Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹4.1 Cr Quoted ₹4.2 Cr | L1 | Accepted-AOC Amount after Schedule of Credit |
| 2 | L2₹4.5 Cr+₹32.1 L (7.68%)Rejected-Finance | ₹4.5 Cr+₹32.1 L (7.68%) | L2 | Rejected-Finance not Being Lowest |
| 3 | L3₹4.5 Cr+₹36.5 L (8.73%)Rejected-Finance | ₹4.5 Cr+₹36.5 L (8.73%) | L3 | Rejected-Finance not Being Lowest |
| 4 | L4₹4.7 Cr+₹47.7 L (11.4%)Rejected-Finance | ₹4.7 Cr+₹47.7 L (11.4%) | L4 | Rejected-Finance not Being Lowest |
| 5 | L5₹4.7 Cr+₹49.4 L (11.8%)Rejected-Finance | ₹4.7 Cr+₹49.4 L (11.8%) | L5 | Rejected-Finance not Being Lowest |
Tender Value
₹5.5 Cr
EMD Value
₹6 L
Closing Date
23 Oct 2024, 6:00 pmClosed
CE(Navy) Visakhapatnam
CE(Navy) Visakhapatnam
SPECIAL REPAIRS TO KRISHNA BUILDING P 137 AND ALLIED SERVICES AT NAUSENA BAUGH UNDER GE (NB) VISAKHAPATNAM
2024_MES_671233_1
85448
Open Tender
Civil Works
Item Rate
365 days
Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE(NB) Visakhapatnam
₹6 L
20 Dec 2024
3 Sept 2024
30 Oct 2024
3 Sept 2024
23 Oct 2024
9 Oct 2024
3 Sept 2024 - 10 Sept 2024
Amount
Removal existing treatment any type, any thickness and their Roughening surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc., all as specified and as directedfrom 13th Storey to 16th Storey.
Brushing neat cement slurry with 3 Kg of cement per square metre from 13th Storey to 16th Storey all as specified and as directed.
M&L for 25 mm th PCC 1:2:4 type B1 (using 20 mm graded aggregate) mixed with WPC as directed and laid on RCC slab to make surface levelled for proper slope finished even and fair all as specified from 13th Storey to 16th Storey all as specified and as directed. Note: WPC measured and paid separately.
M&L for rendering 10 mm th in CM 1:4 on concrete srfaces to make surface smooth to receive water proof treatment including mixing WPC as per manufacturing instructions from 13th Storey to 16th Storey all as specified and as directed. Note: WPC measured and paid separately .
Supply only Integral water proofing compound
Supply and laying hyperlas standard 3 Kg/Sqm polymeric water proofing membrane incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100 gms/sqm followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2 Kg/Sqm each at top and bottom of the membrane followed by a coat of bituminous aluminium primer @ 100 gms/Sqm complete including sealing all joints by thermo fusion with minium 10 cm overlap all as per manufacturer's instructions all as specified and as directed.
M&L for cool roof tiles of size 300x300, 7mm thick & Solar Reflectance Index (SRI) value more than 90 as on roof laid over screed bed/bedding layer of 10 mm thick in CM 1:4, joint Shall be kept as 3mm filled with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely complete all as specified and as directed. Note: The colour / shade / design of tile shall be approved by GE
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness all as specified and as directed.
Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for 25 mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in sub base of floors all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for 600x600 mm size, 7 to 8 mm thick non-skid coloured (light shade) ceramic joint free tiles with tile spacer of minimum 3 mm thickness as in floors set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely and pointed in white or coloured to match the shade of the tile and laid over screed bed or bedding layer in CM 1:6, 15 mm thick complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
All as per SI item No 17 above (including tile spacer, epoxy grout, masking tape etc), but as in skirting, dados etc, including rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 as in backing coat for fixing of tiles complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for 300x300 mm size 7 to 8 mm thick non-skid coloured (light shade) ceramic joint free tiles with tile spacer of minimum thickess 3mm as in floors set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, grout shall be througly cleaned immediatlely and pointed in white or coloured to match the shade of the tile including laying over screed bed or bedding layer in CM 1:6, 15 mm thick complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
All as per SI item No 25 above but 300x450 mm glazed ceramic tiles in vertical surface (including tile spacer, epoxy grout, masking tape etc) and rendering 10 mm thick on fair faces of brick work/ concrete surfaces in CM 1:4 complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Machine cut kota stone slab flooring 20-25mm thick laid over screed bed 15 mm thick in CM 1:6, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for PCC 1:5:10 type E2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for rendering 10 mm thick on brick work or concrete surfaces in CM 1: 4 mixed with WPC and finishing the surface even and smooth without using extra cement upto 4th storey complete all as specified and directed. (Note:- WPC shall be measured separately)
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for applying Chemical Injection Treatment in the form of Pressure Grouting by drilling 20 mm dia holes, 60 mm deep @ 100 cm grid at at junction of bottom floor and all the internal wall surfaces of the sunken slabs of toilet by injecting epoxy Grout "CONBEXTRA EP 10" of M/s. Fosroc Chemicals or its equivalent in M/s Sika or M/s STP or M/s Choksey Chemicals or M/s Batik and applying a coat of Brush Bond RFX of M/s. Fosroc Chemicals or equivalent approved water proofing coating as per manufacturer's instructions complete all as required, as directed at site and as described in clause of PS.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Dismantling floor, hearth or wall tiling including CM bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish outside MD Land within 100 m all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Reinforced Cement Concrete (Nominal Mix) 1:2:4 type B1 (using 20 mm graded stone aggregate) for slabs suspended on walls, beams and columns, floors, roofs, landings and in shelves and the like all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Reinforced Cement Concrete (Nominal Mix) 1:11/2:3 Type A1 (using 20 mm graded stone aggregate) for shelves and the like all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Reinforced Cement Concrete (Nominal Mix) 1:11/2:3 Type A1 (using 20 mm graded stone aggregate) in Chajjas and the like all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Fair finished flat Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200 mm thick all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Fair finished flat Form work to sides and soffits of shelves including supports etc. all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Form work on fair finished flat surfaces of Chajjas including edges all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for mild steel TMT round bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Pre-cast cement concrete solid block masonry 1:3:6 type C1 (20mm graded Aggregates) exc. 10 cm in width and setting in CM 1:6 complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Providing precast cement concrete solid building blocks masonry 1:3:6 Type C1 (20mm graded Aggregates) or slabs 10cm thick (with plain or interlocking joints as directed) and setting in CM 1:4, as in walls complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises where directed and leaving the work clear complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 finished even and smooth withut using extra cement complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6, 5mm thick mixed with WPC and finished fair and even without using extra cement complete all as specified and as directed. Note :- WPC measured separately.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in CM 1:3 and finished fair and even without using extra cement complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F stainless steel sink with drainage board over all size of 915x460 mm bowl size 410x330x160 mm with plugs washers and waste coupling upto 04th storey including necessary supporting brackets complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F stainless steel plate rack 1.50 mm thick of over all size 1200x900x250 mm as per trade pattern upto 04th storey complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash up to 4th storey complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for preparing old surfaces of walls by brooming down or by steel wire brushing and applying one coat of white wash upto 4th storey complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Complete removal of existing treatment of any description on ceiling surfaces by using vacuum based sanding machine, removal of nails and applying min 1 mm thick Cement based Wall Care Putty on ceiling by using multipurpose mixture for proper mixing of putty for application including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one of alkali resistant primer on ceiling surfaces complete all as specified and as directed. Note:- The contractor shall carryout distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for preparing newly plastered surface of any description on Ceiling and applying min 1 mm thick Cement based Wall Care Putty on ceiling by using multipurpose mixture for proper mixing of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one of alkali resistant primer on wall surfaces complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for preparing newly plastered surfaces of ceilings and and applying three coats of white wash up to 4th storey complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for preparing newly plastered wall surfaces and applying two coats of Acrylic washable Distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty (min 2.5 mm thick) on walls by using multipurpose mixture for proper mixing of putty for application of putty including rubbing with sand paper to obtain a smooth surface complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Complete removal of existing treatment of any description on wall surfaces by using vaccum based sanding machine, removal of nails and applying min 1 mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one of alkali resistant primer on wall surfaces complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for preparation of old painted wooden surface of any description not othrwise described over 10cm width or girth and applying two coats of synthetic enamel paint upto 4 th storey complete all as specified and directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for preparation of new or previously untreated wooden surface of any description not othrwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer upto 4 th storey complete all as specified and directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Complete removal of existing suraface of any description and girth and not otherwise described in any location and applying two coat of synthetic enamel paint complete all as specified and as directed .
M&L for Complete removal of existing treatment of any description on walls/ceilings surfaces by using vaccum based sanding machine, removal of nails & applying min 1mm thick cement based wall care putty including rubbing with sand paper to obtain a smooth surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint (100% Acrylic) by using auto roller/ airless sprayer over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls complete all as specified and as directed. Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting through their authorised applicators before commencement of the work to GE for approval.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for two coats of Weather Proof Exterior Emulsion Paint (100% Acrylic) by using auto roller/ airless sprayer over a Coat of Exterior Primer of same manufacturer as that of paint on newly plastered walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vaccum based sanding machine and appying two or more coats of cement based wall care putty (min 2.5 mm thk) complete all as specified and as directed. Note:- The contractor shall carryout Exterior Emulsion Painting and allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering through their authorised applicators before commencement of the work to GE for approval
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30 cm high upto 04 storey complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Taking down CI pipe soil, waste and rain water pipes (any size or pattern) including all fittings, heads, shoes. Bends, swan-necks etc up to 04 storey including cleaning or refixing or removal to store complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 75 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring jointsfixed to walls upto 04 storey complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 110 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls upto 04 storey complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 75 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 110 mm bore UPVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for PVC (SWR) plain Floor/ Nahani trap of 75 mm dia outlet with grating including jointing with solvent cement complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 75 mm bore UPVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 110mm bore UPVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 75m m bore UPVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 75mm bore UPVC (SWR) junction single T equal / unequal complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F110mm bore UPVC (SWR) junction single T Equal / unequal complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Taking up or down 25 mm or 32mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Taking up or down 40 mm or 50mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Supplying and laying of CPVC pipes 20mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Supplying and laying of CPVC pipes 25mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Supplying and laying of CPVC pipes 40mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Supplying and laying of CPVC pipes 50mm dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs 15 mm bore chromium plated bib taps chrome, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. up to 4 th storey ,Cat no Jaquar- OPP-CHR-15037PM or equivalent cat No & make as per list of makes complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs fancy type chromium plated with long shank and cup (Concealed type) 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions including taking down the existing fitting complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs Fancy type chromium plated 15 mm bore Angle/ plain Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs Chromium plated shower rose 125 mm size with or without swivel joints (Cat No. Jaquar OHS-CHR-1661 or equivalent cat No & make as per list of makes) complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs 50 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs 50 mm dia Ball brass Valves, high pressure, with polythene float and fly nut, screwed for Iron pipe or brass ferrule complete all as specified and as directed..
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs Stainless steel Soap dish, any type, fixed to plugs with CP brass screws (Cat No. Jaquar-CPA-CHR-1131 or equivalent cat No & make as per list of makes) complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs Towel Ring sqaure, Stainless steel, Fancy Type fixed with chromium plated brass screws and wooden/plastic cleats weighing minimum 90 gms (Cat No. Jaquar-CPA-CHR-1121 or equivalent cat No & make as per list of makes) complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs Brass Chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges (Cat No. Jaquar-AQN-GRF-7711B or equivalent cat No & make as per list of makes) complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs Vitreous China (white) EWC type water closet floor mounted (size 560x440x395 mm or nearest size) confirming to IS 2556 part II of pattern 1 having P trap with 10 litres PVC capacity valve less syphonic action type flushing cistern low level (white) with inlet, ball valve, float and handle including brackets (SLIM LINE or equivalent) including PVC flush pipe 32 mm dia, plastic seat cover of white colour to WC (which shall be thermosetting materal confirming to IS 2538, underside of seat shall be flat and seat shall be of solid moulding 3mm thick & cover shall be 3 mm thick), hinging device brass chromium plated 2 bolts per seat, 4 numbers rubber plastic buffers including removing the existing water closet complete upto 4th storey complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs Rotational moulded Polythene (HDPE) rectangle Water storage loft Tank, 225 Liters Capacity hoisted and fixed in position upto 4 th storey including dismantling water tanks and removing to store complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs 20 mm dia Ball brass Valves, high pressure, with polythene float and fly nut, screwed for Iron pipe or brass ferrule complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F Vitreous China Ware Wash hand basin white, flat back, size 550x400 mm with 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed including removing the existing Basin, pillar tap and brackets and fixing new brackets complete (Cat No. Jaquar-SLS-WHT-6901 or equivalent Cat No & Make given in list of makes) complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Taking down Chowkats or frames with shutters not exceeding 1.5 Sq. m each (Without taking off shutters from the frames) complete all as specified and as directed..
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Taking down Chowkats or frames with shutters exceeding 1.5 Sq. m but not exceeding 4 Sq. m each (Without taking off shutters from the frame) complete all as specified and as directed..
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window Frames/ Chowkhats of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as spefied and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, complete all as specified and as directed. (Note:- SS butt hinges with necessary SS screws shall be measured separately)
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Powder coated aluminium sections of approved colour for doors, Windows, Ventilators, Partitions, with frames and shutters fully or partly glazed, sliding / openable, with extruded aluminium sections not less than 1.5mm thick and powder coating not less than 60 micron thick including necessary jointing cleats, rubber beading, neoprene packing, aluminium snap beading, screws, powder coated aluminium fittings such as handles, aluminium butt hinges , aluminium tower bolts, stainless steel friction hinges, locking arrangements etc. complete all as specified and as directed. Notes: (a) The size of aluminium extruded sections shall conform to Designation 63400 all shall be as specified in relevant IS code and as specified in MES Schedule Part - I. (b) Panel inserts such as Glass / Particle board / Gauze shall be measured and paid separately at supply only rates. (c) Weight of aluminium sections shall only be accounted for payment purpose. Weight of aluminium Handles, Butt Hinges & Tower Bolts shall not be accounted for payment purpose. (d) The unit rate quoted shall be deemed to include for cost of jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, Peg stays, locking arrangements etc., and fixing only of panel inserts of glass / particle board / gauge etc. (e) While making payment in kgs, the wt arrived from differerent sections shall be tallied with total wt of doors, Windows, Ventilators, Partitions with frames and shutters.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F chrome plated Corner Glass Shelf 150x150 mm with all required fittings upto 16th storey complete all as specified and directed. Make :- Cera Cat No. :F5005102 or equivalent.
S&F Glass shelf of size 450x150 mm near WHB with chromium plated support brackets upto 16th storey complete all as specified and directed.
S&F factory made Double rebated Wood Polymer Composite (WPC) solid door/ window Frames/ Chowkhats of size 65x125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as specied and as directed. Note: The hold fasts/ lugs/ fasteners shall be measured and paid separately under relevant items of this Schedule/ BoQ.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat of size 65x100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per directed. Note: MS hold fast/lugs or SS dash fasteners shall be paid for separately.
S&F factory made single rebated Wood Polymer Composite (WPC) solid door/ window Frames/ Chowkhats of size 50x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as specied and as directed. Note: The hold fasts/ lugs/ fasteners shall be measured and paid separately under relevant items of this Schedule/ BoQ
M&L for applying food grade epoxy coating treatment to water tank on inside surface after proper surface preparation, carry out cementitious injection grouting at leakage points using Plasticized expansive grout admixture, treatment of construction joints using polymer modified mortar prepared by using SBR Latex-screed modifier cum bonding agent, application of polymer modified vatta/ fillet at floor-wall junction prepared by using SBR, filling pipe cut-outs using Non shrink cementitious grout, application of one coat of epoxy/PU primer and two coats of Solvent free food grade epoxy resin coating @ 200 microns DFT in 2 coats etc. complete including all tools and tackles as per manufacturer’s specification. Food grade epoxy coating shall be having elongation 100%, Adhesive bond strength - > 1 Mpa, Pot life of 30 min @ 30 °C and cured film shall be non-toxic and shall meets the requirements of IS: 9833:1981. Note: The Contractor shall furnished 10 years warranty for the coating. Application shall be carried out by approved applicator of manufacture and as per recommended by manufacturer. Actual applied area of epoxy coating shall be measured for payment.
S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 0.9 mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face fixed with screws to timber frame work including veneer polishing complete all as specified and as directed..
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 35 mm thick factory made Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. The sizes of members of shutters shall be as specified in SSR Part I, Section 8, Clause 8.20 (a) complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 35mm thick factory made second class hard wood, kiln seasoned and chemically pressure treated plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm thick veneered partilce board complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Plain Cement Concrete 1:3:6 Type C1 (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5 m span, cills and other similar bands, plinth courses, parapets, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles confirming to (Fe 290, grade E 165) complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Supply only Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with Stainless steel wire staples complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Supply only 5.0 mm thick float glass, ordinary quality fixed to aluminium windows in squares exceeding 0.5 Sq. m in each pane complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy. up to 4th storey complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 125 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 100 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 150 mm long extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 100 mm long extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150 mm complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F stainless Steel curtain rod 25mm dia with suitable chromium plated brackets, with 100 mm PVC rings and Designer knobs at ends matching to curtain rod of make as as approved by GE upto 04 storey complete all as specified and as directed. Note: Additional supporting bracket shall be provided if length is exceeding 1.2m and rate quoted shall include for the same.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Dismantling ply wood cub board shutters including cubboard shelves complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for 18mm thick plywood BWR grade type BB fixed with Fevicol and nails for working table/storage almirah to the size and pattern as shown in Drg complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for decorative laminate 0.90 mm thick type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Ist class HW plain cover fillets square, rectangular or triangular in section bull nosed, splayed chamfered or rounded on one edge or face in I st class HW sectional not exc 3 sqcm complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for 1st class HW plain cover fillets square, rectangular or triangular in section bull nosed, splayed chamfered or rounded on one edge or face in I st class HW sectional area exc. 6 Sqcm and not. exc 13 Sq cm complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F SS hinges 75mm size extruded with stainless steel pin type D-11 complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F mild steel, bright finished or electro galvanised continuous (piano) hinges width of flaps (when open) 40mm complete all as specified and directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F brass Hat and Coat hooks, Solid body, 175mm to 250mm size upto 04 storey complete all as specified and directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F brass cup board lock 75mm size 4 lever with duplicate keys complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F SS handles extruded fabricated type 100mm size complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F brass handles extruded fabricated type 150mm size complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F magnetic catch all as per specification complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs 300 mm, Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F Mortice night latch of size 82mm, 7 levers, Zink based die cast alloy body with two keys upto 04 storey complete all as specified and directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Providing and injecting chemical emulsion for Anti Termite Treatment along the external wall below concrete or masonry apron using chemical emulsion at the rate of 2.25 litres per linear metre including drilling and plugging holes etc., in apron complete all as specified and as directed.
M&L for treating the soil under exiting floor using lindane emulsifiable conforming to IS: 632 with emulsion @ 1 litre per hole 300mm apart including drilling and plugging 12mm dia hole with cement mortor 1:2 (1 cement : 2 sand) to match the existing floors complete all as specified and as directed.
M&L at point of contact to wood work by chemical emulsion (water base solution) @ 0.5 ltr / hole by drilling 6mm dia holes at a downward angle of 45 degree at 1.5 mm centre to centre and sealing the same upto 4th storey complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Taking down, easing, adjusting and refixing in the same opening for shutters and chowkats of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each and refixing builders hardware as required including renewal of unserviceable screws etc. complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F Second class hard wood small fittings such as brackets of any type, shaped door and window stops and the like including all necessary labour, articles not exceeding 200 Cu. Cm each complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F 50mm long extruded stainless steel Butt hinges with galvanized mild steel hinge pin complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Removing of debris to out side the premises to a distance of 5 km complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F PVC corner half round corner beading not exe 15 mm girth fixed to tile junctions all as directed up to 16th floor complete all as specified and as directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repair 2 way bib tap fancy type chromium plated 15mm bore cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe complete all as specified and directed. (Make Prayag cat No 6412 or equivalent cat No. as specified in list of makes)
S&F powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/ stainlesssteel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and direction.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Supply and installation of non returnable grouting packer 8 mm dia and drill hole should be 10 mm dia for epoxy filling. The item rate includes cleaning of the holes in position with all equipment, putty, machinery, tools as recommended by the Manufacturer complete all as specified and as directed.
Providing & grouting with MONOPOL & KP 250/ HP250 injection grout for cracks caused by structural distress such as shear cracks, flexural cracks, tensile cracks, chemical shall be injected with low viscosity epoxy resin complete all as specified and as directed.
Drilling and fixing PVC nozzles and injecting epoxy cementitious polymeric grout in beams, columns or slab elements have honeycombing inside after removal of loose concrete material, with injection of POLYMER MODIFIED CEMENT GROUT in the honeycombed areas. The same methodology is used to inject construction joints complete all as specified and as directed.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti-corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous especially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. Area of reinforcement for which rust proof /anti corrosive treatment is applied is measured.
Supply and apply a cement-based epoxy modified three-component anti corrosive coating and bonding slurry for rebar corrosion protection system with following method. Surface preparation on concrete shall be free from dust, loose material, surface contamination and materials which reduce bond or prevent suction or wetting by repair materials. Delaminated, weak, damaged and deteriorated concrete toadhere necessary sound concrete shall be removed by suitable means. Substrate shall be Saturated Surface Dry (SSD) with no standing water. Steel reinforcement Rust, scale, mortar, concrete, dust, other loose and deleteriousmaterial which reduces bond or contributes to corrosion shall be removed by blast cleaning or other means of mechanical abrasion and reinforcement fully exposed and have all corrosion removed. Make:Friazinc R or Equivalent
M&L for providing Polymer modified cementitious mortar (PMM) as follows:- (i) Dry the sub strata surface and clean it free from debris & dust (ii) Apply Epoxy bond coat on the sound sub strate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 40 mm thickness. Note : Application of PMM shall be preferably be in coats of approx 10mm thickness. PMM work shall be executed in fairly rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed upto 16th floor
M&L for Micro concrete Rendroc RG (S) thickness not exceeding 40 mm for structural members all as per manufacturers instructions complete including leak proof form work coated with reabol mould release agent all as specified and directed including all necessary scaffolding complete all as specified and directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Providing & Pouring Micro concreting M-40 grade :- (i) Dry the concrete substrate surface and clean it free of debris & dust (ii) Apply Epoxy bond coat on the sound concrete sub strate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above, pour Micro concreting M-40 grade, Make : Master Emaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, formwork, lead & lift of materials, transportation etc., to carry out the complete work upto 16th floor all as specified and directed.
M&L for Additional Reinforcement for repair, rehabilitation work including main bar and stirrups: Supply and Providing extra reinforcement at the area where corrosion has gone above 25 % with proper over lapping. Supply of reinforcement steel and fixing using welding or lapping orDowel or Anchoring system on existing system and placing in position, at all heights & depths, of high strength deformed weld-able quality reinforcement bars of grade Fe415 or Fe 500 higher grade conforming to IS:1786 (latest version) as per drawings for RCC foundations, beam, column, slab and structures, straightening, cleaning, cutting, bending ,welding to required shape and length as per details, double binding wire with contractor's own 16 SWG black soft annealed binding wire, welding if required to form a rigid cage and placing with proper cover block, supports, chairs, spacers etc., complete as per instructions. HYSD bars of Fe 415 or Fe 500 grade and other higher Grade may also be allowed. However, extra payment will not be made for different grade of reinforcement steel. Make :HILTI -HIT RE 500 POST INSTALLED REBAR or Equivalent (Rebar Insrting chemicals) complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Removing the Veg/plant growth from the surface of building complete with roots at any height and applying chemical to prevent further growth and making good using CM 1:3 and applying the finishes to match with existing surface including removal of debris out side premises complete all as directed upto 16th storey complete all as specified and as directed.
Dismantling Structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed.
S&F Mild steel work in framed work such as grills, gratings,framed guard bars, barred iron doors, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified and as directed.
S&F in Repairs 1.00 mm thick Galvanized Iron sheet in steel gates, etc., cut to size, holes punched including fixing to MS clamps with necessary bolts and nuts complete all as specified and as directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for plain /Reinforced cement concrete type B1 1:2:4 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 m span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering slightly complete all as specified and as directed.
M&L for preparing old surfaces of steel and iron work of any description over 10 cm width or grith not otherwise described applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laidd, bedded and pointed in any mortar complete all as specified and as directed.
M&L for 18-20 mm Granite work jet black (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in, set in screed bed/ bedding layer, 15 mm thick in CM 1:6 complete including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for 18-20 mm Granite work jet black (table rubbed and polished) for wall lining (veneering to wall) 10mm thick in CM 1:3 and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
M&L for Green marble slab 16 to 18 mm thick (table rubbed and polished) machine cut as in flooring and landings of stair case over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and half rounding edges over and including screed bed or bedding layer, 15 mm thick in CM 1:6 upto 04 storey complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
S&F in repairs Wall Mixer with Provision for Overhead Shower with 115mm long bend pipe on upper Side, Connecting Legs & Wall Flanges including all necessary fittings (Jaquar make catalogue No SOL-6273UPR or equivalent Cat No. & Make as per list of makes) complete all as specified and as directed.
All as per above item but from 5th Storey to 8th Storey
All as per above item but from 9th Storey to 12th Storey
All as per above item but from 13th Storey to 16th Storey
Excavation over areas not exceeding 1.5 m deep and getting out in Soft/ Loose Soil all as specified and as directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and leveled in layers not exceeding 15 cm thick, watering and ramming to a true surface all as specified and as directed.
M&L for 100mm thick PCC 1:2:4 type B- 2, (40mm graded aggregate) as in sub base of flooring/ hard standing all as specified and as directed.
Removing excavated soil to a distance execeeding 1.50 km but not exceeding 5 km and depositing where directed at a level not exe 1.50 m above the starting point complete all as specified and as directed.
M&L for sand filling under floors or in foundations below interlocking tiles path including watering and consolidation complete all as specified and as directed.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation, etc., and getting out in Soft/Loose soil.Complete all as specified and as directed. Note:- taking out drain pipe shall be measured and paid separately
Excavation in trenches, exceeding 1.5 m wide and exceeding 1.5 m and not exceeding 3m depth for foundation, etc., and getting out in Soft/Loose soil complete all as specified and as directed. Note:- taking out drain pipe shall be measured and paid separately
Demolition and breaking 150 mm dia., drain pipes (Salt glazed ware, AC or reinforced concrete set in cement mortar, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m Complete all as specified and as directed
Demolition and breaking 200 mm dia., drain pipes (Salt glazed ware, AC or reinforced concrete set in cement mortar, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m Complete all as specified and as directed
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and as directed
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes after they are laid and tested for pipes of 200 mm bore complete all as specified and as directed.
S&F 150mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed.
S&F 200mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard soil complete all as specified and as directed
M&L for Pre-cast cement concrete block masonry 1:3:6 type C2 (20mm graded Aggregates) with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete all as specified and as directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed
Demolition of reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m complete all as specified and as directed
M&L for precast RCC slabs factory made (SFRC) as in manhole covers in 1:2:4 type B1 using 20mm graded stone aggregate, set in cement mortar 1:4 complete all a s specified and as directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 150 mm dia., of pipe complete all as specified and as directed
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 200 mm dia., of pipe complete all as specified and as directed
M&L for plain /reinforced cement concrete 1:2:4 type B1 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 m span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering slightly complete all as specified and as directed
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation, etc., and getting out in Soft/Loose soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete (for base of manholes) complete all as specified and as directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 but except stone complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry 1:3:6 type C1 (20mm graded aggregates) with solid blocks, exc., 10cm in width and setting in mortar, complete full brick thick walls set in cement mortar 1:4 complete all as specified and as directed.
M&L for precast RCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) 50 mm thick as in Jallies or louvers including all mouldings and set in Cement Mortar 1:4 complete all as specified and as directed.
M&L for dismantling of RCC jallies of any thickness and disposal of unserviceable materials, debris and rubbish out side MD Land complete all as specified and as directed.
M&L for preparing of old plastered surfaces and applying two coats of white wash on surfaces of walls all as specified and as directed.
Demolition of RCC in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed.
Taking down carefully by unscrewing from boards, TV Sockets, LAN sockets and Computer jack, etc.
Taking down unserviceable main switches, DBs, bus bars chambers any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and as directed.
Taking down unserviceable single pole and neutral enclosure with two pin and earth plug and socket any type/ any rating including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and as directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid steel conduits/PVC casing caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and as directed.
Taking down old / perished earth pits and making good the disturbed surface of complete all as specified and as directed.
Taking down after disconnection the Exhaust fans any make, model, size and type from its position complete with all the parts i.e. down rod, canopies, fan blades etc.complete all as specified and as directed.
Taking down after disconnection the ceiling fans any make, model, size and type from its position complete with all the parts i.e. down rod, canopies, fan blades etc.complete all as specified and as directed.
Taking down existing storage type water heater of any capacity of any type and size by disconnecting from Power socket, carring out necessary repair and painting including cleaning and inner water tank, removing of hard water deposites and connected back and refixing in original position including testing and commissioning complete all as specified and as directed.
Taking down after disconnectIon of existing electric meter any make model and type from wall complete all as specified and as directed.
Taking out after disconnectIon of existing LT panel any make model and capacity from the exisiting location with complete demolition of existing plinth/ foundation of LT panel including cleaning of site complete all as specified and as directed.
M&L for point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (minimum) medium grade (ISI marked) surface fitted type including Flush type metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS (ISI marked) as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed. Note:- The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface
All as per above item but for One light Point controlled by 2- Way Switch complete all as specified and as directed.
All as per above item but for one 5 Amps socket independent including 1.5 Sqmm earth continuty FRLS Copper Cable complete all as specified and as directed.
All asper above item but with 2.5 Sqmm FRLS copper cable for one 15/5 Amps Multipurpose power point.Including 2.5 Sq mm FRLS copper conductor cable for earth continuity conductor and connecting it to earth complete all as specified and as directed.
All as per above item but with 4.0 Sqmm FRLS copper cable for one geyser/AC point including 4.0 Sq mm FRLS copper conductor cable for earth continuity conductor and connecting it to earth complete all as specified and as directed.
S&F TV Socket outlet with metal box complete all as specified and as directed.
S&F switch Modular type single pole 6 Amps One Way AC 230V, 50HZ complete all as specified and as directed.
S&F switch Modular type single pole 6 Amps Two Way AC 230V, 50HZ complete all as specified and as directed.
S&F Bell Push Modular type single pole 6 Amps AC 230V, 50HZ complete all as specified and as directed.
S&F Modular type socket 5A AC 230V, 50HZ complete all as specified and as directed.
S&F Modular type switch 16A AC 230CV, 50Hz complete all as specified and as directed.
S&F Modular type Socket 6A/16A multi purpose AC 230CV, 50Hz complete all as specified and as directed.
S&F Modular Fan regulator, step type 120W - 2 module complete all as specified and as directed.
S&F Celing rose surface backlite 63 mm dia two to three terminals complete all as specified and as directed.
Fixing only of Celing rose surface backlite 63 mm dia two to three terminals complete all as specified and as directed.
S&F Buzzer, Ding Dong AC. 230 Volts, single pole complete all as specified and as directed.
S&F Single pole and neutral enclosure with two pin and earth plug and socket with 20 Amps MCB SP complete all as specified and as directed.
M&L Sub main wiring with 2 runs of 4.0 Sqmm PVC insulated FRLS Copper conductor cable including PVC conduit of Suitable along with one run of 4.0 Sq.mm FR copper cable for earth continuity conductor as earth lead for sub main wiring and connecting to common earth dolly complete all as specified and as directed.
M&L Sub main wiring with 2 runs of 6.0 Sqmm PVC insulated FRLS Copper conductor cable including PVC conduit of Suitable along with one run of 6.0 Sq.mm FRLS copper cable for earth continuity conductor as earth lead for sub main wiring and connecting to common earth dolly. (TPN to SPN DB) complete all as specified and as directed.
Labour only for Sub main wiring in PVC conduit of Suitable along with earth continuity conductor as earth lead for sub main wiring of any size or specification including connection complete all as specified and as directed.
S&F TPN DB 4 Way with 415 Amps rated bus bar Double Door complete all as specified and as directed.
Fixing only TPN DBs any make Model any Rating including all necessary connection complete all as specified and as directed.
S&F 415 V, 10 kA 'C' curve miniature circuit breaker (MCB) of Three poles and Netural current carrying capacity 63 A in the MCB DB complete all as specified and as directed.
Fixing only miniature circuit breaker (MCB) of Three poles and Netural of any make, model and any rating including of all necessary connection in DB complete all as specified and as directed.
S&F SPN DB 12 Way with 200 A rated bus bar Double Door complete all as specified and as directed.
Fixing only SPN DBs any make Model any Rating including all necessary connection complete all as specified and as directed.
S&F 240 V, 10 kA 'C' curve miniature circuit breaker (MCB) of single poles and Netural current carrying capacity 32 A, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.
Fixing only miniature circuit breaker (MCB) of single poles and Netural of any make, model and any rating including of all necessary connection in DB complete all as specified and as directed.
S&F 240V, 10 kA 'C' curve miniature circuit breaker (MCB) of single poles, current carrying capacity 6 to 32 A, in the MCB DB Complete with connection testing and commissioning.
Fixing only miniature circuit breaker (MCB) of single poles of any make, model and any rating including of all necessary connection in DB complete all as specified and as directed.
S&F LED lights fitting 1x 20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Fixing only LED tube light fitting any Watt any make and model, obtained from taking down and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Fixing only LED mirror light fitting any watt any make and model, obtained from taking down above, 220V, AC and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Fixing only LED lights fitting building security light incl all fixing arrangement obtained fromtaking down above, 220V, AC and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repairs LED Bulb, 9 Watts Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, complete all as specified and as directed.
S&F Rigid non-metalic PVC conduit (20mm dia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and as directed.
S&F Aviation obstruction light of LED type integral light comprising of aluminium housing with polycarbonate enclosure,302 nos LED are provided along with other fixing aceessories internal prewired and including taking down existing light fittings of any complete all as specified and as directed Make : Bajaj Cat No BGAV 302 LEDor equialent in Crompton or Philips
S&F XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 4 core 10 Sqmm from ground floor indoor panel to TPN DBs at each floor complete all as specified and as directed.
S&F GI Tube light grade 40 mm dia with all fittings fixed to walls and ceiling or laid in floors for cable protection complete all as specified and as directed.
Fixing only exhaust fan of any Make, model, sweep and type including over hauling, servicing, painting with two coats of enamel paint including re-fixing the fan at new/old location complete all as specified and as directed.
S&F PVC body exhaust fan 250 mm sweep AC single phase 1200 RPM complete with accessories electric connection including making necessary holes in walls complete all as specified and as directed.
Fixing/ Hanging only Ceiling fan of any make, model, sweep and type including connecting up including provision of cable from ceiling rose/connector to fan painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip 32x6mm (up to 7.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode 20 mm dia for watering complete all as specified and as directed and tested on completion including taking down of existing earthings.
Scrapping and painting with two coats of synthetic enamel paint over a coat of primer on existing MS Box of size 900x600x150mm inside the wall for fixing of DBs and meter complete all as specified and as directed.
S&F Hot dip Galvanised Cable tray of size 75mm depth, 300mm width and 2mm thick (14 SWG) and standard length for fixing to wall including tee, cross, horizontal/vertical bends and reducer as required for fixing or arrangement of cables in side the cable tray with zip ties such as electrical cable after taking out of cables from existing conduits of any make and sizes and making good the disturbed surfaces to match with existing surfaces complete all as specified as and directed. Make: MEM/OBO/Legrand
S&F Galvanised iron Coupler plate of size 75mm including necessary hardware work complete all as specified and as directed. Make: MEM/OBO/Legrand
LT Cubical Panel board CPRI approved made out of CRCA sheet 2.0 mm thick indoor Compartmenatal Type totally enclosed , Dust and vermin proof with front opening, hinged doors with projected raised platform of suitable size with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc made of rust proof material including all as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 630 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following :- Incoming:(a) MCCB AC 3 Phase 415 V, 50Hz 4 pole, 315 A, breaking capactiy 36kA, Ics=100% Icu with adjustable thermal and fixed magnetic setting relays - 01 No. Outgoing:(a) MCCB AC 3 Phase,415 V, 50Hz 4 pole, 40 A breaking capacity 10 kA with adjustable thermal and fixed magnetic setting relays - 13 Nos. (b) MCB SPN 20 Amp-02 Nos (c) Multi function meter with all connected CTs-01 Set (d) LED indicating lamps with colour Red, Yellow, Blue - 03 Sets
Taking down old / perished earth pits and making good the disturbed surface of complete all as directed.
Taking down of Aluminium strip/ GI Strip of lightning conductor having any size and dimension (roof conductors)/down conductors) laid in trench/floor including taking down of clamps,nuts,bolts complete all as specified and as directed.
Taking down of Air termination, single pointed aluminium rod of any size complete all as specified and as directed.
S&F Aluminium strip of size 25x3.15 mm for lightning conductor (roof conductors)/down conductors) laid in trench/floor including necessery clamps, nuts, bolts and hylem sheet block complete all as specified and as directed.
Fixing only Aluminium strip of size 25x3.15 mm for lightning conductor (roof conductors)/down conductors) laid in trench/floor including necessery clamps, nuts, bolts and hylem sheet block complete all as specified and as directed.
S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long and fixed complete all as specified and as directed.
Fixing only of Air termination, single pointed aluminium rod 12mm dia and 300mm long and fixed complete all as specified and as directed.
S&F test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 nos 125mm long hexogonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
Fixing only electric enrgy meter retrived here in before and making electrical connection with suitable copper wire complete all as specified and directed.
Taking down existing smoke detector/manual call point/control panel and keep under the safe custody and refixing the same after completion of finishes complete all as specified and directed.
Taking down the existing control cable and keep under the safe custody and refixing the same after completion of finishes complete all as specified and directed.
S&F GI strip of size 32x6mm for lightning conductor laid in trench / floor including necessery clamps, nuts, bolts,insulator and hylem sheet block complete all as specified and as directed.
S V S ENTERPRISES (BID ID -3140984)
JMR INFRAS (BID ID -3141006)
P Govinda Reddy Infrastructure (BID ID -3140514)
VENKATA SAI SRINIVASA CONSTRUCTIONS PRIVATE LIMITED (BID ID -3141195)
CHHABINDRA KUMAR PRADHAN (BID ID -3140544)
VIJAY VINAYAKA INFRA (BID ID -3147895)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .