Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC After deduction of Sch of Credit Rs. 1,56,598.00 | |
| 2 | L2₹29.8 L+₹28,273.55 (0.96%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L2 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S BHATT ENTERPRISES L2 | KRISHNA SAI ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exc 1.5mtr depth for laying pipe line/laying cable and getting out including trimming sides and forming bottom surface to the required level/slope etc. complete all as specified and directed | 207 | CUM | 200 ₹41,400 | 87 ₹18,009 Lowest |
| 2.00 | Removing excavated surplus soil l to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and directed. | 65.97 | CUM | 95 ₹6,267.15 | 68 ₹4,485.96 Lowest |
| 3.00 | Returning, filling in, tranches including spreading, levelling, watering and well ramming in hard/dense soil in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed. | 141.08 | CUM | 90 ₹12,697.2 | 48 ₹6,771.84 Lowest |
| 4.00Taking up or down existing GI steel water tubing of any grade including all GI fittings (such as bend, elbows, tees, connections, short pieces, back, nuts, unions, caps & plugs etc) laid in trenches or fixed on walls or on open surfaces complete all as specified and directed of the following sizes | |||||
| 4.01 | (a) 150 mm bore | 150 | RM | 35 ₹5,250 Lowest | 150 ₹22,500 |
| 4.02 | (b) 80 mm bore | 120 | RM | 20 ₹2,400 Lowest | 130 ₹15,600 |
| 4.03 | (c) 50 mm bore | 120 | RM | 15 ₹1,800 Lowest | 90 ₹10,800 |
| 4.04 | (d) 40 mm bore | 150 | RM | 10 ₹1,500 Lowest | 40 ₹6,000 |
| 4.05 | (e) 25 mm bore | 120 | RM | 8 ₹960 Lowest | 20 ₹2,400 |
| 4.06 | (f) 20 mm bore | 120 | RM | 5 ₹600 Lowest | 10 ₹1,200 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Jul 2025, 6:00 pmClosed
CWE (HILLS) PITHORAGARH
HQ CWE (HILLS) PITHORAGARH POST OFFICE - BHARKATIA DISTRICT - PITHORAGARH STATE - UTTARAKHAND PIN 262520
CA NO. CWE/HILLS/RKT/31 OF 2025-2026 REPAIR/MAINT OF EXTERNAL WATER SUPPLY SYSTEM AND EXTERNAL ELECTRIFICATION OF ENTIRE AREA OF CHAUBATTIA UNDER GE RANIKHET
2025_MES_717793_1
89223/25-26/E8
Open Tender
Civil Works
Item Rate
120 days
CHAUBATTIA
Class - D
9 documents required · 9 mandatory
₹500
GE (MES) RANIKHET
₹70,000
Yes
18 Sept 2025
1 Jul 2025
5 Aug 2025
1 Jul 2025
29 Jul 2025
15 Jul 2025
Amount
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exc 1.5mtr depth for laying pipe line/laying cable and getting out including trimming sides and forming bottom surface to the required level/slope etc. complete all as specified and directed
Removing excavated surplus soil l to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and directed.
Returning, filling in, tranches including spreading, levelling, watering and well ramming in hard/dense soil in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed.
Taking up or down existing GI steel water tubing of any grade including all GI fittings (such as bend, elbows, tees, connections, short pieces, back, nuts, unions, caps & plugs etc) laid in trenches or fixed on walls or on open surfaces complete all as specified and directed of the following sizes
(a) 150 mm bore
(b) 80 mm bore
(c) 50 mm bore
(d) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
S & F Steel water tubing medium grade galvanised with all GI fittings (such as bend,elbows,tees, connections, short pieces, back, nuts, unions, caps & plugs etc) laid in trenches or fixed on walls or on open surfaces complete all as specified and directed of the following sizes
(a) 150 mm bore
(b) 80 mm bore
(c) 50 mm bore
(d) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
Taking out old unserviceable gun metal, globe or gate valve including S & F gun metal, globe or gate valves ISI marked class-I, with iron wheel head, screwed both ends, for iron pipe complete all as specified and directed of the following size :-
(a) 50mm bore (Nominal bore)
(b) 40mm bore (Nominal bore)
(c) 25mm bore (Nominal bore)
(d) 20mm bore (nominal bore)
(e) 15mm bore (nominal bore)
Taking out old U/S sluice valve for replacement including, supplying, testing and commencing of sluice valve of cast iron body flanged and drilled as per ISI 14846 (ISI Marked) specifications PN-1.6 with stainless nuts, bolts, washers & fibre/rubber gasket steel spindle all as specified and directed of the following size :-
(b) 150mm bore (Nominal bore)
(c) 100mm bore (Nominal bore)
(d) 80mm bore (Nominal bore)
Disconnecting of existing NRV and supplying installation, commencing, connecting and testing of cast steel Non Return Valve, class 300 ASA, flanged and drilled both ends with gun metal seat and making bypass arrangement flanged type complete with & including flanges, fibre sheet gasket, nut-bolts & washers complete all as specified and directed of the following size :-
(a) 150 mm bore
(b) 100mm bore
(c) 80mm bore
Taking up or down existing GI steel water tubing of any grade including all fittings and accessories from trenches/open surfaces, tanks including cleaning ,re-threading the old threads, cutting, welding work, etc as required and re-fixing the same after necessary repair works, etc as required , including new GI fittings and accessories as required in new or old position including necessary excavation work complete all as specified and directed of the following size :-
(a) 100/150mm bore (Nominal bore)
(b) 80mm bore (Nominal bore)
(c) 50mm bore (Nominal bore)
(d) 40mm bore (Nominal bore)
(e) 25mm bore (Nominal bore)
M & L for cleaning of Nagpani pump house and its surrounding by removing grass, shrubs, fungus, algee including cleaning of valve pit chambers within the boundary of the installation/pump house complete all as specified and directed.
M & L for cleaning of Highest point pump house and its surrounding by removing grass, shrubs, fungus, algee including cleaning of valve pit chambers within the boundary of the installation complete all as specified and directed.
M & L for construction of brick masonry valve pit size 610x610x610mm (internal dimensions) including demolition of old valve pit chamber with following specifications complete all as specified & directed by Engineer-in-Charge: (a)Excavation in any type of soil including disposal of excavated earth to a distance not exceeding 100m, (b) 150mm thick PCC 1:4:8 type D-2 in foundation, (c) 230 mm thick brick work using old size bricks as in walls in CM 1:4, (d) 15mm thick internal plaster in CM 1:4, finished even and smooth without using extra cement. (e) 3.15 mm thick MS sheet cover including 40 x 40 x 6mm MS angle frame and hold fast including handles, hinges & with locking arrangement, (f) Two coats of black bituminous paint over a coat of red oxide primer on steel & iron surfaces.
M & L for construction of brick masonry valve pit size 1050x1050x900mm (internal dimensions) including demolition of old valve pit chamber with following specifications complete all as specified & directed by Engineer-in-Charge: (a)Excavation in any type of soil including disposal of excavated earth to a distance not exceeding 100m, (b) 150mm thick PCC 1:4:8 type D-2 in foundation, (c) 230 mm thick brick work using old size bricks as in walls in CM 1:4, (d) 15mm thick internal plaster in CM 1:4, finished even and smooth without using extra cement. (e) 3.15 mm thick MS sheet cover including 40 x 40 x 6mm MS angle frame and hold fast including handles, hinges & with locking arrangement, (f) Two coats of black bituminous paint over a coat of red oxide primer on steel & iron surfaces.
M & L for repairs to existing leaking joints (flanged/socketed/collar) upto 50 mm bore GI pipe line including supply and replacement of flanged/socket/union /reducer etc with and including all necessary GI nut bolts, fibre/rubber gasket sheet and welding work wherever required, to make the joints leak proof including necessary cutting threading etc, including necessary excavation work complete all as specified and directed.
M & L for repairs to existing leaking joints (flanged/socketed/collar) for 80 mm bore GI pipe line including supply and replacement of flanged/socket/union /reducer etc with and including all necessary GI nut bolts, fibre/rubber gasket sheet and welding work wherever required, to make the joints leak proof including necessary cutting threading etc, including necessary excavation work complete all as specified and directed.
M&L for repairs to existing leaking joints /flanged /socket/ collar for 100mm/150mm dia GI pipe line including replacement of flanged/socket/union/reducer etc with and including all necessary nuts, bolts, fibre/rubber insertion sheet and welding wherever required, to make the joints leak proof including necessary cutting, threading etc, including necessary excavation work complete all as specified and directed.
Complete cleaning of pressed steel/iron water storage tank from inside, extraction of all mud/sand/dust/Algee deposits, making it free from algee growth by scrapping & washing with water & painting with two coat of black bituminous paint on all the MS items fitted inside the paint on complete external surface of tank and staging / supports etc, inlet/outlet water pipe complete all as specified for the following :-
(a) 80,000 gallons capacity at Nagpani
(b) 38,000 gallons capacity at highest point.
(c) 20,000 gallons capacity at Nagpani.
(d) 8000 litre capacity to 32000 litre capacity at Chaubattia.
Complete cleaning of masonary water storage reservoir from inside, extraction of all dust/sand/mud/Algee deposits, making it free from algee growth by scrapping with brush, washing with water cleaning of all MS /iron/wooden frame work inside and roof of the reservoir & general cleanliness of the outside surface/area surrounding of the all plastered internal surface (excluding floor) of the tank and treatment with bleaching powder on the tank floor after cleaning & applying two coats of approved make & shade of snowcem on all sides of the tank & two coats of approved make & shade of snowcem of all sides of the outside of the tank including necessary painting with one coat of black bituminous paint on all steel /iron frames/angles of tank over black paint of size 2.5 fit x 1.5 fit including marking of tank capacity and date etc of cleaning. The entire Job is to be carried out all as specified and directed for the following reservoirs/tanks :-
(a) 5 lacs gallons capacity at Chaubattia
(b) 3 lacs gallons capacity at Chaubattia
(c) 42,000 gallons capacity at Highest point
(d) 50,000 gallons capacity at Chaubattia
Supply and fixing in repair for coupling male and female with shaft alignment for pumping set 100HP size as per existing make /sample.
Supply and fixing in repair for pump bearing for 100 HP pumping set pump as per existing make/sample.
Supply and fixing in repair for pump bearing for 75 HP pumping set pump as per existing make/sample.
Supply & fix in repair for 4 mm thick fibre sheet complete all as specified and directed.
Supply & fix in repair for 6 mm thick fibre sheet complete all as specified and directed.
Supply & fix in repair for 12 mm thick fibre packing sheet used in GI tubing connections complete all as specified and directed.
M&L for connecting copper lugs 50 to 95 Sqmm with incoming & outgoing feeder starter to motor connector complete all as specified and directed
Supply and fixing coupling rubber washer as per sample complete all as specified and directed
Supply & fix Copper finger suitable for Oil immersed starter 100 HP complete all as specified and directed.
Supply & fix Copper gutka suitable for Oil immersed starter 100 HP complete all as specified and directed.
M&L for PVC insulated unsheathed copper conductor 1100 V industrial cable 50 sqmm Multi-stranded single core, including connecting with copper lugs 50/95 Sqmm with incoming & outgoing feeder starter to motor connector including taking down old cable complete all as specified and directed
Supply & Fixing in repair for Heating Element copper sheathed and nickel plated 1500 Watt triangular type complete all as specified and directed.
Supply & Fixing in repair for Heating Element copper sheathed and nickel plated 2000 Watt triangular type complete all as specified and directed.
Supply & Fixing in repair for Heating Element copper sheathed and nickel plated 2000 Watt cup type complete all as specified and directed.
Supply & Fix Thermostat with temperature autocut, 240 volt for water heater, complete all as specified and directed.
M & L in replacement for connecting and testing of CI air release valve 50 mm size with ISI marked flanged type incl jointing material such as fiber board, nut bolt, washers, and welding etc complete all as specified and directed.
M & L in replacement for connecting and testing of CI air release valve 40 mm size with ISI marked flanged type incl jointing material such as fiber board, nut bolt, washers, and welding etc complete all as specified and directed.
Taking out old U/S Water level indicator and supply and fixing FRP scale conventional / Mechanical water level indicator complete with float, wire, float guide pipe , bracket & pulley, counter weight, indicator pin, etc including all accessories all as specified and as directed.
Supply and fixing water testing solution O-TOLODINE bottle 500 ML complete as directed and as approved by Engnr-in-Charge.
Collecting samples of under ground sump water from chaubattia UG Sump 5 lacs, 3 lacs, Highest point pump house for Bacteriological testing and complete Chemical testing for parameters for raw & treated water as specified. Note : The bacteriological and chemical testing of water shall be carried out in Govt authorised laboratory . The item cost includes collecting of samples of water from UG sump and Pump house site and charges of Govt authorised laboratory for carrying out testing of water sample.
Supply & Fixing galvanised iron ISI marked heavy duty drilled flanged suitable for 80 mm bore pipe line complete all as specified and directed.
Supply & Fixing galvanised iron ISI marked heavy duty drilled flanged suitable for 100 mm bore pipe line complete all as specified and directed.
Supply & Fixing galvanised iron ISI marked heavy duty drilled flanged suitable for 150 mm bore pipe line complete all as specified and directed.
Supply and fixing nuts, bolts and washer for pumping set 12.5/40/75/100HP size as per sample complete all as specified and directed.
S & F mild steel framed work such as grills, gratings etc with ends of bars soldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, mokey caging, and similar work con- forming to Fe.290.Gde-E-165complete all as specified and directed.
Material & Labour for preparation of existing old untreated CGI/PGI sheet roof surface of any description not otherwise described over 10 cm width or girth by cleaning , removing dust and including washing and cleaning etc to receive painting and making good with red lead wherever required and applying two coats of roof paints (Coptic of Jenson & Nicholson or Antisol of Berger or equivalent make as specified in appendix A of particular specification ) complete all as specified and directed.
M & L for preparation of old painted surface of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete as specified and directed.
M & L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high on existing iron/steel surfaces complete as specified and directed.
Material and Labour for repair to electrically driven centrifugal pump set (75/100 HP motor-pump set) including servicing, cleaning, and replacement of water body, kit seal cup, screw ring retainer and burnt out nut, bolts etc of any size and capacity complete all as specified and directed
Material and labour for chart/ poster/ diagram / name plate etc made out of perpex sheet 2 mm thick, of size 2 m x 1.5 m cut to size and shape with colour background and diagram and letters including fixing arrangement with screws / adhesives as required complete all as specified and directed by Engineer in charge. Note: The content and size of chart/ poster /diagram / name plate etc shall be given by the Engr in charge during execution of work.
M&L for notice board of size 50x20 cm and written as "OUT OF BOUND FOR ALL RANKS", made from 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures in signal red colour and fixed with MS clamps, bolt and nuts of approved size complete all as specified and directed.
Supply and erecting in true vertical position steel tubular poles 9 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-31 with and including painting of poles with black bituminous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed.
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed.
M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed.
M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work complete all as specified and directed.
M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M & L for Aluminium conductor, steel reinforced, overhead conductor (ACSR) including stringing, stretching and strengthening existing LT steel tubular pole including binding and jointing the conductor complete all as specified and directed. Type and Size of ACSR Conductor - (Weasel) 6/1 x 2.5mm aluminium and 1x2/59 steel
S&F shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75mm height and 90mm dia for working pressure 1100 volts, LT complete with insulator bolts, washers and nuts complete all as specified and directed.
S & F stay assembly comprising GI stay bow 400 X 14 mm, GI steel stay rod 1800 mm long X 16 mm dia with nut-bolts, washers, GI steel plate 230 X 230 X 6 mm, two Nos. thimble, loop insulator of size 65 X 90 mm clearance of hole 16 mm, stay wire of GI stay strand of size 7 X 3.15 mm fixed to stay assembly and stay clamps including necessary excavation and earth work in hard / dense soil, PCC 1:3:6 type C-2 block complete all as specified and directed.
M&L for stringing, stretching and strengthening of GI wire 4mm dia on LT electric lines including binding, jointing etc all as specified.
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 40mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Supply, laying, jointing and commissioning LT XLPE 1100 volts grade as per IS 7098 heavy duty cable PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes,induct, on pole and roads etc of following sizes :-
(a) 120 Sqmm 3.5 core
(b) 95 Sqmm 3.5 core
(c) 70 Sqmm 3.5 core
(d) 50 Sqmm 3.5 core
(e) 25 Sqmm 4 core
(f) 16 Sqmm 4 core
(g) 16 Sqmm 2 core
(h) 10 Sqmm 2 Core
Taking out unserviceable LT cable of any type and size from pole/wall/trenches by disconnecting electric connections for repair / replacement of cable complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. Note : Punned thickness shall be measured and paid.
M&L for brick protection covers laid over cables of sub class'B' bricks old size (230X115X75)mm all as specified and directed.
S&F plastic (moulded poly propeline) line phase separators for separating 5 Nos of over head line conductors length 1200mm with 25mm with fly nuts and clamps suitable for 1100 volts grade LT electric lines of any size fixed with over head electric lines all as specified and directed.
Tightening / re-stringing of existing loose / broken ACSR conductor / copper conductor or any other type of conductor of any sizes and strengthening as required at site complete all as specified and directed.
M&L for GI pipe light grade with all fittings fixed to pole and laid to floor/ground for mechanical protection of cable of the following sizes :-
(a) 80mm bore
(b) 50mm bore
(c) 40mm bore
(d) 25mm bore
Dismantling of existing LT pole any size/type from foundation in necessary earth work including dismantling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed.
Dismantling of existing stay assembly any type/size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed.
Dismantling/taking out old ACSR/copper conductor/GI wire any size from existing over head lines incl disconnection all as specified and directed.
Dismantling/taking out insulator of any size/type from existing electric LT lines all as specified and directed.
Dismantling/ taking out street light fitting any type/capacity complete with bracket all as specified and directed
M & L for one coat of aluminium shade paint of approved quality including preparation of existing old painted surface of steel tubular poles LT complete including flat iron clamps, bracing , cross arms etc and numbering of poles with white synthetic enamel paint over a circular painted base and strip marking paint up to a height of 5 feet with black & yellow five bands with synthetic paint (strip of 1 feet height each) complete all as specified and directed.
Supply & Fixing LED street light fitting 30 W pressure die cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver including GI bracket light grade 25/32mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 2.5 core complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings.
Supply & Fixing LED street light fitting 45 W pressure die cast aluminium IP66 roadway luminaire with operating range from 80V AC to 440 V AC with high power LED as light source and electronic driver including GI bracket light grade 25/32/40 mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 2.5 core complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings.
Supply & Fixing LED Flood light fitting 100 W 230 V AC outdoor type pressure die cast aluminium IP66 luminaire with high power LED as light source and electronic driver with impact and corrosion resistant including clamp and GI bracket light grade and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 4sqmm core complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings.
Taking down old U/S junction box and Supply and fixing Junction Box made up of High quality thermoplastic polycarbonate enclosure with IP 65 degree of protection, weather proof, corrosion proof, dust proof, insulted and shock proof, fire retardant non toxic material with internally embedded gasket with 10 Amp MCB and 4 nos terminal of size 200x160x98 mm complete all as specified and directed by Engineer-in-Charge.
Taking out old U/S service connection cable for replacement including S&F service connection cable, 1100 volts grade heavy duty PVC insulated aluminium conductor, 16 Sqmm 2 core size, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
S & F MCCB 415 Volts, 4 pole, adjustable type, 100 Ampere with breaking capacity 36 KA complete all as specified and directed
S & F MCCB 415 Volts, 4 pole, adjustable type, 200 Ampere with breaking capacity 36 KA complete all as specified and directed
S & F MCCB 415 Volts, 4 pole, adjustable type, 250 Ampere with breaking capacity 36 KA complete all as specified and directed
S & F on pole / wall Nature switch 02 EC with enclosure factory made suitable for 8 KW street light load single phase 240 volts and power contactor rating 40 Ampere with MCB 63 Ampere contactor and terminal block confirming to IEC – 60947 – 4 – 1 / IS – 13947 – 4 – 1 (Sensor alongwith pre-dawn switching off timer, 4 – 8 hours) infrared sensor based switch for intelligent outdoor street light control model No. SWADEEP – 02EC8kW1P, Make – KAKATIYA ENERGY SYSTEMS LTD. Or its equivalent approved make complete with and including mounting bracket, cable glands, openable doors with lock complete all as specified and directed.
M&L for trimming of tree branches around LT/HT over head line complete removed upto 1.0 mtr distance from over head line complete all as directed by Engr-in-Charge.
S & F guard cradles, make to shape, hexagonal / rectangular or any other shape as required and directed, fabricated out of 4 mm dia GI wire including 14 SWG binding wire complete all as specified and directed.
Supply and Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
S&F synthetic insulating mat near electric installations of size 2m x 1mX 3mm as specified and directed.
All as per item no 89 above but of size 2m x 1m x 2.5 mm.
Supply & Fix in replacement for ELECTRIC SHOCK CHART (Electric shock & its management chart) of standard size 70x50 cm drawn on wooden/ cardboard frame of approved size complete all as specified and directed.
Supply, fabricating and fixing of sheet metal enclosure made of 16 gauge MS sheet outdoor type of suitable size including fixing of MCCB of cap 200 Amp, 415 Volt,50Hz, 4 pole, 36 KA, AC supply with 300 Amp rated busbar on porcelain insulators for neutral link double door type with locking arrangement complete with MS angle iron frame of size 25 x 25 x 5mm with nut/bolts and PCC platform work including painting with two coat of synthetic enamelled paint over one coat of red oxide/ primer complete all as specified and directed at site.
All as per item No 92 here in before but Cap of MCCB 100 Amp, 4 pole, 415 volt, 50 Hz, 25 KA, AC supply,
M&L for testing of existing earthing sets and writing the resistance value (in ohm) clearly above the earthing pits after complete cleaning of earthing chamber, removal of near by vegetation and applying one coat of distemper/whitewash over the pit covers complete all as specified and directed
Surface dressing n.exc 15 cm deep incl as in any type soil including taking out all sapling shrubs, brushwood, undergrowth, roots, and trees n. exc 30 cm girth all removing to a distance n.exc 100 m from starting point complete all as specified and directed by Engr-in-charge (The area is to be carried out in and around,structches viz transformes, substations around power house and other E/M installation complete all as specified and directed
Supply & Fix aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Supply and fix air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
Supply and fix of Earth Enhancement Compound ( 6kg of Bucket) for recharging existing earthing sets and complete testing of earthing after repair and obtaining the desire earth resistance complete all as specified and directed.
M/S BHATT ENTERPRISES (BID ID -3366335)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .