Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹43.6 L
EMD Value
₹87,180
Closing Date
19 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AFA) Hyderabad
GE (AFA) Hyderabad, Dundigal, Hyderabad
SPECIAL REPAIRS REPLACEMENT OF DG SETS INCLUDING CONNECTED WORKS AT AFA HYDERABAD
2026_MES_751387_1
8655
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HYDERABAD
As per NIT documents
5 documents required · 5 mandatory
₹500
GE (AFA) HYDERABAD
₹87,180
Yes
5 Feb 2026
5 Feb 2026
21 Feb 2026
5 Feb 2026
19 Feb 2026
10 Feb 2026
5 Feb 2026 - 9 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for repairs to 15 KVA DG Set Alternator by removing the same from Engine of DG Set, transporting the same to work shop and carrying out necessary repairs such as taking out the burnt out windings and rewinding with Super Enameled Copper wire of same Gauge, Turns and Weight including insulating material such as insulated paper, glass sleeve, cotton tape, varnish etc. & checking of Rectifier, Exciter, Rotor, Stator, Brushes, Commutator, Fan, Brush arm, Armature Ball Bearing, Field Coil etc complete and re-fixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs and testing complete all as specified and as directed & to the entire satisfaction of the Engineer-in-Charge. | 5 | Each Job | 10 | ₹50 |
| 1.01 | IMPORTANT NOTE : (i) Cost of dismantling /decoupling /transporation and refixing /re-installation, strip opening of alternator and taking out burnt winding, cleaning the slot internally as well as externally, stator and bearings etc is deemed to be included in the unit quoted rates. (ii) Complete re-winding work to be carried out at auth workshop/service centre & cost of the same is deemed to be included in the unit quoted rates. (iii) Any item/job missed out in the item description/specification but technically required for successful completion of the work/job is deemed to be included in the unit quoted rates. (iv) Warranty for one year is to be given by the Contr from the date of re-winding of the alternator. (v) Alternator shall be repaired & re-installed within 07 days of removal/dismantling of the old unsv unit. Penalty @ Rs. 1000/- per day shall be charged for non-commissioning of the Alternator beyond alloted 7 days as cited above. (vi) All T&P, transportation etc. will be contractor arrangement. No extra charge shall be paid by the Department on that account.
(vii) Complete job shall be carried out by a qualified Mechanic/Technician duly adopting adequate safety procedures. | - | - | - | - |
| 1.02 | (viii) Replacement of any other parts such as fan blade, connecting plate, ball bearing and repair to housing etc. is deemed to be included in the unit quoted rates. (ix) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. (x) All work shall be carried out as per OEM guidelines. (xi) Functional testing is to be carried out post-re-winding/replacement of parts to verify all control sequences, operations correctness. (xii) Quoted rate is also deemed to be inclusive of any minor spares as decided by the Engr-In-Charge.
(xiii) Ensuring compliance with system operational parameters and commissioning to full functional status. | - | - | - | - |
| 2 | Supply, install, commissioning & testing of Automatic Phase Sequence Corrector with Current Limiter (ACCL) perfectly suitable/compatible for 15 KVA capacity DG Set including removal of old u/s one complete all as specified and as directed & to the entire satisfaction of the Engineer-in-Charge. Make : Elmeasure/L&T/ABB/SIEMENS | 10 | Each | 10 | ₹100 |
| 3 | Supply, install, commissioning & testing of Auto Start and Auto Mains Failure Control Module as per existing make (Kirloskar/Cummins/Greaves Cotton) & specifications for the following capacity of DG Sets including removal of old u/s one complete all as specified and as directed & to the entire satisfaction of the Engineer-in-Charge. Make : Kirloskar/Cummins/Greaves Cotton (As per Existing)
(i) 15 KVA to 30 KVA capacity of DG Sets | 10 | Each | 10 | ₹100 |
| 4 | (ii) 62.5 KVA to 125 KVA capacity of DG Sets | 1 | Each | 10 | ₹10 |
| 5 | (iii) 160 KVA to 200 KVA capacity of DG Sets | 3 | Each | 10 | ₹30 |
| 6 | (iv) 250 KVA to 320 KVA capacity of DG Sets | 1 | Each | 10 | ₹10 |
| 7 | (v) 400 KVA to 625 KVA capacity of DG Sets | 1 | Each | 10 | ₹10 |
| 7.01 | IMPORTANT NOTE for Item Nos 2.00 & 3.00 : (i) Design/Drawing/Technical catalogue/specifications etc. from the OEM/Auth Dealer/Supplier etc. is to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items before placing order to the Manufacturer/Supplier. 2) Cost of all equipments/T&P/Transportation/Hiring Charges etc. required for successful completion of the work/job is deemed to be included in the unit quoted rates. 3) Unit quoted rate is deemed to be be inclusive of replacement guarantee of 01 Years from the date of installation of the Item/Eqpt in the event of non/improper functioning. 4) Original Purchase Vouchers & Test Certificates is to be submitted to the Engr-In-Charge for checking/records purpose. 5) Any item/job missed out in the item description/specification but technically required for successful completion of the work/job is deemed to be included in the unit quoted rates. 6) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. 7) The complete job/work is to be carried out from OEM/Auth Dealer/Supplier/Channel Partner etc. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
TENDERPAGES8655.pdf
Tender Documents • 0.43 MB
BOQ_841549.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .