Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-Finance | L1 | Accepted-Finance Accepted | |
| 2 | L2₹27.7 L+₹6.9 L (33.3%)Rejected-Finance A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | L2 | Rejected-Finance Rejected due to bidder not L1 | |
| 3 | L3₹28.5 L+₹7.8 L (37.3%)Rejected-Finance 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | L3 | Rejected-Finance Rejected due to bidder not L1 |
| Sl No | Description | Qty | Unit | Shree Krushna Supply Corporation L3 | PARTH CONSULTANCY L1 | JYOT ENTERPRIES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Labour only with all necessary T&P etc for attending day to day complaints of summer appliances including taking out and replacing of defective components of window / split type air conditioners of any capacity through minimum one skilled mechanic and one helper complete all as specified and directed
Note:-
(i) Spare parts/components required for replacement shall be measured and paid for separately at supply only rates under respective item of BOQ.
(ii) The contractor shall be imposed a penalty at the rate of Rs 500/- per day for each complaint pending for more than 24 Hrs. | 800 | Each Job | 160 ₹1,28,000 | 131 ₹1,04,800 Lowest | 170 ₹1,36,000 |
| 2.00 | Removing defective window/Split type air conditioner of any make and capacity from various locations and transporting to contractor workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and to replace un-serviceable spares parts and re-fixing at various locations after repairing including testing on load at site complete all as specified and directed
(All spares compressor, fan motor, relay, capacitor, over load, shall be measured and paid separately under supply only item) | 10 | Each Job | 220 ₹2,200 | 188 ₹1,880 Lowest | 500 ₹5,000 |
| 3.00 | Removing unserviceable burnt sealed compressor from Air conditioner and fixing only new rotary compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed
Note:- i) Rotary compressor shall be measured and paid separately under supply only item)
ii) If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate. | 15 | Each Job | 1,300 ₹19,500 | 1,125 ₹16,875 | 500 ₹7,500 Lowest |
| 4.00 | Taking out Window/Split type Air conditioner of any make and capacity from position and cleaning the complete cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner checking of blower motor, electrical connection and re-fixing the same on its original position and testing complete up to satisfaction complete all as specified and directed
(If any spare is required to replaced the same to be measured and paid separately under supply only item) | 100 | Each Job | 350 ₹35,000 | 300 ₹30,000 Lowest | 500 ₹50,000 |
| 5.00SUPPLY ONLY ITEM Note : i) The element of fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas. | ||||||
| 5.01 | New Rotary type compressor of Capcity 1.5 TR
MAKE : Kirloskar/Tecumesh/Carrier / Hitachi / Blue Star /LG/ samsung | 10 | Each | 8,000 ₹80,000 | 6,375 ₹63,750 | 4,999 ₹49,990 Lowest |
| 5.02 | New Rotary type compressor of Capcity 2.0 TR
MAKE : Kirloskar/Carrier / Hitachi / Blue Star / LG / samsung/ Highly | 5 | Each | 9,000 ₹45,000 | 7,125 ₹35,625 | 5,999 ₹29,995 Lowest |
| 5.03 | FHP motor of capacity 1/5 to 1/18 single phase 920/1440 RPM with capacitor suitable for window/split type AC of any make & capacity. Make : AUE | 10 | Each | 1,400 ₹14,000 | 1,125 ₹11,250 | 999 ₹9,990 Lowest |
| 5.04 | Starting capacitor 80-100 MFD/ 100-120 MFD/120-150 MFD
Make: Keltronor / Siemens | 30 | Each | 260 ₹7,800 | 210 ₹6,300 Lowest | 675 ₹20,250 |
| 5.05 | Running Capacitor 45/50 MFD or 45+6 / 50+6 MFD
Make : EPCOS / Siemens | 30 | Each | 355 ₹10,650 | 285 ₹8,550 Lowest | 420 ₹12,600 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
30 Dec 2025, 6:00 pmClosed
GE (A) AHMEDABAD
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
REPAIR/MAINT OF SUMMER COOLING APPLIANCES AND COMPREHENSIVE MAINT OF CENTRAL AC PLANTS OF MH AND AUDITORIUM AT GE (A) AHMEDABAD
2025_MES_742132_1
8303/E8
Open Tender
Civil Works
Item Rate
270 days
GE A AHMEDABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE A AHMEDABAD
₹54,000
Yes
5 Jan 2026
29 Nov 2025
3 Jan 2026
29 Nov 2025
30 Dec 2025
13 Dec 2025
29 Nov 2025 - 13 Dec 2025
Amount
Labour only with all necessary T&P etc for attending day to day complaints of summer appliances including taking out and replacing of defective components of window / split type air conditioners of any capacity through minimum one skilled mechanic and one helper complete all as specified and directed Note:- (i) Spare parts/components required for replacement shall be measured and paid for separately at supply only rates under respective item of BOQ. (ii) The contractor shall be imposed a penalty at the rate of Rs 500/- per day for each complaint pending for more than 24 Hrs.
Removing defective window/Split type air conditioner of any make and capacity from various locations and transporting to contractor workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and to replace un-serviceable spares parts and re-fixing at various locations after repairing including testing on load at site complete all as specified and directed (All spares compressor, fan motor, relay, capacitor, over load, shall be measured and paid separately under supply only item)
Removing unserviceable burnt sealed compressor from Air conditioner and fixing only new rotary compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed Note:- i) Rotary compressor shall be measured and paid separately under supply only item) ii) If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate.
Taking out Window/Split type Air conditioner of any make and capacity from position and cleaning the complete cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner checking of blower motor, electrical connection and re-fixing the same on its original position and testing complete up to satisfaction complete all as specified and directed (If any spare is required to replaced the same to be measured and paid separately under supply only item)
SUPPLY ONLY ITEM Note : i) The element of fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
New Rotary type compressor of Capcity 1.5 TR MAKE : Kirloskar/Tecumesh/Carrier / Hitachi / Blue Star /LG/ samsung
New Rotary type compressor of Capcity 2.0 TR MAKE : Kirloskar/Carrier / Hitachi / Blue Star / LG / samsung/ Highly
FHP motor of capacity 1/5 to 1/18 single phase 920/1440 RPM with capacitor suitable for window/split type AC of any make & capacity. Make : AUE
Starting capacitor 80-100 MFD/ 100-120 MFD/120-150 MFD Make: Keltronor / Siemens
Running Capacitor 45/50 MFD or 45+6 / 50+6 MFD Make : EPCOS / Siemens
Running Capacitor 36 MFD / / 36+6 MFD Make : EPCOS
Starting relay suitable for 1.0/ 1.5 / 2.0 TR Compressor Make: HI-tech/Classic
Air filter Nylon/plastic type suitable for window / Split type A/C .
Thermostat suitable for window / Split type A/C Make : INDFOSS/Godrej
Front grill for window type AC of any model all as required at site and as directed (Make: LG/ Lancer/ Blue star/ Fedder Lloyed/ Carrier/samsug/voltas)
Condenser/cooling fan blade suitable for window type AC of any make & capacity
Blower unit only suitable for window AC of any capacity & make
PCB card along with remot suitable for window/split type AC of any capacity & make
Digital circuit plate along with remot suitable for windoe/split type AC of any capacity & make
Blower Motor both end coupling complete for Indoor split AC 1.5 / 2.0 TR of any make
Indoor door unit complete with cooling coil, Motor & remot suitable for split type AC of capacity 1.5 TR
Indoor door unit complete with cooling coil, Motor & remot suitable for split type AC of capacity 2.0 TR
Outdoor door unit complete with Rotary compressor, condeser coil & FHP motor suitable for split type AC of capacity 1.5 TR
Outdoor door unit complete with Rotary compressor, condeser coil & FHP motor suitable for split type AC of capacity 2.0 TR
Copper liquid line filter two way / One way.
Contactor suitable for outdoor unit of split type AC of any capacity & make
PVC rounded 3 core, 4.0 Sqmm copper work shop cable. Make : National / Plaza / Polycab / Gloster
Copper pipe suitable for connection of window / split AC of size 1/4'' or 3/8'' (inch) with insulation slleve Foam Heat insulation complete
Copper pipe suitable for connection of window / split AC of size 1/2'' or 5/8'' (inch) with insulation slleve Foam Heat insulation complete
Supply only Refrigerent Gas R-22 in returnable company sealed cylinder complete
Supply only Refrigerent Gas R-134a with company sealed cylinder complete
Supply & replacement wiring loom complete suitable for window / split type air conditioner complete all as specified and directed
Supply, Installation, commissioning and fixing of reverse cycle valve any make suitable for window/Split type AC 1.5/2.0 Ton capacity including required copper pipe and two way switch complete all as specified and directed NOTE:- Gas charging if required shall be paid separately under respective item of BOQ..
Supply & fix condenser/cooling coil suitable for 1.5/2.0 TR window type AC air conditioner including welding work complete all as specified and directed
M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920/1440 RPM with super quality of copper wire of existing size complete with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as speified and directed.
Cutting damaged tray from window type air conditioners and replacing with existing shape and size including all necessary work such as welding, nut, bolts, drilling etc suitable for 1.5 / 2.0 TR Air conditioners complete all as specified and directed
M & L for gas charging M/R-12 / M/R-22 / R-134a / R410a / R32 / M/R-407c to the following appliances & AC plant including removal of old fitter, copper tubing / capillary and replacement of new filter, capillary, short piece of copper tubing of equipment and leakage testing of the same on full load after re-installation of the same at site complete all as specified and directed: -
Window type air conditioner 1.5 Ton capacity of any make.
Split type air conditioner 1.5 Ton AC capacity of any make.
Split / casset type air conditioner 2.0 Ton capacity of any make.
Refrigerator Capacity 165 Ltr of any make
Refrigerator Capacity 300 to 320 Ltr of any make
Deep freezer 300/320 Ltr capacity
Water cooler 40/80 Ltr capacity
Water cooler 150 Ltr capacity
78 TR AC Plant at Auditorium and 117 TR AC Plant of MH
Material and labour for Minor denting and one coat spray paint of window type Air conditioners mentioned item No.1 above complete internally and externally with suitable super enameled synthetic enameled paint of required colour complete all as specified and directed
Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed .
S&F sheet metal enclosure with metal clad socket and earth plug with one number MCB SP of size 20/32 Amp 'c' series, single phase including connecting complete all as specified and directed
S&F sheet metal enclosure with metal clad socket and earth plug with one number MCB TPN 32 Amp, Three phase & Nutral including connecting complete all as specified and directed
M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
2 runs x 4 sqmm (Ph & N) + 1 run x 4 sqmm (earth wire)
2 runs x 6 sqmm (Ph & N) + 1 run x 6 sqmm (earth wire)
Transporting refrigerator of any make and capacity from MES Store Yard to contactor’s workshop for carrying out necessary repair as mentioned in respective items including back to MES Store Yard after repair and testing complete all as specified and directed
Removing unserviceable burnt sealed compressor from refrigerator and fixing only new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified & directed. Note:- (Sealed unit compressor shall be measured and paid separately under supply only item) ii) If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate.
SUPPLY ONLY ITEM Note : i) The element of fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
New sealed compressor of size 1/6 HP to 1/8HP suitable for refrigerator / Deep freezer of capacity 165 Ltr to 310 Ltr Make: Kirloskar / Tecumesh / Whirl pool / LG / Blue star / Hitachi
Relay suitable for refrigerator/Deep freezer 165 Ltr to 310 Ltr capacity Make : INDFOSS/Godrej/Whirl pool
Over load suitable for refrigerator/Deep freezer 165 Ltr to 310 Ltr Make : INDFOSS/Godrej
Thermostate suitable for refrigerator/Deep freezer 165 Ltr to 310 Ltr capacity Make : INDFOSS/Godrej/Whirl pool
PVC freezer door suitable for refrigerator any make & capacity.
Chiller tray of any make and capacity suitable for refrigerator.
Vegitable tray suitable for refrigirator of any make & capacity
Shelves suitable for refrigirator of any make & capacity
Magnetic rubber door gasket suitable for refrigerator of any make & capacity.
Freezer temp control fan motor suitable for refrigirator of any make and capacity
Timer Box of suitable for Refrigirator double door of capacity 200/ 310 Ltr
PVC insulated and PVC sheathes rounded 3 core, 2.5 Sqmm copper work shop cable.
Freezer Box / Chiller Assembly complete with coil and chamber of any make and capacity suitable for refrigerator.
Fan motor suitable for deep freezer of any make and capacity
Screw/Pin type bulb suitable for refrigerator of any make & capacity.
Material and labour for minor dent and painting to refrigerator complete by spray painting with one coat of super enameled paint (existing colour) after proper scrapping of old painted surface complete all as specified and directed
Taking down/out water cooler of any Make and capacity from various locations transporting to contractor’s workshop for carrying out repair as mentioned in respective items of Schedule ‘A’ including transporting back after repair fixing at site re-connecting electrical & water connection & its re-testing on load complete all as specified and directed
Removing unserviceable burnt sealed unit compressor from water coolers and fixing only sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed Note:- (Sealed unit compressor shall be measured and paid separately under supply only item) ii) If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate.
Removing un-serviceable burnt FHP motor from water cooler and supply & fixing new FHP motor with suitable fan blade single phase 1/5 to 1/35 HP suitable for up to 150 Ltr capacity water coolers including testing all as specified and directed.
Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing complete up to satisfaction complete all as specified and directed
SUPPLY ONLY ITEM Note : i) The element of fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same is taken on ledger charge through Receipt Voucher if Required. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
New thermitically sealed unit compressor suitable for 150 Ltr water cooler of Capacity 1.0 TR Make: Kirloskar/Tecumsch/Whirl pool / Lelvinator / Hitachi / Electrolux
New sealed unit compressor suitable for water cooler 40 / 80 Ltr Make: Kirloskar/Tecumsch/ Whirl pool / kelvinator / Hitachi / Electrolux
Relay & OLP suitable for water cooler of any make & capacity Make: HI-tech/Classic
Thermostat switch suitable for water cooler any make & capacity Make : - Indfos
Push taps chromium brass body inner/outer thread suitable for water cooler capacity up to 150 Ltr (as per sample)
Fan motor blade size 12" sweep suitable for FHP motor of water cooler
PVC flexible pipe transparent 15mm/20mm dia dia (as per sample)
PVC float valve 15 / 20 mm dia with rod & ball.
Running Capacitor 4 MFD
3 pin plug top one way 5 Amp, 240V
3 pin plug top 15 Amp, 240V
Submersible water lifting pump of capacity 18 watt suitable for 1.25 M head 230 V AC.
Kit fan motor 1/6 HP suitable 450 mm Sweep 1350 / 1400 RPM. Make : Everest / Summer Cool / Khatian
Industrial type three pin metal clade socket of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser
Industrial type three pin metal clade plug top of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser
Supply and installed refrigeratior of capacity 310 ltr double door, single phase, 220 volt complete all as specified and directed.
Supply and fix in replacement of recessed mounted LED panel light 2'x2' size, 36 watts, full white / warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP / Amstrong / grid false ceiling complete with all fixing accessories including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified and directed
Supply & Fix condenser coil complete with copper tube and aluminium fins suitable for water cooler of any make and capacity complete all as specified and directed
Material and labour for cutting worn out bottom and sheet base frame including MS legs from water cooler of any make and capacity and fixing the same with PGI sheet 16 SWG of existing size and new angle iron base from (angle size iron 50 x 50mm x 6mm) and legs including necessary gas welding and providing nut/bolts etc complete all as specified.
Material and labour for minor denting and painting of water cooler complete by spray painting super enameled with one coat of enamel paint after proper scraping of old painted surface complete all as specification.
Taking down/out desert cooler of any make and capacity from various locations, transporting to MES Store Yard and dismantling all unserviceable parts for repair/overhauling, re-fixing the same back to its original position and making necessary connections with and including copper flexible cable 23/0.0076 Sqmm complete all as specified and directed,
M&L for painting of desert cooler’s external body, fan & pump with one coat of synthetic enameled gray paint & internal body with synthetic enameled black paint complete with brush painting after proper dusting, cleaning and scrapping old painted surfaces complete all as directed.
M&L for replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size.
M&L for rewinding of stator of exhaust fan/kit fan 18” sweep 900 RPM of any make with super quality of winding copper wire of existing size complete with varnishing, backing, testing including painting with synthetic enameled paint of gray colour complete all as specified and directed
M&L for replacement of desert cooler’s cabinet locally fabricated with three side panels front, top and tank including vertical mention made out 22 SWG PGI sheet of size not more than 81.5 x 80.5 x 97.5 Cm with double diversion grills and grill box suitable for 18” sweep fan and making holes with fixing arrangement incl 4 way PVC distributor, PVC pipe 3 to 4 Mtr for spray water, wood wool pads, electrical wiring for fan & pump controlled separately with 5 amp Piano type switch and indicator etc complete all as specified.
Supply and install desert cooler electric driven (single phase) 230 Volt 50 Hz having steel fabricated cabinet of size 26 inch x 17 inch x 50 inch with 22 SWG PGI sheet water storage tank including round chrome double diversion grills, PVC fills Honeypad, Three speed copper wounded Motor 1400 RPM with aluminium blade including submersible water lifting pump suitable to lift water upto 6 feet including Speed regulator,electrical cord three core and plug top 5 Amp complete in respect with audjustable iron wheel stand all as specified. Make :Symphony / Bajaj / BOON / crompton / Voltas
Servicing of scroll chilled water plant of capacity 1 x 39 TR Make : (Voltas) by opening & dismantling of complete components after removing all connections, electrical and piping works and taking out all parts including, cleaning and checking of each parts and replacement of unserviceable parts and re-assembling, commissioning and testing of compressor on load including pressure testing, vacuumising and checking of alignment and all clearance and repairing of insulation, work complete all as specified and directed. Note:- Spare parts required shall be measured and paid as supply only under item No 38 here-in-after.
Supply of spare parts for the above compressor as required at site (fixing cost shall be deemed to have been included against rate quoted for Schedule ‘A’ item No 37 here-in-before)
Water Flow/pressure switch for chiller Make : Honeywell / Jonson control / Danfoss
Water Flow/pressure switch for condenser Make : Honeywell / Jonson control / Danfoss
Temperature sensors.
Pressure transducers
Expansion valve 15 TR Make : Danfoss / Honeywell
Spare part of display panel like display mother board , I/O board etc
Refrigerant driers Make : Sporlan
Pressure testing of chillar with nitrogen gas.
Material and Labour for descalling of condensers of capacity 1 x 39 TR at Auditorium & MH AC Plants locations complete all as described as under :- (a) Blocking of condenser inlet and outlet water pipe. (b) Descalling of condensers tubes with descalling solution mixed with water by pump method for a duration of 08 hours continuous circulation (only descalling solution used for descalling shall be measured and paid separately in respective items of Schedule ‘A’ here-in-after). (c) Opening of bolt side condenser covers for following works:- (i) Cleaning of condenser copper tubes carefully with condenser cleaning brushes all as per entire satisfaction of Engineer-in-Charge. (ii) Removing of rubber gasket of both sides covers, preparing new rubber gasket 6 mm thick, fixing at properly with existing bolts/ nuts/ washers. All above in following locations of Plants:- Note:- Descalling solution required shall be measured and paid as supply only under item No-40 here-in-after.
Supply only descalling solution for condenser or equivalent Make in plastic returnable containers .
Repair / Maintenance of existing 1 x 78 TR Air handling unit alongwith its cooling coils, filters and connected works complete all as directed. (i) Removing of 0.5 Micron filters from existing AHUs and installd new filter of same size (ii) Brushing, cleaning of aluminium fins by normal wire brush to remove / taking out all dust and cleaning of cooling coil by forced spray chemically (such as very clean solution or any other) all as entire satisfaction of Engineer-in-Charge. (iii) Cleaning & removing of complete scale of bottom tray of AHUs as directed at site by the Engineer-in-Charge. (iv) Cleaning of drain pipe from AHUs tray to out side plant room manually as well as any de-scaling solution for proper draining. (v) Fixing new / old GI pipe with existing PVC humidity tank complete with supply & Fix new GI fiting as per site requirement and humidity spray system make functional. Note:- Material required to make AHU in serviceable condition shall be measured and paid as supply only under item No-42 here-in-after.
Supply on items:- (Fixing cost shall be deemed to have been included against rate quoted for Schedule ‘A’ item No 41)
Supply only 1.0 Micron Fine filter with synthetic fiber media of size 600 x 600 x 150 mm (Efti – 0-99.5%) as per sample of nearest size.
All as per item no. 42.01 but of size 610 x 300 x 150 mm (Efti – 0-99.5%) as per sample of nearest size.
Supply only V-Belt B1288LP / B49 Make : Fenner / Metlife Plus / Shree
Supply only V-Belt B73 / B62 Make : Fenner / Metlife Plus / Shree
Supply only Pedestal Bearing as per sample
Supply only Ball Bearing for blower motor as per sample
Supply only AHU sensor Make : Honeywell / Belimo / siemens as per sample
Supply and fixing aluminium cast alloy hub and blade set assembly (as per existing) for 100 TR cooling tower in existing vertical motor including replacement of nuts, bolts, washers as required at site completed as directed.
Repair and Maintenance of FRP Cooling towers 100 TR capacity of central plant at Auditorium & MH,taking down electric motor fan, blade, PVC header, PVC fills and its re-installation after following work:- (i) Painting of internal MS structure with black rubber seal paint over existing coat. (ii) Complete cleaning of cooling tower PVC basin, PVC headers, PVC Nozzles, fills, re-arranging of PVC fills block (old serviceable/ new) including repairing of leakage of suction/ discharge line if any. (iii) Checking of electric motor, opening, cleaning of starter, greasing of bearing, supply and fix new connection plate, fixing back on its original position. (iv) Cleaning of all sides of external surfaces of FRP panels and basin, preparation of surface including painting Two coat of 1st quality synthetic enameled paint as per existing colour code upto satisfaction. (New PVC fills required for replacement shall be measured and paid separately).
Supply & Fix PVC fills block 600 x 300 x 150 mm.
Material and Labour for applying fiber resin coating at internal sides FRP panel / in basin with two layers of fiber cloth mixed with hardener and plaster of paris to ensure leak proof at various cooling towers as directed.
Material and Labour for repair to FRP panels with fiber resin layers at discharge connections in between flange & FRP tower with three layers of fiber clothe mixed with hardener and leak proof connection including preparation hole for flanges and pipe any dia as directed.
Repair / Maintenance Centrifugal pump sets of capacity 3 HP to 7.5 HP at site by means of disconnecting electrically, opening of pump from suction and discharge side, taking down & dismantling complete pump for maintenance, cleaning of all parts, checking of sleeves, bushes, bearing, MS housing cleaning of starter and bearing of motor side, reassembling complete and fixing back in its original position including replacement of unserviceable bearing, Water seal, gland nut & gasket complete as directed. Note :- (New bearing & Water seal shall be measured and paid separately under supply only item)
Supply only water seal for pump of capacity 3 Hp to 7.5 HP (as per sample).
Supply only Ball Bearing for pump of capacity 3 Hp to 7.5 HP (as per sample).
Supply only Impeller for pump of capacity 3 Hp to 7.5 HP (as per sample).
Taking out unserviceable Electric Motor 3 HP to 7.5 HP from foundation after removing all connections electrical and water connection, transporting to local workshop for opening & dismantling of all components including taking out burnt winding wire complete including rewinding of Mono block pump motor with super enameled copper winding wire of existing size after cleaning of winding slots properly varnishing, backing including replacement of unserviceable bearing, Water seal, gland nut & gasket and fixing back on its original position complete testing at site. Note :- (New bearing shall be measured and paid separately under supply only item)
All as per BOQ item no. 52.00 but of capacity 12.5HP/15KW ( Blower Motor )
Supply and replacement water thermometer with brass gauge adopter. Make ; Honeywell / wika Baumer / Air Master / Testo
Supply and replacement of Gas / Water pressure gauge circular type of any dia with brass gauge adopter. Make ; Honeywell / wika Baumer / Air Master / Testo
Supply and replacement of pilot solenoid valve Make : Danfoss as per sample including making electrical connections.
Supply and replacement for fitting of following electrical items of electrical control panel / starters of central AC / as under and making proper electric connections. Note: (Transportation and fitting/labour charges for the following items deemed to be included in respective schedule of item)
Digital Volt meter 240-440 volts, Range 0-500 volt complete, square dial flush type,96 Sqmm.(as per sample)
Digital Amps Meter, square dial flush type 96 Sqmm.(as per sample)
3 pole power contactor 60 Amps Model : HGS-18 / MNX-60 with add on block Make Havells / L&T C&S / Schneider
3 pole power contactor of capacity 40 Amps Model : AC3 40 / MNX-40 with add on block Make : C&S / Havells / L&T / Schneider
3 pole power contactor 30 Amps, Make : C&S / Havells / L&T / Schneider
Electronics timer (As per sample) Make : C&S / L&T / Havells / Schneider
Single phase preventer (as per sample) Make : C&S / L&T / Havells / Schneider
Over load current relay of any type of size & make for 2 to 42 Amps (as per sample) Make : C&S / L&T / Havells / Schneider
Push button switch with element (ON/OFF), Green/Red (As per sample)
Indicating lamp Assy complete LED type in any colour as Red or green or yellow or blue
MCCB FP 160 Amps 36 KA, 415 Volt Make : C&S / L&T / Havells / Schneider
MCCB FP 160 Amps 25 KA, 415 Volt Make : C&S / L&T / Havells / Schneider
MCCB FP 63 Amps 36 KA, 415 Volt Make : C&S / L&T / Havells / Schneider
MCCB FP 63 Amps 25 KA, 415 Volt Make : C&S / L&T / Havells / Schneider
MCCB FP 400 Amps 50 KA, 415 Volt Make : C&S / L&T / Havells / Schneider
MCCB FP 320 Amps 36 KA, 415 Volt Make : C&S / L&T / Havells / Schneider
MCCB FP 250 Amps 50 KA, 415 Volt Make : C&S / L&T / Havells / Schneider
MCB TPN, 16 Amps, 415 Volt Make : C&S / L&T / Havells / Schneider
MCB TPN, 63 Amps, 415 Volt Make : C&S / L&T / Havells / Schneider
MCB TPN, 32 Amps, 415 Volt Make : C&S / L&T / Havells / Schneider
Taking down existing air curtain, opening, removing electric motor, checking of circuit, rewinding of electric motor with super enamelled copper wire of same size including reassembling of air curtain an fixing back on its original position.
Taking out old unserviceable strip heater from site including supply and fix new strip heater Finned type of capacity 3 KW, 240 Volt and making electrical connection with existing wire and make the heating system inserviceable condition,
Taking out following unserviceable water duty valves from existing system of any shape/size and removing the same from site including Supply and fixing new butter fly / sluice valve of the following size in existing water pipe lines by providing Gaskets, Nut / bolts / washer ect. complete all as specified and directed.
Butterfly valve / Sluice valve 80 mm bore Make : Sant / Leader / Kirloskar / Kartar
Non return valve 80mm Make : Sant / Leader / Kirloskar / Kartar
M&L for Miscellaneous spray painting work on Condenser / Chiller water pipe lines with two coat of 1st quality synthetic enameled paint over existing surface (after cleaning and preparation of surface) as per existing colour code complete all as directed.
JYOT ENTERPRIES (BID ID -3502069)
Shree Krushna Supply Corporation (BID ID -3511859)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
TENDERPAGES8303.pdf
Tender Documents • 1.58 MB
BOQ_831039.xls
BOQ • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .