Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹30 L
EMD Value
₹30,000
Closing Date
1 Dec 2026, 6:00 pm6d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EXECUTIVE ENGINEER (O&M)DGVCL,DIVISION, DHARAMPUR
Tender for the work of laying, commissioning and testing of 11KV UG XLPE cable for link line work under SI & other Scheme for the New 11KV Bhensdara JGY Feeder (from S S to Chinchozar Road) of Dharampur-1 Sub Division under Dharampur Division.
367842
DHR/AB/TECH/26-27/105 Dtd: 20/11/2026
Open
Electrical Works
Works
Valsad
18 documents required · 18 mandatory
₹1,180
DGVCL
₹30,000
20 Nov 2026
20 Nov 2026
20 Nov 2026
1 Dec 2026
20 Nov 2026
180 days
LABOUR RATE FOR UNDERGROUND CABLE WORK FOR FY 2024-25 (WITHOUT GST)
Item Code Description Unit
Labour charge for excavation of cable trench of 400mm width x 1200mm depth, in any type of soil for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 600mm width x 1200mm depth, in any type of soil for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 400mm width x 1500mm depth, in any type of soil for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be considered i.e. half trench length is to be considered)
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to 240 mm2 & preparation of sand layer 100mm thick, in the cable trench &
covering the cable with 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC half round muffs and providing and fixing of 4inch width
4 9925000004 yellow colour polyethylene tape with printing "CAUTION ELECTRIC CABLE BELOW" at 0.75 m depth from groundsurface after laying cable in Meter
trench. This will provide indication that electric cable is passing underground so as to protect cable from mechnical injuries, refilling the same,
as per Instruction of Engineer in Charge (EIC).
Labour charge for horizontal drilling using Auger machine without damage to surface road at max 2.0 mtrs depth & putting of 6.11 kg/cm2
class-4,Green color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS 49841987(3rd revision) and BIS certification and laying of
5 9925000005 11KV/22KV XLPE cable of size up to 240 mm2 in HDPE pipe, as per Site Condition (excluding cost of pipe). The detail map obtained from HDD Meter
machine and excell sheet(hard and soft copy) indicating the respective depth and distance from adjacent landmark for each segment for HDD is
must required to be submitted. HDD to be carried out at depth 1.5 mtrs to 2.0 mtrs as per site conditions and as per instruction of EIC.
Labour charge for horizontal drilling manually without damage to surface road at max 2.0 mtrs depth & putting of 6.11 kg/cm2 , class-4,Green
color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS 4984-1987(3rd revision) and BIS certification and laying of 11KV/22KV XLPE
6 9925000006 cable of size up to 240 mm2 size, as per Site Condition (excluding cost of pipe). The detail map and excell sheet(hard and soft copy) indicating Meter
the respective depth and distance from adjacent landmark for each segment of cable to be submitted. Drilling to be carried out at depth
Minimum 1.2 mtrs to 2.0 mtrs as per site conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5 mm thickness H.D.P.E. pipe confirms to IS 4984 and BIS certification for laying of
underground 11KV / 22KV XLPE cable up to 240 mm2 size.
Labour work for RCC concreting on disputed location and repairing of damage portion of road crossing for the work carried out for roads
crossing as well as concreting & muffing of ploes including all materials (1:2:4)
Providing & fixing concrete stone route marker of 300 mm width x 150 mm thick x 650 mm height embedded in earth at least 300 mm below &
350 mm above ground level respectively at distance approx 50 meters along the length of cable. The RCC concreting (1:2:4)(all necessary
maeterials will be in bidder's scope) of route marker is to be carried out 300 mm width x 150 mm thick x 300 mm below ground level as per
instruction of EIC. The route marker should be with name of company with approved yellow colour-DGVCL. The distance from marker to cable
and cable depth with feeder name etc., marked with arrow sign is to be painted on it.The route marker is to be fixed at location near to any
fixed permanent location (not necessary to fix exact on top of cable) as per instruction of EIC.
Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ pole with cable connection arrangement along with fitting of necessary
fabrication for 11KV cable including excavation of pit & refilling of earth as per instruction of EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr RSJ pole with cable connection arrangement along with fitting ofnecessary fabrication for
11KV/22 KV cable including excavation of pit & refilling of earth as per instruction of EIC.(Exclusive of concreting & muffing of poles)
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole with cable connection arrangement along with fitting of necessary fabrication
for 11KV cable including excavation of pit & refilling of earth as per instruction of EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 8.0 Mtr PSC pole with cable connection arrangement along with fitting ofnecessary fabrication for
11KV/22 KV cable including excavation of pit & refilling of earth as per instruction of EIC. (Exclusive of concreting & muffing of poles)
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to 240 mm 2 on DP Structure with fixing of 02 Nos polymer cleats on top and
middle part.Polymer cleats, nut bolts etc. fixing material to be provided by contractor.
Providing & fixing of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS 4984 and BIS certification
on the erected DP structure for the mechanical protection of cable by inserting the cable inside HDPE pipe. The HDPE pipe shall be erected in
such a way that 300mm shall be below the ground level and the rest 2700 mm shall be supported on the DP Structure with 01 No Polymer
cleat.All materials including polymer cleat and Nut bolt to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B GI pipe with pit to be filled with salt & coke and construction of chamber as
16 9925000016 per DGVCL Drg. No. dg /100 for DP and cable. The earthing pit should be joined with cable by G.I. strip of size 1” width & 2 mm thick. All No.
material GI pipe, Coke, Salt etc will be supplied by bidder.
17 9925000017 Supply & fixing of heat shrink type end terminations (outdoor) for upto 11kV 3C x 185 mm2 size XLPE cable as per DGVCL technical specification No.
Supply & fixing of heat & shrinkable end terminations (outdoor) for upto 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL technical
19 9925000019 Supply & fixing of heat shrink type end terminations (indoor) for upto 11kV 3C x 185 mm 2 size XLPE cable as per DGVCL technical specification) No.
Supply & fixing of heat & shrinkable end terminations (indoor) for upto 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL technical
21 9925000021 Supply & fixing of heat shrinkable straight through joint for upto 11kV 3C x 185 mm size XLPE cableas per DGVCL technical specification. No.
22 9925000022 Supply & fixing of heat shrinkable straight through joint type for upto 22kV 3C x 185 mm 2 size XLPE cable as per DGVCL technical specification No.
Labour charge for excavation of 2100mm long x 1200mm wide x 1200 mm deep joint pits for installation of 11kV / 22kV Straight through
23 9925000023 joints as per instruction of engineer-in-charge & covering the cable with 150 mm dia (Outer), thickness 25 mm, 1.0 meter long RCC half round No.
muffs & refilling same as per instruction of EIC .
Providing and fixing of insulating bus bar, made from 11KV/22KV XLPE cable after removal of semi conducting layer and applying of PVC heat
shrinkable antitracking core insulating tubing (1.1KV), on both end terminal using Aluminium long barrel heavy duty up to 240 sq mm lugs,
24 9925000024 Aluminium bus connector. Taping with PG- clamp for bus conductor as per drawing and as per instruction of EIC. The Alluminium lugs and PG No.
clamp shall be covered with 11KV/22KV HT insulating tapes.(11KV/22KV XLPE cable will be in scope of DGVCL while all other materials will be
in bidder's scope)
Testing of cable at various points and commissioning the feeder as per instruction of engineer-in-charge.Test result shall be submitted by
contractor with bill.
Preparation and submission of 6 (six) copies, of complete layout drawings with GIS mapping as per actual cable routing showing road crossing,
HDPE pipe sleeving, jointing locations, markers etc.
Providing and fixing of Sign Board at junction point Made out of 2 mm aluminium sheet size 750x300 mm (2.5 x 1ft) rectangle, as per design,
pre treated with phosphate process and acid etching coated with one coat of epoxy primer and two coats of best quality paints, refloctrorised
with Hi-Intensity retro – reflective sheeting as per the latest and frame fabricated from suitable size iron angle. The Sign Board is to be fixed on
the base prepared from channel and bracing angles which is grouted by means of cement concreting of 1:2:4 for size of 300 mm dia x 800 mm
height (500 mm to be grouted in ground). The details to be displayed on sign board will be given by In-charge Engineer. (a) Hi intensity Micro
prismatic Grade
Providing and fixing of Sign Board (Danger Board) on Distribution Transformer Centers Made out of 2mm aluminium sheet size 300x300mm
(1x1ft) as per design, pre treated with phosphate process and acid etching coated with one coat of epoxy primer and two coats of best quality
paints, refloctrorised with Hi-Intensity retroreflective sheeting as per the latest and frame fabricated from suitable size iron angle. The Sign
Board (Danger Board is to be fixed at the location as per instruction of In-charge Engineer. (a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W) from 3 mm aluminium sheet along with 1.0 mm dia aluminium binding
29 9925000029 wire for fixing of aluminium tag near end termination joint at DP structure for identifyng the cable. The details of feeder i.e. 11 / 22 KV with No.
feeder name shound be punched on the tag by letter punch of size 16 mm as per instruction of In-charge Engineer.
30 9925000030 Supply & fixing of heat shrink type end terminations (outdoor) for 11kV 3C x 240 mm2 size XLPE cable as per DGVCL technical specification No.
31 9925000031 Supply & fixing of heat & shrinkable end terminations (outdoor) for 22 kV 3C x 240 mm2 size XLPE cable as per DGVCL technical specification) No.
32 9925000032 Supply & fixing of heat shrink type end terminations (indoor) for 11kV 3C x 240 mm2 size XLPE cable as per DGVCL technical specification) No.
33 9925000033 Supply & fixing of heat & shrinkable end terminations (indoor) for 22 kV 3C x 240 mm2 size XLPE cable as per DGVCL technical specification No.
34 9925000034 Supply & fixing of heat shrinkable straight through joint for 11kV 3C x 240 mm2 size XLPE cableas per DGVCL technical specification. No.
35 9925000035 Supply & fixing of heat shrinkable straight through joint type for 22kV 3C x 240 mm2 size XLPE cable as per DGVCL technical specification No.
Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible, RRL type- 3 Way RMU including Two numbers of earthings as per
Drawing (material is in bidder's scope) and as per DGVCL Technical specification.
Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible, RRLL type- 4 Way RMU including Two numbers of earthings as per
Drawing (material is in bidder's scope) and as per DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA Compatible, RRL type-3 Way, RMU including Two numbers of earthings as per
Drawing (material is in bidder's scope) and as per DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA Compatible, RRLL type-4 Way, RMU including Two numbers of earthings as per
Drawing (material is in bidder's scope) and as per DGVCL Technical specification.
Construction of plinth for 11KV, RRL type- 3 Way (i.e Two numbers of Isolator & One number of Breaker) Ring Main Unit as per DGVCL's
technical specification mentioned in drawing no: Drg. 11kv-01. All required material will be supplied by contractor.
Construction of plinth for 11KV, RRLL type- 4 Way (i.e Two numbers of Isolator & Two number of Breaker)Ring Main Unit as per DGVCL's
technical specification mentioned in drawing no:Drg. 11kv-02.All required material will be supplied by contractor.
Construction of plinth for 22KV, RRL type- 3 Way (i.e Two numbers of Isolator & One number of Breaker) Ring Main Unit as per DGVCL's
technical specification mentioned in drawing no: Drg. 22kv-01. All required material will be supplied by contractor.
Construction of plinth for 22KV, RRLL type- 4 Way (i.e Two numbers of Isolator & Two number of Breaker)Ring Main Unit as per DGVCL's
technical specification mentioned in drawing no:Drg. 22kv-02.All required material will be supplied by contractor.
Modifications e.g.Providing and fixing of Terminal protectors i.e. Re-use able boot (HT Side 11/22KV, LT Side 1.1KV) including 11/22 KV
insulating taps and L.T.(1.1 KV) insulating taps ,Busbar, Tapping from Bus Bar (11/22 KV XLPE cable) through P.G. Clamp for H.T. Jumper to
D.O. Fuse to bushings of Transformer Center, providing & Fixing of jumper and providing & fixing of Heat Shrinkable Anti Tracking Core
44 9925000046 Insulating Tubing (Insulation Level 11/22 KV) in H.T. jumper , Clamping arrangement of cable support frame on both side of existing Over Head No.
type Distribution Transformer to utilize in Under Ground cable network as per drawing & as per instruction of Engineer incharge. All live parts
i.e. PG-Clamp, connections of D.O.fuses, HT bushings etc . shall be covered with fixinng of 11/22 KV HT insulating tapes. ( 11/22 KV XLPE cable
will be in scope of DGVCL while all other materials will be in bidder's scope ) .
45 9925000047 Laying of any size of 11/ 22 KV XLPE /PILC Cable in redaymade trench or in open space Per Cable Per Mtr
46 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
47 9925000064 Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC half round pipe No.
48 Dismental OF 100MM2 AAAC CONDUCTOR KM
49 Dismental OF 34/55MM2 AAAC CONDUCTOR KM
RUPEES IN WORDS: THIRTY LAKH ONLY
EXE. ENGINEER (O&M);
DGVCL, DHARAMPUR DN.
1. DGVCL will provide key material like M.S. materials,ABC/Bare conductors,PSC/RSJ Poles,Insulators,Fabricated materials etc. to the contractor.
2.All fabricated items shall be fabricated as per DGVCL approved drawing and by welding rods confirming to the relevent ISI specification and as directed by Engineer in charge.
3.Necessary electricity connection for fabrictated items shall be provided by DGVCL on payment of required charge for connection & electricity bill of the same shall be paid by the agency.
4.All the rates are inclusive of PF and Exclusive of GST applicable time to time.
5.All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles & steel fabricated materials of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ poles & steel fabricated materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver paint) is to be properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC poles.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender notice.pdf
TECHNICAL SPECIFICATION.pdf
SCHEDULE-B.pdf
GENERAL TERMS CONDITION.pdf
Document.pdf
Bid Document.pdf
Bank detail for paymnet.pdf
5.INTIGRITY PACT.pdf
2.BANK DETAILS422.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .