| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.5 LAccepted-AOC 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | 1 | Accepted-AOC L1 | |
| 2 | 2₹16.8 L+₹1.4 L (8.91%)Rejected-Finance | 2 | Rejected-Finance NOT L1 | |
| 3 | 3₹17.2 L+₹1.8 L (11.5%)Rejected-Finance GROUND 1 9 670 65 ADIKMET SRT COLONY VIDYANAGAR HYDERABAD 500044 | HYDERABAD | TELANGANA | 500044 | 3 | Rejected-Finance NOT L1 | |
| 4 | 4₹18.5 L+₹3.0 L (19.7%)Rejected-Finance | 4 | Rejected-Finance NOT L1 | |
| 5 | 5₹18.7 L+₹3.2 L (21.0%)Rejected-Finance | 5 | Rejected-Finance NOT L1 |
Tender Value
₹20.7 L
EMD Value
₹41,313
Closing Date
19 Dec 2019, 6:00 pmClosed
AGM EE AAI KADAPA
AGM EE AAI KADAPA
Provision of Air-Conditioners to DVOR, CCR, VIP Room and other Offices at Kadapa Airport
2019_AAI_37631_1
AAI/KDP/Engg (E)/CW-04/2019-20
Open Tender
Electrical Works
Works
60 days
KADAPA
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,180
AIRPORTS AUTHORITY OF INDIA
₹41,313
30 Jun 2021
10 Dec 2019
24 Dec 2019
10 Dec 2019
19 Dec 2019
10 Dec 2019
10 Dec 2019 - 17 Dec 2019
Amount
Supply of 5 star rated, 2.0 Ton Split Air Conditioner wall mounted type consisting of rotary type compressor & operating features like sleep mode, On/Off timer, auto restart , self diagnosys, etc, suitable to operate on 230V,50 HZ , single phase AC power supply, i/c supply of refrigerent copper piping syatem, control cable and drain piping of 04 mtr complete including voltage stabilizer of rating as recommended by OEM etc. as required as per OEM specification. (Similar to Blue Star make BS-5HW26AATU)
Supply of 5 star rated, 1.5 Ton Split Air Conditioner wall mounted type consisting of rotary type compressor & operating features like sleep mode, On/Off timer, auto restart , self diagnosys, etc, suitable to operate on 230V,50 HZ , single phase AC power supply, i/c supply of refrigerent copper piping syatem, control cable and drain piping of 04 mtr complete including voltage stabilizer of rating as recommended by OEM etc. as required as per OEM specification. (Similar to Blue Star make BS-5HW18SBTU)
Installation, testing and Commissioning of following Air-Conditioning units i/c providing and fixing of suitable MS stand for outdoor unit, electrical interconnection, drain piping, regrigerent piping system and other required civil works complete etc as required. 2.0 / 1.5 TR Single Phase Split type AC Unit (for above item 01 & 02)
Providing and fixing extra length Refrigerent Copper piping, electrical control copper cable for interconnection of indoor and outdoor units, and insulation foam for refrigerent piping etc as required for the following Air Conditioning units 2.0 / 1.5 TR Single Phase Split type AC Unit (for above item 02)
Providing and fixing extra length drain piping of size (25 mm) etc as required for following Air Conditioning units 2.0/1.5 TR Single Phase Split type AC Unit (for above item 02 & 03)
Supply & Installation of Water Cooler with inbuilt RO based water purification system with capacity 80 Ltrs (cooler storage capacity) and 50 LPH (purification capacity) similar make of Blue star Model no. SWCSDKX680ROA (stainless steel body with storage tank capacity of 80Ltrs, nominal cooling capacity 40 (Litres/hr), having two faucets, R-134A gas as refrigerant and reciprocating type compressor) complete with standard manufacture, design suitable for operation on 230 +/- 10 V, 50 Hz, AC supply.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 63A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 4 X 25 sq. mm (25mm)
Ruchira Associates
Standard Airconditioning and Refrigeration Engineers
COOL STAR
DEEPAKELECTRICALS
General Electricals and Refrigeration
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .