Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
23 Oct 2026, 6:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Vice President- Materials
PE PIPELINE LAYING & PNG CONNECTIONS INCLUDING PERMISSION ACQUISITION FROM LOCAL ROU AUTHORITIES, INSTALLATION OF WELDED BASEMENT AND WELDED RISER FOR BATHINDA MILITARY STATION OF BATHINDA GA
350531
Sub tender No 350531 of Main tender no 350516
Open
Pipe / Fittings
Fixed-rate
Gandhinagar
1 document required · 1 mandatory
₹2.3 L
3 Oct 2026
3 Oct 2026
3 Oct 2026
23 Oct 2026
3 Oct 2026
SOR Quantity Base Rate Total Amount
19 MISCELLANEOUS SOR LINE ITEMS IN CONTRACTOR SCOPE WITH RATE OF SUPPLY AND INSTALLATION
19.1 103885 Supply and Installation of TRANSITION FITTTING,6"X160MM- 6" NB (Butt Weld End) X 160 MM PE 100, SDR-17 EA 1 1 2.00 33,570.00
19.2 103886 Supply and Installation of TRANSITION FITTTING,4"X125MM- 4" NB (Butt Weld End) X 125 MM PE 100, SDR-17 EA 1 1 2.00 13,813.58
19.3 103887 Supply and Installation of TRANSITION FITTTING,3"X90MM- 3" NB (Butt Weld End) X 90 MM PE 100, SDR-17 EA 1 1 2.00 10,661.10
19.4 103888 Supply and Installation of TRANSITION FITTTING,2"X63MM- 2" NB (Butt Weld End) X 63 MM PE 100, SDR-11 EA 1 1 2.00 4,410.35
19.5 103889 Supply and Installation of TRANSITION FITTTING,1"X32MM- 1" NB (But Weld End) X 32 MM PE 100, SDR-11 EA 1 1 2.00 3,198.10
19.6 103897 Supply and Installation of FRP Cover with frame 600*600mm EA 22 3 25.00 11,897.23
19.7 103898 Supply and Installation of FRP Cover with frame 1000*1000mm EA 1 1 2.00 26,096.84
RCC HUME PIPE INSTALLATION
S&I Of RCC Hume Pipe With Required All Consumables, Materials & Manpower
20.1 102992 RCC Hume Pipe-Half Round M 20 5 25.00 198.87
20.2 102993 RCC Hume Pipe-Full M 20 5 25.00 467.66
21 HIRING VEHICLE
21.1 102188 Hiring Vehicle: Provision of Economy Car like Maruti-Swift or any equivalent vehicles including Driver - 3,000 kms Slab Per Month 1 1 2.00 50,824.12
21.2 New code Hiring Vehicle: Provision of Economy Car like Maruti-Swift or any equivalent vehicles including Driver - 2,000 kms Slab Per Month 1 1 2.00 45,716.62
21.3 102189 Hiring Vehicle: Provision of Field Cars like Mahindra Bolero or any equivalent vehicles including Driver - 2,000 kms Slab Per Month 1 1 2.00 60,585.57
21.4 102190 Hiring Vehicle, Charges towards extra KM beyond specified slab for 4 Wheeler- Economy Car category, for Petrol/Diesel Vehicles only Per KM 1 1 2.00 10.65
21.5 102191 Hiring Vehicle, Charges towards extra KM beyond specified slab for 4 Wheeler- Field Car category, for Petrol/Diesel Vehicles only Per KM 1 1 2.00 12.24
21.6 104097 Hiring Vehicle, Charges towards extra KM beyond specified slab for 4 Wheeler- Economy Car category, for CNG vehicles Per KM 1 1 2.00 5.32
22 GROUND PENETRATING RADAR (GPR) SURVEY
GPR survey for identification of underground utilities like electric cable, OFC cables, communication cables, water line etc. before
commencement of trenching work with help of Ground Penetrating Radar and cable locator.
Arrangement of necessary equipments, man power, tools tackles and vehicle to perform the survey. Equipment specification and
accuracy shall match with IDS Italy. All equipment shall be fit for purpose and shall be calibrated. The same shall be reviewed and
checked TPIA/Engineer in charge before use. Frequency of same shall be as instructed by engineer in charge. Equipments shall be
capable of identifying underground utilities at the depth of up to 2.5 mtr in normal cases and/or up to the depth of proposed pipeline
whichever is higher.
GPR / cable locator search shall be carried out for stretch up to 3 meter from proposed/existing pipe centerline on both sides.
Preparation of drawing/sketch showing minimum but not limited to type and depth of utility, size/properties of utilities and
proposed/existing pipeline detail along with necessary reference points of actual site Dumpy level shall be used to define datum level
with respect to ground level in the drawing. The same shall be submitted to TPIA/engineer in charge before start of trenching work.
In addition GIS mapping by taking coordinates of utilities, using GPS. Consult and co-ordinate with concerned utility company before
commencement as per instructions from Engineer in charge."
22.1 704010 SURVEY,GROUND PENETRATING RADAR(GPR) Meter 1 1 2.00 25.00
File No: GEL-Tech. Services-2026-8-190734
Charges for compliance to Health, Safety & Environment (HSE) as detailed in Scope of Work and achievement of Zero
LTI/MTC/Major incident for tendered activities
SECTION PERMANENT RESTORATION (CIVIL WORKS) OF ROADS DAMAGED DURING PE PIPELINE LAYING AND PNG
Permanent Restoration of road as and when demanded by the permission issuing authority.
23 1. This activity is to be carried out as mentioned in SOW after prior approval from the GA Head only.
2. Retention of payments from each invoice shall be done as per tender terms.
23.1 103655 Permanent restoration , PCC on Trench with GSB M3 1 1 2.00 3,573.00
23.2 103656 Permanent restoration , Refixing of Paver block with GSB M2 1 1 2.00 1,000.00
23.3 103657 Permanent restoration , Supply and fixing of Paver block with GSB (Missing or Damaged) M2 1 1 2.00 1,650.00
23.4 103658 Permanent restoration , RCC M20 TRIMIX ROAD RESTORATION M3 1 1 2.00 4,313.00
23.5 104199 Permanent restoration , RCC M30 TRIMIX ROAD RESTORATION M3 1 1 2.00 4,713.00
23.6 103659 Permanent restoration , Asphalt Road with GSB M3 1 1 2.00 3,941.00
SECTION 2 - SOR FOR PNG CONNECTIONS AND ASSOCIATED ITEMS
DOMESTIC PNG CONNECTION INSTALLATIONS
TAPPING FROM PE SERVICE LINES AND INSTALLATION UP TO TRANSITION FITTING INCLUDING GROUND CONNECTION FOR
INDIVIDUAL CONNECTION
Supply, Construction, Laying/ Installation in all types of terrain by any method i.e. Manual Boring or Open Cut, testing &
Commissioning of 20 mm PE -100 Pipes(Free issue from GEL), PE Electrofusion fittings, warning mats, Transition fittings (PE to GI
Transition fittings), RCC Guard, Required all consumables like PTFE tape etc. which is required to complete the work at site. Proper
storing, stacking, identification, providing security, and insurance cover for the materials. Liasoning with Customers, Landowning
agencies/ statutory authorities, preparation of detailed route plan, making trial pits to determine the underground utilities/ services
etc., obtaining permission from Land owning agencies, restoration of the abandoned trial pits as required (excavation to depth for
1.0 m cover of PE Pipe or more as satisfaction to EIC) to original condition as per the directions of EIC/ site-in Charge. Trenching to
the required depth in surface, uncoiling/ stringing of Pipes, damping, jointing of the Pipe ends/ fittings/ Valves by qualified personnel,
using approved electro fusion techniques as per Specification.
25 INSTALLATION OF GI PIPES FROM TRANSITION FITTING TO APPLIANCE VALVE
Receiving, handling, loading, transportation and unloading including owner supplied Free issued materials like Domestic Meter,
Domestic Gas Pressure Regulator and Rubber Hose which is required to complete the work to Contractor's own stock-yards/ work-
Proper storing, stacking, identification, providing security, and insurance cover for the materials. Liasoning with Landowning
agencies/ statutory authorities, preparation of detailed route plan, obtaining permission restoration as required to original condition
as per EIC Instruction.
Supply and Installation of powder coated 1/2" or 1" NB GI Pipes with BSPT Connection up to customer’s Kitchen Appliances, Powder
coated ½” NB or 1” NB GI fittings, Inlet/ outlet brass adaptor for Meter/ Regulator, Clamp required for fixing of Suraksha Rubber
hose, Powder coated MS Pipe Clamp with Screw and Nuts, Nozzle for Burner conversion, Required all consumables like PTFE tape,
roul plugs etc. for leak proof and quality Installations, as per laid procedures and Specification including clamping. Color touch up to
be done on installed GI Pipes after testing of the entire Connection.
In cases of RFC connections/idle point - Hex blind plug (Contractor supplied material without additional cost to GEL) in place of
Appliance Valve need to be installed as per the instruction from EIC.
In case of builder category connection, contractor has to install hollow hex plug and also install Blind Adaptor in replacement of
Meter adaptor (Contractor supplied material without additional cost to GEL) at inlet of Domestic meter after completion of MMT as
per the instruction from EIC.
File No: GEL-Tech. Services-2026-8-190734
Pneumatic testing with nitrogen/ air and commissioning of the GI Installations, Meters, Valves, Conversion of LPG Stove / Hotplate
up to four burners Including Glass top type stove etc. as per Specification and hand over the same to Owner/ Customer to the entire
Preparation, Certification and submission of job card duly signed by customer/ daily progress reports, As-built Drawings. Restore all
surrounding Ground features to that as existing before and as directed by EIC.
Providing all tools and tackles, test ends, nitrogen, instruments, manpower and other related accessories and as per the Instructions
of the EIC. On completion of contract returning of all unused free issue materials to Owner's stores / material management system,
submission of all Documents as mentioned in the contract.
Any other activities related to completing above scope of work not mentioned/ operation/ safety/ statutory/ maintenance of the
works shall also be covered under the Scope of work and has to be completed by the Contractor within specified schedule at no extra
1. Individual Connection means PNG Connection with dedicated Ground Connection.
2. All other Tapping Connections from GI are considered under Apartment/ Flat Connections.
3. Excavation Beyond 1.5 mtr for Ground connections to be paid seprately as per SOR Sr.No 5.1 & 5.2 (GA Head approval Required
INDIVIDUAL CONNECTION
Domestic Connection: Ground Connection up to Transition Fitting for all type of strata / terrain and by any method. Additional
payment or recovery of PE length for any variation with minimum length shall be dealt as per SOR Item No.
1/2” NB GI Pipes from Transition fittings to Appliance Valve for individual Connection including additional Kitchen and Geyser
Point(s). Additional payment or recovery of GI length for any variation with minimum length shall be dealt as per SOR Item No.
Domestic Connection for First/ Second Floor Kitchen 1/2” NB GI Pipes from Ground Floor main isolation Valves to Appliance Valve
for individual Connection including additional Kitchen and Geyser Point(s) (where Ground Connection is not required and tapping
will be from existing individual Connection. GI Riser rate & GC rates are not applicable for such Connections. Additional payment or
recovery of GI length for any variation with minimum length shall be dealt as per SOR Item No.
APARTMENT/ FLAT/ ROW HOUSE CONNECTION
Tapping from GI Vertical Riser tee and Installation of GI Pipes up to Main (Meter) Isolation Valve (Lateral) and GI Pipes from Main
25.3 104158 - 104159 - 104160 isolation Valves to Appliance Valve including additional Kitchen and Geyser Point(s) for FLAT/ APARTMENT Connection. Additional EA 580 580 1160.00 3,102.49
payment or recovery of GI length for any variation with minimum length shall be dealt as per SOR Item No.
Tapping from GI Horizontal Riser tee and Installation of GI Pipes up to Main (Meter) Isolation Valve (Lateral) and GI Pipes from Main
25.4 104161 - 104162 - 104163 isolation Valves to Appliance Valve including additional Kitchen and Geyser Point(s) for ROW HOUSE Connection. Additional payment EA 1 1 2.00 3,105.97
or recovery of GI length for any variation with minimum length shall be dealt as per SOR Item No.
File No: GEL-Tech. Services-2026-8-190734
Take or Pay clause applicable length:
GUJARAT & DNH: Ground Connection 20 mm PE Installation : 3 Meter, GI Pipe S&I: Individual Houses: 6 Meter, First/ Second Floor:
9 Meter, Flat/ Apartment Tapping Conn from Riser (without GC): 5 Meter, Row Houses tapping conn from Lateral (without GC) :
MAHARASHTRA : Ground Connection 20 mm PE Installation : 3 Meter, GI Pipe S&I: Individual Houses: 6 Meter, First/ Second Floor:
9 Meter, Flat/ Apartment Tapping Conn from Riser (without GC): 3 Meter, Row Houses tapping conn from Lateral (without GC) :
AMRITSAR ,H&G GA, BHATINDA, SFM & FFM GA : : Ground Connection 20 mm PE Installation : 5 Meter, GI Pipe S&I: In Individual
Houses: 12 Meter, First/ Second Floor: 9 Meter, Flat/ Apartment Tapping Conn from Riser (without GC): 5 Meter, Row Houses tapping
conn from Lateral (without GC) : 5 Meter
JALORE-SIROHI GA, BANSWARA AND DUNGARPUR GA, UDI AND JABUA-RATLAM GA: Ground Connection 20 mm PE Installation :
3 Meter, GI Pipe S&I: Individual Houses: 10 Meter, First/ Second Floor: 12 Meter, Flat/ Apartment Tapping Conn from Riser (without
GC): 5 Meter, Row Houses tapping conn from Lateral (without GC) : 5 Meter
1. Minimum GI S&I length : Includes all point(s) for kitchen & Geyser in Domestic conn. Installation of GI length need to be
considered from TF to appliance valve
2. Minimum PE Service (Installation) : length of 20mm PE laying (PE Supply in GEL Scope) to be considered from Tap-off point to TF
(TF length shall be excluded)
Average GI = Total GI length for all point(s) in kitchen & Geyser of Individual conn (All type) / Total nos. of Individual conn (All type)
Average PE = Total Length of 20 mm Pipe (Open cut + Manual boring) / Total Nos. of Ground connections
The differential amount shall be paid / recovered as per the Formula & Rates mentioned below:
1. For individual Connections (all type) =((Sum of GI pipe length of all point(s) in kitchen and Geyser of total installed connections ÷
NOTE total number of installed conn)-(Given minimum length of GI pipe for particular GA as per above)) x ( As per quoted in applicable
SOR (extra GI rate) x total number of installed conn).
2. For Ground Connection (Laying cost for 20mm PE) = ((Sum of total laying length of connections / No. of total individual
connection i.e. only Ground Connection) - (Given minimum length of Ground connection for particular GA as per above)) x (As per
quoted in applicable SOR (extra 20mm PE pipe rate) x total number of installed individual connections i.e. Ground Connection
For calculation purpose SAP data shall be considered as final. GEL will make extra payment in case, if the total GI S&I / PE Pipe (only
installation) length installed by a Contractor is more than specified length above or will recover the payment from the Contractor if
the total GI/ PE Pipe length installed by a Contractor in less than specified length above on Monthly/ RA Bill basis.
PNG-DOMESTIC/COMMERCIAL/INDUSTRIAL CONNECTIONS - ASSOCIATED SOR LINE ITEMS
GROUND CONNECTION AND RISER INSTALLATION WITH A PROVISION OF TEE AT EACH FLOOR WITH HEX PLUG IF ANY FOR
APARTMENTS/ FLATS
Permission acquisition from various authorities for ground connection (wherever applicable) with Supply, Construction, Laying/
Installation in all types of terrain by any method i.e. Manual Boring or Open Cut, testing & Commissioning of 32 mm / 20 mm PE
Pipes(Free Issue by GEL), PE Electrofusion fittings, warning mats, Transition fittings (PE to GI Transition fittings), RCC Guard, Required
all consumables like PTFE tape etc. which is required to complete the work at site. Proper storing, stacking, identification, providing
security, and insurance cover for the materials. Liasoning with Customers, Landowning agencies/ statutory authorities, preparation
of detailed route plan, making trial pits to determine the underground utilities/ services etc., obtaining permission from Land owning
agencies, restoration of the abandoned trial pits as required (excavation to depth for 1.0 m cover of PE Pipe or more as satisfaction
to EIC) to original condition as per the directions of EIC/ site-in Charge. Trenching to the required depth in surface, uncoiling/ stringing
File No: GEL-Tech. Services-2026-8-190734
of Pipes, damping, jointing of the Pipe ends/ fittings/ Valves by qualified personnel, using approved electro fusion techniques as per
Supply and Installation of powder coated 1/2"/ 1" GI Pipes including GI fittings, Required all consumables like PTFE tape, roul plugs
etc. for leak proof Riser Installations, as per laid procedures and Specification including clamping. Color touch up to be done on
installed GI Pipes after testing of the entire Riser including Ground Connection. Also includes Supply and Installation of Hollow hex
plug in case of no Appliance Valve installed and Installation of owner supplied Rubber Hose for main Point
For Horizontal Header, Row house of 5 mtr is considered with 1.5 mtr GI piece for GC.
In G+3 Row house- 16.5 mtr of 1/2'' & In G+6 Row house- 31.5 mtr of 1'' is considered
Additional payment of GI length for any excess GI installation over & above minimum length mentioned shall be dealt as per SOR
26.1 GI RISER / GI HEADER INSTALLATION (THREADED)
26.1.1 103682-103683-103684 Installation of 1/2" Riser up to G+3 including Ground Connection. (Excluding Horizontal Approach) EA 250 250 500.00 5,070.98
26.1.2 103685-103686-103687 Installation of 1/2" Riser up to G+3 excluding Ground Connection: For Basement welded Riser (Excluding Horizontal Approach) EA 1 1 2.00 3,439.14
26.1.3 103688-103689-103690 Installation of 1/2" Riser beyond G+3 Floor for each Floor extension. (Excluding Horizontal Approach) EA 1 1 2.00 1,105.19
26.1.4 103691-103692-103693 Installation of 1/2" Header (Horizontal) up to 3 Row Houses including Ground Connection. EA 1 1 2.00 5,945.57
26.1.5 103694-103695-103696 Installation of 1/2" Header (Horizontal) beyond 3 Row Houses for each Row House extension. EA 1 1 2.00 1,547.89
26.1.6 103697-103698-103699 Installation of 1" Riser up to G+8 including Ground Connection (Excluding Horizontal Approach) EA 1 1 2.00 13,867.35
26.1.7 103700-103701-103702 Installation of 1" Riser up to G+8 excluding Ground Connection: For Basement welded Riser (Excluding Horizontal Approach) EA 1 1 2.00 11,925.63
26.1.8 103703-103704-103705 Installation of 1”Riser beyond G+8 Floor for each Floor extension. (Excluding Horizontal Approach) EA 1 1 2.00 1,815.37
26.1.9 103706-103707-103708 Installation of 1" Header (Horizontal) up to 6 Row Houses including Ground Connection. EA 1 1 2.00 15,367.87
26.1.10 103709-103710-103711 Installation of 1" Header (Horizontal) beyond 6 Row Houses for each Row House extension. EA 1 1 2.00 2,567.10
26.2 INSTALLATION OF HORIZONTAL GI THREADED APPROACH FOR RISER CONNECTIVITY
26.2.1 103775-103776-103777 1/2" NB GI Pipe Horizontal Approach Installation as per Instruction of Engineer In Charge M 1 1 2.00 290.56
26.2.2 103778-103779-103780 1" NB GI Horizontal Approach Installation as per Instruction of Engineer In Charge. M 1 1 2.00 487.15
26.3 PERMISSION & INSTALLATION OF COMMERCIAL / WALL MOUNTED INDUSTRIAL CONNECTION
26.3.1 104130 Logistic, handling, transportation and additional operational expenses for wall mounted commercial and Industrial connection. EA 1 1 2.00 1,581.91
PE laying 20 MM (GEL supplied PE Pipe) Open cut/Manual Boring(HDD excluded) with supply, laying, testing & commissioning - for
26.3.2 104146 - 104147 commercial/industrial conn M 1 1 2.00 349.36
(Breaking of RCC/PCC/Rock etc. rates are applicable as per relevant SOR)
PE laying 32 MM (GEL supplied PE Pipe) Open cut/Manual Boring(HDD excluded) with supply, laying, testing & commissioning - for
26.3.3 104148 - 104149 commercial/industrial conn M 1 1 2.00 367.75
(Breaking of RCC/PCC/Rock etc. rates are applicable as per relevant SOR)
20mm Ground connection for wall mounted Commercial and Industrial connections till RCC guard (PE laying & Breaking of
RCC/PCC/Rock etc. rates are applicable as per relevant SOR)
32mm Ground connection for wall mounted Commercial and Industrial connections till RCC guard (PE laying & Breaking of
RCC/PCC/Rock etc. rates are applicable as per relevant SOR)
26.3.6 103241 - 103242 Supply and Installation of 1/2" GI Pipe for Commercial/ Wall Mounted Industrial Connection M 200 500 700.00 445.70
File No: GEL-Tech. Services-2026-8-190734
26.3.7 103243 - 103244 Supply and Installation of 1" GI Pipe for Commercial/ Wall Mounted Industrial Connection M 700 50 750.00 618.42
26.3.8 104004 Supply and Installation of Meter Adaptor (Inlet & Outlet Both) for Meter Size G-1.6 EA 35 5 40.00 581.53
26.3.9 104005 Supply and Installation of Meter Adaptor (Inlet & Outlet Both) for Meter Size G-2.5 EA 1 1 2.00 581.53
26.3.10 104150 Supply and Installation of Meter Adaptor (Inlet & Outlet Both) for Meter Size G-4 EA 1 1 2.00 581.53
26.3.11 104006 Supply and Installation of Meter Adaptor (Inlet & Outlet Both) for Meter Size G-6 EA 36 4 40.00 1,507.50
26.3.12 104007 Supply and Installation of Meter Adaptor (Inlet & Outlet Both) for Meter Size G-10 EA 90 10 100.00 2,515.50
26.3.13 104008 Supply and Installation of Meter Adaptor (Inlet & Outlet Both) for Meter Size G-16 EA 16 4 20.00 2,515.50
26.3.14 104009 Supply and Installation of Meter Adaptor(Inlet & Outlet Both) for Meter Size G-25 EA 1 1 2.00 3,405.00
RUNNING METER RATE OF PE PIPE (ONLY INSTALLATION CHARGE)/GI PIPE (SUPPLY & INSTALLATION) FOR
INDIVIDUAL/APARTMENT/ROW HOUSE CONNECTIONS
27.1 103283 GI Supply & Installations over & above the minimum length as mentioned above M 1 1 2.00 256.85
27.2 104164 PE 20 mm Installations over & above the minimum length as mentioned above M 1 1 2.00 235.83
28 REGISTRATION FOR DOMESTIC CONNECTIONS
28.1 104165 Registration of Domestic customers - SOR to be utilized upon approval of GEL EIC EA 1 1 2.00 287.00
29 ISLAND KITCHEN INSTALLATION
Supply and Installation of SS tube for Island Kitchen up to 3 running meter including installation of SS fittings, UPVC conduit pipe and
consumables as per technical scope of work in tender document
29.2 103882 Supply and Installation of SS tube for Island Kitchen over and above 3 running meter M 1 1 2.00 990.00
ADDITIONAL POINT
30 101325 Labor charges for Installation of Appliance valve & Owner supplied Rubber Hose including supply of rubber hose clamp for additional EA 1 1 2.00 87.36
CONVERSION OF STOVE
Conversion of Stove Including glass top type up to 4 burner for additional kitchen/force NG cases.
BUILDER CASES - RISER GROUND CONNECTION
This SOR is for Ground Connection of GI Riser / Header. It is applicable only when riser installation is to be delayed due to building
construction / builder's requirement is to carryout ground connection. This activity is to be carried out with prior approval of GEL
EIC. Supply of PE pipe is in GEL Scope.
32.1 103597 Ground Connection of 1/2" riser up to isolation valve with hex plug EA 1 1 2.00 2,909.67
32.2 103598 Ground Connection of 1" riser up to isolation valve with hex plug EA 1 1 2.00 3,190.57
WELDED VERTICAL GI RISER INSTALLATION IN HIGH RISE MULTI-STOREY BUILDING FOR PNG CONNECTIONS
Activity is to be carried out as per the Scope of work in Tender Documents which includes but not limited to,
* Mobilization of manpower, machines, tools & tackles and other resources.
* In case of any GEL supplied materials, issue from store/GEL material management system
* All applicable Transportation, loading & unloading and use of equipment like crane, hydra etc. in contractor scope at his cost
* Fabrication, Installation, Testing and Commissioning of Riser with BSPT connection with fillet welding as per GEL Procedure
* Contractor supplied materials as mentioned in Scope of work shall be procured from GEL approved vendors only.
(1” GI Pipe - 17 to 25 No.s of Domestic Connection one on each floor; 1½” GI Pipe - 26 to 50 Nos. of Domestic Connection one on
each floor; 2'' GI Pipe- Over 50 Nos of Domestic Connection)
33.1 104166 - 104167 Supply and installation of 1'' Welded Riser with fittings Meter 1 1 2.00 949.95
33.2 104168 - 104169 Supply and installation of 1.5'' Welded Riser with fittings Meter 1 1 2.00 1,270.99
33.3 104170 - 104171 Supply and installation of 2'' Welded Riser with fittings Meter 1 1 2.00 1,566.21
33.4 103900 Supply and installation of MS CLAMP of 1" EA 1 1 2.00 69.48
33.5 103901 Supply and installation of MS CLAMP of 1.5" EA 1 1 2.00 92.54
File No: GEL-Tech. Services-2026-8-190734
33.6 103902 Supply and installation of MS CLAMP of 2" EA 1 1 2.00 106.93
33.7 103890 Supply and installation of ANACONDA EA 1 1 2.00 398.00
SECTION WELDED COMMON APPROACH IN BASEMENT AREA OF APARTMENT FOR DOMESTIC CONNECTIONS AND
2D WELLDED INSTALLATION FOR COMMERCIAL & INDUSTRIAL CONNECTIONS.
Activity is to be carried out as per the Scope of work in Tender Documents which includes but not limited to,
* Mobilization of manpower, machines, tools & tackles and other resources.
* In case of any GEL supplied materials, issue from store/GEL material management system
34 * All applicable transportation, loading & unloading and use of equipment like crane, hydra etc. are in contractor scope at his cost
* Fabrication, Installation, Testing and commissioning as per GEL procedure.
* The rate excluding welding of joints, fabrication of support, S&I of Pipe & Fittings. Respective SOR item to be claimed separately.
* Contractor supplied materials as mentioned in Scope of work shall be procured from GEL approved vendors only.
34.2 104174 - New code S&I,GI PIPE,'C' CLASS,HEAVY,2" M 1 1 2.00 713.56
34.5 102115 S&I,BALL VALVE,THREADED,150#,1" (ASTM A105) EA 1 1 2.00 1,218.71
34.6 102116 S&I,BALL VALVE,SOCKET WELD,150#,1" EA 1 1 2.00 3,003.71
34.7 102117 S&I,BALL VALVE,FLANGE END,150#,1" EA 1 1 2.00 3,447.73
34.8 102119 S&I,BALL VALVE,FLANGE END,150#,2"- FOR WELDED RISER AND APPROACH EA 1 1 2.00 6,808.25
34.9 102120 S&I,BALL VALVE,FLANGE END,150#,3" EA 1 1 2.00 15,201.43
34.10 102121 S&I,REDUCER,BUTT WELD,3"X2" EA 1 1 2.00 601.39
34.11 102123 S&I,REDUCER,BUTT WELD,2"X1" EA 1 1 2.00 306.86
34.12 102646 S&I,REDUCER,BUTT WELD,3"X1" EA 1 1 2.00 671.21
34.13 102124 S&I,EQUAL TEE,BUTT WELD,2" EA 1 1 2.00 648.06
34.14 102126 S&I,EQUAL TEE,SOCKET WELD,1" EA 1 1 2.00 277.06
34.15 102128 S&I,REDUCING TEE,BUTT WELD,2"X1" EA 1 1 2.00 648.06
34.16 102133 S&I,ELBOW,90°,SOCKET WELD,1" EA 1 1 2.00 336.06
34.19 102139 S&I,HEX PLUG,HOLLOW,1/2" EA 1 1 2.00 90.14
34.20 102136 S&I,ELBOW,45°,SOCKET WELD,1" EA 1 1 2.00 336.06
34.22 102137 S&I,END CAP,BUTT WELD,2" EA 1 1 2.00 359.06
34.23 102138 S&I,END CAP,SOCKET WELD,1" EA 1 1 2.00 194.06
34.24 102140 S&I,COUPLING,BUTT WELD,2" EA 1 1 2.00 422.89
34.25 102142 S&I,COUPLING,SOCKET WELD,1" EA 1 1 2.00 188.88
34.26 102146 S&I,RED COUPLING,1'(SW)*1/2" (THREADED) EA 1 1 2.00 196.42
34.28 102148 S&I,NIPPLE,SWXTHREAD,1",6"LONG EA 1 1 2.00 249.66
34.29 102650 S&I,NIPPLE,SWXTHREAD,1/2",3"LONG EA 1 1 2.00 109.46
File No: GEL-Tech. Services-2026-8-190734
34.34 908258 S&I,PLASTIC PADDING 1" EA 1 1 2.00 33.25
34.35 908259 S&I,PLASTIC PADDING,2" EA 1 1 2.00 58.45
34.36 908260 S&I,PLASTIC PADDING,3" EA 1 1 2.00 82.60
34.43 901748 RCC/BRICK HOLE WITH S&I ANTICORR WRAP (CORE CUTTING) - THIS SOR IS FOR WELDED INSTALLATIONS ONLY EA 1 1 2.00 695.36
34.44 101944 S&I,PVC SLEEVE,63 MM DIA,PIPE 2" Meter 1 1 2.00 135.85
34.45 102015 S&I,PVC SLEEVE,40 MM DIA,PIPE 1" Meter 1 1 2.00 120.10
34.46 102658 S&I,NUT & STUD WITH WASHER 1/2"X3" EA 1 1 2.00 63.00
34.47 102659 S&I,NUT & STUD WITH WASHER 5/8"X3.5 EA 1 1 2.00 78.75
34.48 102662 WELDJOINTS,NDT,IND CONN/BASEMENT INCH DIA 1 1 2.00 376.06
34.49 102153 STRUCTURAL WORK,PIPE SUPPORT-FOR WELDED RISER AND APPROACH KG 1 1 2.00 118.54
34.50 102118 S&I,BALL VALVE,FLANGE END,150#,1*1/2" EA 1 1 2.00 4,746.71
34.51 102122 S&I,REDUCER,BUTT WELD,2"X1*1/2" EA 1 1 2.00 377.21
34.52 102125 S&I,EQUAL TEE,SOCKET WELD,1*1/2" EA 1 1 2.00 517.88
34.53 102127 S&I,REDUCING TEE,SOCKET WELD,2"X1/2" EA 1 1 2.00 1,335.91
34.57 102141 S&I,COUPLING,SOCKET WELD,1*1/2" EA 1 1 2.00 271.23
103819 S&I,IPRS,CPRS,MRS,OUTLET,UPTO 3” EA 1 1 2.00 7,753.00
INSTALLATION OF MRS,IPRS, CPRS AT CUSTOMER PREMISES.
* Mobilization of manpower, machines, tools & tackles and other resources.
34.58 * Material receipt from store/material management system, transportation, loading and unloading including cost of equipment like
crane, hydra etc.
* Inlet and outlet hook up with existing Network / Installation, Testing and commissioning.
* The rate excludes welding of joints, fabrication of support, S&I of Pipe & Fittings. Respective SOR item to be claimed separately.
103818 REPAIRING,MODIFICATION,WELDED INSTALLATION EA 1 1 2.00 5,161.00
REPAIRING AND MODIFICATION OF WELDED INSTALLATION.
* Rate includes on call basis emergency work for particular Job
* Mobilization of manpower, machines, tools & tackles and other resources to complete the Repairing & Modification job up to
34.59 Nos of joints
* Shutdown charges for mentioned job of welded installation.
* Decommissioning of charged line, purging, cutting, welding, testing and re-commissioning of isolated section of piping.
* The rate excludes welding of joints, fabrication of support, Supply of N2, S&I of Pipe & Fittings. Respective SOR item to be
claimed separately.
103817 TESTING,PNEUMATIC,PURGING,UPTO,3"LINE M 1 1 2.00 93.14
PNEUMATIC TESTING AND NITROGEN PURGING FOR MODIFICATION CASES
* Purging and Pneumatic testing of welded pipeline for Alteration / Modification work of existing welded installation of up to 3"
diameter pipeline.
File No: GEL-Tech. Services-2026-8-190734
* The scope includes supply of required nitrogen cylinder.
Note : This SOR is specifically for Repairing & Modification cases only.
1. The SOR Items would be operatable as per job requirement and quantities may vary on ± sides.
2. The scope as mentioned in SOR is of indicative nature only and shall include all activities as detailed in the
relevant Tender Document.
Important 3. The SOR shall be read along with the relevant Clauses provided in the Tender Document.
Note 4. Bidder shall note that the quantities mentioned against each activity in Schedule of Rates are tentative
only. These quantities subject to change based on actual requirement. Quantities in SOR are considered based
on targets set by PNGRB. However, actual no. of execution may vary based on various factors during the
course of the contract period.
Total Value in Rs
Total Value in Rs Cr
Bungalow 1st/2nd Flr
DPNG Connections in
Total connection
PE Laying 90 mm
Indicative Length in 125 mm
Total PE laying
File No: GEL-Tech. Services-2026-8-190734
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Schedule of Rate (SOR) Bhatinda Military.pdf.pdf
Targets Bathinda.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .