Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC H NO 02 BALLUPUR ROAD DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹21.4 L Quoted ₹21.8 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹22.8 L+₹1.0 L (4.64%)Rejected-AOC 0 0 NAGLA MALOO MOHAMMDABAD FARRUKHABAD FARRUKHABAD FARRUKHABAD UTTAR PRADESH 209625 | FARRUKHABAD | UTTAR PRADESH | 209625 | ₹22.8 L+₹1.0 L (4.64%) | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹24.6 L+₹2.8 L (13.0%)Rejected-AOC | ₹24.6 L+₹2.8 L (13.0%) | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 4 | L4₹24.7 L+₹2.9 L (13.4%)Rejected-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | ₹24.7 L+₹2.9 L (13.4%) | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 5 | L5₹26.1 L+₹4.3 L (19.9%)Rejected-AOC | ₹26.1 L+₹4.3 L (19.9%) | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹40.8 L
EMD Value
₹81,600
Closing Date
22 Jun 2024, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVISION OF CAR PARKING FOR TYPE D D1 TO D4 BLOCK AT DRDO RESIDENTIAL COMPLEX SANCHAR VIHAR DEHRADUN
2024_MES_657292_1
GE(I)RND/9365/E8/24-25
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Class D Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹81,600
Yes
31 Aug 2024
1 Jun 2024
24 Jun 2024
1 Jun 2024
22 Jun 2024
15 Jun 2024
1 Jun 2024 - 15 Jun 2024
Amount
Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil etc complete all as specified and directed.
Excavating in trenches, in any type soil not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers n. exc. 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material soil n exc 50m & depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Removing excavated material soil exc 250m but not exceeding 500m & depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M&L for cement concrete 1:5:10Type E-2 using 40 mm graded crushed stone aggregate in foundation filling sub base and mass concrete complete all as specified and directed.
M&L for cement concrete 1:4:8 Type D-2 using 40 mm graded crushed stone aggregate in foundation filling sub base and mass concrete complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Taking down chowkats or frame of any description exc 1.5 Sqm each and n.exc 4.0 Sqm (without taking off shutters from the frames) & remove off the premises complete all as specified and directed.
S&F, M.S Plates (plain or chequered) Fe-290 (Gde- E- 165) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S&F, M.S work as in Roof trusses (framed) Fe 410-W (Gde -E-250) quality-A, trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle channel or flat sections) including distance pieces cleats etc. complete all as specified and directed.
S&F 11 to 15mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other end, or screwed both ends, each screwed and to fitted with washers and one hexagonal or square nut exc 10 cm and n exc 15 cm complete all as specified and directed.
M&L for Bands, straps, rungs, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete as specified and directed.
M&L for Pre-painted galvatume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa it shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm /sqm of coating (total both surfaces) as in roof covering /cladding to wall, fixed with self tapping screws neeoprene and EPDM washers complete all as specified and directed.
M&L for Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa it shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm /sqm of coating (total both surfaces) as in roof covering /cladding to wall, fixed with self tapping screws neeoprene and EPDM washers complete all as specified and directed.
M&L providing 100mm thick PCC (cement concrete) 1:2:4 etc type C-2 (using 20 mm graded stone aggregate ) pavement/ramp/floor finsihed fair and event complete all as specified and directed.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc.of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 finished fair and even without using extra cement complete all as specified and directed.
M&L for Preparing newly plastered surfaces of walls and applying two coat of cement base paint complete all as specified and directed.
M & L preparation of new or previously untreatedy steel surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000 M complete all as specified and directed
Demolition of plain cement concrete (Un reinforced ) PCC paver block of any description in any position not otherwise specifically provied and removal and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
Demolition of ( reinforced cement concrete) (reinforcement cut as required to facilitiate demolition) of any description and in any positionnot otherwise specifically provided for and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as complete all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 25 mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly for One light point controlled by one switch. complete all as specified and directed.
S&F ceiling roses with ceiling rose 3 plates polycarbonate body complete all as specified and directed.
S&F in replacement of UNSV MCB TPN with MCB TPN 'C' Curve 63 Amp suitable for fixing in TPN DB 415V 4 way,6 way and 8 way complete all as specified and directed.
S&F LED 20W complete batten fitting, efficacy: 100 lumen/watt with all as accessories complete all as specified & directed. Make: LCTLN-20-CDL of Crompton or equivalent in Havells/Philips.
S&F in replacement sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable of size 2x6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x6 Sqmm as earth continuity conductor complete all as specified and directed. Make of cable: Havells/Polycab/L&T, Make of conduit: Finolex/Polycab/Supreme
S&F in replacement MCB distribution board SPN double door, 240 volts, 4 ways, powder coated, CRCA steel sheet constructed as per IS : 8623-1 &3, degree of protection IP 54-IK-09 Indoasian Cat part No 811824 or equivalent in havells/ Legrand without busbar complete all as specified & directed.
S & F MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete all as specified & directed. Make- Indoasian/Havells/Legrand as approved.
Taking down carefully (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custordy or for taking credit (credit for above items should be taken as per conditions separately) etc complete all as specified & directed.
V S ENTERPRISES
M.K Engineers
M/S WASEEM KHAN CONTRACTOR
Amit Associates
M/s Sagar Associates
Aron Water Proofing and Pest Control
SANJEEV CONSTRUCTIONS
M/s Arora Sales Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .