Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹39.3 LAccepted-AOC | L-1 | Accepted-AOC Being L1 | |
| 2 | L-2₹41.6 L+₹1.2 L (2.89%)Rejected-Finance | L-2 | Rejected-Finance Being other than L1 | |
| 3 | L-3₹42.0 L+₹1.5 L (3.78%)Rejected-Finance | L-3 | Rejected-Finance Being other than L1 | |
| 4 | L-4₹42.0 L+₹1.5 L (3.82%)Rejected-Finance P O BINNAGURI 735203 DISTT JALPAIGURI W B | JALPAIGURI | WEST BENGAL | 735203 | L-4 | Rejected-Finance Being other than L1 | |
| 5 | L-5₹42.1 L+₹1.6 L (4.00%)Rejected-Finance | L-5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | M/S PAWAN ENTERPRISE L2 | Tirupati Construction L3 | BBKundu L4 | SS SHARMA L9 | M/S SHIVNATH SINGH L7 | M/s. RAMPHAL GARG L5 | MESSRS SEN BROTHERS L8 | M/S SINHA ENTERPRISE L6 | M/S S.K.DAS L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | SOLAR WATER GEYSER
Disconnecting of water connection and dismantling complete solar water heating system of capacity 300 ltrs per day including hot & cold water pipes and hot water tank complete and refixing after repairing the system fixing back in position and testing complete all as specified and directed by Engineer-in-charge.
Note : Rates quoted by the contractor shall deemed to be included for :-
(a) Making good the worn out missing nuts bolts, washers, union, sockets, flanges and screws etc.
(b) Descaling/ desludging, cleaning and washing of the solar panel, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and re-assembling the panel including welding of collector fins as required.
(c) Painting of staging, solar panel frame, hot water tank frame with applying one coat of synthetic enamel paint incl preparation of old painted steel surfaces of any description
(e) All other materials shall be measured and paid separately under respective items. | 28 | Each Job | 630 ₹17,640 | 680 ₹19,040 | 579 ₹16,212 | 621 ₹17,388 | 550 ₹15,400 | 530 ₹14,840 Lowest | 700 ₹19,600 | 605 ₹16,940 | 540 ₹15,120 |
| 2.00 | All as per items No 01 here in before but of capacity 200 ltrs per day complete all as specified and directed by Engineer-in-charge. | 40 | Each Job | 540 ₹21,600 | 440 ₹17,600 Lowest | 579 ₹23,160 | 462 ₹18,480 | 480 ₹19,200 | 450 ₹18,000 | 500 ₹20,000 | 470 ₹18,800 | 445 ₹17,800 |
| 3.00 | All as per items No 01 here in before but of capacity 100 ltrs per day complete all as specified and directed by Engineer-in-charge. | 50 | Each Job | 350 ₹17,500 | 380 ₹19,000 | 299 ₹14,950 Lowest | 346 ₹17,300 | 400 ₹20,000 | 415 ₹20,750 | 346 ₹17,300 | 355 ₹17,750 | 347 ₹17,350 |
| 4.00 | Supplying only as in replacement, copper tubes with collectors fins for solar energy collector panel complete of same dia and thickness as per existing, brazing by copper alloy brazing rod with the existing inlet/outlet hot/cold water pipes to make the panel water tight complete all as specified by Engineer-in-charge. | 33 | Each Panel | 2,032 ₹67,056 | 2,010 ₹66,330 | 2,079 ₹68,607 | 2,012 ₹66,396 | 2,020 ₹66,660 | 2,015 ₹66,495 | 2,050 ₹67,650 | 2,025 ₹66,825 | 2,000 ₹66,000 Lowest |
| 5.00 | Supply only compressed glass wool 48 mm thick between solar energy collector panel copper tubes frame and aluminum body panel including securing it on panel by means of necessary adhesives all as directed all as specified and directed by Engineer-in-charge. | 24 | Per Sqm | 155 ₹3,720 | 150 ₹3,600 | 19 ₹456 Lowest | 162 ₹3,888 | 158 ₹3,792 | 162 ₹3,888 | 165 ₹3,960 | 162 ₹3,888 | 159 ₹3,816 |
| 6.00 | Supply only solar energy collector panel manifold 1.40 mtr long, made of 20mm dia copper tube having 1 No MS flange 74 mm dia welded at each end duly drilled for nuts & bolts complete all as specified and directed by Engineer-in-charge. Note : Rate quoted deemed to be included for welding of solar collector tubes with manifold all as directed by Engineer-in-charge and as recommended by manufacturer. | 28 | Each | 1,600 ₹44,800 | 1,490 ₹41,720 Lowest | 1,609 ₹45,052 | 1,532 ₹42,896 | 1,525 ₹42,700 | 1,520 ₹42,560 | 1,495 ₹41,860 | 1,625 ₹45,500 | 1,500 ₹42,000 |
| 7.00 | S&F hose pipe for hot/ cold water for solar system of suitable length as existing size complete with 02 Nos clamps all as directed by Engineer-in-charge. | 36 | Per RM | 465 ₹16,740 Lowest | 477 ₹17,172 | 529 ₹19,044 | 478 ₹17,208 | 510 ₹18,360 | 518 ₹18,648 | 477 ₹17,172 | 501 ₹18,036 | 480 ₹17,280 |
| 8.00 | Supply only auxillary tank for make up tank to reduce pressure of solar system complete as directed by Engineer-in-charge. | 24 | Each | 2,250 ₹54,000 | 2,259 ₹54,216 | 2,289 ₹54,936 | 2,246 ₹53,904 | 2,248 ₹53,952 | 2,195 ₹52,680 Lowest | 2,290 ₹54,960 | 2,272 ₹54,528 | 2,200 ₹52,800 |
| 9.00 | S&F Electrical backup heater of 2 KW for solar system with all electrical connection complete all as directed by Engineer-in-charge. | 24 | Each | 1,283 ₹30,792 | 1,245 ₹29,880 Lowest | 1,369 ₹32,856 | 1,280 ₹30,720 | 1,340 ₹32,160 | 1,360 ₹32,640 | 1,300 ₹31,200 | 1,270 ₹30,480 | 1,300 ₹31,200 |
| 10.00 | S&F Electrical backup heater of 3 KW for solar system with all electrical connection complete all as directed by Engineer-in-charge. | 36 | Each | 1,590 ₹57,240 | 1,665 ₹59,940 | 1,579 ₹56,844 Lowest | 1,680 ₹60,480 | 1,620 ₹58,320 | 1,600 ₹57,600 | 1,642 ₹59,112 | 1,682 ₹60,552 | 1,595 ₹57,420 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Nov 2025, 6:00 pmClosed
GE (North) Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
REPAIR/MAINT OF GEYSERS, SOLAR GEYSER, CEILING FAN, WALL MOUNTED FAN, EXHAUST FAN AND ALLIED WORKS AT CENTRAL AND NORTH ZONE AREA UNDER GE NORTH BINNAGURI
2025_MES_734736_1
8701 / 61 / 2025-26 / 09 / E8
Open Tender
Civil Works
Item Rate
270 days
Binnaguri cantonment
D Class Category b (i)
8 documents required · 8 mandatory
₹500
GE (North) Binnaguri
₹80,000
Yes
22 Dec 2025
11 Oct 2025
8 Nov 2025
11 Oct 2025
6 Nov 2025
29 Oct 2025
Amount
SOLAR WATER GEYSER Disconnecting of water connection and dismantling complete solar water heating system of capacity 300 ltrs per day including hot & cold water pipes and hot water tank complete and refixing after repairing the system fixing back in position and testing complete all as specified and directed by Engineer-in-charge. Note : Rates quoted by the contractor shall deemed to be included for :- (a) Making good the worn out missing nuts bolts, washers, union, sockets, flanges and screws etc. (b) Descaling/ desludging, cleaning and washing of the solar panel, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and re-assembling the panel including welding of collector fins as required. (c) Painting of staging, solar panel frame, hot water tank frame with applying one coat of synthetic enamel paint incl preparation of old painted steel surfaces of any description (e) All other materials shall be measured and paid separately under respective items.
All as per items No 01 here in before but of capacity 200 ltrs per day complete all as specified and directed by Engineer-in-charge.
All as per items No 01 here in before but of capacity 100 ltrs per day complete all as specified and directed by Engineer-in-charge.
Supplying only as in replacement, copper tubes with collectors fins for solar energy collector panel complete of same dia and thickness as per existing, brazing by copper alloy brazing rod with the existing inlet/outlet hot/cold water pipes to make the panel water tight complete all as specified by Engineer-in-charge.
Supply only compressed glass wool 48 mm thick between solar energy collector panel copper tubes frame and aluminum body panel including securing it on panel by means of necessary adhesives all as directed all as specified and directed by Engineer-in-charge.
Supply only solar energy collector panel manifold 1.40 mtr long, made of 20mm dia copper tube having 1 No MS flange 74 mm dia welded at each end duly drilled for nuts & bolts complete all as specified and directed by Engineer-in-charge. Note : Rate quoted deemed to be included for welding of solar collector tubes with manifold all as directed by Engineer-in-charge and as recommended by manufacturer.
S&F hose pipe for hot/ cold water for solar system of suitable length as existing size complete with 02 Nos clamps all as directed by Engineer-in-charge.
Supply only auxillary tank for make up tank to reduce pressure of solar system complete as directed by Engineer-in-charge.
S&F Electrical backup heater of 2 KW for solar system with all electrical connection complete all as directed by Engineer-in-charge.
S&F Electrical backup heater of 3 KW for solar system with all electrical connection complete all as directed by Engineer-in-charge.
Descaling solar energy collector panel made of aluminium body with toughened glass complete with copper fins of capacity 100/200/300 ltrs per day complete all as specified and directed by Engineer-in-charge.
Descaling of hot water storage tank of food grade stainless steel 100 ltr capacity complete all as specified and directed by Engineer-in-charge.
Descaling of hot water storage tank of food grade stainless steel 200 ltr capacity complete all as specified and directed by Engineer-in-charge.
Descaling of hot water storage tank of food grade stainless steel 300 ltr capacity complete all as specified and directed by Engineer-in-charge.
M&L for insulation of hot water pipe with glass wool and covering with aluminium sheet cladding 25 gauge for 20mm bore GI pipe complete all as specified and directed by Engineer-in-charge.
S & F in repair ball brass valve 20mm bore dia high pressure with polythene float and fly nuts complete screwed with iron pipe and fixed all as specified and directed by Engineer - in - Charge .
S & F in repairs gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipes 20mm bore as in repairs complete all as specified and directed by Engineer – in – Charge.
S & F in repairs gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore as in repairs complete all as specified and directed by Engineer – in – Charge.
S & F in repairs glass wool insulation with aluminium cladding for 25 mm bore pipe all as specified and directed by Engineer – in – Charge.
GEYSER (a) Taking down the existing unsv storage type electric water heater (geyser)of any make/ capacity, installed at different location including dis-connecting, taking down opening all parts/accessories for inspection, cleaning, descaling, refixing serviceable parts, replacing unserviceable parts installed at old location and reconnection, testing complete all as directed by Engineer-in-Charge for the following capacity :- 25 Ltr capacity
(b) 35 Ltr capacity
( c) 50 Ltr capacity Note :- (a) The rates of item No 1 above deemed to include the labour charges for fixing of new parts as required .The new parts required shall be paid as supply only under item No 11 to 24 here in after. (b) Serviceable materials obtained from item No 1 above shall be refixed and labour charges for the same are included in unit rate of Item No 1 above. (c ) Other item shall be paid as mentioned here in after.
Supply only heating element round type of geysers including rubber washer for the following capacity (Make : Recold/Bajaj) :- (a) 1500 Watt capacity
(b) 2000 Watt capacity
Supply only PVC connection pipe with brass unions at both ends, 450mm long 15mm bore (for incoming cold water) all as specified and as directed.
Supply only chromium plated copper connection pipe 450mm long with two brass adopters washers and connecting up complete all as specified and directed.
Supply only apparatus plate suitable for 25 ltrs capacity geyser.(Make : Bajaj/Recold)
Supply only apparatus plate suitable for 35 ltrs capacity geyser
Supply only apparatus plate suitable for 50 ltrs capacity geyser
Supply only thermostat (ISI Marked) for 25/35/50 Liters capacity Geyser.(Make: Elcon, USHA or Equivalent ISI marked)
Supply only thermostat (ISI Marked) for 25/50 Liters capacity Geyser for Racold geysers
Supply only steel tanks 25 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 25 Liters capacity Geysers and replacement of rubber packaging ring heat resistant type all as directed by Engineer -in - charge.
Supply only steel tanks 35 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 35 Liters capacity Geysers and replacement of rubber packaging ring heat resistant type all as directed by Engineer -in - charge.
Supply only steel tanks 50 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 50 Liters capacity Geysers and replacement of rubber packaging ring heat resistant type all as directed by Engineer -in - charge.
Supply & Fixing Plug top, 3 pin, 15 amps, 230 volt, including electric connection after taking out old unserviceable one complete all as specified and directed.
S&F stop valve, ISI marked, brass, 15mm bore after taking out defective/ unserviceable one complete all as specified and directed
M&L for concealed sub main wiring with 3 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. NOTE : (i) Three run of sub main wiring cable along with 20mm PVC conduit pipe shall be measured as one unit length.
M&L for sheet metal enclosure MCB distribution board, 2 way single door 230 volts all as specified and as directed.
S&F in replacement safety nut for pressure release valve (As per sample) complete all as specified.
S&F in replacement hole fastener 10 mm dia, 100 mm long including nut and washer complete all as specified.
S&F non return valve all as specified and directed
S&F in replacement rubber gas Kit suitable for 50/25 ltrs capacity geyser (as per sample) complete all as specified.
M&L for fixing of new/old geysers at new place with hole fastener and cement work including connection with existing pipes complete all as directed by Enge-in-charge
FANS Taking down ceiling fan any size from its location including disconnecting from ceiling rose, after removing carefully false ceiling/ ceiling wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosene oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and bottom cover in position; washing body, blades, canopies with detergent soap powder; preparation of old painted surfaces by filling cavities with suitable filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re - hanging fan and false ceiling in position and making electric connection complete all as directed. (Spare wherever required to be renewed shall be measured and paid vide under respective item supply only).
Material and labour for removing the defective/burnt ceiling fans winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape, cloth and sleeves, varnishing and drying, greasing and making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brought at site complete. Note: (i) Winding shall be carried out by winding machine.
Taking down exhaust fan 300/380/450 sweep of any size from its location including disconnecting from ceiling rose, after removing carefully wall wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosene oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and covers in position; washing body, blades, with detergent soap powder; preparation of old painted surfaces by filling cavities with suitable filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and refixing fan to wall in position and making electric connection complete all as directed. (Spare wherever required to be renewed shall be measured and paid vide under respective item supply only).
Material and labour for removing the defective/burnt Exhaust fans of sweep 380/450 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape,cloth and sleeves, varnishing and drying, greasing and making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brought at site complete. Note: (i) Winding shall be carried out by winding machine.
Material and labour for removing the defective/burnt Exhaust fans of sweep 300 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape, cloth and sleeves, varnishing and drying, greasing and making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brought at site complete. Note: (i) Winding shall be carried out by winding machine.
Taking down wall mounted / pedestal fan of 600mm sweep any size from its location including disconnecting from ceiling rose, after removing carefully false ceiling wherever necessary and removing blades, opening of fan and cleaning of bush / ball bearing with kerosene oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing, locking nut, screw, split pin, check nut, rubber real wherever required tightening of stator up and covers in position; washing body, blades, with detergent soap powder; preparation of old painted surfaces by filling cavities with suitable filler and applying one coat of spray painting to fan (white or any other approved shade) and writing MES No. etc ,testing and re - hanging fan and false ceiling in position and making electric connection complete all as directed. (Spare wherever required to be renewed shall be measured and paid vide under respective item supply only).
Material and labour for removing the defective/burnt pedestal fans of sweep 600 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, with required Number of turns and including all insulating material s such as insulating tape, cloth and sleeves, varnishing and drying, greasing and making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts and testing and brought at site complete. Note: (i) Winding shall be carried out by winding machine.
S&F in replacement of ball bearings No 6201,6202,6203, 6204 or any other size required for old vintage ceiling fans / exhaust fans/ pedestal fans Make: SKF / NBC
S&F in replacement of bronze bush of suitable size for ceiling fans of any size and make including greasing with approved quality of grease all as directed and as specified.
S&F in replacement of capacitor 2.5/4.0 mfd for ceiling fan complete all as directed and as specified.
S&F in replacement of capacitor 4.0 mfd for ceiling fan complete all as directed and as specified.
S & F Fan shaft ( as sample ) suitable for motor of ceiling fan 1200/1400 mm sweep complete all as directed and as specified
S&F in replacement of PVC connector block 4 way with fixing nuts and clamps all as directed.
M&L for Painting of ceiling fans including blades with applying two coats of synthetic enameled paint over a coat of red oxide primer by using spray painting machine on old prepared surface including writing of MES No using synthetic enamel paint black colour complete all as specified and as directed.
Supply and fixing upper canopy and down canopy for ceiling fans suitable for any make and sweep all as specified and as directed.
Supply and fixing in repair hanging clamp suitable for ceiling fans of any make and type with rubber real, nuts, bolts and washers of suitable size including locking pin complete all as specified and as directed.
S&F in replacement of Metal Fan blade suitable for Ceiling Fan 1200 mm sweep complete all as specified and as directed.
S&F in replacement of Metal Fan blade suitable up to 300 mm sweep Exhaust fan (As per existing sample) complete all as specified and as directed.
S & F in replacement of PCB Card for BLDC Remote Fan(Energy efficient) of make Havells, Orient & Bajaj complete all as specified and as directed.
M/S PAWAN ENTERPRISE (BID ID -3465811)
Tirupati Construction (BID ID -3466233)
BBKundu (BID ID -3467354)
M/s. RAMPHAL GARG (BID ID -3468121)
M/S SINHA ENTERPRISE (BID ID -3468021)
M/S SHIVNATH SINGH (BID ID -3468912)
MESSRS SEN BROTHERS (BID ID -3468498)
SS SHARMA (BID ID -3468754)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Sch.pdf
Additional Documents • 0.38 MB
Tender.pdf
Tender Documents • 1.41 MB
BOQ_822718.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .