Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Being Lowest and reasonable | |
| 2 | L2₹38.2 L+₹64,450.70 (1.71%)Rejected-AOC DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹38.9 L+₹1.3 L (3.58%)Rejected-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹40.3 L+₹2.7 L (7.25%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹42.1 L+₹4.4 L (11.8%)Rejected-AOC M S SRI JAYANTH ASSOCIATES D NO 50 121 18 1 FLAT NO GROUND B SIVA SADAN APARTMENTS BS LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
9 Dec 2023, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
ADDITIONS and ALTERATIONS TO BUILDING NO P 01 AT WALTAIR ROAD UNDER GE ND VISAKHAPATNAM AND SPECIAL REPAIR TO RCC PLATFORMS AND METAL BASE SUPPORT FOR SALUTING GUNS AT NCB VISAKHAPATNAM
2023_MES_628050_1
8310/E8
Open Tender
Civil Works
Item Rate
240 days
VISAKHAPATNAM
As per Tender
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹82,000
Yes
25 Jan 2024
17 Nov 2023
11 Dec 2023
17 Nov 2023
9 Dec 2023
1 Dec 2023
Amount
Schedule 'A' Part -I ( B/R Schedule)
Dismantling of floor hearth or wall tiling of any description including cement mortar bedding (but not backing),removing serviceable tiles to store & rubbish off the premises
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish as directed by the Engineer in Charge.
M & L for 25 mm thick PCC (1:2:4), type B1 (Using 20 mm graded stone aggregate) as in flooring, rough finish surfaces for receving top layer.
M/L for Double Charged/ Ultra charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry & pointed in white or coloured cement including screed bed 15mm thick in cement mortar 1:4 for laying floor finishes all as specified and as directed by Engr-in-charge .
M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding. 0.11 sqm, in floors etc. set and jointed in neat cement slurry over and including a 15 mm thick screed bed of cement mortar (1:4) and pointed with white or Coloured cement to match.
M & L for Coloured Glazed ceramic design tiles 350x 250x 7mm/ 450X 350X 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 10 mm thick rendering in cement morter (1:4)
M&L granite (of any type) tiles 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over screed bed 15mm thick in cement mortar 1:4 for laying floor finishes all as specified and directed .
M&L for Granite slab, Jet Black, 20 mm thick machine cut, pre-polished , in skirting / dado and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite as in lining over including backing coat or bedding layer, 12 mm thick in Cement Mortar 1:3 up complete all as specified and directed.
M&L Chequred cement concrete tiles 20 cm x 20 cm x25 mm thick set , jointed and pointed in neat cement slury all as specified and directed.
Complete removal of existing treatment over wall / ceiling surfaces applying Wall Care Putty of make JK / Birla / Jenson & Nicholson / Altec on internal walls upto clear undulence including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of plastic emulsion paint over one coat of primer complete all as specified and as directed.
Removal existing treatment and their roughening surfaces of old concrete floor or concrete surfaces by picking,sweeping clean and washing sown with water to remove dust etc
Brushing neat cement slurry with 3 kg of cement per square metre .
Rendering 10 mm thick on concrete surfaces in cement mortar 1:4 mixed with WPC as directed and finished even and smooth to receive water proof treatment above 8 th storey upto 2ND storey complete all as specified and directed upto 2nd floor. [NOTE: Supply only WPC shall be measured and paid separately]
APP based polymeric water proofing membrane 3 Kg/Sqm incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 0.1 ltrs/sqm followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2Kg/Sqm each at top and bottom of the membrane complete including sealing all joints by thermo fusion with minimum 10 cm overlap all as per manufacturer's instructions upto 2nd storey complete all as specified and directed.
S&F cement concrete tiles 300x300x22-25mm thick machine pressed jointed and pointed in neat cement slurry in floors and cut and polished with white cement and no pigments incl screed 15mm thick in CM 1:6 upto 4th floor.
Taking down of chowkats or frames exc 1.5 sqm but n. exc 4 sqm each (without taking off shutters from the frames) and set aside or removing from site.
Taking down of chowkats or frames not exc 1.5 sqm each with shutters (without taking off shutters from the frames) and set aside or removing from site.
Taking down shutters of any description exc 1 sqm and n. exc 2 sqm each and removing from site.
S & F of 2nd class HW plain chowkhats and framed,rebated on the solid rounded or chamfered put together with glue pinned at joints from ground floor to 3rd floor.
S&F 40 mm thick flush shuter solid core construction with particle board core and plywood face panels & both faces covered with decorative face veneers with lipping/ frame to match all as specified and directed .
S&F 35 mm thick flush shuter solid core construction with particle board core and plywood face panels & both faces covered with decorative face veneers with lipping/ frame to match all as specified and directed .
S&F 35 mm thick 2nd Class Hard wood Glazed and skelton shutters shutter open rebated and prepare to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc, size of members of shutters all as specified.
Ditto as item nos 22 above but 30 mm thick divided into square,with plain ,chamferd or rounded ,mitred and rebeated sash bars any nos .
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and width of apparture 1.40 mm and fixed width tinned stacks or gaivanised wire staples using old or new beading complete all as specified and as directed by E-in-charge including taking out old rusted wire mesh.
75mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed
S & F 150 mm Floor door stopper of Brass body and tongue, with hard drawn steel spring, fixed in floor .
S&F mild steel hold fast made out of MS flat iron for chowkats and other small articles including making shape, drilling hole etc. complete.
Cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in hold fast.
S&F 125 mm extruded brass handle fabricated type polished .
S&F 200 mm brass barrel tower bolts ,with cast or sheet barrel of extruded section.
S&F 150 mm brass barrel tower bolts ,with cast or sheet barrel of extruded section.
S&F 300 mm long brass sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts with rooled and drawn brass bolt and fixed.
S&F 100 mm cast brass with mild steel hinges fixed with stainless steel screws .
S&F 4 mm thick sheet glass ordinary quality glazing with oil putty in square n exc 0.50 sq,m in each pane.
Supply, hoisting, fixing in position and connecting incoming and outgoing pipes, 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), multilayer, complete all specified and as directed including taking down existing tank. (Make : SYNTEX/POLYCON)
Taking up or down 15mm dia steel tubing connections, including cleaning for re-fixing or removal to store.
Taking up or down 20mm dia steel tubing connections, including cleaning for re-fixing or removal to store.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sun shades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc l0cm girth in stone, concrete block and concrete slab complete all as specified and as directed.
S&F 3-layer PP-R P o l y p r o p y l e n e random copolymer)pipes 20 mm outer dia SDR 7.4 & SDR 11 UV stablised laid & concealed in walls including bends, elbows, unions etc, laid on walls for vertical stacks including chasing the wall and making good complete all as (Make: SFMC PN16/SDR7.4)/ KPT
dito as above but 25 mm dia
S & F in repairs Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-041KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified and as directed.
S & F in repairs Single Lever Basin Mixer cast copper alloy, chromium plated with central hole for WHB, Fancy type 15mm bore with 450mm long braided hose & base flange complete as per Jaquar Catalogue No. CON-167KNB or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified and as directed.
S & F in repairs Single Lever cast copper alloy, chromium plated Hot and Cold 15mm dia Wall Mixer with provision for both Hand Shower and Overhead Shower complete with 115mm long bend pipe, connecting legs & wall flange complete [excluding hand & overhead shower] as per Jaquar Catalogue No. CON-281KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine Floor complete all as specified and as directed.
S & F in repairs Health Faucet with 1 m Stainless steel flexible tube, wall hook, non return valve complete all as per Jaquar Catalogue No. ALD-563 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine Floor complete all as specified and as directed.
S & F in repairs Chromium Plated Overhead Shower, 105 mm dia with revolving joints [with body rotation] & 115mm long shower arm with rapid cleaning system complete as per Jaquar Catalogue No. OHS-1709 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine Floor complete all as specified and as directed.
S & F in repairs PVC body cabinet box mirror of size 350 mm x 450 mm x 100 mm in PTMT alloy of approved patterns and designs fixed in repairs after taking out the old cabinet complete all as specified and as directed. Make : PRAYAG Cat No. 551 or equivalent as approved by the GE
S & F in repairs PVC connection 15mm size with PTMT nuts of length of 450 mm long with brass nut connections at the ends fixed to flushing cistern/ sanitary fittings up to 11th Floor complete all as specified and as directed.
S&F in repair counter wash hand basin square / oval of make Kajariya all as specified and directed.
S&F in repair single PC - P Trap wash down water closet padestel patern size 665x370x740mm of make Kajariya including all necessary fiting all as specified and directed.
Dismantling of single layer manglore pattern or similar tiles in roofing.
M&L roof tiles , Manglore pattern , inter locking at side joint laid dry all as specified and directed.
Fixing only roof tiles , Manglore pattern , inter locking at side joint laid dry all as specified and directed.
M&L Dismantling boarding of any description, fixed in any position with nails.
M&L for Prelaminated particle board 18/19 mm thick, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work and particle board fitted with external teak wood lipping, 6mm thick fixed with nails up complete all as specified and as directed.
S&F Jaguar corner entry shower enclousers 6mm thick, 9090mm width and 1950mm hieght frosted glass sliding door to both side all as specified and directed. ( Model ENNA)
S&F Jaguar corner entry shower enclousers 6mm thick, 1012mm width and 1950mm hieght frosted glass sliding door to both side all as specified and directed.( Model ENNA)
S&F Jaguar corner entry shower enclousers 6mm thick, 1515mm width and 1950mm hieght frosted glass sliding door to both side all as specified and directed.( Model ENNA)
S&F Jaguar frosred glass partition wall pannels 1200 mm width & 2000 mm hieght in size, fix all as specified and directed.( Model ALFA)
S & F Magnet Catches with 8 mm dia steel ball and Brass Body and Striking Plate including letting in and fixed in repairs complete all as specified and as directed.
S & F 50mm dia, polished, hardwood knobs fixed with screws and in repairs complete all as specified and as directed .
M & L for preparation of new wood or wood based surfaces of any description not otherwise described, over 10 cm width or girth & applying with two coats of synthetic enamel paint over a coat of pink primer.
Excavating in trenches n.exc 1.5 m wide and n.exc 1.5m in depth, for foundation etc. or for shafts wells cesspits manholes, pier holes etc. n.exc 10 sqm in plan and getting out in soft /loose soil all as specified and as directed
Excavation over areas, n exc 1.5 m deep and getting out in harde/dense soil
Returning filling of soft/loose soil in including spreading leveling watering and well ramming in layer note exc 25cm in soil etc complete all as specified and as directed
Removing excavated material(soils) n.exc 50m and depositing where directed at a level n.exc 1.5m above the stating point complete all as specified and as directed
Surface excavation n. exc 30 cm deep & averaging 15 cm deep & getting out in soft / loose soil .
M&L for hardcore of broken stone of guage n. exc 63 mm deposited,spread and levelled in layers n. Exc 15 cm thick , water and ramed to a true surface
Demolition of PCC in floor exc 15cm thickness (below or above ground level) and removing rubbish to a distance exceeding 1.50 KM and not exceeding 5.00 KM complete all as specified and directed.
M&L for cement concrete Type C2 1:3:6 (40mm graded aggregate) in foundations, filling and mass concrete.
M&L for 100 mm cement concrete Type B-2 , 1:2:4 (40mm graded aggregate) in flooring/hard standing & finished the surfaces even and smooth with using extra cement all as specified and directed.
M&L Brick work with sub class "B" Fly ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:4 complete all as specified and as directed.
M/L for Rendering 15 mm thick in two layers on brick or stone or concrete surfaces, first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:4 finished even and smooth using extra cement complete all as specified and as directed.
M&L Preparing newly plastered wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M&L RCC(M-30 Design mix) using 20mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc.,
M&L RCC(M-30 Design mix) using 20mm graded aggregate as in Columns, pillars, piers, posts and struts etc.,
Form work to sides of concrete foundation, footings ,bases of columns, raft and raft beams, etc all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions
S&F Plates ( plain or chequered ) channels,square cut or notched (ordinary and counter sunk ) with welded attachment all as specified and directed.
S&F 16 to 20 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length exc 22.50cm not exc 30 cm long.
M/L preparation of new steel surfaces of any description over 10cm width or girth apply two coats of synthetic enamel painting over one coat of redoxide primer.
Schedule 'A' Part -II ( E/M Schedule)
M & L For Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through PVC Conduit concealed in Walls / Roofs / Floors / Ceiling etc. and Modular Type Pressed Metal Flush Box made out of 1mm thick GI Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point controlled by One Switch including taking down old unsv point wiring complete all as specified. [Note- The PVC Conduit to Concealed in wall through cutting,Chassing,Pining in making good surfacing where required and pointing in cement mortar and making good for same unit rates are inculded for same]
Description all as per item No. 83 above but for 5/6Amp switch socket out let, independent board complete all as specified
Description all as per item No. 83 above but for 5/6Amp switch socket out let,same board complete all as specified
Description all as per item No. 83 above but for 15/16Amp switch socket out let, independent with 4.0sqmm copper cable of PVC insulated, unsheathed, multi stranded and 4.0 Sqmm for earth continuity conductor, complete all as specified
Supply and fixing of Modular Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified.
Supply and fixing of Modular Socket 6A/16A - 2/3 pin combined 2 module, 230 volt,multipurpose, complete all as specified.
Supply and fixing Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge.
Supply and fixing Modular switch 1 way 16A, 1 module single pole complete all as specified and directed by Engr-in-charge.
S&F modular type fan regulator 120W complete all as specified and directed.
Supply and fixing ceiling rose surface bake lite 65 x 30 mm with 3 terminals complete all as specified and directed by Engr-in-charge.
S & F in repairs Bed side fancy LED Light of minimum 6 - 9 W, 3000K warm/cool day light with connectors and drivers as per site requirements complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs LED strip light of minimum 25 W, IP-65 rating 3000K warm/cool day light with connectors and drivers as per site requirements complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Multi colour Flood Light LED light of minimum 1000 Lumens (10W) 3000K warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old unserviceable fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Multi colour Flood Light LED light of minimum 6000 Lumens (60W) 3000K with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old unserviceable fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Flood Light LED light of minimum 100W, 3000K warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old unserviceable fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Flood Light LED light of minimum 60W / 70W, 3000K warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old unserviceable fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Focus Light LED light of minimum 1000 Lumens (10W) 3000K warm/cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old unserviceable fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Bollard Light LED light of minimum 900 Lumens (9W) 3000K cool day light with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including taking down old unserviceable fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix loopin loopout fuse junction box made out of PVC, weatherproof and locking screw, PVC connector 4 Way 32 Amps rating heavy duty mounted in the box fitting on steel tabular pole at a height not more than 1.0m above ground level with the help of clamps two nos of Fl 20x3 mm and suitable nuts and bolts complete all as directed.
Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed.
Supply and fix On Load Automatic change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps complete all as specified and directed.
Supply and fix Water heater storage type, electric,capacity 10 litres, copper storage tank,BEE 5 star rated including Hot and cold heavy duty pipes, complete installation, testing and commissioning all as specified and as directed by Engg-In Charge.
S & F Supply & fix Air Circulator wall mounted fans decorative type 230 volts single phase oscillating 400 mm sweep suitable for wall mounting with 5 years on site replacement warranty complete all as specified and directed by Engg-in-Charge.
S & F in repairs PVC Body Exhaust fan with louver of size 200 / 250mm sweep exhaust fan ,complete all as specified and as directed.
M&L for removing the old rusted DB/steel DB covers of any specification and any type complete after dressing the cable of any size and securing it properly and filling the cavity/blank space with cement mortar of 1:3/brick masonary work and applying birla putty on wall surace to achive even and smooth surface and applying two coat of distemper on wall including primer complete and fixing the new DB of any specification all as directed and specified by Engr-in-charge. Note : New DBs will be measured separately as independent item under this schedule.
Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), VTPN MCCB DB, 415 volt, 8 Way, with MCCB as incomer and MCB as outgoing, IP-65 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified.
Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall),SPN, 240 volt, 12 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified.
Supply and fixing of MCCB 100 Amp, 415 Volt, 16KA, 4 Pole, complete all as specified
Supply and fixing in repair of RCBO DP 30mA, 40A to 63A, 230 Volt, complete all as specified and directed.
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified
Supply and fixing of MCB 63Amp, 415 Volt, TP/TPN, breaking capacity 10 KA 'C' series, , complete all as specified
Supply and fixing of MCB 6 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified
M&L for sub main wiring with 2 run of 4 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC surface/concealed conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified and directed by Engg-in-Charge. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls if needed and making good the disturbed surface are included in the quoted rate.
M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6.0Sq mm drawn through PVC surface/concealed of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified and as directed by Engr-in-Charge. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the quoted rate.
M&L for sub main wiring with Four run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and two run of copper earth wire 10.0Sq mm drawn through PVC surface/concealed of 32 mm dia, including taking down unsv sub main wiring of any type, complete all as specified and as directed by Engr-in-Charge. Note: Copper conductor four run and two run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the quoted rate.
Supply lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed by Engr-in-charge.
Supply lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed by Engr-in-charge.
Supply lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply and laying in trenches un- re-inforced pre cast concrete cable cover class LV,type I, flat size 250x150x40 mm complete all as specified & directed
Material and labour for 40 mm dia steel water tubes 'light grade' galvanised for cable protection including sealing both ends complete all as specified and as directed by Engineer in charge
Material and labour for cutting existing road / PCC / drain for laying of underground cable and including necessary earth work and making good to match with the exisitng surface with PCC1:3:6 type CI using 20mm graded aggregates complete all as specified and as directed.
M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with Galvanize earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 5, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion.
M&L for 25 x 3mm aluminum strip for earthing and lightening protection connection to building / Roof etc, complete all as specified.
S& F for modular switch 1way 16 Amps, 1 module 230V of 1 module complete all as specified and directed.
S& F for modular socket outlet 3 pin, 6 Amp 2module 230V complete all as specified and directed.
S& F for modular socket outlet 3 pin, 6/16 Amp 2module 230V complete all as specified and directed.
Supply and fixing ceiling rose surface bake lite 65 x 30 mm with 3 terminals complete all as specified and directed by Engr-in-charge.
SRIESWARI ENTERPRISES
SRI SRK ENGINEERS
ESWAR ENTERPRISES
SRI JAYANTH ASSOCIATES
Sri balaji Constructions
K V P RAJU
Bidder Name
K V P RAJU
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .