| 2 | Admitted-Finance VPO MANDHER TEHSIL BAIJNATH DISTT KANGRA HIMACHAL PRADESH | MANDI | HIMACHAL PRADESH | 175013 | Admitted-Finance |
| 3 | Admitted-Finance VILL P O PAROUR TEHSIL PALAMPUR DISTT KANGRA H P | KANGRA | HIMACHAL PRADESH | 176001 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹16.5 L
EMD Value
₹32,200
Closing Date
19 Sept 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
District Project Manager
District Project Manager O/o DPMU HPCDP JICA ODA Phase-II, Opposite to Soil Testing Lab, Holta at Palampur
C/o of Incubation Room at Shitake Cultivation and Training Centre, CSKHPKV-Palampur, Tehsil- Palampur, Distt.- Kangra (H.P)
2023_HPCDP_78171_1
No.AGR. DPMU. KGR. F (7)Tender/13/2022-Vol-I- 1027
Open Tender
Civil Works
Item Rate
60 days
SCTC CSKHPKV-Tehsil- Palampur, Distt.-Kangra HP
Please refer Tender documents.
14 documents required · 14 mandatory
₹1,500
District Project Manager HPCDP JICA ODA
₹32,200
District Project Management Unit HPCDP JICA ODA
10 Oct 2023
30 Aug 2023
20 Sept 2023
30 Aug 2023
19 Sept 2023
30 Aug 2023
5 Sept 2023
Amount
Excavation in foundation trenches etc in earth work in all kinds of soil such as picjk work/ jumper work, blasting/chiselling/wedging out of soft/hard rock including pumping and belling out water and stacking the ecavated soil from the edge of the excavation and then returning the staked soil in 15cm layers foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth in al leads and lifts through manuaally and mechanical means and as directed by engineer in charge.
Providing From work with steel plates 3.15mm. thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish of Water proof plywood including centering, shuttering, strutting with wooden batten & ballies, height of proping and centring below supportin floor to ceiling . And removal of the same for insitu reinforced concrete and plain concrete work including carriage of material in all leaad and lift and heights complete as per the direction of Engineer in Charges.
In Column footing
In beams, cantilever & lintels
Providing and laying cement concerte 1:4:8 (1 cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in Foundation and Plinth including carriage of material in all lead and lifts complete as per the direction of Engineer in Charges.
Providing and laying cement concrete 1:1.5:3 (1 cement: 1.5: sand: 3:graded stone aggregate 20mm normal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in footings bases of columns including carriage of material in all lead and lift and upto all heights complete as per the direction of Engineer in Charges.
Providing and laying cement concrete 1:1.5:3 (1 cement: 1.5: sand: 3:graded stone aggregate 20mm normal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work including carriage of material in all lead and lift and upto all heights complete as per the direction of Engineer in Charges.
in columns
in beams, slabs and lintels
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete as per the direction of Engineer in Charges.
Providing mild steel/Tor Steel reinforcement for R.C.C. work including bending, binding also cost of Binding wire and placing in position complete upto all floor level including carriage of material in all lead and lift complete as per the direction of Engineer in Charges.
Second class brick masonary in common burnt clay building bricks in superstructure in Cement Mortar 1:4 (1cement: 4 sand) including carriage of materials in all lead, lift and upto all heights complete as per the direction of Engineer in Charges.
Providing and laying hand packed kharuanja stone soling including carriage of material upto all leads and lifts complete as per the direction of Engineer in Charges.
Providing and fixing 0.60mm (zero point sixty millimeter) thick pre-painted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified poly ster (RNP) organic coating of 20 (twenty) microns over 5 (five) microns primer coating to back coat of polyester of 5microns over 5 microns primer coating including fixing with pre-painted iron Jor L hooks, bolts and nuts 6mm ( six milimeter) dia metre with pre-painted limpet and rubber washers complete with all accessories.as per HP.PWD specification 1990 (One thousand Nine hundred Ninety) Volume-I, including carriage of all labour equipments and materials to various location through all modes of transportation in all leads and lifts , including all incidental charges complete in all respect as per direction & entire satisfaction of Engineer incharge.
Steel work welded in built up sections, trusses and framed work, including cutting, welding, hoisting in all heights and levels, fixing in position and applying a priming coat of red lead paint complete:-In gratings framed guard bars, ladders, railing, brackets and similar class workas per HP.PWD specification 1990 (One thousand Nine hundred Ninety) Volume-I, including carriage of all labour equipments and materials to various location through all modes of transportation in all leads and lifts , including all incidental charges complete in all respect as per direction & entire satisfaction of Engineer incharge.
Providing and fixing 15 cm. wide 45 cm. overall semicircular plain G.I. sheetgutter with iron brackets 40x3mm size bolts and nuts and washers etc. including making necessary conections with rain water pipe complete as per design.0.63mm thick sheet.
Providing and fixing M.S. BP sheet 1.66mm(one point sixty six milimeter) to 2mm(two milimeter) thick in eaves board/facia/soffits/ceiling including cutting fixing and welding to steel roof members and applying a coat of red lead primer complete as per instruction of Engineer-in-Charge (Base members of steel work shall be measured & paid separately).as per HP.PWD specification 1990 (One thousand Nine hundred Ninety) Volume-I, including carriage of all labour equipments and materials to various location through all modes of transportation in all leads and lifts , including all incidental charges complete in all respect as per direction & entire satisfaction of Engineer incharge.
Providing and fixing 5 ( five) mm thick Asbestos Cement board / AC cement sheet ceiling of approved quality with butt jointing and wood screws (frame work and cover fillets to be measured and paid for separately) as per H.P. PWD. Spesification 1990 (One thousand Nine hundred Ninety) Volume-1 (One), including carriage of all labour, equipments and materials to various locations through all modes of transportation in all leads and lifts, including all incidental charges complete in all respect as per direction & entire satisfaction of Engineer incharge.
Providing and fixing ridges or hips 60 cm overall with 0.60mm thick prepainted steel sheets in roofing with hot dipped metalic zinc coated sheets with top coat of regular modified polyster organic coating of 20 microns over 5 microns primer coating + back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts & nuts 6mm dia & prepainted G.I. limpet and bitumen washers complete with all accessories as required as per the direction of Engineer in Charges.
15 mm cement plaster in single coat on rough side of brick/stone masonry for interior plastering up to floor two level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth . in CM1:4 complete within all leads and lifts as per the direction of Engineer in Charges.
Supplying and fixing rolling shutters of approved make made of 80mm x 1.25mm M.S. laths interlocked together through their entire length and joined together at the end by end locks mounted on specially designed pipe shaft, with brackets side guides and arrangements for inside and outside locking with push pull operation complete but excluding the cost of the top cover and springIncluding carriage of material in all lead and lifts complete with all accessories as required as per the direction of Engineer in Charges.
Shutters having width below 3.5 meters complete with all accessories as required as per the direction of Engineer in Charges.
Providing and fixing top cover of rolling shutters complete with all accessories as required as per the direction of Engineer in Charges.
Providing and fixing 27.5 cm long wire spring grade no.2 for rolling shutters Including carriage of material in all lead and lifts complete with all accessories as required as per the direction of Engineer in Charges.
Providing and fixing ball bearing for rolling shutters Including carriage of material in all lead and lifts complete with all accessories as required as per the direction of Engineer in Charges.
Applying Birla wall care putty over plaster surface after throughly brushing the surface free from mortar drops , dust, loose materials and other foreign matters and papered smooth to give final matter finish to the surface completeIncluding carriage of material in all lead, lifts upto all heights omplete as per the direction of Engineer in Charges.
Distempering two coats with oil bound washable distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth priming coat with distemper primer.including carriage of material in all leads, lifts and height complete as per the direction of Engineer in Charges.
Applying priming coat over new steel & other metal surfaces after & including preparing the surface by thoroughly cleaning oil grease dirt and other foreign matter and scoured with wire brushes fine steel wool scrapers and sand paper complete. With ready mixed priming paint brushing red lead,Red-oxide/zincoxide chrome complete as per the direction of Engineer in Charges. .
Painting two coats (excluding priming coats on new steel and other metal surfaces with enamel paint brushing to give an even shade including cleaning the surface of all dirt,dust and other foregin matters Enamel paint other than white complete as per the direction of Engineer in Charges.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group C.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and fixing bakelite batten/angle holder including connections etc. as required.
Supplying and fixing metal box of 100mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. Cat-A.
63 Amps. Cat-B.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Single door-12 way
Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps. Cat-A.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 6 sq. mm (twin core)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-
Ceiling Fan 1400 mm sweep, Category-A
Providing and fixing shock proof slim decorative extruded fixture with domestic electronic ballast, suitable for 36 watt FTL (T8), complete with all accessories (including the T-8 Tube), connections, testing and commissioning etc. as required.
1 x36 watt-FTL(T8) (Category-A)
Supplying and fixing of surface/recess mounting ceiling fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required.
Ceiling fitting, surface type (Category-A)
Sahil Sharma
Rakesh Kapoor
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .