Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹9.9 L+₹3,620 (0.37%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹11.0 L+₹1.1 L (11.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹11.5 L+₹1.7 L (16.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹11.8 L+₹1.9 L (19.0%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Jun 2023, 6:00 pmClosed
GE (KH) YOL
GE (KH) YOL, YOL CANTT, HP
Repair replacement of internal wiring and allied works of JCOs/OR Md Accn in Lower Garrison at YOL CANTT under AGE E/M of GE (KH) YOL
2023_MES_595699_1
GE/Y-14/2023-24
Open Tender
Civil Works
Item Rate
270 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (KH) YOL
₹40,000
Yes
6 Jul 2023
16 May 2023
14 Jun 2023
16 May 2023
12 Jun 2023
30 May 2023
Amount
PART-I:- Taking down point wiring with aluminium/ copper conductor for light point, fan & socket point/ power point etc. complete including light fiitings any type, switches, sockets, holders, (batten or pendent type), ceiling rose, switch board, bell/buzzer, bell push, tube light fitting, regulator etc. and making good to the disturbed surfaces of wall/ floor etc. to match with existing surfaces including white wash/ colour wash/ distempering to match with existing wall/ floor/ ceiling finishes and all as specified and directed.
Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surfaces, complete all as specified.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multi strand) PVC insulated ISI Marked unsheathed cable in and including concealed PVC conduit medium grade, ISI marked of suitable size with all fittings/ accessories and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as phase, neutral and earth wire connected to common earth dolly and including concealed pressed steel/ cast iron of suitable sizes terminal boxes made from 1.60 mm thick sheet for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet for one light point or one fan/exhaust fan point or one bell point, independent, controlled by one way switch/ push button complete all as specified and directed. Note:-i) Wiring colour code i.e Red/Yellow/Blue for phase, Black for neutral and Green for earth shall be maintained. (ii) Rate of cutting chases, cement plaster, white wash and making surface good as existing surface included in quoted rate.
All as per serial item No '03' above, but for one 3 pin 5 Amps socket outlet on the same board with 2.5 sqmm PVC copper conductor cable and PVC insulated, unsheathed 2.5 sqmm stranded copper conductor cable as continous earth wire, all as specified and directed.
All as per serial item No '03' above, but for one 3 pin 5 Amps socket outlet on the independent board with 2.5 sqmm PVC copper conductor cable and PVC insulated, unsheathed 2.5 sqmm stranded copper conductor cable as continous earth wire, all as specified and directed.
All as per serial item No '03' above, but for 3 pin 15 amps socket out let on independent with 2.5 Sqmm PVC copper conductor cable and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
All as per serial item No '03' above, but for one light point controlled by two way switchs.
M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC casing capping/conduit (ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable size including PVC junction box /MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated hylam sheet top cover (ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/ fan point controlled by one switch Note : (i) Wiring Colour code i.e. Red/Yellow/Blue for Phase, Black for neutral and Green for earth shall be maintained. (ii) Chase cutting if required shall be measured and paid separately under relevant items in this schedule.
All as per serial item No '08' above, but for one 3 pin 5 Amps socket outlet on the same board with 2.5 sqmm PVC copper conductor cable and PVC insulated, unsheathed 2.5 sqmm stranded copper conductor cable as continous earth wire, all as specified and directed.
All as per serial item No '08' above, but for one 3 pin 5 Amps socket outlet on the independent board with 2.5 sqmm PVC copper conductor cable and PVC insulated, unsheathed 2.5 sqmm stranded copper conductor cable as continous earth wire, all as specified and directed.
All as per serial item No '08' above, but for 3 pin 15 amps socket out let on independent with 2.5 Sqmm PVC copper conductor cable and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
All as per serial item No '08' above, but for one light point controlled by two way switchs.
Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified.
Switch piano flush type, single pole, two way, 6 Amps 230V, all as specified.
Switch piano flush type, single pole, one way, 6 Amps 230V, all as specified.
Switch piano flush type, single pole, one way, 16 Amps 230V, all as specified.
Socket outlet Two -in -One 3 pin 6 Amps flush type, 230 volts AC multipurpose, all as specified.
Socket outlet Two -in -One 3 pin 6 and 16 Amps flush type, 230 volts AC multipurpose, all as specified.
Fixed in repair ceiling fan regulator step type, electronic type on the existing phenolic laminated sheet etc. varying 5 Speeds 230 Volts, 50Hz, suitable for 1200/ 1400 mm sweep ceiling fans, all as specified.
Ceiling rose, three phase, PVC/Polycarbonate, insulated body, fixed in repair all as specified.
Switch, bell push, piano flush type, SP one way 5 Amps, fixed in repair all as specified.
Bell electric, ding dong AC 230V, single pole, fixed in repair, complete all as specified.
Switch piano flush type, single pole, two way, 6 Amps, fixed in repair, all as specified.
Switch piano flush type, single pole, one way, 6 Amps, fixed in repair, all as specified.
Switch piano flush type, single pole, one way, 16 Amps 230V, fixed in repair, all as specified.
Socket outlet Two -in -One 3 pin 6 Amps flush type, 230 volts AC multipurpose, fixed in repair, all as specified.
Socket outlet Two -in -One 3 pin 6 and 16 Amps flush type, 230 volts AC multipurpose, fixed in repair, all as specified.
Switch socket combination Two -in -One 3 Pin, 6 Amp Amp flush type, fixed in repair, all as specified.
Switch socket combination Two -in -One 3/5 Pin, 6 and 16 Amp flush type, fixed in repair, all as specified.
Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, fixed in repair, complete all as specified and directed.
Supply and fixed in repair LED Bulb 9 watt, cool/warm white 6500K/3000K, suitable for base B22/E27, 230V, complete all as specified and directed.
Supply and fixed in repair LED invertar Bulb 12 watt, cool/warm white 6500K/3000K, suitable for base B22/E27, 230V, complete all as specified and directed.
Supply and fixed in repair 3mm thick backelite sheet (hylam) as sheet cover with PVC Box of size 8''x10'' for fixing switches, sockets & regulators etc. Complet all as specified and directed.
Supply and fixed in repair 3mm thick backelite sheet (hylam) as sheet cover with PVC Box of size 7''x4'' for fixing switches, sockets & regulators etc. Complet all as specified and directed.
Supply and fixed in repair 3mm thick backelite sheet (hylam) as sheet cover with PVC Box of size 4''x4'' for fixing switches, sockets & regulators etc. Complet all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug top and socket complete with one double pole MCB 20 Amps, fixed in repair, complete all as specified.
Sheet metal enclosures factory made for DBs when MCBs to be used, single pole and neutral (double Door), 8 way, 240 volts with 200 Amp rated bus bar, incuding taking out old, all as specified.
Sheet metal enclosures factory made for DBs when MCBs to be used, single pole and neutral (double Door), 12 way, 240 volts with 200 Amp rated bus bar, incuding taking out old, all as specified.
Supply and fix distribution board iron clad TPN DB double door with IP-43 protection 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete and incl cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface, incuding taking out old, complete all as specified
M & L for vertical DB iron clad factory made TPN 4 Way, MCCB as incomer and MCB SP as out going, double door DB IP 43 protection level, incl Blanking plate, lugs etc complete and neutral link with one MCCB 4 pole 415V 100 Amps rating with rupture capacity 16KA incl connection, fixing flushed to wall, necessary grouting, making good with CM 1:4 and painted to match exisitng wall color, incuding taking out old, complete. (outgoing MCB will be measured seperately)
MCB SP 0.5 to 5 Amp, 240 Volts, 10 KA, C series including taking out old, all as specified. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
MCB SP 6 to 32 Amp, 240 Volts, 10 KA, C series including taking out old, all as specified. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
MCB SPN 32 Amp, 240 Volts, 10 KA C series including taking out old, all as specified. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
MCB SPN 63 Amp, 240 Volts, 10 KA C series including taking out old, all as specified. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
MCB TPN 63 Amp, 415 Volts, 10 KA C series including taking out old, all as specified. Note:- The connection to the MCBs shall be done through thimble/lugs do not direct wire shall be connected to MCBs.
S & F MCB, 4 Pole, 63 A capacity, 415 V, 10 KA, C series including taking down old MCB 4 Pole. Note: The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
S & F MCB, 4 Pole, 100 A capacity, 415 V, 10 KA, C series including taking down old MCB 4 Pole. Note: The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring. Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface casing caping medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring. Note :-(i) One run of PVC casing caping, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring. Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface casing caping medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring. Note :-(i) One run of PVC casing caping, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit.
Replacement of LED Decorative ultra slim square profile LED lighting integral type fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack, 10 watt LED, 230V, and making connection with 2 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete, all as specified and directed.
Replacement of LED Decorative ultra slim square profile LED lighting integral type fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack, 20 watt LED, 230V, and making connection with 2 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete, all as specified and directed.
Supply and fixing of 30 Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens enbedded PC cover having TOP opening seperate toughtned glass/verminproof driver compartment, SPDs with IP66 protection and impact resistance of IK07, suitable for pole dia 43mm (max) connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of size 32mm dia lenght 1.2m along with clamps, including taking down old light, complete all as specified and as directed.
Supply and fixing decorative wall lighr fixture made up of polycarbonate, with 9W LED lamp B22 base complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, including taking out old light, complete all as specified and directed.
Material and labour for PVC Casing & Caping of size (20 x 12) mm ISI Marked suitable for electrical wiring complete all as specified incl taking out old and directed.
Material and labour for PVC Casing & Caping of size (25 x 16) mm suitable for electrical wiring incl taking out old complete all as specified and directed.
Material and labour for UPVC electrical conduit pipe of size 20 mm dia (heavy duty) Ivory color ISI marked suitable for electrical wiring including junction box, tees and bends etc incl taking out old complete all as spd and directed.
Material and labour for UPVC electrical conduit pipe of size 25 mm dia (heavy duty) Ivory color ISI marked suitable for electrical wiring including junction box, tees and bends etc incl taking out old complete all as spd and directed.
Material and labour for PP Corgulated flexible Conduit pipe of 16 mm dia suitable for internal wiring incl taking out old complete all as specified and directed.
Material and labour for PP Corgulated flexible Conduit pipe of 20 mm dia suitable for internal wiring incl taking out old complete all as specified and directed.
Material and labour for PP Corgulated flexible Conduit pipe of 25 mm dia suitable for internal wiring incl taking out old complete all as spd and directed.
Material and labour for electrical round sheet PVC material used for covering junction boxes, fan mounting and other electrical opening on wall incl taking out old complete all as spd and directed by Engr - in - Charge.
Supply and fixing in repair MCB Protected socket (modular AC box) 3 Module with MCB SP of capacity 25 Amp and power socket for geyser complete all as spd and directed by Engr - in - Charge.
M & L for rendering 15mm thick in cement mortar 1:6 on internal fair faces of brick walls or on concrete surfaces, finished even and smooth with using using extra cement complete all as specified and as directed.
Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of 2mm thick wall care putty preparatory to distempering including preparation of surface complete, all as specified and as directed by Engr-in-Charge
Supply and fix Automatic cover/ under voltage monitor and control relay having adjustable setting and overload protection with auto reconnect of electric supply with LED display voltage and current capacity (voltage range: 145-500 volts), complete all as specified and directed.
Material and labour for repair of wooden/ metal box fitted on site for protection of 2 to 4 Nos meter boxes / DB Boxes by dimentling existing unsv hinges, doors and locking arrangements and other part etc and replacing with new hinges, doors, locking arrangements and other parts as required at site and directed by Engr- in- Charge including painting the complete box with paint as directed by Engr - in - Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 m long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work.
S K MAHAJAN
M/S THAKUR ENTERPRISES
M/S PUSHPINDER ENGINEERS
RIHANA ENGINEERS
M/S HIMANSHU BUILDERS
Eshaan Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .