
M&L for 20-25 mm thick machine cut kota stone slab, as in flooring, cooking platform & etc. over and including 15mm thick cement screed bed in CM 1:6 laid and jointed with grey cement clurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing ,complete all as specified and as directed by Engr-in-Charge.
M&L for 20-25 mm thick machine cut kota stone slab, as in skirting, dado, riser, pillar, steps & etc. over and including 10mm thick cement screed bed in CM 1:4 laid and jointed with grey cement clurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing ,complete all as specified and as directed by Engr-in-Charge.
M&L for 20 to 22 mm thick (telephone black shade) granite stone, as in cooking plateform, window cill, WHB counter top, pillar, steps, jambs, & like similar type work, machine cut, (table rubbed and polished) best quality as per sample, including & over 20 mm thick screeding in CM1:3 including rounding & double mouldlng with jointless finish of the edges, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.providing suitable dia hole in the slab for the gas pipe, complete all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc including removing rubbish to out side MD land complete all as specified and as directed.
Rendering 15 mm thick in cement mortar 1:4 on stone masonry surfaces, finished surface fair & even,with out using extra cement, mixing with WPC as per manufacturer instruction, complete all as specified and as directed.
M&L Rendering 10mm thick in CM 1:3 on concrete surfaces on ceiling / facia /RCC Chhaja etc all as directed & finished surface even & smooth, complete all as specified and as directed by Engr-in-Charge.
Rendering 15 mm thick in cement mortar 1:6 on stone masonry surfaces, finished surface even & smooth,with out using extra cement, mixing with WPC as per manufacturer instruction, complete all as specified and as directed.
Racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed by Engineer-in-charge.
M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in CM 1:3 all as specified.
M&L for preparing new plastered or unplastered surfaces and applying one coat wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper on walls, complete all as specified and as directed. Note:- OBD shall be in one or more colours/ shades all as approved by GE.
Complete removal of existing treatment of any description on walls and and applying two coat wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distempe, complete all as specified and as directed. Note:- OBD shall be in one or more colours/ shades all as approved by GE.
Preparing new plastered or unplastered surfaces and applying three coats of white wash on wall complete all as specified and as directed.
Preparing new plastered or unplastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed.
Preparation of old white washed surfaces complete removal and applying two coat of white wash on wall surfaces complete all as specified and as directed.
Preparation of old white washed surfaces complete removal and applying two coat of white wash on ceiling surfaces complete all as specified and as directed.
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coats of cement base paint of approved quality & tint, over & including one coat of chalk white, complete all as specified and as directed.
Preparation of old painted surfaces of walls complete removal and applying two coat of cement base paint complete all as specified and as directed.
Preparation of new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed .
M&L preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking of shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
Taking down shutters of any description area exceeding 1.0 Sqm but not exceeding 2 Sqm each complete all as specified and as directed.
Taking down Shutters of any description and refixing the shutters in the same opening of any description exceeding 1.00 Sq.m and not exceeding 2.00 Sq.m each after easing and adjusting complete all as specified and as directed.
Taking down of steel window and ventilators, complete all as directed by Engr-in-Charge.
S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge. Note : Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge. Note : Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
S&F of Box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete with glazing bars, complete all as specified and as directed by Engr-in-Charge.
S&F of Box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete without glazing bars, complete all as specified and as directed by Engr-in-Charge.
Rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars ,barred iron doors; ladders ;framed balusters walk ways railings framed work of water tanks and similar work confirming to Fe-290Gde E-165 complete all as specified and as directed.
M&L for mild steel framed work as in brackets etc for cooler stands etc framed steps/stairs etc complete using MS angle iron Steel bars gusset plate etc complete all as specified & directed .
S&F mild steel frame work as in stairs ,hand rails half round or other stock section or section or core for wooden hand rail straid portion drilled and countershunk for balusters running bars for doors balusters nosing to steps including embeded in concrete and screwing etc hid ties for roof including securing bolts post and struts in fencing including cutting tops to shape as directed drilling holes nothing for wire etc flat iron fillet for necessary drilling bolting or riveting etc and similar work confirming to Fe 410-0 or fe 310-0, complete all as specified and as directed.
M &L for Framed work as in door or gates of angle ,MS hollow pipes, solid SQ sections Flat iron etc or other section with gusset plates, rails, braces etc complete with steel sheetingas required to br prepared for hanging or sliding with and including MS Channel as posts & hold fasts & suitable arrangements for locking etc complete all as specified & directed conforming to Fe 290.Gde E165, complete all as directed by Engr-in-charge.
S&F 35mm thick factory made second class hardwood glazed and skelton door shutters, open rebated and prepared to receive glass/gauze etc(without sash bar) edges of framing plain chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge in SSR Pt I-1991 section 8 clause 8.24 (b), including stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with SS wire staples & aluminium grill medium grade mess size 50X50mm fixed at outer edge of door incld pink primer, complete all as specified and as directed.
S&F factory made flush shutters 35 mm thick, solid core construction, with block board and plywood face panels, both faces is covered with salmica with lipping/frame to match with moisture content not less than 12% as per IS. The face panel comprising of ply wood or cross band and face veneers shall be glued by hot pressed process, complete all mortic lock and handel arremgment, complete all as specified and as directed.
S&F of factory made solid panel PVC flush door shutter, 30 mm thick (style) consisting of wpc frame made of MS tubes for top & bottom rail. MS frame shall be covered with heat moulded plain color pvc ‘C’ channel having a pvc sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain color pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted to the MS Frame/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and as directed.
M&L for solid PVC door frame of size 50x47mm made out of 5mm thick PVC sheet reinforced with MS square tube, complete all as specified and as directed.
S&F 200mm long aluminium anodised tower bolt, complete all as specified and as directed by Engr-in-Charge.
S&F 150mm long aluminium anodised handle extruded section, complete all as specified and as directed by Engr-in-Charge.
S&F of brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long, complete all as specified and as directed.
S&F of stainless steel butt hinges 100mm size, complete all as specified and as directed.
S&F butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type C-11, complete all as specified and as directed.
S&F 100mm size single action door spring hinge, complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body and tounge anodised with hard drawn steel spring 140mm long, complete all as specified and as directed.
S&F for 3mm thick plain glass ordinary quality & glazing, complete all as specified and as directed.
S&F wire netting of stainless steel wire 1.23 mm dia, 12 mm size of mesh fixed with tinned tacks of stainless steel wire staples
S&F in replacement GI steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.00 mm with necessary fitting on steel/ wooden surface, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in coping/ benching, DPC, pier caps, bed blocks, for hold fast etc., including mixing with WPC and necessary form work, complete all as specified and as directed by Engr-in-Charge. Note:- WPC shall be measured and paid separately.
S&F flat iron for hold fast and similar work confirming to Fe-290 Gde-E-165 fixed with welding and necessary item, complete all as specified and as directed.
S&F in replacement decorative type curtain rod stainless steel finish of pipe 22 to 25mm dia with best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement Glass Shelf 550mm long fixed with and including chromium plated brass screws and wooden cleats, complete all as specified & direceted by Engg.-in-charge. Make:- Jaguar Cat No. AQN-7771
S&F in replacement CP soap dish fixed with screws complete all as specified and directed. Make:- Jaguar Cat No. AQN-7731
S&F in replacement CP towel rail 450mm long fiexd to wall with chromium plated brass screws and woodn cleats Min weight 170gms approved make complete all as spcified and directed. Make:- Jaguar Cat No. AQN-7711A
S&F in replacement FRAMED MIRROR 800 x 600 mm, 5 mm thick glass mirror with double coat for protection and longevity, decorative PU frame and silver plating on the back for better reflection to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. Make:- Cera Cat. No. B3510137
S&F in replacement MS chromium plated peg set of five fixing with wall, complete all as specified and as directed.
S&F in replacement stainless steel sink with drainage board made of 1mm thick sheet, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarfwall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm, complete all as specified and as directed. Make : Nirali/ Jayna/ Bluestar as approved by GE.
S & F in repacement super special colours vitreous china squatting pan "Orissa pattern" of size 580 mm X 440 mm with integral foot rests and PVC 'P' or 'S' trap, etc., complete all as specified and as directed. Make:- Cera Cat No.CALINA S3010102 or equivalent in Hindware / Parryware as approved by GE
S&F in replacement Ivory two piece wall hung extended EWCs with seat cover and twin flush fittings, including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' trap connecting to drain pipe and flushing pipe etc., complete all as specified and as directed. Make:- Cera Cat. No. S1031103 P Trap, Cat. No. S1060103 Cistern, Cat. No. B1520167 Campbell Slim Soft Close Seat Cover, Cat. No. B1810106 twin flush fittings, or equivalent in Hindware / Parryware as approved by GE
S&F in replacement vitreous china ware wash hand basin, white, flat back of size 550 mm X 450 mm including 32 mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 15 mm size 2 nos PVC connection pipe 450 / 600 mm long with PTMT nuts , 32mm bore (low density polythene ) LDPE flexible waste pipe, complete all as specified and as directed. Make:- Cera Cat. No. CALBURT S2020137 or its equivalent model in Hindware / Parryware as approved by GE
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 110mm bore, complete all as directed.
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 75mm bore, complete all as directed.
S&F in replacement 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors of suitable size complete all as specified and as directed .
S&F in replacement 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors of suitable size complete all as specified and as directed .
S&F in replacement 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in floor, with MS clamps of suitable size complete all as specified and as directed .
S&F in replacement 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in floor, with MS clamps of suitable size complete all as specified and as directed .
S&F 75 mm bore (SWR) PVC bends any radius with access door complete all as specified and as directed.
S&F 110 mm bore (SWR) PVC bends any radius with access door complete all as specified and as directed.
S&F for 110mm bore PVC cowls, diminishing pieces or tapers (larger bore measured), complete all as specified and as directed by Engr-in-Charge.
S&F for 75mm bore PVC cowls, diminishing pieces or tapers (larger bore measured), complete all as specified and as directed by Engr-in-Charge.
S& F 75 mm bore PVC [SWR] Junction single [single "T"] equal or unequal with access door complete all as specified and as directed.
S& F 110mm bore PVC [SWR] Junction single [single "T"] equal or unequal with access door complete all as specified and as directed.
S&F 110mm bore PVC [SWR] branch piece, single (single Y) equal or unequal complete all as specified and as directed.
S&F 75mm bore PVC [SWR] branch piece, single (single Y) equal or unequal complete all as specified and as directed.
S&F 75mm dia PVC floor trap plain grating including jointing with solvent cement 75mm dia, complete all as specified and as directed.
S&F 75mm dia PVC multi floor trap plain grating including jointing with solvent cement 75mm dia, complete all as specified and as directed.
S&F 75mm dia PVC gully trap plain grating including jointing with solvent cement 75mm dia, complete all as specified and as directed.
S&F in replacement CP wall mixer with telephonic shower arrangement ,connecting legs and wall flanges but with out crutch and telephone shower complete all as specified and as directed. Make: Jaquar Model No.FUS-29281 & HSH-1937 or equivalent model in Cera / Hindware / Johnson
S&F in replacement Fancy type Chromium plated over head shower 150 X 150mm size with arm, square shape, single flow (ABS body CP with gray face plate) with Rubit cleaning system, Shower Arm 400X25X25mm square shape for wall mounted showers with flange suitable for 15mm bore pipe, including fixing to steel pipe or union, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar cat No. OHS-1805 (Shower) & SHA-455L400 (Shower arm) / Kohler/ Cera as approved by GE.
S&F in repair 25mm dia stop valves, cast copper alloy with screw down high pressure with crutch or butter fly handle screw both ends for iron pipe or for union & fixed of 25mm dia, complete all as specified and as directed. Make : Jaquar/ Kohler/ Cera as approved by GE.
S&F in replacement angular stop valves cast copper alloy chromium plated (ISI marked) screwed down high pressure fancy type screwed both ends for 15mm bore of iron pipe or union, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar cat No. ALI 85053 or its equivalent model in Kohler/ Cera as approved by GE.
S & F in replacement CP two way anglular stop cock with wall flange, screwed down high pressure,screwed both ends for 15 mm bore iron pipe or for unions complete all as specified and as directed. Make: JAQUAR / Kohler/ Cera as approved by GE
S&F in replacement chromium plated, cast copper alloy, fancy type quarter turn 15mm bore bib cock with wall flange, complete all as specified and as directed. Make : Jaquar Cat No. OPP-15037 or equivalent in Kohler/ Cera as approved by GE
S&F 10 ltrs capacity PVC valve less(Super special colors), (ISI Marked) syphonic action type, flushing cistern, low level, with Anti Bacterial Knob, with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia and, cistern colour shall be match WC colour, complete all as specified and as directed. Make:- Cera cat. No. B1010102 CIENA PREMIUM or its equivalent model in Parryware / Jhonson as approved by GE
S & F CP Health faucet with 1200 mm long & 80 mm dia flexible steel tube with wall hook with Non Return Valve [back flow preventer] complete all as specified and as directed. Make: Model No.ALD-573 of JAQUAR
Dismantling existing water tank of capacity exc 250ltrs and not exc 500 ltrs and removing from site, complete all as directed by Engr-in-Charge.
Dismantling existing water tank of capacity exc 500ltrs and not exc 1000 ltrs and removing from site, complete all as directed by Engr-in-Charge.
S&F in replacement 500 ltrs capacity rotational moulded polythene water storage tank white colour, three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms, including dismantling of old U/S PVC/RCC water tank & removing to store or outside MD land or credit to contractor, complete all as specified and as directed by Engg.-in-charge. Make:- Sintex (Pure Antimicrobial)
S&F in replacement 1000 ltrs capacity rotational moulded polythene water storage tank white colour, three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms, complete all as specified and as directed by Engg.-in-charge. Make:- Sintex (Pure Antimicrobial)
S&F stainless steel plate rack of size 1200mm X 1000mm X 200mm of approved pattern made out of stainless steel sheet 1 mm thick with round 8mm dia rods complete all as specified and directed. Make : Nirali/ Jayna/ Bluestar as approved by GE.
Taking out from position framed wood work as in cupboards/cabinets etc with all fittings ,shutters, shelves, drawers etc in any position fixed in walls or floors & removal of the rubbish outside MD land all as directed at site for overall sizes exc 0.50 sqm but not exc 1.50 sqm & depth not exc 60cm, complete all as directed.
Providing and fixing polyvinyl chloride (PVC) sheet frame of width 150mm & 18mm thickness made out of extruded 18mm PVC sheet and joined with suitable Cement Solvent adhesive and screw.The frame shall be fixed to the wall using 75mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 3 Nos. of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member etc, all as per manufracturers specifications, complete all as specified and as directed by Engr-in-Charge. Make:- Rajshree.
M&L for 18 mm thick solid PVC sheet UPVC Coated Celuka printed in one of two different colours( with wood grain printed pattern /ivory colour finish) as in kitchen cabinet shutters & cupboard shutter, all round body of cabinets , shelves ,drawers etc cut to required size jointed with solvent cement & steel screws etc., complete all as specified and as directed. Make:- Rajshree.
S&F continious piano hinges, stainless steel, complete assembly complete all as specified and directed.
Extra over solid PVC sheet for fixing 18 mm width & 2-3 mm thick PVC coloured lipping of approved design & colour fixed with solvent cement or headless nails, complete all as specified and as directed.
S&F '0' degree clip type self closing hinges for cabinets fixed with cadimum coated screws, complete all as specified and as directed.
S&F 100mm size bright finished cromium plated steel handle of approved shape & design fixed with cadmium coated screws on the kitchen cabint shutters, complete all as specified and as directed.
All as per item No. 114.00 here-in-above, but size 75 mm.
S&F magnetic catches for cabinets of size 50 mm complete with striking plate & magnetic stud complete all as per approved smaple. Make:- Hettich/Haffle
S&F drawer runners folding type with guide channels & sliding channel with approipiate ball bearing/ rollers etc complete to obtain smooth movement of the drawers. Make:- Hettich/Haffle
M&L for stainless steel tray as per trade pattern of various sizes for drawer to keep the kitchen utensil as directed by Engineer-in-charge Make:- Hettich/Haffle
M&L 50mm thick PCC 1:2:4 type B1 using 20mm graded aggregate platform for water tank complete all as specified and as directed
Demolition of cement concrete (unreinforced) of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance noexceeding 50 mtr & depositing where directed. complete all as specified and as directed.
Sand stone slabs, 5 cm thick, Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and as directed.
Supply only integral water proofing compound ISI Marked all as specified.
S&F in replacement precast steel fibre reinforced concrete (SFRC) any colour, 75-100mm thick manhole cover with frames (ISI marked) of overall covered area not exceeding 3.00 Sqm with clear opening not less than 0.36 Sqm, any shape (round, square, rectangular etc;) provided with suitable mild steel rims to prevent from chipping of edges and enable clear opening with provision of easy lifting hooks which are duly protected against corrosion laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
Taking up or down 25mm bore steel tubing and connections including cleaning for refixing or credited to contractor complete all as specified and as directed.
-Ditto- All as per Item No. 124 above but 20 mm dia
-Ditto- All as per Item No. 124 above but 15 mm dia
Refixing old GI water tubing of 25 mm bore, medium grade including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
All as per item No. 127.00 here-in-above, but size 20 mm bore
All as per item No. 127.00 here-in-above, but size 15 mm bore
S&F of water GI tubing medium grade, galvanized, with all fittings fixed to wall, ceilings or laid n floors, complete all as specified and as directed. (a) 25 mm dia,
-Ditto- All as per Item No. 131 above but 20 mm dia
-Ditto- All as per Item No. 131 above but 15 mm dia including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc., complete all as specified and as directed.
Taking down existing old tar-felt RCC roof treatment, and demolition of cement concrete (unreinforced) of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance noexceeding 50 mtr & depositing where directed. complete all as specified and as directed
M&L for neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions over the RCC roof slab for laying of water proofing treatment including providing the following as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 100mm micron HMHDPE, outer film 20 micron each, thickness 3.00mm having weight not less than 3.00 Kg/Sqm using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen confirming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) Top layer : 40 mm thick PCC 1:2:4 type B-1 using 12.5mm graded crushed stone aggregate in roof padding for maintain slop on roof finished even and smooth with using extra cement NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause No. 21.3, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item. 3. This work shall be carried out by authorized applicator
M&L PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate in roof padding , the surface of concrete is to be finished even and fair with out using extra cement complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed .
Returning filling excavated soil/rock in including spreading, levelling, watering and well ramming in layers not exc 25cm, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material (soil) not exceeding 50 meter and deposing where directed at a level not exceeding 1.5 meter here-in-above the starting point, complete all as specified and directed.
M&L earth filling under floor or in foundations including watering and consolidation complete all as specified and as directed.
M&L for hard core broken stone of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, water and rammed to a true surface, with 8-10 tonne power roller, complete all as specified and as directed by Engr-in-Charge.
Joint free digital ceramic coloured heavy duty parking tiles (GRC) of size 8 to 10 mm thick (square/rectangular) area of each tiles exceeding 0.08 Sqm but not exceeding 0.16 Sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed. Make : Kajaria/ Somany/ Jhonson as approved by GE.
Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and as directed.
M&L roughly squared stone lintels hammer dressed on face and soffits,hoisted, set and pointed in cement mortar 1:6 complete.n exc 3m in length complete all as specified & directed by Engineer-in-charge.
Sand stone slabs, 5 cm thick machine cut, Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and as directed.
S&F of aluminium, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long, complete all as specified and as directed.
Excavating in post holes or similar holes each not exc 0.50 cu.m, getting out soft/loose soil, returning,fillig in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing srplus soil soil to a distance not exc. 50 m, complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS:1161-1979 Grade St-240 complete all as specified and as directed.
M&L prepainted Galvalume aluminium zinc coating GI based corrugated steel Sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
M&L RCC (nominal mix) 1:1½:3 type A1 by using 20mm graded stone aggregate as in slabs supported on walls, beams and colunms in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
RCC 1:1½:3 type A1 by using 20mm graded stone aggregate as in colunms, pillars, piers, posts and struts including necessary form work complete all as specified and directed.
S&F precast cement concrete louvers and jallies, 35mm thick (measured solid) including all moulding, excluding frame, PCC 1:2:4 type B-0 (using12.5mm graded crushed stone aggregate) set in CM 1:4, complete all as specified and as directed.
E/M WORKS Taking down copper/aluminium point wiring surface/ concealed (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell etc. removing materials from site of work complete or removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc., complete all as directed by Engr-in-Charge.
Taking down copper/aluminium sub main wiring surface/ concealed complete, including fixture and fittings removing materials from site of work complete or removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc, complete all as directed by Engr-in-Charge.
Modular Point wiring using approved colour coding as per IS code, with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty drawn through and including in 20mm dia PVC rigid conduit with all accessories complete concealed (or on surface as per site requirement) in wall/roof/floor etc, ISI marked and terminated to and including provision of sunken 1.6mm thick pressed steel terminal boxes with modular sheet cover on top for fixing modular switches, sockets / regulators etc., inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light / fan / bell point controlled by one, one way switch complete all as specified and directed .
All as per Serial Item No.15500 here-in-above but for one 3 pin socket outlet 5/6 Amps on the independent board , complete all as specified and as directed.
All as per Serial Item No.155.00 here-in-above but for one 3 pin socket outlet 5/6 Amps on the same board with other switches complete all as specified and as directed.
All as per Serial Item No.155.00 here-in-above but for one light point control by two way switch complete all as specified and as directed.
All as per item No 155.00 here-in-above but with using 2.50 Sq mm FRLSH single core multistanded copper conductor cable and 2.50 sq mm PVC FRLSH insulated unsheathed stranded copper conductor for common earth wire for 6 pin 15/16 Amp socket outlet on independent board .
All as per item No 155.00 here-in-above but with using 4.00 Sq mm FRLSH single core multistanded copper conductor cable and 4.00 sq mm PVC FRLSH insulated unsheathed stranded copper conductor for common earth wire for 6 pin 15/16 Amp socket outlet on independent board .
S&F switch piano, modular type, single pole, one way, 5/6 Amps, 230 Volts, ISI Marked, complete all as specified and as directed.
S&F switch piano, modular type, single pole, one way,15/16 Amps, 230 Volts, ISI Marked, complete all as specified and as directed.
S&F switch piano, modular type, single pole, two way, 5/6 Amps, 230 Volts, ISI Marked, complete all as specified and as directed.
S&F modular bell push 6 Amp, 1 module, complete all as specified and as directed.
S&F bell electric multi music type type 230 volts single pole, complete all as specified and as directed by Engr-in-Charge.
S&F socket outlet, modular type, single pole, 2 in 1, 3 Pin, 5/6 Amps, 230 Volts,ISI Marked, complete all as specified and as directed.
S&F socket outlet, modular type, single pole, 2 in 1, 6 Pin, 6/16 Amps, 230 Volts,ISI Marked, complete all as specified and as directed.
S&F modular fan step regulator, 120W, 2 module, hum free and connecting electrically, complete all as specified and as directed by Engr-in-Charge.
Taking down fan, sealing cable end, dismantling blades and hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and as directed by Engr-in-Charge.
Taking down fan, sealing cable end, dismantling blades and hanging only exhaust fan and connecting up including provision of cable from exhaust rose or connector to fan, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, lamp holder, 4 feet long, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including taking down old u/s material, complete all as specified and as directed. Make : Bajaj Cat No. BCLSB 20 WH or Equivalent in Philips/ Havells as approved by GE.
S&F connecting, and commissioning of street light fitting 35 watt LED , IP-65 protection, single piece pressure dia cast aluminium alloy housing high impact 4 mm thick heat resistant toughned clear glass cover for lamp and matrix of LEDs in built electronic driver upto 4 KV surge protection device and setting& input power 35 W system lumens 85/W operating voltage 160-260 V contror gear compartment with high voltage, Prewired including 1.20 mtr long 32mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified Make : Philips/ Bajaj/ Havells
S&F decorative wall light made up of high grade engineering plastic material suitable for 9 W LED lamp Make:- Havells Cat part No. -LHFOFWE1TZ1W012 or its equivalent model in Philips/bajaj
S&F 9/10 W bulk head fittings of Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval plastic bulk head fitting , luminaire comprising of high brightness LEDs, IP54 protection, complete all as specified and as directed. Make : Philips/ Bajaj/ Havells.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 12 way 240 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type, complete all as specified and as directed by Engr-in-Charge Make : Legrand/ ABB/ Schneider
S&F and testing factory made sheet metal enclosure for MCB DB TPN 4 way 415 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type, complete all as specified and as directed by Engr-in-Charge Make : Legrand/ ABB/ Schneider
Taking down and re-fixing only including connecting electric meter
S&F Vertical Distribution Board, double Door, suitable for 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Make : Havells Cat Part No DHDLVSRWGOFO04 or its techno commercially equivalent make in Bajaj / Philips Note : MCCB & MCB shall be measured and paid for separately.
S&F in replacement RCCB, 30 mA, 415V, IP 20 protection, 4 Pole with over load and short circuit protection, (ISI marked), as in replacement, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F in replacement MCCB, 'A' Frame, thermal adjustable magnectic setting, Ics = 75%, 25 KA, 415V, 100 Amp, 4 Pole with over load and short circuit protection, (ISI marked), as in replacement, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB SP 240 volts rating from 5-32 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection, as in replacement, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB SPN 240 volts rating from 40 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection, as in replacement, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB SPN 240 volts rating from 63 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection, as in replacement, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB TPN 240 volts rating from 63 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection, as in replacement, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F in replacement sub main wiring with four runs of 10 sqmm & two runs of 10 Sqmm earth wire 1100 volt grade PVC insulated but unsheathed multi stranded copper conductor FRLSH cable, single core cable conforming to IS 694 with valid CML No. & ISI Marked, (Phase-Red, Neutral-Black, Earth-Green) drawn through and including 15mm dia PVC rigid conduit with accessories surface mounted on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly complete all as specified and directed. Note :- Six runs of 10 sqmm and one run of PVC conduit shall be measured as one length for the purpose of measurement.
S&F in replacement sub main wiring with two runs of 4 sqmm & one runs of 4 Sqmm earth wire 1100 volt grade PVC insulated but unsheathed multi stranded copper conductor FRLSH cable, single core cable conforming to IS 694 with valid CML No. & ISI Marked, (Phase-Red, Neutral-Black, Earth-Green) drawn through and including 15mm dia PVC rigid conduit with accessories surface mounted on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly complete all as specified and directed. Note :- Three runs of 4 sqmm and one run of PVC conduit shall be measured as one length for the purpose of measurement.
M&L in repairs for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron earth lead wire of size 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion, complete all as specified and as directed by Engr-in-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply, laying (in trenches), testing & commissioing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 Core, complete all as specified and as directed by Engr-in-Charge.
Supply and spreading clean dry sand ( river sand) in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 300x180mm x40 mm, complete all as specified and as directed.
M&L for galvanised steel tubing, medium grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 40 mm bore, complete all as specified and as directed. Make : Prakash/ Tata/ Jindal
Supply, Installation, testing & commissioning of 1.50 Ton split AC, 5 Star rating, with cordless remote control unit, inclding air ionizer and plasma filter for better indoor air quality with energy efficient with 2.0 KVAR stablizers copper wound voltage range from 170 V to 280 V, complete all as per specified & directed by Engg.-in-charge. Make: O'General/ Hitachi /Daikin as approved by GE.
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor/ Legrand/ Havells
S&F in replacement sub main wiring with two runs of 6 sqmm & one runs of 6 Sqmm earth wire 1100 volt grade PVC insulated but unsheathed multi stranded copper conductor FRLSH cable, single core cable conforming to IS 694 with valid CML No. & ISI Marked, (Phase-Red, Neutral-Black, Earth-Green) drawn through and including 15mm dia PVC rigid conduit with accessories surface mounted on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly complete all as specified and directed. Note :- Three runs of 6 sqmm and one run of PVC conduit shall be measured as one length for the purpose of measurement.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 8 way 240 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type, complete all as specified and as directed by Engr-in-Charge Make : Legrand/ ABB/ Schneider
S&F exhaust fan, heavy duty steel body, AC single phase 300 mm sweep complete with louvers including fixing/grouting of frame & connecting with & including 3 core PVC insulated copper conductor flexible cable of size 23/0.0076 (or eq. Size in mm) from ceiling rose to fan, complete all as specified and as directed by Engg.-in-charge. Make : Havells/ Bajaj/ CG
NOTE:- (i)- Quantities are clubbed in BOQ for different Jobs. For which ref. Annexure-I on Sl. page. No. 41 to 44 of tender document. (ii)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
M/s Ajay kumar Garge
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .