Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹87.4 LAccepted-Finance | ₹87.4 L | 1 | Accepted-Finance L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical As per Attached TER |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
2 Mar 2021, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, Research Circle, Irrigation Research Institute, Roorkee
Electrical fitting, Furnishing and Installation of other accessories in SWIC building at Roorkee under National Hydrology Project (NHP)
2020_IRDCE_28326_2
10/SE (R)/ NHP/ e-Tender/ 20
Open Tender
Civil Works
Item Wise
90 days
Roorkee
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,720
Executive Engineer, Design Division, IDO, Roorkee
₹2.2 L
Roorkee
8 Sept 2023
1 Feb 2021
2 Mar 2021
1 Feb 2021
2 Mar 2021
20 Feb 2021
8 Feb 2021
Laying and Jointing PVC Pipe. Heading
Point wiring with 2 nos of 1.5mm PVC FRLS wire and 1 run1.5mm for earth in receess/ surface32mm/25mm pvc conduit with all accessories including modular switches and plates as required. GROUP C
Point wiring with 2 nos of 1.5mm PVC FRLS wire and 1 run1.5mm for earth in receess/surface 32mm/25mm pvc conduit with all accessories including modular switches and plates as required. GROUP WIRING
Supplying and Wiring for circuit wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2runs4 sq.mm. & 1runs 4 sq.mm earth wire
Supplying and Wiring for circuit wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2runs2.5 sq.mm. & 1runs 2.5 sq.mm earth wire
"S/F of following sizes of PVC conduit along with accessories in surface/recess including cuttting the wall and making good the same (25mm)"
S/F of SP MCB C curve 10KA 6-32A as per load requirements
S&F of 16A switch socket with plate and gi box reccess in wall complete with all finishing work
Supply, Installation, testing & Commissioning of 2 pole structure suitable for 11 KV HT system fabricated in ISMB suitable cross channals MS angle, required number of disc insulator ,Air break switchs with GI operating handle, HG fuse or drop out fuses, pin insulators, lighting arrestor, post insulator,"O"SWG copper jumpers to connect HV bushing of the transformer etc. with GI fastners with down earthing provision in the pole duly painted two coats of aluminium paint over a coat of red oxide primer as per CEIG/CEI regulation and IE rules. a) 3pin AB Switch -2sets b) Disc insulated with metal parts-2sets c) post top insulators -3sets d) Drop out or HG fuse unit -1 set e) Lighting arrestors complete assembly upto earth point -2 sets f) "O"SWG copper jumper-15set g) 25X3mm coper flat for structure earthing-50 RM h) 25 X 6mm copper flat for LA earthing-20RM
HT switchgear: 11kV 21kA TP 800AVaccum Circuit Breaker with panelMaster Trip, Auxilliary & IDMT Relays, Annunciator, RYB-ON-OFF-Trip-Healthy Circuit Indication Lamps, ON-OFF Push Buttons, Ammeter, Voltmeter, HT 25/5A CT Unit, Potential Transformer, with SC/ OC/ Transformer protection as required
SITC OF OIL COOLED SERVO TPINPUT TPOUTPUT as per site load (300 kva approx)
BY PASS SWITCH
HT CABLE 95X3 11 KV ALUMINIUM ARMORED (UE)
"SITC of 250 KVA, 11000 / 415 volts, outdoor oil type naturally cooled Transformer(TR) copper winding with vector group Dyn 11, and of + 10% to -10% on HT side in steps of 2.5% with RTCC 415 volts on LT side, TR to be provided with cable box on HT side to receive upto 3 core 185 sq.mm. XPLE cable and LT side bus bar chamber to receive LT side to require3x3.5x 400sq.mm XLPE cable complete as required and as per specifications and followings with latest IS: 1180 (level II). (a) Winding Temp. Indication (WTI) with alarm (b) Oil Temp. Indicator (OTI) with alarm (c ) Buchholz relay with releae cock, alarm, contacts for trip and alarm (d) Bidirectional rollers (e) First filling of filtered dehydrated oil as per IS: 335 including make up fill during installation (f) Oil conservator with filter cap, drain plug & oil level gauge"
Supply, Testing, laying LT Cable AL. ARMORED 240X3.5 AL ARMORED XLPE 1.1 KV recess, trench underground
Supply, Testing, laying LT Cable AL. ARMORED 95X3.5 AL ARMORED XLPE 1.1 KV recess, trench underground
Supply, Testing, laying LT Cable AL. ARMORED 6 mmX2 AL ARMORED XLPE 1.1 KV recess, trench underground
Supply, Testing, laying LT Cable AL. ARMORED 10 mmX4 AL ARMORED XLPE 1.1 KV recess, trench underground
Supply, Testing, laying LT Cable AL. ARMORED 50 mmX3.5 AL ARMORED XLPE 1.1 KV recess, trench underground
Supply, Testing, laying LT Cable AL. ARMORED 16 mmX4 core
Supply and Wiring for circuit alongwith earth FR wire with the following sizes of PVC insulated copper conductor, single core cable laying in surface/ recessed PVC conduit as required.4runs10 sq.mm. & 2runs 6 sq.mm earth wire
supplying and Wiring for circuit wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable laying in surface/ recessed PVC conduit as required.4 runs 6 sq.mm. & 2 runs 4 sq.mm earth wire
P&F laying COPPER ARMORED CABLE 16MMX 4 CORE
Supply & insta.COPPER CABLE 11 KV 6MM X 4 CORE
supply & laying of 2.5MMX 3 CORE COPPER CABLE ARMORED 11kv insulated xlpe
supply & laying of 6.0MMX 1 CORE COPPER flexible wire 11 kv xlpe
Supplying OF end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required. 3.5 x 240 sq.mm.
Supplying OF end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required. 3.5 x95/50 sq.mm.
P&F OF MCB FP 16A
COPPER WIRE 8 SWG FOR EARTHING
P&F OF LED GATE LIGHTS BIGGER SIZE AS APPROVED
S&F OF POWDER COATED 15MM DIA FAN ROD 900MM (36") COMPLETE WITH ALL ACCESSORIES
LA Electrode with mast : Early Streamer Emission type Air Terminal with 40 Mtrs Level 1 Protection on 5 Mtrs mast as per NFC 17-102 including 5 Mtrs GI Mast with stay wires, foundation bolts, hardware etc. for fixing
Supply and installation of perforated type cable trays of the following sizes fabricated out of perforated hot dip galvanized MS sheets of minimum 2 mm thick with 50 mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc as per drawings/site condition and rate shall include all support hardware including cost of GI anchor fasteners, screws, nuts, bolts MS Bar & Angle iron etc for hanging arrangement complete as required. 150x 50mm
Supply and installation of perforated type cable trays of the following sizes fabricated out of perforated hot dip galvanized MS sheets of minimum 2 mm thick with 50 mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc as per drawings/site condition and rate shall include all support hardware including cost of GI anchor fasteners, screws, nuts, bolts MS Bar & Angle iron etc for hanging arrangement complete as required. 300x 50mm
P&F of RCBO 16A DP 100MA
P&F of RCBO 63A FP 100MA
P&F OF BULK HEAD LED LIGHT WEATHERPROOF OUTDOOR TYPE
P&F FOCUS LED LIGHT 20 WATT DECORATIVE SWIVEL TYPE up/down WITH MIRROR REFLECTOR COMPLETE WITH ALL ACCESSSORIES CEILING /WALL MOUNTED 4000K
Supplying, installation, testing and commissioning of 15W, 5700 K surface LED panel having system Luminous efficacy of not less than 100lm/W complete with white powder coated spun Al. housing, methacrylate opel diffuser, dependent electronic integrated driver <10% THD with output short circuit protection, surge voltage protection etc. on the existing ceiling i/c making connections etc. complete as required. (Havells B46 or equivalent in Phillips/ Crompton/Syska)
Supplying, installation, testing and commissioning of 15w, downlight ma de of pressure die cast aluminium LED having system Luminous efficacy of not less than 100lm/W complete with white powder coated spun Al. housing, methacrylate opel diffuser, dependent electronic integrated driver <10% THD with output short circuit protection, surge voltage protection etc. on the existing ceiling i/c making connections etc. complete as required. Havells B46 or equivalent in Phillips/Crompton/Syska)
Supplying, installation, testing and commissioning of 15w, downlight ma de of pressure die cast aluminium LED having system Luminous efficacy of not less than 100lm/W complete with white powder coated spun Al. housing, methacrylate opel diffuser, dependent electronic integrated driver <10% THD with output short circuit protection, surge voltage protection etc. on the existing ceiling i/c making connections etc. complete as required. (Havells B46 or equivalent in Phillips/Crompton/Syska)
Supplying of Ultra bright LED Tubelight (double side connection) with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in LED Batten 1x22W LED Tube (Double Side) to give glare FRLSee light. (20 W LED Tube 4 ft. lenght with LED batten)
P&F GI STRIP 32 X 5
P&F CU. STRIP 25 X 3
Supplying & installation of Bimetallic Test joint links as required.
Supply of advance maintenance free Chemical Gel GI Earthing of Dual Pipe Technology (GI) o of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permanent sealings at both the ends with the lead terminal of 32x10mm size at the top along with 50 Kgs of RESLOW mixture of Resistance Lowering Grounding Minerals. The loss on ignition by mass of the chemical compound shall be less than 20%. The chemical compound should be tested and certified by any International accredited and BIS (Bureau of Indian Standards) accredited laboratory. The CHEMRODE shall be duly tested & certified by CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 30 KA rms. The chemical earth electrode manufacturer shall be an ISO 9001:2008 & ISO 14001:2004 certified organization. The Earth pit should be covered with heavy duty polyplastic weather proof chamber.
Supply of advance maintenance free Chemical CU Earthing of Dual Pipe Technology CU. of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permanent sealings at both the ends with the lead terminal of 32x10mm size at the top along with 50 Kgs of RESLOW mixture of Resistance Lowering Grounding Minerals. The loss on ignition by mass of the chemical compound shall be less than 20%. The chemical compound should be tested and certified by any International accredited and BIS (Bureau of Indian Standards) accredited laboratory. The CHEMRODE shall be duly tested & certified by CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 30 KA rms. The chemical earth electrode manufacturer shall be an ISO 9001:2008 & ISO 14001:2004 certified organization. The Earth pit should be covered with heavy duty polyplastic weather proof chamber.
P& F OF HT KITS 95X 3 COMPLETE WITH SHRINKABLE SLEEVES INDOOR/OUTDOOR
P& F STREEET LIGHT TIMER PANEL BOX COMPLETE
Supplying and fixing of 6mtr long decorative type GMS pole with base frame. The pole to be erected on cement concrete foundation of 1:2:4 with collar including 16A DP MCB & Busbar & excavation in all type of soil as required, painting etc complete in all respect. (Make:- Havells/Bajaj/Twinkle).
One (1) Set Auto-Mains Failure Relay with Auto/Manual/Test modes, including cranking relay, interrupt and annunciator window & hooter for abnormal conditions of Engine faults, Electrical Faults, failure to Start or Stop, low fuel, reverse power protection etc. External Auto-Manual System to bypass AMF Relay to be provided in case of failure of relay including all equipment for AMF Operation like A/M Switches, 24/12V Battery Charger, DC Voltmeter, DC Ammeter, Mains / DG Indiction Lamps
Supply Installation testing and commissioning of main LT Panel( 300KVA LOAD changeover for DG and APFC power factor auto controller 100 kvr including all M, L, T & P etc. (per unit) I/C 400A/630A FP MCCB O/G320-1,200-1 & 16 nos mccb(160-250A) for other euipmets,fire pumps and motors along with spreader links , rotary handles,change over ,APFC relay and MFM accessories
S//f of Sub Distribution Panel (per unit) including all cost of M.L.T. & P etc.I/C 200A/400A FP MCCB O/G ,20 nos 40/63FP mccb mcbs spreader links ,rotary handles ,digital metering with indicato MFM and protection mcbs
S/f of UPS Panel with auto trnsfer mechanism (ATS) programmed to auto control 2 nos of UPS complete per unit including all cost of M.L.T. & P etc.125a fp mccb ,9 32fp mcbs 40a fp contactor spreader links,digital metering MFM 2 nos indiaction with mcbs
S/f of AC Distribution Panel per unit copper busbar 500a arrangement to supply 6 nos upto 250a mccbs including all cost of M.L.T. & P etc. 320a/400a FP I/c mccbs 6 nos mccb 125a/160a fp spreader links ,rotary handles with digital metring and mcb protection & provision for 3 nos 125A tp mccbs
S/f of 6WAY VTPN with MCCB Incomer 125AVTPN DBS per unit including all cost of M.L.T. & P etc.
S/f of 8WAYV TPN with MCCB Incomer 125AVTPN DBS per unit including all cost of M.L.T. & P etc.
S/f of 4WAY VTPN with MCCB Incomer 125AVTPN DBS per unit including all cost of M.L.T. & P etc.
S/f of 125A TP MICRO PROCCESS BASED MCCB per unit including all cost of M.L.T. & P etc.
S/F of exhaust fan 200 250mm with louvers
s/f of ceiling fans 1200mm five star rating with neccassary clamps and fan rods as required
S&Ll of 1.5mm x 2 core copper flexible cable FR in existing pvc conduit
Supply, installation, testing & commissioning of wall mounted distribution boards, MS powder coated, Factory Fabricated, double door IP43 design, dust & vermin proof suitable for operation on 415/230 Volts 50 HZ A.C. supply system conforming to specification and as per drawing, complete with internal wiring, Copper busbar, neutral and earth bars, mounted with specified equipment & accessories as required of approved make6 WAY THREE PHASE & NEUTRAL
Providing & fixing of False Ceiling, Wall Panelling & Floor Covering
Providing & fixing in position wall panelling at all heights of thickness 25 mm with Credence Fiber Glass Acoustical Wall Panels of size 600x1200 mm creda, resin bonded square edges having NRC of 0.9 minimum. The panels should be manufactured from high density bio-soluble resin bonded glass wool absorber having density of 96 Kgs/m3 and wrapped on the front side with an acoustically transparent fabric having option of colours and fabric type like jute, etc. as per approved by architect/engineer-in-charge, plain tissue backer and fabric wrapped hardened edges. Panels should have humidity resistance up to 90 %, thermal conductivity ≤ 0.03 (m² k / w) thermal resistance ≥ 0.9 (m² k / w) & moisture rate ≤ 1% (JC/T670 – 2005). The panel should be fully recycled and fire retardant as per Class A. The installation comprises a GI framework for acoustic wall panelling as per design drawing (made from especially fabricated galvanized iron sheets 0.55 mm thick pressed section galvanizing @ 120 grams per sqm including both sides) consisting of floor channel of size 50X32X32X0.55 mm thick bottom and top fixed with nylon sleeves and screw. Further vertical GI studs of size 48X34X36X0.55 mm thick are placed at 600 mm center to center vertically on the wall using 12 mm dia 50 mm long wedged type expanded zinc alloy dash fastener with 10 mm bolt, to avoid any undulations on the wall. The extra channel must be used at openings and junctions as required. Further, wooden batten/ply of 6mm thickness and a width of 5” to be placed at 600 mm center to center horizontally on the vertical GI Studs. Surface impalers of size 3”X4” having projecting element called spikes shall be fixed on the wooden batten surface at 1200 mm center to center horizontally and 600 mm center to center vertically, using self tapping screws. Silica based construction adhesive to be dabbed on to the projecting elements (spikes) of the impalers. Wall Panels shall be pierced through the spikes of the impalers ensuring line & level of panel are maintained. The panels should be mounted on the impalers horizontally or vertically as per the approved design or as per the directions of the engineer-in-charge.
"Providing and fixing Credence soft fiber acoustical false ceiling micro-look edged tiles astra at all heights of size 595X595X15 mm. The tiles should have Humidity Resistance (RH) of 99%, thermal insulation ≥ 0.5 (m² k / w) & moisture rate ≤ 1% (JC/T670 – 2005), light Reflectance of >85%, textured front surface and fire retardant as per Class A in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.30 mm thickness (galvanized @120 gsm) comprising main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 15mm thick micro-look soft fiber false ceiling tile (NRC 0.9 to 1) as per the directions of the engineer-in-charge."
"Providing and fixing in position wall panelling of Credence channelled Wood panels esto of width 128mm, thickness of 16mm and length 2440 mm made up of high density fiber board with minimum density of 800 Kg/m3 substrate with a laminated facing / wood veneer as per the approved shade / species & finish with melamine balancing layer on the reverse side. The boards shall have a special perforation pattern of 2mm groove & 14mm pitch. The panels shall have fire resistance of Class I, BS 476 part 7. The edges of the panels shall be “tongued-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece and backed with 50mm thick glass wool layer as directed by the Engineer-in-Charge. The panel shall be mounted on special channels using clips as approved by the Engineer -in-charge. Install G.I stud of section 48X34X36 mm or as approved by the Engineer -in- Charge on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium channel (keel) vertically on channelled G.I stud 600mm centre to centre. Install the first set of wooden panels by inserting the clips. For border channel insert the groove of the panel in to the projecting flange of the aluminium clip. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channel into the next aluminium channel (keel) and simultaneously fill the gap between wall & panel by 50 mm thick glass wool having density of 48 kg/m3. Continue the process till the actual height is achieved. Use clips for border channel to finish off the installation, finish the edges using wood moulding of matching colour as approved by Engineer-in- Charge. The installed panels should give an NRC minimum of 0.9. as per the directions of the engineer-in-charge."
Providing & Fixing of Flocked textile floor covering of Nylon 6.6 face fiber or equivalent of approved make with 100% Nylon and completely water proof resilient backing. The flooring should be Anti static with thickness of 4.3 mm and approximate weight of 1.8 k.g./sqm of roll form. The carpet should be completely stain resistant and of a density approx. 80 million fibers/sq.mtr (70 million fiber/sq.yd) in the width of 2 mtr .The floor covering should have Fire Test EN-13501, Appearance Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, SANITISED anti-microbial treatment, with resilient waterproof backing, anti allergic which is certified by British allergy foundation, with ten year replacement guarantee. The carpet should have permanent static control & should be fixed with powder coated aluminum angles as per detail. Aluminum angles to be paid separately. The work should be carried out by the authorized installer of the Company as per the directions of the engineer-in-charge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].