Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAdmitted-Finance | ₹36.9 L | L1 | Admitted-Finance |
| 2 | L2₹38.7 L+₹1.7 L (4.71%)Admitted-Finance | ₹38.7 L+₹1.7 L (4.71%) | L2 | Admitted-Finance |
| 3 | L3₹39.6 L+₹2.6 L (7.07%)Admitted-Finance | ₹39.6 L+₹2.6 L (7.07%) | L3 | Admitted-Finance |
| 4 | L4₹40.0 L+₹3.0 L (8.22%)Admitted-Finance | ₹40.0 L+₹3.0 L (8.22%) | L4 | Admitted-Finance |
| 5 | L5₹42.0 L+₹5.0 L (13.6%)Admitted-Finance GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | ₹42.0 L+₹5.0 L (13.6%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S tiwari enterprises L3 | M/s Ray construction L5 | M/S Akash Enterprises L2 | M/S Bhushan Kumar Jain L4 | ranjit singh L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down defective split type ACs/Window type AC Units, shifting to work shop, taking out the defective compressor of capacity 1.5 Ton capacity from unit, replacing the compressor with new compressor, cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas, reinstalling in its original position, connecting up all. electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation.
Make : Carrier / LG / Samsung / Sriram / Voltas / Kirloskar / Techamsa / Blue Star | 12 | Job | 12,300 ₹1,47,600 | 12,470 ₹1,49,640 | 12,250 ₹1,47,000 | 12,500 ₹1,50,000 | 11,500 ₹1,38,000 Lowest |
| 2.00 | Taking down defective split type ACs/Window type AC Units, shifting to work shop, taking out the defective compressor of capacity 2.0 Ton capacity from unit, replacing the compressor with new compressor, cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas, reinstalling in its original position, connecting up all. electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation.
Make : Carrier / LG / Samsung / Sriram / Voltas / Kirloskar / Techamsa / Blue Star | 10 | Job | 13,100 ₹1,31,000 | 13,070 ₹1,30,700 | 13,000 ₹1,30,000 | 13,200 ₹1,32,000 | 12,200 ₹1,22,000 Lowest |
| 3.00 | Material & Labour for replacement of rusted body portions of split type AC/Window type AC unit of 1.5/2.0 Ton capacity with same gauge / size materials like MS sheet, angle iron similar to the existing one by removing existing, foam pad and components and scraping out old paint on complete body, cleaning surface thoroughly, Appling two coats synthetic enamel paint of approved shade over a coat of red oxide primer, fixing of new foam pad of not less than 3mm thick, refixing of all components, testing and installation in original position, connecting up all electrical connections, testing and commissioning all as specified and directed. | 4 | Job | 3,550 ₹14,200 | 3,675 ₹14,700 | 3,500 ₹14,000 | 3,600 ₹14,400 | 3,000 ₹12,000 Lowest |
| 4.00 | S&F in repair for fan blade set for 1.5/2.0 Ton capacity of any type of ACs, suitable for existing makes and rotation in the casing testing including taking out the defective condenser fan blade complete all as specified and as directed | 10 | Job | 3,520 ₹35,200 | 3,675 ₹36,750 | 3,500 ₹35,000 | 3,600 ₹36,000 | 2,500 ₹25,000 Lowest |
| 5.00 | M&L for Evoporator fan blower motor of suitable capacity duly ISI marked, double inlet, double width centrifugal type suitable for 1.5/2.0 Ton capacity split type AC including taking down the unserviceable damaged blower complete all as specified and directed. | 10 | Each | 3,050 ₹30,500 | 3,160 ₹31,600 | 3,000 ₹30,000 | 3,200 ₹32,000 | 2,500 ₹25,000 Lowest |
| 6.00 | Supply and fix in repair swing motor for ACs suitable for existing size and capacity of 1.5/2 Ton complete all as specified and directed. | 15 | Each | 780 ₹11,700 | 1,086 ₹16,290 | 770 ₹11,550 | 800 ₹12,000 | 700 ₹10,500 Lowest |
| 7.00 | Scrapping the existing painted surface of split type A/C and window type AC, cleaning the surface thoroughly and apply two coats of approved synthetic enamel paint over a coat of red oxide primer for any capacity of ACs complete all as specified and as directed. | 6 | Job | 1,030 ₹6,180 | 986 ₹5,916 Lowest | 1,020 ₹6,120 | 1,050 ₹6,300 | 1,000 ₹6,000 |
| 8.00 | M&L for Single pole contactor for 1.5/2.0 ton capacity of split type ACs complete all as specified and as directed. | 5 | Each | 930 ₹4,650 | 986 ₹4,930 | 925 ₹4,625 | 950 ₹4,750 | 600 ₹3,000 Lowest |
| 9.00 | M&L for repair and replacement of thermal insulation for 1.5/2.0 Ton split type ACs complete all as specified and as directed | 60 | RM | 15 ₹900 | 325 ₹19,500 | 10 ₹600 Lowest | 320 ₹19,200 | 200 ₹12,000 |
| 10.00 | M&L for Themal over load relay for 1.5/2.0 Ton capacity of any type of ACs including taking down unserviceable thermal over load relay complete all as specified and directed. | 16 | Each | 610 ₹9,760 | 645 ₹10,320 | 605 ₹9,680 | 625 ₹10,000 | 500 ₹8,000 Lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
17 Aug 2026, 6:00 pmClosed
GE RAMGARH CANTT
RAMGARH CANTT
REP MAINT OF SUB MAIN WIRING DBS TPN SPN DBS BLDG SECURITY LIGHT CONNECTED ITEMS, REP REPLACEMENT OF INTERNAL WIRING , MCBS DBS INCL SUB MAIN WIRING OTHER CONNECTED ACCESSORIES MISC E/M WK AND REPAIR MAINT OF DEEP FREEZER, ETC AT GE RAMGARH
2026_MES_779691_1
8300/3436/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE RAMGARH CANTT
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE RAMGARH CANTT
₹76,000
Yes
28 Aug 2026
20 Jul 2026
24 Aug 2026
20 Jul 2026
17 Aug 2026
3 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down defective split type ACs/Window type AC Units, shifting to work shop, taking out the defective compressor of capacity 1.5 Ton capacity from unit, replacing the compressor with new compressor, cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas, reinstalling in its original position, connecting up all. electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation.
Make : Carrier / LG / Samsung / Sriram / Voltas / Kirloskar / Techamsa / Blue Star | 12 | Job | 100 | ₹1,200 |
| 2 | Taking down defective split type ACs/Window type AC Units, shifting to work shop, taking out the defective compressor of capacity 2.0 Ton capacity from unit, replacing the compressor with new compressor, cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas, reinstalling in its original position, connecting up all. electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation.
Make : Carrier / LG / Samsung / Sriram / Voltas / Kirloskar / Techamsa / Blue Star | 10 | Job | 100 | ₹1,000 |
| 3 | Material & Labour for replacement of rusted body portions of split type AC/Window type AC unit of 1.5/2.0 Ton capacity with same gauge / size materials like MS sheet, angle iron similar to the existing one by removing existing, foam pad and components and scraping out old paint on complete body, cleaning surface thoroughly, Appling two coats synthetic enamel paint of approved shade over a coat of red oxide primer, fixing of new foam pad of not less than 3mm thick, refixing of all components, testing and installation in original position, connecting up all electrical connections, testing and commissioning all as specified and directed. | 4 | Job | 10 | ₹40 |
| 4 | S&F in repair for fan blade set for 1.5/2.0 Ton capacity of any type of ACs, suitable for existing makes and rotation in the casing testing including taking out the defective condenser fan blade complete all as specified and as directed | 10 | Job | 10 | ₹100 |
| 5 | M&L for Evoporator fan blower motor of suitable capacity duly ISI marked, double inlet, double width centrifugal type suitable for 1.5/2.0 Ton capacity split type AC including taking down the unserviceable damaged blower complete all as specified and directed. | 10 | Each | 10 | ₹100 |
| 6 | Supply and fix in repair swing motor for ACs suitable for existing size and capacity of 1.5/2 Ton complete all as specified and directed. | 15 | Each | 10 | ₹150 |
| 7 | Scrapping the existing painted surface of split type A/C and window type AC, cleaning the surface thoroughly and apply two coats of approved synthetic enamel paint over a coat of red oxide primer for any capacity of ACs complete all as specified and as directed. | 6 | Job | - | - |
| 8 | M&L for Single pole contactor for 1.5/2.0 ton capacity of split type ACs complete all as specified and as directed. | 5 | Each | - | - |
| 9 | M&L for repair and replacement of thermal insulation for 1.5/2.0 Ton split type ACs complete all as specified and as directed | 60 | RM | 100 | ₹6,000 |
| 10 | M&L for Themal over load relay for 1.5/2.0 Ton capacity of any type of ACs including taking down unserviceable thermal over load relay complete all as specified and directed. | 16 | Each | 100 | ₹1,600 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
TENDER3436.pdf
Tender Documents • 1.99 MB
BOQ_873311.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .