Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 CrAccepted-AOC UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹44.5 Cr | L1 | Accepted-AOC L1 and reasonable |
| 2 | L2₹46.5 CrRejected-Finance | ₹46.5 Cr | L2 | Rejected-Finance other than L1 |
| 3 | L3₹48.9 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹48.9 Cr | L3 | Rejected-Finance other than L1 |
| 4 | L4₹49.2 CrRejected-Finance | ₹49.2 Cr | L4 | Rejected-Finance other than L1 |
| 5 | L5₹50.2 CrRejected-Finance | ₹50.2 Cr | L5 | Rejected-Finance other than L1 |
Tender Value
₹44.7 Cr
EMD Value
₹15 L
Closing Date
18 Jun 2022, 6:00 pmClosed
Chief Engineer Navy
Chief Engineer Navy Station Road Visakhapatnam 04
PROVISION OF 144 NUMBERS OF SAILORS MARRIED ACCOMMODATION AT VISAKHAPATNAM
2021_MES_488345_1
85395
Open Tender
Civil Works
1170 days
VISAKHAPATNAM
as per NIT
9 documents required · 9 mandatory
₹3,000
Yes
₹15 L
Yes
Chief Engineer Navy Station Road Visakhapatnam 04
2 Jul 2022
15 Nov 2021
20 Jun 2022
15 Nov 2021
18 Jun 2022
13 Jun 2022
16 Nov 2021 - 25 Nov 2021
23 Nov 2021
Amount
Schedule "A" Part – I to Schedule "A" Part – XVI: NOTE: Schedule "A" Part – I to Part – XVI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II .
Lumpsum price worked out by the contractor for " PILE FOUNDATION" as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "ROADS /PATH/HARD STANDING/CULVERT", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "COMPOUND WALL/ FENCING" as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "FIRE ALARAM and DETECTION", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM ", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "PVC CONDUIT ", as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "AVIATION LIGHT", as listed in Schedule "A" Part – XVI
Schedule "A" Part - XVII [Miscellaneous Items]
PILE FOUNDATION
Boring for bored cast in situ piles 600mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 600mm dia in hard rock & fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Carrying out initial load test on 600mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out routine load test on 600mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out lateral load test on cast in situ piles 600 mm dia piles as specified in IS and directed by Engr - in- Charge.
Carrying out pull out test on cast on situ piles 600 mm dia pile as per specified in IS ,complete all as specified and directed by Engr - in- charge.
Carrying out low strain integrity test on bored cast in situ piles including analysing the result as per ASTM D 5882 and as directed by Engr - in- Charge.
Chipping out pile up to cut off level including disposal up to a distance outside MD land all as specified and directed.
COMPOUND WALL /FENCING
Supply and Fix chain link fencing of mesh 50 x 50 mm made out of 10 gauge dia mild steel wire over PVC coating to make overall dia as 6 gauge including GI binding wire and fixing of MS round bar as line wire for holding chain link mesh complete all as specified and as directed ( Note :- MS round bar as line wire shall be measured and paid separately as supply only ).
INTERNAL WATER SUPPLY
S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed suitable for 15mm CPVC pipe. Note: The maximum flow rate/consumption should be 3 LPM
S&F Bib taps two way, fancy type CP screwed down for size of 15 mm dia. Note: The maximum flow rate/consumption should be 3 LPM
S&F health faucet chromium plated, fancy type with steel flexible pipe complete of size of 15 mm dia. Note: The maximum flow rate/consumptio should be 3 LPM
INTERNAL ELECTRIFICATION
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module plate top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by one switch complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one bell point controlled by one bell push complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one fan point controlled by one point complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 6 Amp socket on independent board complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 6 Amp socket on same board complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 15 Amp socket on independent board complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by two number two way switch complete all as specified and as directed.
S & F LED adore lamp for AC 240Volt supply, including B22 type bulb holder ,CDS five star, 10 watts of five star rated complete all as specified and as directed.
S & F Energy efficient LED tube light fitting suitable for mirror light with tube 5 watts or nearest size, 240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and directed.
Supply and fixing Energy efficient LED tube light fitting with tube 9/10 watts or nearest size ,240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and directed
S & F Energy efficient LED tube light fitting with tube 20 watts or nearest size, 240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and directed.
S & F LED Security light fitting with tube 30W new generation energy saving & environmental friendly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.0 Sqmm copper conductor cable upto connector including 1.5 m long GI tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. complete all as specified and as directed.
S & F Ceiling fans AC single phase 230V of size 1200mm sweep, copper wound with complete set of fixtures such as canopy, down rod etc. , 5 star rating, metallic body complete with and inclusive of making necessary electric connections from ceiling rose to fan through twin core flexible wire all as specified and directed.
S&F Exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the disturbed surfaces etc. complete with and inclusive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
S&F Exhaust fan 300 mm sweep, metallic body (Heavy duty),900 RPM, complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of necessary opening, fixing and making good the disturbed surfaces etc. complete with and inclusive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
S&F Sub main wiring with 4 runs of single core 16 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit of suitable size with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including one run of 16 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. (Bus bar trunk/MCCB to VTPN DB of each floor). Note: 4 runs of 16 Sq.mm, 1 runs of 16 Sq.mm & one run of PVC Conduit of suitable size will be measured as one unit
S&F Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, of suitable size with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 6 Sq.mm, 1 runs of 6 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit
S & F Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit of suitable size with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 2.5 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 2.5 Sq.mm, 1 runs of 2.5 Sq.mm & one run of PVC Conduit of suitable size will be measured as one unit
S & F Sub main wiring with 2 runs of single core 4Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, of suitable size with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 4 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 4 Sq.mm, 1 runs of 2.54 Sq.mm & one run of PVC Conduit of suitable size will be measured as one unit
Supply and fixing single phase electronic Energy meter tamper proof with LED display, 240 volt , 50Hz AC supply, 10 to 30 amps capacity complete all as specified and as directed.
Supply and fixing prefabricated meter box made out of 2mm thick CRCA sheet duly powder coated of approx. size 40cm x 50 cm to accommodate 4 Nos single phase energy meter , front portion of the meter box to be provided with six opening to take the reading of energy meter and the six slit is to be covered/fixed with glass, necessary sunmica sheet of suitable size to be provided inside the meter box to fix the energy meter, with locking arrangements complete including sealing of energy meter all as directed and as specified. Note: Energy meter shall be measured and paid separately.
Earthing complete with copper plate electrode 60 cm X 60 cm X 3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip of 20mm x 3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe light grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer, charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC work complete all as specified and directed. (item caters for Internal Elec)
EXTERNAL WATER SUPPLY
Material and Labour for laying of Ductile pipe with spigot and socket end centrifugally cast(spun) class K-9 of 150 mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces, including testing and commissioning all as specified and as directed.
Construction of masonry valve chamber for 150 mm dia valve including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastering internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type C1 coping 50 x50x6 mm angle iron 6 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as shown on drawing and as specified.
Cutting existing DI pipe line for alterations or additions necessarily done in position without taking down and inserting T of 100 x 100 x 100 mm and Tee for tapping all as specified and directed.
Supply, install, testing and commissioning of centrifugal pump set with minimum ratings not less than 15 HP , 70 Mtr Head , 10 LPS with delivery size of 80 mm bore, with 4 pole, 415 Volts, 50 Hz, AC 3 Phase supply, electric driven, inclusive of air valve at delivery, pressure guage, star delta starter for pumps along with cabling by XLPE Copper cables from starter to Pump set with cable tray and PCC foundation. all as specified and directed .
Supply and fix flanged end lift type Foot valve 100 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
ROADS /PATH/HARD STANDING/CULVERT
Granular sub Base (GSB) with grading V of 150mm thick Compacted thickness (laid in two layers of 75mm each, Compacted separately) confirming to grading as specified, spread, rolled and consolidated to required gradient sand camber complete using necessary mechanical paver/ Grader and vibratory soil compacter of Capacity 8-10 ton all as specified and as directed. (a) Pavement shall be made for solid quantity arrived after consolidation. (b) Compaction of granular sub base filling shall be carried out under Optimum moisture condition to achieve 98.50 modified density. (c) Curing shall be carried out as per IRC recommendations. (d) Before execution of this item the approved material obtained from outside MD land shall be tested/ checked for suitability to use.
(e) The lead/ Royalty involved is to be ascertained by the contractor before quoting his tender and no extra payment/ Adjustment for increased in lead or Rate of Royalty due to whatever reason shall be admissible on his account. (f) Contractor shall use Vibratory earth compactor in lieu of Power roller to achieve 98.00% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. (g) GSB shall be as per MORTH specification as detailed in Particular specification.
Wet mix Macadam of 250mm thick (Compacted thickness) laid in three equal layers compacted separately with Coarse aggregate of specified grade spread rolled and consolidated to required gradient and camber complete using mechanical paver/ Grader and Random Vibrator of capacity of minimum 8-10 Tons at OMC to achieve at least 98% MDD determined using modified Proctor density determination method as per IS code on prepared GSB surface complete all as specified and as directed. Note : 1. The rate quoted shall be for 250mm compacted thickness. 2. Each layer shall be rolled separately.
M & L for Painting lines, dashes, arrows, letters, etc. on road surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause. 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 Degree centigrade Celsius, including cleaning and drying the road surfaces to ensure dust, oil, grease and moisture free surface before applying paint complete all as specified as directed.
SEWAGE DISPOSAL
M&L for 150mm Dia DWC HDPE pipes, Single socketed, in any length with rubber ring joints with collars, laid in trenches or in floors complete all as specified and as directed.
M&L for 200mm Dia DWC HDPE pipes, Single socketed, in any length with rubber ring joints with collars, laid in trenches or in floors complete all as specified and as directed.
Material and Labour for Ductile iron 100mm pipe class K-7 spigot and socket complete all as specified and as directed.
Supply and installation non clogging vertical sewage disposal submersible pump 600 LPM, 10m head, 5.0 HP with chrome steel impeller , including supply, installation with guide rail and lifting chain, cables, Earthing, testing complete all as directed
Supply and fixing electric submersible copper cable of size 6.0 sqmm ,3.0 core 415 V, complete all as specified and as directed.
Supply, installation, testing and commissioning of star delta type starter panel with steel enclosure for submersible pump, 415 V, 10 HP capacity all as specified and as directed.
Material and labour for rubber tyton joint suitable for 100mm dia DI pipe complete all as specified
Material and labour for ductile iron fittings such as elbows, bends, reducers, taper pieces complete all as specified.
EXTERNAL ELECTRIFICATION
XLPE insulated and screened insulated, FRLS armoured and PVC bedded underground HT cable, ISI marked with aluminium stranded conductor 11000 Volt grade (heavy duty) of size 3 Core, 120 Sq.mm cross section conforming to IS-7098 (Part-II) laid in trenches, fixed to walls or passing through pipes and connecting up complete all as specified and directed.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 240 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and directed. .
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 150 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and directed. .
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 120 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and directed. .
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core, 25 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and directed.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 16 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and directed. .
Supply, install test and commissioning of outdoor type SF6 insulated switchgear panel as per IEC 62271-200. 11 KV 630A 21KA/3sec ,right side extensible 4 way RMU floor mounted with internal copper bus bars, consisting of 1 No motorized Load Break Switch 630A as incomer and 3 Nos of fixed type Vacuum circuit Breaker module with Air insulated metering modules with earthing and 1 No Dummy box as outgoings. CTs shall be of CTR 50-25/1-1A of class 5P 10, 2.5 VA, STC 21 KA/1 sec. All live parts, bus bars LBS/VCBs connections of RMU shall preferably be enclosed in one tank to avoid multiple interconnections & sealed for life in robotically welded non-magnetic and non-ferrite grade stainless steel tank Grade 304 of minimum 2.5mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer. Bushings shall be bolted type top mounted outside the tank for connection of external bus bar. Also, the outer enclosure shall cover the full length of the switchgear, to ensure IP3X+IP54 protection for cable boxes.
The unit shall be internal arc proof 21kA for 1 sec for tank+ cable box and tested and totally safe for human beings. The gas released & personnel safety with internal arc proof shall not depend on plinth design. The release of gas to be from the top of the unit, so that, even if the person is operating the unit, opening the cover & there are personals near the sides of the RMU/plinth, top release will ensure their safety. The release in no case should be from any side or bottom of the unit, as the same is unsafe for the operating personnel/pedestrian or general public. Bidder shall provide type test report to prove compliance to the ‘Internal fault IAC-AFLR as per IEC 62271-200. Internal arc proof & testing shall be done with enclosure door in open condition, with switching devices in operation mode.
Supply fixing and testing of LT Panel board (Distribution Panel) made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated from the switchgear, and the nuts/ bolts etc. used are to be made of rust proof material including as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1000 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:-
INCOMING:- a) ACB 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 630 Amps, 50 KA - 01 Nos OUTGOING: - a) MCCB 4 Pole, 415 V, Adjustable type, 300 Amps with breaking capacity 36 KA-03 (02 for 02 blocks, 01 spare)., (b) MCCB 4 pole, 415V, Adjustable type 200 Amps with breaking capacity 36 KA-02 Nos ( 01 for DG Supply AMF Panel,01 spare) (c) MCCB 4 pole, 415V, Adjustable type 160 Amps with breaking capacity 36 KA-01 No (for APFC Panel), (d) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc. with all connected CTs., (e) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
Supply fixing and testing of LT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated from the switch gear, and the nuts/ bolts etc. used are to be made of rust proof material including as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following (DG Supply Panel):- INCOMING:- a) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA-01 ( from DG Supply AMF Panel) OUTGOING: - (a) MCCB 4 pole , 415V, Adjustable type, 63 Amps with breaking capacity 16KA-03 Nos (02 No's for Lifts Machine room Block 1& 2, 01 No for fresh water pumps Panel) (b) MCCB 4 pole , 415V, Adjustable type, 125 Amps with breaking capacity 25KA-01 No ( for Fire fighting pumps Panel),
Supply fixing and testing of LT Panel board (Distribution Panel PLC controlled) made out of CRCA sheet 2.00 mm thick indoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated from the switchgear, and the nuts/ bolts etc. used are to be made of rust proof material including as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Pump House Panel) Note:-Rate quoted is inclusive fixing two no's starter in panel of fresh water pumps.LT panel should be spacious for fixing 02 no's starters for fresh water pumps.):-INCOMING:- a) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA-01 OUTGOING: -a) Supply and fixing DOL starter 10 HP-02 Nos (02 for booster pumps.)(b) MCB SPN, C-Curve, 32 Amps ISI marked, 50 Hz 220 Volts grade-02 for misc. loads. (c) MCCB 4 pole , 415V, Adjustable type, 32 Amps with breaking capacity 16KA-05 Nos ( 02 Nos for Block 1, 02 Nos for Block 2, 01 No for Street lights). (d) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc. with all connected CTs. (e) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
Supply fixing and testing of LT Panel board made out of CRCA sheet 2.00mm thick indoor pedestal type totally enclosed with front and rear opening , hinged doors with projected in raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, cable connector for connecting multi cables located in chamber terminated from the switchgear, and the nuts/bolts etc. used are to be made of rust proof material including as per is:8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50Hz 415 V 300A capacity complete with powder coating, necessary material electric connection as required and provision of the following : (Fire Fighting pumps Panel) INCOMING :- (a) MCCB 4 pole, 415V, Adjustable type , 125 Amps , with breaking capacity 25KA-01 OUTGOING :- (a) Star delta starter with relay suitable for 80HP- 01 No. (b) DOL starter 6HP- 01 No (c) MCB SPN, C curve, 32 Amps -01No., (c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kwh etc. with all connected CTs. (d) LED indicating lamps with colour Red, Yellow, Blue -01 Set
Supply and fix bus bar trunking system for the complete building power supply duly insulated three phase of rating 160 Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 0.8mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 160 A 25 KA 4P with rotary handle, termination links of building including following (Job of 4Nos): A. Vertical rising trunking system of rating 160 Amp
Supply and fix Straight feeder of Bus bar trunking system as specified and directed.
Supply and fixing of Flange end of Bus bar trunking system as specified and directed.
Supply and fix End Cover - 01 Nos(for main riser) of Bus bar trunking system as specified and directed.
Supply and fix Brackets of Bus bar trunking system as specified and directed.
Supply and fix Springs support Hangers of Bus bar trunking system as specified and directed.
Supply and fix Fire barrier complete for BBT of Bus bar trunking system as specified and directed.
Supply and fix Adaptor box of Bus bar trunking system as specified and directed.
Supply and fix Copper braided flexibles complete for BBT of Bus bar trunking system as specified and directed.
Supply and fixing of External GI strip 32 x 6 mm of Bus bar trunking system as specified and directed.
Supply and fix 63A 4P lightening trunking 63 Amp ,horizontal for each 3.00M length per floor of Bus bar trunking system as specified and directed.
Supply and fix Flexible elbow as required at site of Bus bar trunking system as specified and directed.
Supply and fix Horizontal elbow as required of Bus bar trunking system as specified and directed.
Supply and fix MS 100A Centre feed Unit IP 55 of Bus bar trunking system as specified and directed.
Supply and fix 63 A TAP OFF Box Provision for MCB of Bus bar trunking system as specified and directed.
Supply and fix End cover for 63 A feeder of Bus bar trunking system as specified and directed.
Supply and fix MS Sleeve IP 55-10 Nos of Bus bar trunking system as specified and directed.
Supply and fix MS Plug point Gasket IP 55-10 Nos of Bus bar trunking system as specified and directed.
Supply and fix suspension Bracket of Bus bar trunking system as specified and directed.
Supply and fixing LED street light fitting 70/75W 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optical complete with IP 65/66 protection
Supply and fix solar street light 36/50 Watt, smart integrated all in one street light with highest ever system efficiency 170 Lumen/Watt, MPPT charge controller, battery, mono crystalline solar panel, PIR motion sensor, easy installation.
Loop in loop out box (minimum size-200mm x 160mm x 98mm)of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. all as specified and directed.
Earthing complete with Galvanised iron earth plate electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6 mm GI earth strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m in length from earth plate, Earth Plate Electrode surrounded by 150 mm thick packed layers of Charcoal and Rock Salt filled in alternate layers, connected to the plate by means of brass Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Rock Salt, PCC chamber [1:3:6, Type C1] with RCC cover of 1:2:4 type B1 , MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
M & L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and fix time switches 415 V ,50 Hz of 20 Amp rating with contactor Fitted inside steel enclosure all as specified and as directed
M & L for PVC sheathed cable aluminium conductor of size 2.5 sqmm 2 core laid in ground fixed to wall roof etc. with suitable clamps spacers bolts, nuts etc. Complete all as specified and directed.
Material and labour for cable root indicator made out with 300x300x300 mm thick PCC Block of 1:3:6 type C1 by using 20mm graded aggregate and embossing HT indicator made out with MS /CI round shaped sheet welded with 200mm long MS flat iron including 2 coats of synthetic enamel paint over one coat of red oxide primer to iron surfaces fixing at different cable routes complete all as specified and directed by Engineer in charge
PVC CONDIT
Supply and fix telephone sockets(Jack type) RJ 11-1 with shutter 1 module complete complete with all accessories all as directed.
Supply and fix TV co-axial socket 1 module complete with all accessories all as directed.
Supply and fixing RJ-11 Telephone line cable all as specified and directed
Supply and fixing RG-6 Coaxial TV antenna wire all as specified and directed
DG SET
(A) Alternator :- Standard design alternator rated at 125 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722., i) Insulation class - 'H‘., ii) Temperature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%.,
(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- i)Fly wheel with housing., ii) Cooling system :- Moulded radiator with fan & belts., iii) Cooling Water pump : - Centrifugal type belt driven., iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold
Silencer : Residual type Bellows., iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lubricant oil System : -Lubricating oil filter ,Lubricating oil pump. vi) Air Intake System : Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator., ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch
Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan., Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel., x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. xi) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine., xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling., xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms. xv) Fuel Tank :- Additional Fuel Tank of capacity to suit Daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the acoustic enclosure., xvi) MS pipe line to and from the fuel tank to the DG Set.
D) Acoustic Enclosure:- Manufactured by OEM suitable for 125 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board., (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Blank. (v) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms., vi) The acoustic should be composite in construction and fully assembled integral unit., vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form viii) The fuel tank is to be located inside the enclosure., ix) The DG Set should be provided with external Emergency stop push button x) The enclosure should be suitably illuminated by LED Lamp fittings.
xi) The noise level should be 75 dba at 1m under free field conditions., xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade. E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 3.0 x 0.8 m for placing of DG Set complete all as specified and directed.
LIFTS
d) Four sleek circular 5 Watt LED light fitting in false ceiling. e) Two sleek circular PVC low noise fan in false ceiling. f) Aluminium chequered plate (3 mm thick) as flooring joint in chequered plate should not more than one and top covering with granite flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping system having relays etc. (overload protecting / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish. l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Specification plate with complete details.
o) Continuous earthing for machine and equipment's. p) Steel wire rope of adequate size as per relevant IS and as per manufacturer specifications. r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes, control panel, locks, governor, car operational panel, power, control and trailing cables completes) Full length display indicator panel. t) Main drives and control shall be of latest, high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage. v) Stainless steel front opening type landing door with small opening for vision of size 200 mm x 800 mm with toughened glass not less than 8mm thick. w) Intercom be connected with nearest security post.
(a) Fire man switch. (b) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load., (c) Battery operated emergency light (Led ceiling fitting), alarm (Speaker for emergency alarm system with calling/ announcement/alarm, receivers at ground floor and lift machine room to be fixed) and stop button in car with rechargeable arrangement for battery. (d) Four sleek circular 5 Watt LED light fitting in false ceiling . e) Two sleek circular PVC low noise fan in false ceiling.
f) Aluminium chequered plate (3 mm thick) as flooring joint in chequered plate should not more than one and top covering with granite flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping system having relays etc. (overload protecting / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish. l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Opening with mirror of 5mm thick 200 x 800 mm size in all the doors (Car/Landing doors). o) Specification plate with complete details .
p) Continuous earthing for machine and and equipment earth strip upto body of equipment as per IS specification. q) Steel wire rope of adequate size as per relevant IS and as per manufacturer specifications. r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes, control panel, locks, governor, car operational panel, power, control and trailing cables completes) Full length display indicator panel. t) Main drives and control shall be of latest, high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage. v) Stainless steel front opening type landing door with small opening for vision of size 200 mm x 800 mm with toughened glass not less than 8mm thick. w) Intercom be connected with nearest security post.
Note for LIFTS :- Cost of comprehensive/periodical maintenance of Lifts including spare parts during defect liability period is deemed to be included in the rate quoted for the lift item under Phase- III
AVIATION LIGHT
Cable PVC insulated armoured PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps spacers bolts, nuts etc. Complete all as specified and directed.
Aviation obstruction light LED type Filament-less bulb of 10 Watt complete including standard fixing arrangements complete all as specified and directed.
Loop in loop out box (minimum size-200mm x 160mm x 98mm)of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc. all as specified and directed.
FIRE FIGHTING SYSTEM, FIRE ALARM AND DETECTION
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directed.
Supply, installation, testing and commissioning of DOL starter panel with steel enclosure for SIREN, 415 V, 2 HP capacity all as specified and as directed.
Material and Labour for laying of Ductile pipe with spigot and socket end centrifugally cast(spun) class K-9 of 150 mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces, including testing and commissioning all as specified and as directed.
GEYSER
Supply, installation, testing and commissioning of geyser electric driven (single phase), PVC body having capacity of 15 litre of 5 star rated with flexible stainless steel branded water pipe 450 mm long along with nuts on both ends and including all accessories complete all as specified and directed.
SOLAR PANEL INVERTER
Supply, fixing and commissioning of solar panel powered inverter (Sine wave ) with battery backup for 8 hours of capacity 02 KW (Single phase 230 Volt, 50 Hz AC supply complete (off grid type) with and inclusive of electrical and mechanical accessories & stand for inverter and batteries. Note: (i) Solar panel of specification 320 Wp ( Minimum) polycrystalline type to be provided. (ii) Invertor and battery backup shall be placed near lift operator room or near lift store room. (iii) Tubular battery of 12 Volt, 150 AH of sufficient quantity to be provided and rate quoted shall deemed to be included the cost of battery. (iv) 15 Amps switch socket combination with necessary manual changeover switch 32 Amps single phase, 240 volt, to be provided near inverter for switching on to normal electrical supply in case solar system fails 15 Amps Switch soscket combination shall be paid through under relevant item in internal electrification schedule and cost for change over switch deemed to included in the rate quoted. (v) Solar inverter supply will feed the supply to light fittings of ground floor parking area, building security lights, passage lights of each floor stair case lights of each floor and security lights provided in the roof top of the building. (vi) Sub main wiring from inverter to MCB DB of each floor and point wiring for parking area lights, security lights fitted in building, light fittings in passage of each floor and staircase shall be measured under point wiring in internal electrification schedule. (vii) Before carrying out the work, contractor shall submit wiring diagram for approval by Engr-in-charge.
ARBORICULTURE
Supply & Planting carpet Grass by piece turfing including preparation of ground upto 30 cm deep and filling soft soil, cow dung and watering etc. complete all as specified and directed. Note: Loose soil and cow dung shall be measured and paid separately UNDER SUPPLY ONLY.
Supply only approved loose soil of best quality for plantation.
Supply only approved manure (Cow dung) of best quality for plantation.
Supply only approved vermi compost of best quality.
Supply and plantation of Ravi/Neem (height of plant not less than 2.0m above ground level) including preparation of ground up to 560cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed by the Engineer-in-charge.
Supply and plantation of Guava of height not less than 1.50 m above ground level) including preparation of ground up to 560cm deep and filling of good earth, cow dung vermi compost and watering etc. complete all as directed by the Engineer-in-charge.
Supply and plantation of Drought tolerant plant including preparation of good earth, cow dung vermi compost and watering etc. complete all as directed by the Engineer-in-charge.
Supply and laying 25mm bore GI tubing medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply and laying 15mm bore GI tubing medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
S&F 25 mm bore dia of pipe Gun Metal Globe or Gate Valve of Class – I Pressure Tested of 1.5 Mpa with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all as specified.
S&F 15 mm bore dia of pipe Gun Metal Globe or Gate Valve of Class – I Pressure Tested of 1.5 Mpa with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all as specified.
S&F 15mm dia Sprinklers complete all as specified.
MAINTENANCE OF ARBORICULTURE
Material and labour for maintenance including watering and fertilization of all the grass/plants/trees by weeding housing saucer melding once in every 15 days, planting new plants/grass spices and height with out any extra cost to the department for period of maintenance period of two years from the completion date of project complete all as specified and directed.
COMPREHENSIVE MAINTENANCE OF LIFTS
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+9 upper floors of 2Nos of lifts all as mentioned vide SI No. 136 of Sch "A" Part - XVII during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+9 upper floors 2Nos of lifts all as mentioned vide SI No. 139 of Sch "A" Part - XVII during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+9 upper floors 2Nos of lifts all as mentioned vide SI No. 136 of Sch "A" Part - XVII during 2nd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+9 upper floors 2Nos of lifts all as mentioned vide SI No. 139 of Sch "A" Part - XVII during 2nd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+9 upper floors 2Nos of lifts all as mentioned vide SI No. 136 of Sch "A" Part - XVII during 3rd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+9 upper floors 2Nos of lifts all as mentioned vide SI No. 139 of Sch "A" Part - XVII during 3rd year after expiry of defects liability period all as specified and directed. Note for comprehensive maintenance:- Notes: (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts & consumables like topping of gear oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personal as specified in particular specification and as recommended by Engr-in-charge and lubrication to all moving parts, topping up of oils as per lubrication chart including materials and labour for all consumable and major/minor spare parts.
Komal Buildcon Pvt. Ltd.
SOOD ASSOCIATES PVT LTD
DES RAJ AND SONS BUILDERS PVT LTD
SVS PROJECTS
MANGLA AMIT BUILDERS PVT LTD
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
SRICO PROJECTS PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid