Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC BAMAN PARA SRIRAM PARA MANDALGHAT DIST JALPAIGURI PIN 735132 | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735132 | ₹14.3 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹14.3 L+₹1,144.71 (0.08%)Rejected-AOC P O DHAPGANJ TOROLPARA DIST JALPAIGURI | JALPAIGURI | WEST BENGAL | ₹14.3 L+₹1,144.71 (0.08%) | L2 | Rejected-AOC High Rate |
Tender Value
₹14.3 L
EMD Value
₹28,620
Closing Date
14 Aug 2026, 3:00 pmClosed
General Manager
23B NetajiSubhas Road 3rd Floor Kolkata 700 001
Solar High Mast Lights
2026_WBAIC_1035590_1
AIC/AED/NIeT-132(2nd Call)/26-27
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
60 days
Jalpaiguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,180
₹28,620
Yes
West Bengal Agro Industries Corporation Limited
8 Sept 2026
31 Jul 2026
17 Aug 2026
31 Jul 2026
14 Aug 2026
1 Aug 2026
7 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of 10.5 mtr Ocatagonal GI Pole of approved make with hot dip Galvanized inside & outside, having pole shect thickness 3mm, top dia minimum 150 mm, bottom dia minimum 360 mm, base plate 500 mm x 500 mm x l6 mm, suitable for wind velocity as per IS 875 part 3 & having no circumſerential weld, with accessorics for high mast such as head framc suitable for 6 nos Solar Iuminaries, 6 nos Solar panels, arrangement of winch with hand pulley system with suitable metalic rope/ metalic ladder for maintanance purposc &6 nos
Foundation Bolt 24Amm x 600mm. | 4 | No | 64,000 | ₹2,56,000 |
| 2 | Construction of RCC shallow foundation with base footing for erection of High Mast Tower by carth work in cxcavation of foundation trench approx zonc 1.2m X 1.2m X 1.Sm including removing spoils and neccssary trcaming the site of trench leveling, dressing and the bottom, bailling out water soil testing ctc. after that pickcd jhama bricks solling and dressing bed leveling and illing joints after that distribution 10mm TATA tor rod, proper size stirrups, binder ctc. and vertically MS tor rod 12 mm dia foundation not lcss than 8 nos. and levelling rod by 8 mm dia tor @I50 mm c/c spacing apart including binding with 16 SWG black anncals wire steel shurering and placement of not less than 5 nos (53 mm dia X 1200 mm Long) Foundation bolt with anchor plate of strength and ready mix concrete of M25 grade with graded stone chips 20 mm as per IS:10262 and IS: 456 (proportion 1:1:2) complete and water regidity next 7 days considering the safe soil bearing capacity of 10T/sqm. | 4 | No | 35,000 | ₹1,40,000 |
| 3 | Supply of Monocristaline solar panel with the following major specifications:
Capacity: 12V 200Wr, Rated Power (Pmax)-[W]200.00, Raled Voltage (Vmax) - [v) 19.80, Rated Current (Imax)-(A) 114, Open Circuit Voltage (Voc) - [V]) 23.40, Short Circuit Current (Isc)-[AJ 12.05, Minimum Module ETiciency (0)- [S) 19. The SPV module shall be highle reliable, lightweight and shall have service life more than 25 years, the module shall have a limited power loss of not more than 10% of nominal output at the cnd of 10 years and not more than 20h at the end of 25 years.
Environment Withstand Ability: The solar module shall be able to withstand the temperature extremes ranging from 40°C to +85°C and the wind load af wind speed a 1sOknhr. Maximem mean hour rainfall of 40mm, Humidity level up to 90%. Framing: The panel made up with h heficient cells should be made up robust anodized aluminium frame with m nting frame (M.S. may be required) with mounting holes, The strip must cont uin the following details-) Name of the manufacturer b) Model no, or Typc no. ) Serial no. d) Year of manufacturing etc.
Make- BIS/ MNRE Approved | 24 | Nos | 7,000 | ₹1,68,000 |
| 4 | Supply & Delivery of 50W DC LED with minimum colour temperature (CC) 5500-6500K minimum typical luminous lux 150 LmW, i.c. minimum 3600 LM (Philips Osram equivalent reputed make with DIS certificate) having dic cast aluminium body with in-built Charge Controller & Driver suitable for Lithium Ferro Phosphate Battery with MPPT and eficiency > 929% and should have Battery over charge cut-of, Deep Discharge cut-olf, Short Circuit protection, Protection against Reverse Polarity, Load reconnect, Over heating. Automatic dusk to dawn controlling facilities & Dimmer arTangement are inbullt with the system. | 24 | Nos | 4,000 | ₹96,000 |
| 5 | Supply of 12.8 V 100 AH Lithium Ferro Phosphate Battery (LiFePO4) having BIS Certificate having Battery Management System (BMS) with higher life expectancy, longer cycle life, low discharge rate& fast charging facilities. Battery should provide 12 hours backup. Battery must be provided with GI Battery box/inbuilt in luminaries arrangement. | 24 | Nos. | 20,000 | ₹4,80,000 |
| 6 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts, below the ground level & restoring surface duly rammed. | 4 | Nos. | 4,500 | ₹18,000 |
| 7 | Cables and wires
a) DC Cable 4 sqmm
b) Control Cable - LS | 4 | LS | 800 | ₹3,200 |
| 8 | Installation and Commissioning | 4 | LS | 2,500 | ₹10,000 |
| 9 | Transportation | 4 | LS | 2,000 | ₹8,000 |
| 10 | Comprehensive maintenance for 05 years | 4 | LS | 5,000 | ₹20,000 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.01 MB
Tendernotice_2.pdf
PDF • 1.11 MB
Tendernotice_3.pdf
PDF • 0.60 MB
BOQ_2543844.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .