Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹26.9 L+₹2.7 L (11.3%)Rejected-Finance H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹29.5 L+₹5.4 L (22.4%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹29.8 L+₹5.7 L (23.4%)Rejected-Finance 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹33.6 L+₹9.5 L (39.3%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | KAPOOR ELECTRICALS L1 | Bedi Refrigeration Works L3 | Tarachand gurudutt L4 | PARADISE INFRA POWER COMPANY L2 | M/S ROORKEE ENGINEERING L5 | Bhanu Prakash L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and taking down U/S copper / aluminium point wiring (light, fan, socket, power) complete with fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. | 2,000 | Per point | 5 ₹10,000 | 2 ₹4,000 Lowest | 8 ₹16,000 | 5 ₹10,000 | 5 ₹10,000 | 25 ₹50,000 |
| 2.00 | Taking down carefull serviceable ceiling fan from existing position of any height and refixing the same ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specifed. | 30 | Each | 14 ₹420 Lowest | 25 ₹750 | 30 ₹900 | 30 ₹900 | 100 ₹3,000 | 50 ₹1,500 |
| 3.00 | Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed. | 1,975 | RM | 3 ₹5,925 | 1 ₹1,975 Lowest | 4 ₹7,900 | 5 ₹9,875 | 5 ₹9,875 | 5 ₹9,875 |
| 4.00 | Dismantling and taking down old damaged existing DB’s /MCB Enclosure of any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified | 78 | Each | 10 ₹780 Lowest | 10 ₹780 Lowest | 70 ₹5,460 | 10 ₹780 Lowest | 20 ₹1,560 | 10 ₹780 Lowest |
| 5.00 | Taking down old serviceable meter of any size & any type from wall by disconnecting all electrical connections and refixing the same complete all as specified & directed by Engineer-in-Charge. | 20 | Each | 10 ₹200 Lowest | 25 ₹500 | 50 ₹1,000 | 50 ₹1,000 | 100 ₹2,000 | 15 ₹300 |
| 6.00 | Fixing only serviciable light fitting received against item No 01 above, complete all as specified & as directed. | 100 | Each | 15 ₹1,500 Lowest | 20 ₹2,000 | 30 ₹3,000 | 50 ₹5,000 | 50 ₹5,000 | 30 ₹3,000 |
| 7.00 | Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit MMS ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates | 230 | Per point | 375 ₹86,250 | 350 ₹80,500 | 421 ₹96,830 | 330 ₹75,900 Lowest | 500 ₹1,15,000 | 450 ₹1,03,500 |
| 8.00 | All as per item No-07 but One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed. | 60 | Per point | 100 ₹6,000 | 80 ₹4,800 | 70 ₹4,200 Lowest | 100 ₹6,000 | 200 ₹12,000 | 150 ₹9,000 |
| 9.00 | All as per item No-07 but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed . | 60 | Per point | 370 ₹22,200 | 350 ₹21,000 | 435 ₹26,100 | 330 ₹19,800 Lowest | 500 ₹30,000 | 450 ₹27,000 |
| 10.00 | All as per item No 7 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point. | 70 | Per point | 430 ₹30,100 | 550 ₹38,500 | 490 ₹34,300 | 330 ₹23,100 Lowest | 600 ₹42,000 | 650 ₹45,500 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Sept 2025, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
REPAIR/ MAINT OF INTERNAL WIRING AND REPLACEMENT OF OLD U/S FITTING IN ZONE II AREA AT CLEMENT TOWN
2025_MES_724991_1
GE/CLT/ Of 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class D Cat b(i)
7 documents required · 7 mandatory
₹500
Yes
GE Clement Town
₹90,000
Yes
1 Oct 2025
7 Aug 2025
11 Sept 2025
7 Aug 2025
4 Sept 2025
21 Aug 2025
Amount
Dismantling and taking down U/S copper / aluminium point wiring (light, fan, socket, power) complete with fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed.
Taking down carefull serviceable ceiling fan from existing position of any height and refixing the same ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specifed.
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed.
Dismantling and taking down old damaged existing DB’s /MCB Enclosure of any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified
Taking down old serviceable meter of any size & any type from wall by disconnecting all electrical connections and refixing the same complete all as specified & directed by Engineer-in-Charge.
Fixing only serviciable light fitting received against item No 01 above, complete all as specified & as directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit MMS ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates
All as per item No-07 but One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
All as per item No-07 but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per item No 7 above but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point.
All as per item No 7 above but in existing concealed conduit complete all as specified.
All as per item No 8 above but in existing concealed conduit complete all as specified.
All as per item No 9 above but in existing concealed conduit complete all as specified.
All as per item No 10 above but in existing concealed conduit complete all as specified.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including PVC conduit MMS ,duly surface to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates
All as per item No 15 above but One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
All as per item No 15 above but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per item No 15 above but above but controlled by two, two way piano switch 5/6 Amps.
All as per item No 15 above but with 2.5 Sqmm PVC insulated FRLS cable for 15 Amps power point.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including PVC Casing & caping ,duly surface to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm width (Color coding of wires shall be Phase, neutral and earth wire all as specified ) incl PVC gang boxes of supper quality or MS box with hylem sheet for housing of Switches, sockets , Bell push &fan regulators etc all as specified and directed and making good disturbed surface shall be deemed to be included in quoted rates .
All as per item No 20 above but One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
All as per item No 20 above but One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per item No 20 above but with 2.5 Sqmm PVC insulated FRLS cable for 15 Amps power point.
Supply and fixing switch modular single pole,, one-way 6Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-charge .
Supply and fixing switch modular single pole,, two-way 6Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-charge .
Supply and fixing switch modular single pole,, one-way 16 Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-charge .
Supply and fixing modular socket, 6A -2/3/5 pin combined 2 module ISI marked 230 volts, 50Hs complete all as specified by Engr-in-charge .
Supply and fixing modular socket, 6A/16A-5/6 pin combined 2 module ISI marked 230 volts, 50Hs complete all as specified and directed by Engr-in-charge .
Supply and fixing Modular bell push single pole one way 6 Amps, 1 module all as specified & directed by Engr-in-charge .
Supply and fixing step socket type modular fan regulator 240 V , 100Watt 2 module complete all as specified.
Supply and fixing ceiling rose surface bakelite 65x25mm dia having three terminals all as specified
Supply and fixing batton/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.
Supply and fixing bell ding dong AC 230/240 Volts single pole all as specified & directed.
Supply and fixing switch piano flush type single pole, one-way 5/6 Amps, 240 Volts AC
Supply and fixing switch piano flush single pole, one-way 16 Amp, 240 Volts AC
Supply and fixing socket out let 5 pin 6 Amps flush type all as specified.
Supply and fixing socket out let 5/6pin 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC all as specified.
Supply and fixing bell push piano flush type single pole one way 6 Amps all as specified.
Supply and fixing ,step switch type fan regulator 120/280 V all as specified.
Supply and fixing in repair switch piano flush type single pole, one-way 5/6 Amps, 240 Volts AC
Supply and fixing in repair switch piano flush single pole, one-way 16 Amp, 240 Volts AC
Supply and fixing in repair socket out let 5 pin 6 Amps flush type all as specified.
Supply and fixing in repair bell push piano flush type single pole one way 6 Amps all as specified.
Supply and fixing in repair socket out let 5/6pin 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC complete all as specified.
Supply and fixing in repair batton/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed.
Supply and fixing in repair bell ding dong AC 230/240 Volts single pole all as specified & directed.
Supply and fixing in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet, socket type, comlpete all as specified & as directed.
Supply and fixing in repair step switch type fan regulator 120/280 V all as specified.
Supply and fixing in repair switch modular single pole,, one-way 6Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-charge .
Supply and fixing in repair switch modular single pole,, one-way 16 Amps, 1 module 240 Volts AC all as specified and directed by Engr-in-charge .
Supply and fixing in repair modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50Hs complete all as specified by Engr-in-charge .
Supply and fixing in repair modular socket, 6A/16A-5/6 pin combined 2 module ISI marked 230 volts, 50Hs complete all as specified and directed by Engr-in-charge .
Supply and fixing in repair step socket type modular fan regulator 120/280 V , 100Watt 2 module complete all as specified.
Supply and fixing in repair Modular bell push single pole one way 6 Amps, 1 module all as specified & directed by Engr-in-charge .
S & F surface mouting PVC gang box of super quality for housing of one 5 Amp Switch & one 5 Amp Socket incl suitable size of pvc sleeve & screews all as specified & directed by Engr-in-charge .
S & F surface mouting PVC gang box of super quality for hopusing of one 15 Amp Switch & one1 5 Amp Socket incl suitable size of pvc sleeve & screews all as specified & directed by Engr-in-charge . as
S & F surface mouting PVC gang box of super quality for housing of two 5 Amp Switch & two 5 Amp Socket incl suitable size of pvc sleeve & screews all as specified & directed by Engr-in-charge .
S&F in repair white hylam sheet of thickness 1.3 mm incl cutting for housing ofswithces, sockets of size 9 x 6 inch incl suitable size of pvc sleeve & screews all as specified & directed by Engr-in-charge . as directed by Engr-in-charge
S&F in repair white hylam sheet of thickness 1.3 mm incl cutting for accommodate of mounting swithces ,sockets of size 5 x 5 inch incl suitable size of pvc sleeve & screews all as specified & directed by Engr-in-charge.
S&F in repair white hylam sheet of thickness 1.3 mm incl cutting for accommodate of mounting swithces ,sockets of size 8 x 5 nch.incl suitable size of pvc sleeve & screews all as specified & directed by Engr-in-charge .
S&F in repair white hylam sheet of thickness 1.3 mm incl cutting for accommodate of mounting swithces, sockets of size 9x 11 inch.incl suitable size of pvc sleeve & screews all as specified & directed by Engr-in-charge .
S&F in repair PVC pipe MG of size 25 mm dia,ISI Mark.incl fixing arrangement of suitable size ,all as specified & directed by Engr-in-charge .
S&F in repair PVC Casing & caping 25mm width , ISI Mark incl fixing arrangement of suitable size ,all as specified & directed by Engr-in-charge .
S&F in repair Brass machine screw with brass cup washer of size 1 inch long.all as specified & directed by Engr-in-charge
S&F in repair Brass machine screw with brass cup washer of size 2 inch long.as directed all as specified & directed by Engr-in-charge .
S & F in repair 5 -in-1, 6 Amp,240V, SS Combined unit with box (surface type) with indicator incl fixing arrangement of suitable size ,all as specified & directed by Engr-in-charge .
S & F in repair 5 -in-1, 6/16 Amp,240V, SS Combined unit with box (surface type) with indicator incl fixing arrangement of suitable size ,all as specified & directed by Engr-in-charge .
S & F 1100 volt heavy duty weather proof cable wiyh PVC insulated stranded aluminium conductor ,served with inner sheathing of PVC tape and overaii PVC Sheathed of size 16 sqmmx 2 core
S & F 1100 volt heavy duty weather proof cable wiyh PVC insulated stranded aluminium conductor ,served with inner sheathing of PVC tape and overall PVC Sheathed of size 10 Sqmm x 2 core
S&F PVC insulated & unshethed copper multisranded FRLS cable of size 1.5 sqmm with colour coding
S&F PVC insulated & unshethed copper multisranded FRLS cable of size 2.5 sqmm with colour coding
S&F wall mounted LED tube light fitting 1x20 watts polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core copper cable of suitable size fixed on wall/roof complete all as specified and directed.
S&F mirror light decorative compact luminaries with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with two core flexible copper conductor cable of suitable size
S&F of energy saving ,surface mounted, LED 10 watt Bulk head luminaire with decorative oval diffuser comprrising of high brightness LEDs complete all as specified and directed by Engr-in-charge.
Repair up-down mechanical adjustment with replacement of minor spare parts incl servicing complete for mini surgical OT luminiar, 65-67 VA, AC-100-240A, Model No.S300-A0000, Make:- Dentist Co limited.
Supply and fixing in repair round shape 12 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free down light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S& F Glaze in repair Wall Light including 9/10 watt LED lamp ( B22), 6500 K all as specified and as directed
Supply and fixing in replacement LED building security light fitting 30 Watt efficacy not more than 110 Lm/watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified incl taking out old u/s fitting complete.
Supply, fabricated and and fixing of street light bracket made out of 32 mm bore medium grade GI pipe made to shape with bolts, buts & washers of min 1.2 Mtr incl grouting of nuts or fasteners clamps and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable complete all as specified incl taking out old u/s fitting complete. Note: The unit rate include for painting to bracket with one coat of red oxide paint and two coat of alluminium paint before fixing.
Supply and fixing in repair LED luminaire 600mm X 600mm, 35/36 watt, efficacy not more than 100 Lm/watt, 220V AC Recessed type CCT 6500K with high efficiency PMMA diffuser soft glair free light complete with accessries suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing in repair LED luminaire 600mm X 600mm, 35/36 watt, efficacy not more than 100 Lm/watt, 220V AC surface type, 6500K with high efficiency PMMA diffuser soft glair free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing in repair LED Recessed Spot light 30 watt , at a height up to 20 meter from ground level model No CDR-214-30-30-SL-NWH forcommercial use long lift with 30000 burning hours with CRI<80, 30 watt, 3000K,CCT, Beam angle 36 degree vertical tilt 300 of dia 140 mm.
Supply and fixing in repair LED Recessed Spot light 45/50 watt , at a height up to 20 meter from ground level on false ceiling by making all safety arrangement and T & P, model No CDR-215-50-40-SL-NWH for commercial use long lift with 30000 burning hours with CRI- Ra>70, 12 watt, 4000K,, Beam.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 4 way with 100Amps rated bus bar. all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 100Amps rated bus bar. all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 415V AC 4 way with 200 Amps rated bus bar. all as specified and directed .
S & F vertical load line in sheet metal enclosures MCCB TPN DB's with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooing , IP-43 , TPN 4 way with 200 amps rated busbar, 440 volts, as per IS-8623 including taking out old UNSV DB and making good the disturbed surface of wall and match with the existing surface compelte all as specified and as directed. ( Note- MCCB 3 pole 63 amps as main incomer will be included in quoted rate)
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN ,240V AC 12 way with 100 Amps rated bus bar all as specified and directed .
Supply and fixing MCB SPN 20-32 Amp ,240 V AC 10 KA repturing capacity 'C' curve all as specified.
Supply and fixing MCB SPN 40 to 63 Amp ,240 V AC 10 KA repturing capacity 'C' curve all as specified.
Supply and fixing MCB SP 40 Amp ,240 V AC 10 KA repturing capacity 'C' curve all as specified.
Supply and fixing MCB 5 to 30 Amp ,10 KA repturing capacity 'C' curve complete all as specified.
Supply and fixing MCB TPN /FP 40 to 100 ,Amp 240 V AC 10 KA repturing capacity 'C' curve all as specified.
Supply and fixing MCB DP, 40 to 63 ,Amp 240 V AC 10 KA repturing capacity 'C' curve all as specified.
S & F Moduler Distribution box MCB Protected socket with Plastic enclosure ,Surface/concealed mounting, 20 Amp MCB DBOXX Combo DP including Plug top with indicator all as specified and directed.
Supply and fixing Distribution box Indostrial type single pole and neutral enclosure with a two pole and earth plug & socket complete with one, single pole MCB 20 Amps 10 KA repturing capacity 240 Volts AC all as specified.
Taking down old u/s cable & Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross - sectional area of 16 sqmm 4 core complete all as specified & as directed.
Taking down old u/s cable & Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross - sectional area of 35 sqmm 3.5 core complete all as specified & as directed.
Taking down old u/s cable & Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross - sectional area of 10 sqmm 2 core complete all as specified & as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out cables, pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
M & L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable ( measurement to be taken after punning down consolidated thick ness ). complete all as specified and as directed .
Supply and laying , un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmX 150mmX40mm with breaking load capacity 200 KG complete all as specified & as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engr - in - Charge.
M & L for 40 mm bore GI pipe (Light grade) laid under road or fixed with pole/wall of culvert as in protection of UG cable incl necessary MS clamp and complete all as specified and directed.
M & L for 50 mm bore GI pipe (Light grade) laid under road or fixed with pole/wall of culvert as in protection of UG cable incl necessary MS clamp and complete all as specified and directed.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable FRLSH) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in/on wall as per existing along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and directed
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/ concealed in /onwall as per existing along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and as directed Note:Two runs of phase , neutral wire and one run of earth wire will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable (FRLSH)1100Volts grade in existing conduit along with 4.0 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH)as earth wire and wire connected with main earth dolly including making good surfaces all as specified and directed Note:Two runs of phase , neutral wire and one run of earth wire will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 1.5 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/ concealed in wall as per existing along with 1.5.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and as directed Note:Two runs of phase , neutral wire and one run of earth wire will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 2.5 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/ concealed in wall as per existing along with 2.5.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and as directed Note:Two runs of phase , neutral wire and one run of earth wire will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 2.5 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including PVC Casing & Caping on wall as per existing along with 2.5.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and as directed Note:Two runs of phase , neutral wire and one run of earth wire will be measured as one RM or one length.
M&L for Earthing with GI electrode chemical advance maintenancefree chemical gel earthing electrode 50mm dia thick buried directly in ground vertically to a depth not less than 2.10 mtr below ground level filled with highly conductive metalic compound mixture CCM with the permanent sealing of the both end, outer dia pipe 50mm with strip terminal 50x6 with terminal holes incl one bag 25 kg of bfc compound, earth connected with earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board protected by galvanized iron pipe medium 15 mm bore, PVC chamber as per manufacturer instruction and testing on completion. Note: (i) Earthing has to done by CPRI approved firm and if the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item
Earth continuity conductor or main earthing lead of size 4mmdia galvanised iron fixed to wall on batten or recss or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other vindicared situation situation all as specified & directed
Comprensive maintenance and programming of Fire Alarm System inclding demo of fire alarm in presense of rep of section hospital and replacement of defective PCBs complete all as specified & directed
Supply ,Install & commissioning Anolog Addressable type self Acclimating multi sensing smoke detector with mounting base complete all as specified & directed
Supply ,Install & commissioning Manual calling point re-settable of fire complete all as specified & directed
S&F super quality white flexible PVC pipe of 25 mm dia,ISI Mark all as specified & directe
S&F metal box of thickness 1.2 mm and of size 7 x 4 inch including making good the disturbed surface as specified and directed by Engr in Charge.
S&F metal box of thickness 1.2 mm and of size 8 x 5 inch including making good the disturbed surface as specified and directed by Engr in Charge..
S&F metal box of thickness 1.2 mm and of size 4 x 4 inch including making good the disturbed surface as specified and directed by Engr in Charge.
S&F metal box of thickness 1.2 mm and of size 8 x 10 inch including making good the disturbed surface as specified and directed by Engr in Charge.
S&F Surface mounting or hanging with pipes & suitable fixing arrangement 1ft x 4 ft commercial/office luminaire CRCA housing ,36 watt,CCT 5700K,Efficacy not less than 100 lm/watt ,cat no BZSSLL36LEDWH I in Bajaj or equivalent Crompton/Philips as specified and directed by Engr in Charge.
S&F of LED tube rod 18/20 Watts single or double sided connections complete or with incl making connection alteration in existing tube light fitting complete
S & F vertical load line in sheet metal enclosures MCCB TPN DB's with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooing , IP-43 , TPN 12 way(36 module) with 250 amps rated busbar, 440 volts,with MCCB 160 Amp ,4P ,fixed magnetic type as incomer and MCB ,SP,40 Amp ,10 KA C Curve as outgoing incl connection with suitable size of lugs including taking out old UNSV DB and making good the disturbed surface of wall and match with the existing surface compelte all as specified and as directed. (Note-MCCB & MCBs will be included in quoted rate)
S& F Bus Bar Chamber total enclosed Matal Clad with protection insulator and coated tinned copper bus bar 100 Amp FP(R,Y,B & N) 415 Volt incl connections of alumn armoured cable /copper cable with suitable size/type of alumn/copper lugs complete all as specified and as directed.
S&F Uniquekly designed circular highbay luminair ,200 watt with 150 lm/w efficiency and 10 KV SPD and ingress protection of IP66 with additional safety chain complete at a height uptp 20 mtr from ground level all as specified and as directed.
S&F inreplacement of Meter Distribution board made out of polycarbonate of size 600x600x170 mm (dust proof & weather proof ,Shock proof, rust proof ,corrosion free ) with 230 V Ac 50 HZ 3 Wire , Gasket shall be embedded with T-locking arrangement and suitable for mounting of Electronic Meter -04/6 Nos with provision of clear transparent glass of as per meter installed incuding electrical connection with existing system and sealing properly & taking out u/s broken/rusted box of any size and type complete and making disturbed surface as per existing one all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
PARADISE INFRA POWER COMPANY (BID ID -3409101)
Bedi Refrigeration Works (BID ID -3409661)
Tarachand gurudutt (BID ID -3415727)
M/S ROORKEE ENGINEERING (BID ID -3408547)
Bhanu Prakash (BID ID -3409481)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .