Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.2 L+₹3.0 L (21.1%)Rejected-AOC 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹17.9 L+₹3.7 L (25.8%)Rejected-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹18.2 L+₹3.9 L (27.8%)Rejected-AOC SHAMAL BECHAR S CHAWL SIDHANATH ROAD B H KHANDERAO MARKET VADODARA 390 001 GUJARAT | VADODARA | VADODARA | GUJARAT | 390001 | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹18.8 L+₹4.6 L (32.5%)Rejected-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
23 Jun 2022, 6:00 pmClosed
Sachin Singhal EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2022_MES_526791_1
8659
Open Tender
Civil Works
Item Rate
270 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹40,000
Yes
15 Jul 2022
27 May 2022
28 Jun 2022
27 May 2022
23 Jun 2022
11 Jun 2022
28 May 2022 - 10 Jun 2022
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, in roof kerb etc
M&L for Cement concrete type B1 1:2:4 (20 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges.
Taking down cement plaster on brick/concrete surface including raking out joints hacking for key, scrubbing down with water etc.
M&L for Rendering 15 mm thick in two layer, on fair faces of brick work or concrete surfaces of wall 5 mm thick in CM 1:4 mixed with WPC @ 3% by wt of cement, finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately).
Supply only Integral water proofing compound all as specified and directed.
M & L for preparing new plastered surfaces of wall and applying two coats cement base paint over a coat of alkali resistant primer on external wall.
Disconnecting existing tanks, up to 500 ltrs, setting aside, lowering if required, and refixing (hoisting if required) in position after necessary petty repair and cleaning all as directed by Engr -in charge
Disconnecting existing tanks, 1000 ltrs setting aside, lowering if required, and refixing (hoisting if required) in position after necessary petty repair and cleaning all as directed by Engr -in charge
Taking up or down steel tubing and connections, 20mm bore including cleaning for refixing or removal to store
Taking up or down steel tubing and connections, 25mm bore including cleaning for refixing or removal to store
Refixing 20mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) with all fittings.
Refixing 25mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) with all fittings.
S&F 20mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
S&F 25mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
S&F 20mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S&F for 25mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
Complete removal of existing water proofing treatment APP membrane including cement plaster and cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
Complete removal of existing water proofing treatment APP membrane including plaster and concrete padding below, roughening of concrete roof surface, cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
Complete removal of existing water proofing treatment APP membrane including PCC tiles above, and plaster and concrete padding below, roughening of concrete roof surface, cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
M&L for 50 mm average thick PCC padding in cement concrete type B0 (1:2:4) using 12.5 mm graded stone aggregate mixed with WPC @ 2% by wt of cement over roof surface all as specified and directed. (WPC will be measured and paid separately).
M&L for 10mm thick rendering in CM 1:3 mixed with WPC @ 3% by wt of cement finished even and smooth without using extra cement over roof surface for laying APP membrane on roof (WPC will be measured and paid separately).
M&L for water Proofing treatment to roof slabs by applying one coat of bituminous/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm, and laying atactic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minimuum 3 Kg/Sqm, 3 mm thick (minimum) with minimum 75 mm side overlaps and minimum 100 mm end overlaps and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete all as specified and directed by Engr-In-Charge
M&L for water Proofing treatment to roof slabs by applying one coat of bituminous/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm, and laying atactic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minium 3 Kg/Sqm, 3 mm thick (minimum) with minimum 75 mm side overlaps and minium 100 mm end overlaps complete all as specified and directed by Engr-In-Charge
M&L for water Proofing treatment to roof slabs by applying one coat of bituminous/polymerized primer confirming to IS-3384 @ 0.25 Ltrs/Sqm, and laying self adhesive water proofing membrane 1.5 mm thick with minimum 75 mm side overlaps and minimum 100 mm end overlaps and applying one coat of aluminium paint @ 0.11 Kg/Sqm over membrane complete all as specified and directed by Engr-In-Charge
M & L for brushing with neat cement slurry @ 3Kg/Sqm
M & L for Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry with WPC @ 3% by wt of cement in floors/roof top laid over and including 20 mm thick cement screed in CM 1:6 complete all as specified and directed (WPC will be measured and paid separately).
Cutting grooves in brick parapet wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 for sealing APP membrane in brick parapet wall complete all as specified and directed.
S&F in repairs 25mm thick pre-formed filler for expansion/ crumple joints of roof slab.
Supply and fix Plain 0.71mm thick, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)
Taking down PVC/CI pipe of any pattern /size including all fittings etc. and cleaning for refixing or removal outside MD land
S&F 110mm dia PVC SWR pipe single socketed in any length with rubber ring joints fixed to walls
S & F in repairs 110mm dia PVC SWR bend with oval access door
S & F in repairs 110mm dia PVC SWR bend without oval access door
S&F in repairs 25mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
Disconnecting existing water tank of capacity exceeding 500 ltr but exceeding not 1000 ltr and S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 ltrs capacity, hoisted and fixed in position all as specified in SSR Part I
Disconnecting existing water tank of capacity exceeding 250 ltr but not exceeding 500 ltr and S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 ltrs capacity, hoisted and fixed in position all as specified in SSR Part I
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc,
M&L for Brick work with sub class ‘B’ old size bricks straight or curved on plan exc 6 m mean radius built in CM 1:6
M&L for 100 mm thick PCC 1:4:8 ,type D-2, using 40 mm graded stone aggregate as in tank staging complete all as specified & directed.
Chanda Construction Co.
Dagli Engineers
M/s. RAMESH NARHARI VALEKAR
Badri Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .