| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹30.5 L+₹5.6 L (22.3%)Rejected-Finance 17 1305 ARIAKATTU PALLURUTHY KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹33.6 L+₹8.6 L (34.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹39.6 L+₹14.6 L (58.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹39.9 L+₹14.9 L (59.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
23 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2022_MES_572028_1
8186_GE_NW
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE_NW_KOCHI
₹92,000
Yes
27 Feb 2023
29 Dec 2022
25 Jan 2023
29 Dec 2022
23 Jan 2023
11 Jan 2023
29 Dec 2022 - 16 Jan 2023
Amount
Taking down copper/aluminium point wiring (light, fan, bell, socket or power etc.) complete with all accessories like switches, sockets, regulators, ceiling roses, light fittings etc. for taking credit and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floors / ceiling etc complete all as specified and directed.
M/L for Surface point wiring with 1.5Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable in and including ISI Marked, medium grade, non metallic, Fire Resistant PVC Casing & Capping and all accessories, medium grade PVC surface Box with top cover plate, 1.5Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity conductor and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floor / ceiling etc complete all as specified and directed for One light point controlled by one switch
All as per item No.2, but for One ceiling / exhaust fan point controlled by one switch
All as per item No.2, but for One 3 pin socket outlet, 5 Amps controlled by one switch in same board with other switches
All as per item No.2, but for One 3 pin socket outlet, 5Amps controlled by one switch independent
All as per item No.2, but for One bell point controlled by one bell push on same board or independent
All as per item No.2 above but for One 3 pin socket outlet, 15Amps controlled by one switch independent with 2.5 sqmm cable and 2.5Sqmm cable as earth wire on independent board complete all as specified and directed.
S&F Switch piano flush type, 5A, AC, 240V, one way ISI Marked complete all as specified and directed.
S&F Bell Push, Flush type, 5A, AC, 240V, ISI Marked complete all as specified and directed.
S&F Socket piano flush type, 5A, 5pin, AC, 240V ISI Marked complete all as specified directed.
S&F Socket piano flush type, 15A, 6pin, AC, 240V ISI Marked complete all as specified directed.
S&F Power Unit suitable for AC / Geyser, 20A, 3pin, AC, 240V ISI Marked incl PVC Surface Box complete all as specified and directed.
S&F Electronic 5 Step Fan Regulator, 240V, AC, ISI Marked complete all as specified and directed.
S&F in repairs switch piano flush type, 5A, AC, 240V, one way ISI Marked complete all as specified and directed.
S&F in repairs switch piano flush type,15A, AC, 240V, one way ISI Marked complete all as specified and directed.
S&F in repairs Bell Push, Flush type, 5A, AC, 240V, ISI Marked complete all as specified and directed.
S&F in repairs socket piano flush type, 5A, 5pin, AC, 240V ISI Marked complete all as specified and directed.
S&F in repairs socket piano flush type, 15A, 6pin, AC, 240V ISI Marked complete all as specified and directed.
S&F in repairs Power Unit suitable for AC / Geyser, 20A, 3pin, AC, 240V ISI Marked incl PVC Surface Box complete all as specified and directed.
S&F in repairs Electronic Step type/ switch type Fan Regulator, 5 step, 240V, AC, ISI Marked complete all as specified and directed, as per site requirement.
S&F in repairs Ceiling rose surface Bakelite 65x50mm, 3 terminals, AC, 240V, ISI Marked and as specified.
S&F in repairs Call Bell, AC, 240V, SP, ISI Marked complete all as specified and directed.
S&F in repairs lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings, AC, 240V, Pin type, ISI marked and as specified.
S&F in repairs switch socket combination 2 in 1, 5 amps flush type suitable for 2/4 screws as per site requirement complete all as specified and directed.
S&F in repairs switch socket combination 2 in 1 3 pin, 5/15 amps flush type suitable for 2/4 screws as per site requirement complete all as specified and directed.
S&F in repairs Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked and as specified of existing make and type complete all as specified and directed.
S&F in repairs Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked and as specified of existing make and type complete all as specified and directed.
S&F in repairs Modular Bell Push, 1 module, 6A, AC, 240V, ISI Marked and as specified of existing make and type complete all as specified and directed.
S&F in repairs Modular Step Fan Regulator, 2 module, 120W, AC, 240V, ISI Marked and as specified of existing make and type complete all as specified and directed.
S&F in repairs Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, ISI Marked and as specified of existing make and type complete all as specified and directed..
S&F in repairs Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked and as specified of existing make and type complete all as specified and directed..
M&L in repairs for sub main wiring with 2 runs of 4Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable drawn in and including ISI Marked, medium grade, non metallic, Fire Resistant PVC Casing & Capping and all accessories, with 1 run of 4.0Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity wire and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc including taking old wiring complete all as specified and directed. Note:- Three run of cable and one run of PVC casing and caping shall be measured as one unit
M&L in repairs for sub main wiring with 2 runs of 6 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable drawn in and including ISI Marked, medium grade, non metallic, Fire Resistant PVC Casing & Capping and all accessories, with 1 run of 6.0Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity wire and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc all as specified including taking old wiring complete all as specified and directed. Note:- Three run of cable and one run of PVC casing and caping shall be measured as one unit
M&L in repairs for sub main wiring with 4 runs of 6 Sqmm PVC insulated copper conductor multistranded cable drawn in and including PVC conduit including two run of 6 Sqmm multi stranded copper conductor cable for earth continuity wire complete all as specified and directed. Note : Four runs of PVC cable 6 sqmm and two run of 6 sqmm earth continuity conductor cable as earth continuity wire and pic conduit will be measured as one unit length .
M&L in repairs sub main wiring with XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 4 core including all fixing arrangement complete all as specified and directed.
Taking down existing sub main LT cable of any type and refixing the same as directed with clamps, saddles, screws complete all as specified and directed.
S&F in repair SPN DB, 240V, AC, 2 way, double door with 200Amps rated busbar ISI Marked complete all as specified and directed.
All as per item no.33 above but 4 way with 200Amps rated busbar complete all as specified and directed..
All as per item no.33 above but 8 way with 200Amps rated busbar complete all as specified and directed..
All as per item no.33 above but TPN DB, vertical mounting, 415V, 4way with 200Amps rated busbar, double door.
S&F in repair MCB SP 6 to 32 A, AC, 240V, 10KA, ISI Marked complete all as specified and directed.
S&F in repair Isolator DP, 40A, AC, 240V, 10KA, ISI Marked complete all as specified and directed.
S&F in repair Isolator 4P, 63A, AC, 415V, 10KA ISI Marked complete all as specified and directed.
S&F in repair RCCB / ELCB, double pole, AC, 40A, 30mA, 240V ISI Marked complete all as specified and directed.
S&F in repair RCCB / ELCB, 4P, AC, 63A, 30mA, 415V ISI Marked complete all as specified and directed.
S&F 4 feet surface mounted batten type 20W LED luminaire with emergency light output, with maximum 4 hours battery backup in case of power failure with Li battery, luminaire efficacy 100 lm/w with an operating voltage range from 140V-270V, initial lumen at battery mode will reduce to 35-50%, charging time approx. 8-12 hours. The luminaire shall have aluminium extruded main housing. PC LED front cover. The luminaire shall have a CCT of 6500K, CRI>80. Power factor hours as per L70 B50 criteria. The luminaire shall be EMI/ EMC complaint and shall have open and short circuit protection, reverse polarity protection, internal surge protection of 30 KV IP 20 ingress protection complete all as specified and directed.
Note for item No. 46 (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid, Seoul semiconductor. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaire respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for a period of 02 years.
S&F in repairs Regal Batten 1x22W for LED tube lights, both side connection type complete all as specified and directed.
S&F in repairs for LED Mirror light fitting 8 watt with connected accessories complete all as specified & directed.
S&F in repairs LED tube rod 1 x 20 Watt, both side connection complete all as specified and directed.
S&F in repairs LED tube rod 1 x 20 Watt, single side connection complete all as specified and directed.
S&F in repairs 1x15 Watt LED down lighter square / round in shape surface mounted type and connecting to the existing electrical system complete all as specified and directed.
S&F in repairs existing holder, 12w LED Bulb with B22 base, clear acrylic diffuser, Self declaring R No, power factor .90, 100 lumens light output.
S&F in repairs existing holder, 5w LED Bulb with B22 base, clear acrylic diffuser, Self declaring R No, power factor .90, 85 lumens light output.
M&L Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. .
All as per item No. 56 above but for metallic body exhaust fan 250 to 450 mm sweep complete all as specified and directed.
M&L for rewinding of Ceiling Fan 1200mm Sweep of any make, any model, from a reputed workshop, removing the burnt winding, cleaning slots, re-winding the motor with super enamelled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc, replacement of body screws, testing and commissioning on full load for 8 hrs. continuous running complete all as specified and directed.
All as per item No. 58 above but for Ceiling Fan 1400mm Sweep
All as per item No. 58 above but for Wall Fan 400mm Sweep
All as per item No. 58 above but for Exhaust Fan unto 300mm Sweep
All as per item No. 58 above but for Exhaust Fan 450mm Sweep
S&F in repairs, Condenser / Capacitor, 2.5 mfd, 240V, AC, suitable for fans complete all as specified and directed.
S&F in repairs, Condenser / Capacitor, 4.0 mfd, 240V, AC, suitable for fans complete all as specified and directed.
S&F, in repairs Ball bearing made out of high carbon steel, equivalent to the original, suitable for any type, any make, any size fans complete all as specified and directed.
S&F, in repairs Bush bearing, made out of brass alloy, equivalent to the original, suitable for any type, any make, any size, fan complete all as specified and directed.
S&F, in repairs Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size complete all as specified and directed.
S&F, in repairs Down rod, suitably threaded and holed, made out of 15mmdia GI tubes, duly painted, 300mm long, suitable for ceiling fans any type, any make, any size all as directed of any length as per site requirement complete all as specified and directed.
S&F, in repairs Fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans any type, any make, any size complete all as specified and directed.
S&F, in repairs Rubber reel insulator, suitable for ceiling fans any type, any make, any size complete all as specified and directed.
S&F in repairs Fan blades for 1200mm Sweep ceiling fan made out of 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with White or Brown colour complete all as specified and directed.
All as per item No. 71 above but for1400mm Sweep fan
S&F in repairs Fan blades made out of Acrylic / PVC alloy and MS screws duly balance suitable for 450mm wall fans of any type, any make complete all as specified and directed.
S&F in repairs Fan blades made out of 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with approved colour, suitable for 300mm Sweep Exhaust fans of any type, any make complete all as specified and directed.
S&F in repairs Fan blades made out of 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with approved colour, suitable for 450mm Sweep Exhaust fans of any type, any make complete all as specified and directed.
S&F, in repairs Split pin made out of Nickel plated mild steel with specified temper, suitable for ceiling fans of any type, any make with bolts of any size complete all as specified and directed.
S&F, in repairs Bakelite body Chrome connectors, 2 way with fixing screws of suitable size for ceiling fans of any type, complete all as specified and directed.
S&F in repairs energy efficient ceiling fan of 1200mm sweep (5 star rated) 230 Volt 50 Hz including all electrical connection all as specified and as directed and taking down old one and deposited to MES store yard complete all as specified and directed.
S&F in replacement PVC body exhaust fan motor suitable for 250/300 mm of any make as per site requirement complete all as specified and directed.
S&F in replacement exhaust fan motor suitable for metallic body exhaust fan of any make and type of 250 mm sweep complete all as specified and directed.
S&F in replacement motor for 400 mm, PVC body wall fans any make as per site requirement complete all as specified and directed.
S&F PVC body wall fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed.
S&F 250mm sweep, PVC body exhaust fan heavy duty, single phase 230 Volts, complete all as specified and directed. Note : Old fan shall be deposited in MES store yard.
S&F in replacement Hylem sheet of 3 mm thick as per site requirement including cutting for accommodating existing switches, sockets, regulators complete all as specified and directed.
S&F in replacement white cover plate with frame for modular switches of one module complete all as specified and directed as per site requirement of Same make and type.
S&F in repairs white cover plate with frame for modular switches of two module complete all as specified and directed.
S&F in repairs white cover plate with frame for modular switches of three module complete all as specified and directed
S&F in repairs white cover plate with frame for modular switches of four module complete all as specified and directed
S&F in repairs white cover plate with frame for modular switches of six module complete all as specified and directed
S&F in repairs Decorative wall light fixture made up of Polycarbonate, suitable for 10 W retrofit LED Lamp B22 base complete all as specified and directed.
S&F in repairs Heating element, suitable for any type, any make geyser, 240V, AC, ISI Marked, with heat resistant rubber washer, for1.5 KW capacity, connecting complete all as specified and directed and including taking down if required.
S&F in repairs Thermostat control unit suitable for any type, any make 25 Litres capacity geyser, 30-90 degree rating, 240V, AC, ISI Marked, connecting complete all as specified and directed and including taking down if required.
S&F in repairs indicating lamp unit round / rectangular type, suitable for any type, any make geyser, standard quality, AC, 240V, Red or Green, connecting complete all as specified and directed.
S&F in repairs fusible plug made out of brass with internal or external threading suitable for any type, any make Geyser of capacity 25 Litres complete all as specified and directed.
S&F in repairs Inner assembly made out of brass with chromium plating, with heat resistant rubber washer, suitable for any type, any make Geyser of 25 Litres capacity, ISI marked, including taking down if required complete all as directed
S&F in repairs inner tank made out of cast copper alloy, ISI Marked, suitable for any type, any make geyser of 25 Litres capacity, for the following capacities including taking down if required complete all as directed
S&F in repairs Metallic Outer cover including bottom and top cover duly painted suitable for any type, any make geyser of 25 Litres capacity complete all as specified and directed.
M&L in repairs to any type, any make geyser of 25 Litres capacity metallic inner tank, arresting the leakage by welding, brazing etc, pressure testing after repairs, complete all as specified and directed.
M&L for filling the glass wool between outer cover and inner tank of any type, any make Geyser, 25 litres capacity, complete all as specified and directed.
M&L for Preparing the surface of any type, any make geyser of 25 Litre capacity, remove the existing painting by scraping, cleaning, filling the cavities and applying 2 coats of spray paint with synthetic enamel white paint over a coat of red oxide primer, including taking down if required and writing the MES Nos. complete all as specified and directed
M&L for Fabricate and fix, GI bottom cover / inspection plate, suitable for any type, any make geyser, 2 mm thick, split type, duly painted with 2 coats synthetic enamel paint over a priming coat of metallic primer to match with the existing colour all as directed.
M&L for replacement of bottom main terminal, synthetic gasket, fixing clamps suitable for any type, any make geyser, cleaning inner container/tank and assembly complete all as specified and directed
S&F in repairs pressure / air release valve suitable for any type, any make geyser, made out of brass 15mm bore, ISI marked, complete all as specified and directed.
S&F in repairs non-return valve, made out of brass 15mm bore, ISI marked, complete all as specified and directed.
S&F in repairs low density polyethylene pipe 16 mm dia (outer), 450mm long suitable for Hot / Cold water application complete with threaded brass union, teflon washers on both sides to suit 15 mm dia fittings complete all as specified and directed.
Material,labour,transport and tools for rectification of urgent nature electrical complaints at satellite area as and when required (Trangini apartment, Ferson apartment, DERA enclave ,Varsha ,Varuna complex and Dawson Vihar) during off hours on all working days all as directed by Engineer-in-Charge. NOTE:- (i) The material incorporated for completion of work will be measured and paid separately under relevant item. (ii) The contractor should display contact number at satellite area (Trangini apartment, Ferson apartment, DERA enclave ,Varsha ,Varuna complex and Dawson Vihar) to register users complaint. (iii) The penal recovery of Rs. 400/ complaint shall be effected if contractor fails to attend complaint within 2 hours of intimation..
Material,labour,transport and tools for rectification of urgent nature electrical complaints at satellite area(Trangini apartment, Ferson apartment, DERA enclave ,Varsha ,Varuna complex and Dawson Vihar) during Sundays and holidays all as directed by Engineer-in-Charge. NOTE:- (i) The material incorporated for completion of work will be measured and paid separately under relevant item. (ii) The contractor should display contact number at satellite area (Trangini apartment, Ferson apartment, DERA enclave ,Varsha ,Varuna complex and Dawson Vihar) to register users complaint. (iii) The penal recovery of Rs. 400/ complaint shall be effected if contractor fails to attend complaint within 2 hours of intimation..
S&F in replacement of Geysers 25 Ltrs capacity with all accessories. Including taking down old one & depositing with ME store yard complete all as specified and directed
S&F in replacement Cadmium plated screws of various types and sizes for existing switch boards with washer as per sample complete all as specified and directed
M&L for servicing of the 'DOCTOR' make water cooler by authorised company representative including replacement of Primary, Secondary and Carbon Filters as and when required & made serviceable condition for 12 months complete all as specified and directed.
M&L for checking of ceiling fan stability / tightness with fan hook once in 6 months quarter wise in complete Satellite Area and re-tightening of split pin / nut, bolt etc and as per site requirement complete all as specified and directed Note : The necessary registers duly signed by the users kept ready for any inspection.
S&F in replacement Single pole and neutral enclosure of 20 Amps with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and as directed.
S&F Plug top 15 Amps, 3 pin complete all as specified and as directed.
S&F metallic plug top 3 pin suitable for metal clad sockets of 15 Amps complete all as specified and directed.
HEAVEN ENGINEERS AND CONTRACTORS
N.O. Antony Contractors
K A ANTONY & SONS
SREENARAYANA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .