Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 161 MISSION INTER COLLEGE ROAD VILL PITHORAGARH DISTRICT PITHORAGARH STATE UTTARAKHAND PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | L1 | Accepted-AOC Acceptance of tender | |
| 2 | L2₹25.0 L+₹71,975 (2.96%)Rejected-Finance VILL KASNI POST BIN DISTT PITHORAGARH UK | L2 | Rejected-Finance Being Higher Bid | |
| 3 | L3₹30.6 L+₹6.3 L (25.8%)Rejected-Finance VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | L3 | Rejected-Finance Being Higher Bid |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 Aug 2021, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
REPAIR / REPLECEMENT OF SPARE PARTS SOLAR WATER HEATER 100 / 200 LTR CAP INCLUDING MISC EM WORKS AT MIL STN PITHORAGARH
2021_MES_453516_2
8390
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Pithoragarh
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Pithoragarh
₹50,000
Yes
16 Oct 2021
27 Jul 2021
18 Aug 2021
27 Jul 2021
16 Aug 2021
4 Aug 2021
27 Jul 2021 - 4 Aug 2021
Amount
DESCRIPTION OF ITEMS
Checking of fault in Electric wiring of New accn area by deputing adequate number of teams of qualified Electrician and helper for repair, maintenance and making the continuity of supply after rectifying the defects of the electrical system by replacing the U/S items such as switches, replacement of fuse wires, distribution boards, MCB light / power, lamp holders, bracket / pendent / batten, bell / buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings etc to make functional of light / fan / bell point, light & powerplug, including provisioning of small pieces of electricals cables PVC insulated copper multistranded conductor of sizes1.5 Sqmm and other minor items of cost not more than Rs. 10/- complete all as specified and directed by Engineer-in-Charge. Notes:- (a) Replacement of electrical accessories, if required shall be measured and paid separately in supply only. Unserviceable items retrived form complaints shall be abstracted under sch of credit. (b) The fault shall be attended within one day, otherwise recovery shall be charged Rs. 50/- per complaint per day. (c) Electrician shall obtain the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job.
Supply only switch piano one way 5 Amps 240 Volts
Supply only Switch piano, flush type, 15 Amps single pole, one way
Supply only Socket out let 2 in 1, 3 pin, 5 and 15 amps, flush type
Supply only Socket out let 2 in 1, 3 pin, 5 amps, flush type
Supply only Bell push flush type 5 Amps
Supply only Bell electric AC 230 V, Single phase with battary back up
Supply only ceiling fan regulator electronic stepped type operating on 230V,
Supply only ceiling rose two or three terminal operating on 230V, 50Hz
Supply only 11 W ballast of CFL fitting including connection
Supply only CFL 11 W , 2/4pin type 230 V from the fitting of any height
Checking of fault in Solar water Heater of New accn area by deputing adequate number of qualified Solar technician/Plumber and helper with necessary T&P and safety tools etc and ensure that to restore water heater in working condition after rectifying the fault with using minor items of cost not more than Rs. 10/- shall be included in the unit rate complete all as specified (complaint shall be part of the bill), replacement of connected accessories if reqd are measured and paid separetely in relevant items: (a) Replacement of solar heater items, if required shall be measured and paid separetely in relevant items. Unserviceable items retrived form complaints shall be abstracted under sch of credit. (b) The fault shall be attended within one day, otherwise recovery shall be charged Rs. 50/- per complaint per day. (c) Electrician and plumber shall obtain the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job.
Supply only Hot water tank SS 304 ex model cap100 Ltr with heat exchanger
Supply only Hot water tank SS 304 ex model cap 200 Ltr with heat exchanger
Supply only Heating element 2 KW
Supply only Heating element 3 KW
Supply only Thermostat for solar water heater 100/200 Ltr
Supply only Temperature guage for solar water heater 100/200 Ltr
Supply only Toughened Glass for solar water heater 100/200 Ltr
Supply only Makeup tank for solar water heater 100/200 Ltr
Supply only NRV of makeup tank for solar water heater 100/200 Ltr
Supply only Elbow 15mm
Supply only Elbow 20mm
Supply only Elbow 25mm
Supply only Tee 15mm
Supply only Tee 20mm
Supply only Tee 25mm
Supply only Socket 15 mm
Supply only Socket 20 mm
Supply only Socket 25 mm
Supply only Union 15mm
Supply only Union 20mm
Supply only Union 25mm
Supply only Reducer elbow 20mm
Supply only Reducer elbow 25mm
Supply only Reducer Tee 20mm
Supply only Reducer Tee 25mm
Supply only Reducer Socket 20 mm
Supply only Reducer Socket 25 mm
Supply only Hex nipple 15 mm
Supply only Hex nipple 20 mm
Supply only Hex nipple 25 mm
Supply only Tank nipple 15 mm
Supply only Tank nipple 20 mm
Supply only Tank nipple 25 mm
Supply only Plug 15mm
Supply only Plug 20mm
Supply only Plug 25mm
Supply only Nipple 15 mm
Supply only Nipple 20 mm
Supply only Nipple 25 mm
Supply only Ball valve 15mm
Supply only Ball valve 20mm
Supply only Ball valve 25mm
Supply only Gate valve 20 mm, ISI marked all as speficied and directed
Supply only Gate valve grade 25 mm, ISI marked all as speficied and directed
Supply only GI pipe medium grade 25 mm, ISI marked all as speficied and directed
Supply only GI pipe medium grade 15 mm, ISI marked all as speficied and directed
Supply only GI pipe medium grade 20 mm, ISI marked all as speficied and directed
Supply only clamps as per sample
Supply only flexible hose pipe 20 mm as per sample
Supply only gasket as per sample
Supply only of M-Seal
Supply only float valve 20 mm
Supply only float valve 25 mm
Supply only Tank lid 200 ltrs
Supply only Tank lid 500 ltrs
M & L for opening of solar plate & repairing of leakage copper pipe with complete gas welding/soldering as required on site, complete copper tubing in solar water heater and after completion of job reassembling the same complete all as specified and directed
Dismantling exisiting solar water heater 100/200Ltr and descaling the pipe by means of descaling agent the same reassembling after comletion the work Note : Descaling agent shall be measured and paid separately.
Supply only EIS-DA (descaling chemical for all type metal) as complete
M & L for painting of solar water heater of old MS stand with mokey case of tank duly painted of one coat of synthetic enamel paint complete all as specified and directed.
Disconnecting existing over head water storage tanks of capacity 200 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and removing all scale and dirt etc from tank and from mouth of circulating pipes etc and hoisting if required reconnecting and re-fixing in position complete including embossing date of completion of cleaning by stencil with using synthetic enamel paint all as specified and directed. Note : Cleaning of tank should be done carefully by means no float valve broken or no leakage remains after cleaning.
S & F in replacement of Rotational moulded polyethylene water storage three layers tanks (cylindrical vertical with closed top) in white colour, hoisted and fixed in position of capacity 200 Ltrs all as specified and directed by Engr-in-Charge
Taking down / dismantling of PVC/metallic Exhaust fans upto 300mm sweep, overhauling and replace the unserviceble spares parts including reassembling/refixing back in the same location, including with cord flexible copper conductor connections after completion of repairs including testing complete all as directed . Note: 1. Spare parts shall be paid under supply only under relevant items. 2. Motor winding shall be measured and paid separately.
M & L for rewinding of fan motor of any make up to 300mm sweep of exhaust fan with super enameled copper wire of same guage / type, varnishing including removal of existing burnt winding carefully from slots, cleaning the slots with cleaning agents complete all as directed.
Supply only ball bearings suitable for any type of fan/exhaust fan
Supply only Capacitor of 2.5 mfd
Supply only blade assembly suitable for exhaust fan 300 mm PVC type
Supply only blade assembly suitable for exhaust fan 300 mm metelic type
S & F in replacement LED Integrated Batten T5 box type surface mouted, 1x18/20 Watt prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light complete all as specified and directed.
S & F in replacement LED Integrated Batten T5 box type surface mouted, (1x9 Watt) prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting complete all as specified and directed.
S & F in replacement of PVC type exhaust fans moter, AC single phase, 1400 RPM, 230/240 V of size 250 mm sweep complete all as specified and directed.
M & L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through surface and including PVC conduit of appropriate size and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor for earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring complete all as directed. Note: Three runs of 4 Sqmm copper conductor and one run of PVC conduit shall be measured as one unit.
All as per Srl item No 83 above here-in-before with 2 runs of 6 sqmm and 1 run of 6 sqmm earth wire complete all as directed. Note: Three runs of 6sqmm copper conductor and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring complete with 4 runs of 6 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through concealed type and inlcuding PVC conduit including provision of 2 run of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor for earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring complete all as directed. Note: 1. Four runs of 6sqmm copper conductor and two runs of 4sqmm copper conductor and one run of PVC conduit shall be measured as one unit. 2. Cost of cutting, chasing and making good to disturbed surface shall be deemed to inclusive in quoted unit rate.
S & F in replacement MCB single pole, 240 volts, 5-32 Amps of 10 KA 'C' curve complete all as specified and directed.
S & F in replacement MCB single pole & Neutral 240 volts, 32 to 40 amps, of 10 KA,'C'curve complete all as specified and directed.
S & F in replacement miniature circuit breaker (MCB) 4 pole 100 Amps 415 Volts 10KA 'C' curve in the DB complete with connection testing and commissioning complete all as specified and directed.
S & F in replacement miniature circuit breaker (MCB) 4 pole 63 Amps 415 Volts 10KA 'C' curve in the DB complete with connection testing and commissioning complete all as specified and directed.
S & F in replacement miniature circuit breaker (MCB) Triple pole & Neutral pole 40Amps to 100Amps 415 Volts 10KA 'C' curve in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and Fix in repair MCB DB sheet metal enclosure for DB, SPN, 4 way having protection with 200 amps rated bus bar, 440 volts, double door, including grauting suitable for housing MCB's and isolators, complete all as specified and directed.
Supply and Fix in repair MCB DB sheet metal enclosure , SPN, 8 way having protection with 200 amps rated bus bar, 440 volts, double door, including grauting suitable for housing MCB's and isolators, complete all as specified and directed.
Supply and Fix in repair MCB DB sheet metal enclosure TPN, 4 way having protection with 200 amps rated bus bar, 440 volts, double door, including grauting suitable for housing MCB's and isolators, complete all as specified and directed.
S & F in replacement of Vertical type TPN DB, 4 Way, as per IS-8623, IP-42 protection, universal mounting with 100A copper bus bar with neutral bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB 125 Amps TPN as incomer and MCB TP as outgoing, with and including providing following MCCB/MCBs & making necessary electrical connection for incoming & outgoing cables, with copper lugs, crimped with crimping tool :- a) Incoming:- MCCB, TPN, 415 Volts,125 Amp ultimate breaking capacity (lcu)-25 KA, confirm to IEC-60947-2-01 No (b) Out going MCBs:- MCB TP 415 volts 63 Amps having repturing capacity 10 kA, 'C' curve type-4 Nos Note : Cost of MCCB / MCBs shall be deemed to inclusive in quoted unit rate.
S & F in replacement MCCB 100 Amp 35 KA 4 pole 415 V complete with connection testing and commissioning complete all as specified and directed.
Supply and Fix in replacement installation and testing of electric temper proof energy meter, ISI marked, single phase 230 volts 2 wire, 10-60 Amp with optical port facility including sealing the meter with sealing wire and sealing bits, Accuaracy - class 1.0 as per IS 13779/IEC 61036 complete all as specified and directed. (Note: Old unsv meter shall be deposited by contractor in MES store yard.)
Supply, laying, testing and commissioning XLPE insulated, armoured heavy duty electric cable with aluminium stranded conductor, served with inner sheathing of PVC tape armoured with galvanised steel wire overall PVC sheathed 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core including taking out of old unserviceable cable complete all as specified and as directed.
Supply, laying, testing and commissioning XLPE insulated, armoured heavy duty electric cable with aluminium stranded conductor, served with inner sheathing of PVC tape armoured with galvanised steel wire overall PVC sheathed 1100 volts grade, cross-sectional area 35 Sqmm 3.5 core including taking out of old unserviceable cable complete all as specified and as directed.
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth in hard/ dense soil for foundation, etc. or for laying of cable etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed
Removing excavated soil to a distance exceeding 50m but not exceeding 250 m and depositing where directed at a level not exceeding 1.5 m above the starting point , complete all as specified and directed.
M & L for Sand cushioningng (dry sand) to under ground cable for cable protection provided with layers 8cm thick before laying and 15cm thick after laying the cable and punned down to 18 cm thickness complete all as specified and directed. Note:For payment purpose punned thickness of 18cm shall be measured against spread thickness of 18cm as mentioned in para19.75 of SSR Part-I
Supply and laying sub class B bricks old size for protection of cables laid lengthwise perpendicular to the axis of cable, adjecent to each other complete all as specified and directed by Engr-in-charge.
S & F in replacement galvanised iron tubing 40 mm dia light grade laind in trenches/floors/walls for eath lead protection and cables at road crossing etc complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 2009 Part-I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 4mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thck in RCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and GI protection pipe light grade 15mm dia beyond 7.5 mtr from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc. complete all as specified and directed.
M/S KS Shahi and Sons
M/s J P Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .