Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | ₹20.3 L Quoted ₹20.8 L | L1 | Accepted-AOC being lowest |
| 2 | L2₹37.4 L+₹16.6 L (79.6%)Rejected-AOC | ₹37.4 L+₹16.6 L (79.6%) | L2 | Rejected-AOC not lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
12 Nov 2020, 9:00 amClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
CERTAIN REWIRING AND REPLACEMENT OF U/S FITTINGS AND MAINT OF CEILING FAN / PEDESTRIAL FAN / WALL MOUNTED FAN / EXHAUST FAN / FLAME PROOF FAN IN TECH AREA AT SOUTH SIDE OF RUNWAY AT AF STN JODHPUR
2020_MES_387311_1
8425/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹50,000
Yes
1 Dec 2020
17 Oct 2020
13 Nov 2020
17 Oct 2020
12 Nov 2020
31 Oct 2020
Amount
Taking down carefully copper/aluminium point wiring light, fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring for One light / Buzzer point/ fan/Exhaust fan point controlled by one switch/regulator 5 Amp, SP, one way 240 volts, with 1.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable ( using colour code as per IS) 1100 volts grade drawn through drawing in existing steel /PVC conduit and terminated in existing terminal box with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, complete all as specified and directed by the Engineer in Charge.
All as per item No 2.00 above but one 3 pin 5 amp socket outlet on independent board .
All as per item No 2.00 above but for One bell point controlled by one bell push in independent board.
Material & labour for point wiring for Independent one 3 pin 15 Amps socket outlet 240 volts, with 2.5 sqmm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable ( using colour code as per IS) 1100 volts grade drawn through drawing in existing steel /PVC conduit and terminated in existing terminal box with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, complete all as specified and directed by the Engineer in Charge.
Supply & fixing switch piano 5 amps flush type single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing switch piano 16 amps flush type single pole one way complete all as specified and directed by the Engineer in Charge.
Supply & fixing socket outlet flush type 5 pin 6 amps complete all as specified and directed by the Engineer in Charge.
Supply & fixing socket outlet 2 in 1, 5 pin 16 amps flush type complete all as specified and directed by the Engineer in Charge.
Material & Labour for General Servicing of DG sets Upto 100 KVA Make- Kirloskar, Mahindra, CG , Ashok Leyland & Cummins at 250 running hours comprising of under mentioned jobs including Transportation, Labour charges & minor material (Grease, oil, nuts & bolts , washers , packing, caps etc) required for servicing etc. Complete all as specified and directed and make it functional to the entire satisfaction of the Engineer-in-Charge :- (i) Cleaning & greasing of the parts. (ii) Tappet setting as per standard. (iii) Fan belt, tensioner pulley and lever adjustments. (iv) Tightening of all the nuts, bolts and clamps. (v) Testing & checking of AC & DC Wiring. (vi) Self & Charging Alternator cleaning and testing, checking of working & minor fault removal. (vii) Checking of Supply & return fuel pipes from fuel tank to engine. (viii) Checking of FIP timing by Fuel cut off method. (ix) Replacement of defective spare/parts, these parts shall measured & paid as supply only as given in items here in after .
All as per Serial Item No.10.00 Above but DG set of capacity beyond 100 KVA & upto 250 KVA.
All as per Serial Item No.10.00 Above but DG set of capacity beyond 250 KVA & upto 400 KVA.
Supply and filling Premixed coolent Complete all as specified and directed by the Engineer-in-Charge . Make :- Volvoline/ Koel / Castrol / Fleetguard
Supply and filling in sump/topping up engine oil, multi grade 20w40 in engine or relpacement of engine oil Complete all as specified and directed by the Engineer-in-Charge . Make :- Indian oil / Hindusthan petrolium / Castrol / Pride /Servo
Material and Labour for repair to Turbo Kit of DG set having capacity upto 400 KVA make it functional to the the entire satisfaction of the the Engineer-in-Charge .
Material and labour for dismantling & opening of the radiator and fan from the engine of DG set up to 400KVA ,transporting to workshop for repair works, cleaning of copper tubes and cooling fins by using blower and finally with descaling solution, checking & detecting faults,removal of defects/faults by soldering the leakage points, do the patch work with and including replacement of defective water pumping assembly and make the radiator and fan functional to the entire satisfaction of the Engineer-in-Charge and bringing back fixed to the DG set complete all as specified & directed by Engineer-in-Charge.
Supply only diesel filter of DG set suitable for capacity up to 100 KVA Primery & secondary set complete. Make :- Mico/ Bosch / Kirloskar / Fleetguard /TATA / Cummins / Crompton Greaves.
Supply only diesel filter of DG set suitable for capacity beyond 100 KVA and upto 250 KVA Primery & secondary set complete. Make :- Mico/ Bosch / Kirloskar / Fleetguard /TATA / Cummins / Crompton Greaves.
Supply only diesel filter of DG set suitable for capacity beyond 250 KVA and upto 400 KVA Primery & secondary set complete. Make :- Mico/ Bosch / Kirloskar / Fleetguard /TATA / Cummins / Crompton Greaves.
Supply only engine oil filter of DG set suitable for capacity upto 100 KVA Primery & secondary set complete. Make :- Mico/ Bosch / Kirloskar / Fleetguard /TATA / Cummins / Crompton Greaves.
Supply only engine oil filter of DG set suitable for capacity beyond 100 KVA and upto 250 KVA Primery & secondary set complete. Make :- Mico/ Bosch / Kirloskar / Fleetguard /TATA / Cummins / Crompton Greaves.
Supply only engine oil filter of DG set suitable for capacity beyond 250 KVA and upto 400 KVA Primery & secondary set complete. Make :- Mico/ Bosch / Kirloskar / Fleetguard /TATA / Cummins / Crompton Greaves.
Supply only Air filter of DG set suitable for capacity upto 100 KVA Primery & secondary set complete. Make :- Mico/ Bosch / Kirloskar / Fleetguard /TATA / Cummins / Crompton Greaves.
Supply only Air filter of DG set suitable for capacity beyond 100 KVA and upto 250 KVA Primery & secondary set complete. Make :- Mico/ Bosch / Kirloskar / Fleetguard /TATA / Cummins / Crompton Greaves..
Supply only Air filter of DG set suitable for capacity beyond 250 KVA and upto 400 KVA Primery & secondary set complete. Make :- Mico/ Bosch / Kirloskar / Fleetguard /TATA / Cummins / Crompton Greaves.
Supply and fixing in repairs of AVR for DG set having capacity upto 63 KVA complete all specified & directed by the Engineer in Charge. Make :- Natonal / Kirloskar / Cummins / Crompton Greaves.
Supply and fixing in repairs of AVR for DG set having capacity upto 63 KVA to 160KVA complete all as directed by Engr-in-Charge. Make :- Natonal / Kirloskar / Cummins / Crompton Greaves.
Supply and fixing in repairs of AVR for DG set having capacity upto 160 KVA to 250 complete all as directed by Engr-in-Charge. Make :- Natonal / Kirloskar / Cummins / Crompton Greaves.
Supply and fixing in repairs of AVR for DG set having capacity upto 250 KVA to 400 KVA complete all as directed by Engr-in-Charge. Make :- Natonal / Kirloskar / Cummins / Crompton Greaves.
Supply and fixing in repairs water temperature sensor unit for DG set complete all as directed by Engineer-in-Charge. Make :- Ashok Leyland / Kirloskar / Cummins.
Supply and fixing in repairs for all type of hose pipe, over flow pipe, copper tube fuel supply pipe, etc with clip complete all as directed by Engineer-in-Charge.
Supply and fixing in repairs 12 Volt 180 AH capicity Battery Complete all as specified and directed by the Engineer-in-Charge. Make : Exide / Amaron / Luminous / Microtex / Amco / Okaya
Supply and fixing in repairs 12 Volt 150 AH capicity Battery Complete all as specified and directed by the Engineer-in-Charge. Make : Exide / Amaron / Luminous / Microtex / Amco / Okaya
Supply and fixing in repairs 12 Volt 100 AH capicity Battery Complete all as specified and directed by the Engineer-in-Charge. Make : Exide / Amaron / Luminous / Microtex / Amco / Okaya
Supply and fixing in repairs MCCB 400 Amp 4 pole 415 Volts Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / Havells / GE / Siemens /Schneider.
Supply and fixing in repairs MCCB 250 Amp 4 pole 415 Volts Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / Havells / GE / Siemens /Schneider.
Supply and fixing in repairs MCCB 200 Amp 4 pole 415 Volts Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / Havells / GE / Siemens /Schneider.
Supply and fixing in repairs MCCB 160 Amp 4 pole 415 Volts Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / Havells / GE / Siemens /Schneider.
Supply and fixing in repairs MCCB 125 Amp 4 pole 415 Volts Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / Havells / GE / Siemens /Schneider.
Supply and fixing in repairs MCCB 100 Amp 4 pole 415 Volts Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / Havells / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor, 100 Amps , 240 AC, 2 NO+NC or 01 NO + NC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor, 200 Amps, 240 AC, 2 NO+NC or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor, 160 Amps, 240 AC, 2 NO+NC or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor, 250 Amps, 240 AC, 2 NO+NC or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor, 300 Amps, 240 AC, 2 NO+NC or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor, 400 Amps, 240 AC, 2 NO+NC or 01 NO NC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor coil,100 Amps, 240 volts AC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor coil,200 Amps, 240 volts AC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor coil,160 Amps, 240 volts AC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor coil, 400 Amps, 240 volts AC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor coil, 250 Amps, 240 volts AC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs Four Pole Contactor coil, 600 Amps, 240 volts AC Complete all as specified and directed by the Engineer-in-Charge. Make :Legrand / L&T/ ABB / TC / GE / Siemens /Schneider.
Supply & Fixing in repairs of Autocut Electrical Battery Charger Unit SMPS 12 Volt , DC , 10 Amps with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc. complete all as directed by the Engineer in Charge. Make : Teknika/ NPP /Okaya / Microtex / Sukam / Amco
Supply & Fixing in repairs of Autocut Electrical Battery Charger Unit SMPS 24 Volt , DC , 10 Amps with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc. complete all as directed by the Engineer in Charge. Make : Teknika/ NPP /Okaya / Microtex / Sukam / Amco
Supply & Fixing in repairs of Voltage Monitor Relay, 3 Phase AC, 110/415V AC Setting 75-100/300-400V, Trip Time 0-10 Sec complete all as directed by the Engineer in Charge. Make : Teknika/ L&T /Vinilec
Supply & Fixing in repairs indicating lamp set RYB for phase indication operating 240 volts 50 HZ AC with new one LED panel mounting type complete to match existing one complete all as directed by the Engineer in Charge. Make : L&T / C&S / Siemens / ABB / GE /Legrand
Supply & Fixing in repairs of Timer AC/DC on Delay, AC 110/220VAC DC 24, 1-10, 3-30, 10-100 Sec omplete all as directed by the Engineer in Charge. Make : L&T / C&S / Siemens / ABB / GE / Legrand
Supply & Fixing in repairs Engine Start Relay, 12 VDC, For Gensets 3 Cranks No & Off 0-30 Sec Each Setable omplete all as directed by the Engineer in Charge. Make : L&T / Teknika / Vinilec
Supply & Fixing in repairs Engine Start Relay, 24 VDC, For Gensets 3 Cranks No & Off 0-30 Sec Each Setable complete all as directed by the Engineer in Charge. Make : L&T / Teknika / Vinilec
Supply & Fixing in repairs Earth Fault Relay, Non Direction, Defite Time & Current adustable Setting 0.4-4A/0.2-2A, Time 0-10 Sec complete all as directed by the Engineer in Charge. Make : L&T / Teknika / Vinilec
Supply & Fixing in repairs Annunciator Units, Four Fault, 12/24V DC complete all as directed by the Engineer in Charge. Make : L&T / Teknika / Vinilec
Supply & Fixing in repairs DC Ammeter 96 Sqmm, Analog, 0-20 Amp complete all as specified & directed by the Engineer in Charge. Make : Legrand / L&T/ ABB / AE / GE / Siemens
Supply & Fixing in repairs DC Ammeter 96 Sqmm, Analog, 0-30 Amp complete all as specified & directed by the Engineer in Charge. Make : Legrand / L&T/ ABB / AE / GE / Siemens
Supply & Fixing in repairs 6 x1.5 Sqmm Multistrand Copper Conductor Control Cable for DG Set to AMF Panel complete all as specified & directed by the Engineer in Charge.
Supply & Fixing in repairs of Single Phase Preventer in AMF Panel complete all as specified & directed by the Engineer in Charge. Make : Legrand / L&T/ ABB / AE / GE / Siemens
Supply & Fixing in repair of DC 12V Solenoid suitable for DG Set complete all as specified & directed by the Engineer in Charge. Make : Legrand / L&T/ ABB / AE / GE / Siemens /CG
Supply & fixing in repairs of Microprocessor/Alfa-Numeric Based DG Set PLC for DG Set (PS 600 unit for Cummins) AMF Panel of DG Set complete all as specified and directed by the Engr-in-Charge.
Supply & fixing in repairs of Microprocessor/Alfa-Numeric Based DG Set PLC for DG Set of make as existing at site (for Crompton Greaves Engine Sets / Ashok leyland /Crompton Greaves) complete all as specified and directed by the Engr-in-Charge.
Supply & fixing in repairs of Microprocessor/Alfa-Numeric Based DG Set PLC for DG Set (for V1/V2 unit for Kirloskar Engine Sets) complete all as specified and directed by the Engr-in-Charge.
Supply & fixing in repairs of Microprocessor/Alfa-Numeric Based DG Set PLC for DG Set (PLC for Mahindra DG Sets) complete all as specified and directed by the Engr-in-Charge.
Supply & Fixing in repairs of Thermostate, suitable for DG Set. Complete all as specified and directed by the Engr-in-Charge.
Material & labour repair/overhauling of self starter IC of capacity 12 Volts (Make Lucas) of DG set, including replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc and warnishing complete all as directed by the Engineer in Charge.
Material & labour repair/overhauling of self starter IC of capacity 24 Volts (Make Lucas) of DG set, including replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc and warnishing complete all as directed by the Engineer in Charge.
Supply & Fixing in repairs of Oil pressure switch of DG set complete all as directed by the Engineer in Charge.
Supply & Fixing in repairs of Starter ring mounted on fly wheel of DG set complete all as directed by the Engineer in Charge.
Supply & Fixing in repairs of brass Battery terminal of DG set complete all as directed by the Engineer in Charge.
Supply & Fixing in repairs of Battery led of DG set complete all as directed by the Engineer in Charge.
Supply & Fixing in repairs of Fan Belt of DG set complete all as directed by the Engineer in Charge.
Supply & Fixing in repairs of Speed governor probe of DG set complete all as directed by the Engineer in Charge.
Material & Labour for opening of AMF Panel, Cleaning of dust using blower & cleaning agents. Checking/Detecting of faults,removal of old wiring, removal of Faults & Re-wiring of Panel with new wires as per existing & Testing of Control Wiring complete as reqd and closing of AMF Panel after replacement of above u/s parts and testing on completion of job on existing load,cleaning and removing the sludge from DG set etc complete all as specified & directed by Engineer-in-Charge.
Supply & fixing in repairs of AMF Controller (PROCOM UNIT) for AMF Panel for 12V and 24 V both supply complete all as specified & directed by Engineer-in-Charge.
Supply & fixing in repair Auxiliary Relay 14/11/8 Pin 230V AC, suitable for AMF Panel of DG Set complete all as specified & directed by Engineer-in-Charge. Make = OEN / L&T
Supply & fixing in repair Auxiliary Relay 14/11/8 Pin 12/24V DC, suitable for AMF Panel of DG Set complete all as specified & directed by Engineer-in-Charge. Make = OEN / L&T
Supply & Fixing in repair of DC 12V fuel Solenoid Coil left/right suitable for DG Set complete all as specified & directed by the Engineer in Charge.
Supply & Fixing in repair of DC 24V fuel Solenoid Coil left/right suitable for DG Set complete all as specified & directed by the Engineer in Charge. Make- Kirloskar, Mahindra, CG , Ashok Leyland & Cummins
Supply & Fixing in repair of ELECTRONIC FUEL PUMP including calliberation suitable for DG Set complete all as specified & directed by the Engineer in Charge. Make- Kirloskar, Mahindra, CG , Ashok Leyland & Cummins
Replacement of relay card used for AMF panel complete all as specified & directed by the Engineer in Charge.
Supply & Fixing in repairs of DC 12/24 self fuel Solenoid Coil suitable for DG Set complete all as specified & directed by the Engineer in Charge. Make- Kirloskar, Mahindra, CG , Ashok Leyland & Cummins
Supply and filling in and top up of battery distilled water used for lead acid battery as directed by Engineer-in-Charge.
Achal Sales
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .