Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.7 L+₹24,724 (0.90%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹35.0 L+₹7.6 L (27.5%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
17 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Bhamre Kiran S
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
REPAIR / REPLACEMENT OF MISC CONNECTED ITEMS RELATED TO ELECTRIC SUPPLY IN SARMAT RANGE AND OTHER CONNECTED AREAS AT AF STATION JAMNAGAR
2020_MES_377996_1
8750/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JAMNAGAR NO.1
₹50,000
Yes
24 Nov 2020
16 Sept 2020
19 Oct 2020
16 Sept 2020
17 Oct 2020
3 Oct 2020
60 days
Amount
Supply, installation, testing, & commissioning, factory made, CPRI approved, outdoor type, LT Panel board, compartmental type, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including Mild steel angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof, gasket, TPN bus bar shall be insulated with......
......colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated, internal wiring with PVC insulated multi-stranded copper conductor cable of appropriate size & length with fixing lugs, bolts, screws etc complete including taking down old panel, complete all as specified and directed by Engg-in-Charge & Consisting of the following switchgear:-
(a) Aluminium bus bar of size 300 amps for phase and 150 amps for neutral & shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on proper insulator etc including connection complete. - 01 set
(b) MCCB 160 Amps, 415V, 4 pole, 50Hz, breaking capacity 25 KA – 01 No (for incoming)
(c) MCCB 63 Amps, 415V, 4 pole, 50Hz, breaking capacity 16 KA - 01 Nos
(d) MCCB 32 Amps, 415V, 4 pole, 50Hz, breaking capacity 16 KA - 3 Nos
(f) LED indicator lamp with holder (Yellow, Blue, Red) – 01 set (Set of Three)
Supply, installation, testing, & commissioning, factory made, CPRI approved, outdoor type, LT Panel board, compartmental type, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including Mild steel angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof, gasket, TPN bus bar shall be insulated with.....
.....colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated, internal wiring with PVC insulated multi-stranded copper conductor cable of appropriate size & length with fixing lugs, bolts, screws etc complete including taking down old panel, complete all as specified and directed by Engg-in-Charge & Consisting of the following switchgear:-
(a) Aluminium bus bar of size 300 amps for phase and 150 amps for neutral & shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on proper insulator etc including connection complete all as specified and directed by Engg-in-Charge. - 01 set (b) MCCB 100 Amp, Breaking capacity 16 KA - 01 No.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised mild steel strip 25 x 4 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm.....
.....bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:-Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length.
Supply only Earthing Soil Resistivity improvement compound Gel, Enhancement compound Transparent Liquid Jel in 5 Kg packing all as specified and directed by Engr-in-charge. Make -JJ Engineering / JMV LPS Ltd / SM Infotech / Powertack
Material and labour for chemical earthing as per drawing attached (Sketch No 01). The chemical earthing will have specification as follows :- (a) Copper electrode of wall thickness minimum 2 mm not less than 3 mtr length with not less than 75mm outer dia .
(b) Fixing of copper Earth Electrode by drilling / boring 175 mm dia hole, 5.00 mtr deep in any type of strata, placing electrode in hole, return filling excavated soil by mixing min 10 kg GEL and 75 kg Soil Resistivity Improvement (SRIP) compound as per manufacturer instruction.
(c) FRP earthing result display board 254 x 380mm made out of plastic material showing information related to type of earthing, earthing result, due date of testing along with fixing size 610mm height made of plastic hollow pipe of dia 20 mm.
(d) PCC earthing pit in PCC 1:2:4 type B-1 of internal size 300 mm x 300 mm x 300 mm with 120 mm thick wall and 700 mm x 700 mm x 150 mm thick bed concrete and 50 mm thick precast chamber cover of RCC 1:2:4, type B1 for, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), complete all as shown in the electrical plate No 3 of SSR part –I complete. (e) Contractor must visit the site before quoting the tender to understand the difficulty and cost for carrying out the job in the station. It is important that contactor ascertain the quantum of work.
(f) Contractor must produce the certificate from the manufacturer that chemical earthing has been carried out by manufacturer. The manufacturer must also mention the warranty for chemical earthing. (g) Extension strip from electrode strip up to 0.15 m height from GL to be deemed included in quoted rate including brazing Make:- Powertrac / PRAGATI / McML's Earthing Solution (MES) / Ashlock
Supply in repair MCCB 63 Amp, Four Pole, breaking capacity 10 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified and directed by Engg-in-Charge.
Supply in repair MCCB 100 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
Supply in repair MCCB 125 Amp, Four Pole, breaking capacity 25 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
Supply in repair MCCB 160 Amp, Four Pole, breaking capacity 25 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
Supply in repair MCCB 200 Amp, Four Pole, breaking capacity 35 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
Supply in repair MCCB 315 Amp, Four Pole, breaking capacity 50 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
S&F in repair 3 Pole 185 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge
S&F in repair 3 Pole 95 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge
Supply and fix in repair GI earth strip of size 25 x 4 mm fixed on wall over and including epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal block complete all as specified & directed by Engr-in-Charge.
Supply and fix in repair Copper earth strip of size 20 x 3 mm fixed on wall over and including epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal block complete all as specified & directed by Engr-in-Charge.
Taking down carefully street light fittings (LED type light) any make and capacity for repair and refixing the in position after necessary repairing at same / different location, including provision of necessary T & P like ladder / Boom Veh, tools etc as required for taking down & refixing of Street light complete all as specified & directed by Engr-in-Charge.
Note:- Replacement of defective spare part for repairing of fitting will be measured & paid separately as supply & fix in repair.
S&F in repair Power Contactor 3 pole 32 amps, Aux contacts, 415V, 50Hz., fixed in position & connecting complete all as specified & directed by Engr-in-Charge. Make: L&T type MNX or equivalent of make C&S, BCH, Siemens
S&F in repair Analog type clock timer switch to set street light ON / OFF timing. Make: L&T / Legrand / Schneider
S&F in repair LED type building security light of capacity 30 watt white light with driver, having luminaries Efficiency not less than 100 lm / Watt, fixed in Pressure Die Cast Aluminum housing, & glass cover, Ingress protection of IP 65, including all necessary fitting & fixture,& connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair LED flood Light fitting 70 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified & directed by Engr-in-Charge.
S&F in repair LED flood Light fitting 120 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified & directed by Engr-in-Charge.
S&F in repair LED flood Light fitting 200 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified & directed by Engr-in-Charge.
S&F in repairs LED Street Light fitting 90 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as directed complete.
S&F street light bracket fabricated from 40 mm bore galvanised iron tubing light grade, 1.2 metre long, bent to shape fixed on pole / bldg including mild steel flat iron clamps, nuts, bolts etc including taking down old bracket from existing position complete all as specified & directed by Engr-in-Charge.
Supply & fix weather proof, PVC insulated, PVC sheathed, cable, with multistranded Aluminium conductor of size 2.5 Sqmm, 2 core, fixed from Junction box to street light fittings including taking down old cable.
S&F in repair LED Aviation obstruction light fitting die cast aluminium alloy housing, heat resistant, clear thick glass and accessories with LED chip & driver, fixed in position & connecting complete all as specified & directed by Engr-in-Charge. Make Bajaj Cat No BGAV 302 LED or equivalent of make mention in Appx B
S&F 20 mm dia PVC conduit ISI marked, heavy duty, fixed complete to walls /on pole with mild steel clamps, nuts and bolts complete all as specified & directed by Engr-in-Charge.
S&F in repair Sheet moulding compound (SMC) junction box of size 250 mm x 200 mm x 150mm, comprising three phase connector and one No MCB SP, 06 Amps C type, fixed on pole with mild steel clamps, nuts and bolts complete all as specified & directed by Engr-in-Charge.
Supply & laying 40 mm bore mild steel galvanised iron tubing light grade for protection of cable / earth continuity conductor etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing complete all as specified & directed by Engr-in-Charge.
Supply & laying 50 mm bore mild steel galvanised iron tubing light grade for protection of cable / earth continuity conductor etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing complete all as specified & directed by Engr-in-Charge.
Supply & laying 80 mm bore mild steel galvanised iron tubing light grade for protection of cable / earth continuity conductor etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing complete all as specified & directed by Engr-in-Charge.
Boring under roads / pavement / hard standing without disturbing the top surface by trench less technology using necessary machine including Supply & inserting HDPE pipe of 90 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified & directed by Engr-in-Charge. Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified & directed by Engr-in-Charge.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soil complete all as specified & directed by Engr-in-Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge.Note: for measurement purpose punned thickness of sand will be consider.
Taking out old PCC cable cover of any size / any type from trenches complete all as specified & directed by Engr-in-Charge.
Laying only PCC cable cover for LT UG cable, of any description retrieved from item No 37, complete all as specified & directed by Engr-in-Charge.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat of size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable complete all as specified & directed by Engr-in-Charge.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class HV , Type I , flat size 300 mm X 180 mm X 40 mm in trenches as protection to HT UG cable complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 2 core x 10 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 2 core x 16 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 4 core x 10 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 4 core x 16 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 3.5 core x 25 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 3.5 core x 35 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 3.5 core x 50 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 3.5 core x 70 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 3.5 core x 95 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable LT aluminium conductor UG cable of size 3.5 core x 185 Sqmm complete all as specified & directed by Engr-in-Charge.
Taking out Old unserviceable HT aluminium conductor UG cable of size 3 core x 95 Sqmm complete all as specified & directed by Engr-in-Charge. NOTE :- Earth work for taking out cable cover will be measured and paid separately.
Supply & lay UG XLPE insulated armoured heavy duty electric cable with Aluminium conductor 1100 V grade laid in trenches / passing through GI tubing / on pole / on wall etc. all as directed & specified of following sizes.
10 Sqmm 2 core
16 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
185 Sqmm 3.5 core
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, HT underground cable (earthned grade) ISI marked with aluminium multistranded conductor 11000 volt grade of size 95 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified & directed by Engr-in-Charge.
Note for Item No 41 to 52 (i) Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule. (ii) Straight through joint will be measured and paid separately.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 4 core, 10 to 16 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 25 to 35 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply, jointing, connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 50 to 95 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 to 240 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, HT 11000 Volts, aluminium conductor of 3 core, 95 to 120 Sqmm all as specified and as directed by Engineer-In-Charge.
Supply jointing connecting and testing, end termination joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, HT 11000 Volts, aluminium conductor of 3 core, 95 to 120 Sqmm all as specified and as directed by Engineer-In-Charge.
M&L for Repairing of 1HP capacity electric motor of high mast pole, AC 3 phase, by dismantling the motor cutting and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super insulated copper conductor winding wire, and varnishing complete including replacing the worn out bearing reassembling the motor fixing in same position and testing complete all as specified and directed by Engr In charge.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-21 of 9 M long all as specified and directed by Engg-in-Charge. including taking down old pole by cutting from ground level and dismantling of PCC coping.
M&L for PCC 1:4:8 Type D 2 using 40mm graded stone aggregate as in foundation, filling mass concrete complete all as specified & directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C 2 using 40 mm graded stone aggregate as in coping for PCC pole etc including finish the exposed surface even & smooth without using extra cement all as specified and as directed by Engg-in-charge
Taking down carefully ceiling fan / exhaust fan / cabin fan / wall mounted fan by disconnecting electric connection for repairing such as rewinding, replacement of defective spare part, over hauling and painting etc as required and re-fixing in the same position after carry out the repairs works, testing and connecting complete all as directed by Engr-in-Charge.
Note:- (i) Repairing such as rewinding, replacement of defective spare part, connecting wire etc will be measured & paid separately as supply & fix in repair (ii) Over hauling and painting will be measured & paid separately. (iii) After repair / replacement of worn-out parts, the fan will be tested to the entire satisfaction of Engineer-In-Charge and in case of failure of test, the same shall be repaired at contractor's cost.
M & L for rewinding of ceiling fan 1200 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enamelled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as specified & directed by Engr-in-Charge.
All as item No 64 above but exhaust fan 300 mm sweep.
All as item No 64 above but exhaust fan 450 mm sweep.
Supply and fix in repair ball bearing of any size of ceiling fan of 1200 mm
Supply and fix in repair capacitor 2.5 MFD AC 230 Volt 50 HZ, of ceiling fans.
Supply and fix in repair capacitor 4 MFD AC 230 Volt 50 HZ, of exhaust / bracket fan any size.
Supply and fix in repair rubber bush with clamp bolt, nuts, washer and split pin for the down rod of ceiling fan.
Supply and fix in repair PVC insulated, PVC sheathed three core copper conductor cable multi stranded of size 0.5 Sqmm for connecting of fan from ceiling rose complete all as specified & directed by Engr-in-Charge.
Taking down carefully aluminium point wiring complete of any type (batten / surface conduit for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces complete all as specified & directed by Engr-in-Charge.
Taking down carefully aluminium sub main wiring complete of any type (batten / surface conduit complete and making good disturbed surfaces complete all as specified & directed by Engr-in-Charge.
Taking down carefully by unscrewing from main switch boards/cut out boxes/MCB DBs / complete sealing the cable end and making good disturbed surface by walls etc.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC capping & casing not less than 25 mm wide, including all accessories like bend, tees, junction boxes etc......
...... including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC surface type terminal box of suitable size with PVC cover complete all as specified & directed by Engr-in-Charge.
All as per item No 75 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch.
All as per item No 75 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch.
All as per item No 75 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Supply and fix Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete all as specified & directed by Engr-in-Charge.
Supply and fix for Switch socket combination white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete all as specified & directed by Engr-in-Charge.
Supply and fix for Switch socket combination white polycarbonate body, 6A / 16A- 230 V, Multipurpose, including connecting complete all as specified & directed by Engr-in-Charge.
Supply and fix for Ceiling rose ceiling rose , 3 phase white polycarbonate body 6 Amps, 250 volts AC, including connecting complete all as specified & directed by Engr-in-Charge.
Supply and fix stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 20 watt, aluminium extruded channel (approximate length 1200 mm) housing & diffuser with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
Make:- Havells Cat No LHEWEBP7IN1W020 or equivalent of make mentioned in Appendix 'B'
S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 10 watt, aluminium extruded channel (approximate length 600 mm) housing & diffuser with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
Make:- Havells Cat No LHEWEBP7IN1W010 or equivalent of make mentioned in Appendix 'B'
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified & directed by Engr-in-Charge. Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified & directed by Engr-in-Charge.
Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
Material & Labour for sub main wiring with 4 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty rigid PVC conduit not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified & directed by Engr-in-Charge. Note: 4 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
S&F in repair energy efficient recessed mounted 18 watt LED luminaries suitable for round recessed with flat diffuser alongwith constant current electronic driver, UV resistance & polycarbonate cover complete all as specified & directed by Engr-in-Charge. Make:- Crompton cat No LSCRM-18W-CDL/NW/WW or equivalent of make mention Appx B
S&F in repair metal clad plug & socket board SP&N enclosure with 2 pole and earth metal plug & socket complete with 20 Amp MCB SP, C curve complete all as specified & directed by Engr-in-Charge.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified & directed by Engr-in-Charge.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified & directed by Engr-in-Charge.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way, vertical type with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, double door type 415 volts, fixed flush to wall complete all as specified & directed by Engr-in-Charge.
S&F Distribution board made out of sheet metal powder coated, factory made, enclosure, double door type, TPN 6 way with 200 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, including 1 Nos Incomer MCCB 125 Amp, triple pole and neutral, 415 Volts, 16 kA breaking capacity, fixing of DB flush to wall surface complete all as specified & directed by Engr-in-Charge.
Supply and Fix MCB’s single pole of 6 to 32 amp capacity, fixed in sheet metal board complete including connection complete all as specified & directed by Engr-in-Charge.
Supply and Fix MCB’s single pole & neutral of 6 to 32 amp capacity, fixed in sheet metal board complete including connection complete all as specified & directed by Engr-in-Charge.
Supply and fix MCB’s triple pole & neutral, 32 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s triple pole & neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in repair Energy efficient recessed mounted 24 watt LED luminaries (lumen efficiency not less than 120 Lumen / watt) suitable for 600 x 600 mm grid ceiling along with flat diffuser along with constant current electronic driver, IP 65 Protection, UV resistant & polycarbonate cover all as specified and directed by Engg-in-charge.
Supply and fix in repair 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor, including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor, including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair 50 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc laid in trenches, including taking down old pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repair gun metal gate valves of size 20 mm bore ISI marked with iron wheel head screwed both ends for iron pipe and fixed, complete all as specified & directed by Engr-in-Charge.
S&F in repair gun metal gate valves of size 25 mm bore ISI marked with iron wheel head screwed both ends for iron pipe and fixed, complete all as specified & directed by Engr-in-Charge.
S&F in repair gun metal gate valves of size 50 mm bore ISI marked with iron wheel head screwed both ends for iron pipe and fixed, complete all as specified & directed by Engr-in-Charge.
Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 30cm and averaging 15cm deep including sweeping removing the same to distance not exceeding 50m away from the LT pole all as specified and directed by Engr-in-Charge.
M & L for chequered cement concrete tiles 45 cm x 30 cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 15mm thick screed bed or bedding layer of mortor in cement mortor 1:4 with gray cement and pigment complete all as specified & directed by Engr-in-Charge.
M&L for painting of RCC / steel pole in alternate strip of 0.25 metre each with one coat synthetic enamel paint up to 1.5 meter height above PCC coping after preparation of old painted surface, writing pole No with black synthetic paint, complete all as specified & directed by Engr-in-Charge.
S&F in repair driver for LED street light 70 Watt of C&G / Wipro / Philips make suitable to same make & model of existing street light all as directed & as per site requirement.
S&F in repair driver for 600x600 ceiling LED Grid light of 24W / 36W of C&G / Wipro / Philips make suitable to same make & model of existing street light all as directed & as per site requirement.
SURESH ELECTRICALS
jagdish machinery stores
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .