| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹2.2 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹2.3 Cr+₹7.2 L (3.29%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹2.3 Cr+₹7.2 L (3.29%) | L2 | Rejected-Finance BEING NOT LOWEST |
| 3 | L3₹2.3 Cr+₹12.0 L (5.48%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹2.3 Cr+₹12.0 L (5.48%) | L3 | Rejected-Finance BEING NOT LOWEST |
| 4 | L4₹2.4 Cr+₹22.0 L (10.0%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹2.4 Cr+₹22.0 L (10.0%) | L4 | Rejected-Finance BEING NOT LOWEST |
| 5 | L5₹2.5 Cr+₹28.6 L (13.1%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹2.5 Cr+₹28.6 L (13.1%) | L5 | Rejected-Finance BEING NOT LOWEST |
| Sl No | Description | Qty | Unit | M/s SK Traders L1 | Chakshu Enterprise L7 | Sukhi Electricals L9 | Shree Ayyappa Engineering L5 | cooltech engineering services L4 | SANJOLI CONSTRUCTION COMPANY L3 | M K ENGINEERS CO. L6 | UNITED ENGINEERING CORPORATION L2 | ARTI CONSTRUCTION L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully Copper/aluminium Sub main wiring of any size from surface/ concealed /existing conduit of any height and removing materials at site complete all as directed and directed by Engineer-in-Charge. | 11,637 | RUNNING METRE | 20 ₹2,32,740 | 35 ₹4,07,295 | 28 ₹3,25,836 | 30 ₹3,49,110 | 25 ₹2,90,925 | 11 ₹1,28,007 | 15 ₹1,74,555 | 10 ₹1,16,370 Lowest | 22 ₹2,56,014 |
| 2.00 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/ TPN DBs/ Main Switch including segegated of serviceable MCBs of SPN/SP keep in safe custody for reuse and old unserviceable MCCBs/ MCBs, Isolators, etc and removing at site complete all as directed and directed by Engineer-in-Charge. | 934 | EACH | 200 ₹1,86,800 | 225 ₹2,10,150 | 350 ₹3,26,900 | 300 ₹2,80,200 | 250 ₹2,33,500 | 11 ₹10,274 Lowest | 50 ₹46,700 | 25 ₹23,350 | 190 ₹1,77,460 |
| 3.00 | Material & labour for power point wiring using approved colour coding as per IS, with multistranded copper conductor using 4.0 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade, IS marked conforming to IS-694- 2010, drawn through in and including heavy duty, PVC concealed conduit of whitel/ivory colour including all accessories after chasing in wall etc, heavy duty ISI marked,with Gl sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, for 15 amps switch socket cobmination point including necessary running of 4.0 sq mm PVC insulated copper conductor FRLSH cable as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as directed and directed by Engineer-in-Charge.. (for AC Point) Note: Cutting chases in walls etc wherever required, Gl sunken box, Modular inner & outer plate etc shall be deemed to be included in quoted rate | 934 | POINT | 900 ₹8,40,600 | 625 ₹5,83,750 Lowest | 725 ₹6,77,150 | 750 ₹7,00,500 | 650 ₹6,07,100 | 900 ₹8,40,600 | 1,200 ₹11,20,800 | 850 ₹7,93,900 | 710 ₹6,63,140 |
| 4.00 | Supply & fix modular AC switch socket with single pole On/ OFF switch, three pin female socket 3 pin, male plug top suitable for 240 volts single phase supply complete all as directed and directed by Engineer-in-Charge. | 934 | EACH | 1,000 ₹9,34,000 | 950 ₹8,87,300 | 1,230 ₹11,48,820 | 1,500 ₹14,01,000 | 1,200 ₹11,20,800 | 700 ₹6,53,800 Lowest | 800 ₹7,47,200 | 770 ₹7,19,180 | 1,320 ₹12,32,880 |
| 5.00 | Material & labour for sub main wiring with approved colour coding as per IS with two runs of single core PVC insulated FRLSH cable with stranded copper conductor of size 6.0 Sq mm nominal area 1100 volts grade, IS marked conforming to IS-694- 2010 drawn through in and including PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of. PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as directed and directed by Engineer-in-Charge. Note:- Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable and one run of PVC heavy duty conduit will be measured as one unit | 11,637 | RUNNING METRE | 450 ₹52,36,650 | 625 ₹72,73,125 | 660 ₹76,80,420 | 550 ₹64,00,350 | 500 ₹58,18,500 | 501 ₹58,30,137 | 460 ₹53,53,020 | 412 ₹47,94,444 Lowest | 490 ₹57,02,130 |
| 6.00 | Supply & fix for sheet metal enclosure MCB DB TPN 04 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surtace to match with existing colour of wall complete all as directed and directed by Engineer-in-Charge. | 1 | EACH | 4,000 ₹4,000 | 3,500 ₹3,500 Lowest | 5,120 ₹5,120 | 5,000 ₹5,000 | 4,500 ₹4,500 | 3,900 ₹3,900 | 4,000 ₹4,000 | 4,500 ₹4,500 | 4,650 ₹4,650 |
| 7.00 | Supply & fix for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as directed and directed by Engineer-in-Charge. | 75 | EACH | 1,500 ₹1,12,500 | 1,320 ₹99,000 | 1,600 ₹1,20,000 | 1,750 ₹1,31,250 | 1,200 ₹90,000 Lowest | 1,600 ₹1,20,000 | 1,700 ₹1,27,500 | 2,269 ₹1,70,175 | 2,000 ₹1,50,000 |
| 8.00 | Supply & fix for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as directed and directed by Engineer-in-Charge. | 859 | EACH | 1,200 ₹10,30,800 | 1,380 ₹11,85,420 | 1,300 ₹11,16,700 | 975 ₹8,37,525 | 900 ₹7,73,100 Lowest | 1,300 ₹11,16,700 | 1,300 ₹11,16,700 | 1,695 ₹14,56,005 | 1,490 ₹12,79,910 |
| 9.00 | Supply & fix for MCB Tripple pole and neutral (TPN) rated capacity 40 Amps, 415 Volts breaking capacity 10 KA,'C' curve complete all as directed and directed by Engineer-in-Charge. | 1 | EACH | 1,000 ₹1,000 | 1,670 ₹1,670 | 2,000 ₹2,000 | 1,500 ₹1,500 | 1,500 ₹1,500 | 1,800 ₹1,800 | 100 ₹100 Lowest | 1,837 ₹1,837 | 2,500 ₹2,500 |
| 10.00 | Supply & fix for MCB Single pole and neutral (SPN) rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as directed and directed by Engineer-in-Charge. | 654 | EACH | 450 ₹2,94,300 | 425 ₹2,77,950 | 320 ₹2,09,280 Lowest | 400 ₹2,61,600 | 350 ₹2,28,900 | 480 ₹3,13,920 | 500 ₹3,27,000 | 600 ₹3,92,400 | 365 ₹2,38,710 |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
14 Jul 2026, 6:00 pmClosed
CWE (AF) Jodhpur
HQ CWE AF JODHPUR Opp Mosam Vibhag Airforce Chauraha , Ratanada Jodhpur (Raj)-342011
PROVN OF AC POINTS IN SMQs WITH ASSOCIATED UPGRADE OF ELECTRICAL INFRASTRUCTURE AT AFS JODHPUR
2026_MES_773180_1
89167/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) No 2 Jodhpur
as per NIT
8 documents required · 8 mandatory
₹2,000
GE (AF) No 2 Jodhpur
₹2.9 L
Yes
3 Aug 2026
18 Jun 2026
16 Jul 2026
18 Jun 2026
14 Jul 2026
9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully Copper/aluminium Sub main wiring of any size from surface/ concealed /existing conduit of any height and removing materials at site complete all as directed and directed by Engineer-in-Charge. | 11,637 | RUNNING METRE | - | - |
| 2 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/ TPN DBs/ Main Switch including segegated of serviceable MCBs of SPN/SP keep in safe custody for reuse and old unserviceable MCCBs/ MCBs, Isolators, etc and removing at site complete all as directed and directed by Engineer-in-Charge. | 934 | EACH | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
tender.pdf
Tender Documents • 4.72 MB
BOQ_865771.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .