Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.7 L+₹26,500 (3.16%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹8.5 L
EMD Value
₹21,125
Closing Date
18 Nov 2022, 6:00 pmClosed
Assistant Executive Engineer
o/o The Assistant Executive Engineer PWD Electrical Sub Division Chembukavu,Thrissur-20
GENERAL-Medical College Thrissur-AHU in Labour Room -Replacement of Air handling unit in Labour Room at Surgical block - General Electrical AC work
2022_PWD_528227_1
ESDT(ET)-103/AEE/22-23
Open Tender
Electrical Works
Item Rate
90 days
Thrissur
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,865
₹21,125
11 Jan 2023
11 Nov 2022
21 Nov 2022
11 Nov 2022
18 Nov 2022
11 Nov 2022
Amount
A/C Works
OD155044/2021-2022:Supply, installation testing and commissioning of double skin ceiling suspended AHU with 50 mm sandwiched PUF insulation, double skin type powder coated sheet, the inner sheets of the panels shall be made of 0.8 mm thick GSS, and the outer sheet shall be of 0.8 mm thick GSS with pre plasticized finish, extruded aluminum frame work. Components include 50mm EU4 pre filter (90% down to 10 Micron), Chilled water coil copper tube & Aluminum fins, insulated SS drain pan, DIDW forwarded/backward curved Fans, TEFC squirrel cage induction motor of IE-2 rating including mounting and fixing arrangement, anti vibration isolators. Canvas connection on fan inlet shall be of fire retardant type. AHU mounted Low leakage Aluminum damper at discharge to be provided. All internal blank offs, coil supports and 100mm GI base frame shall be powder coated for durability and clean internalsAHU:1200 CFM ,3.5TR( Including charges for dismantling existing AHU) AHU:1200 CFM ,3.5TR
OD155045/2021-2022:Supply, installation testing and commissioning of double skin ceiling suspended AHU with 50 mm sandwiched PUF insulation, double skin type powder coated sheet, the inner sheets of the panels shall be made of 0.8 mm thick GSS, and the outer sheet shall be of 0.8 mm thick GSS with pre plasticized finish, extruded aluminum frame work. Components include 50mm EU4 pre filter (90% down to 10 Micron), Chilled water coil copper tube & Aluminum fins, insulated SS drain pan, DIDW forwarded/backward curved Fans, TEFC squirrel cage induction motor of IE-2 rating including mounting and fixing arrangement, anti vibration isolators. Canvas connection on fan inlet shall be of fire retardant type. AHU mounted Low leakage Aluminum damper at discharge to be provided. All internal blank offs, coil supports and 100mm GI base frame shall be powder coated for durability and clean internals AHU:2500 CFM ,7.5TR
OD155052/2021-2022:Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/ hot water circulation as specified .Butterfly valve (Manual) 40 mm
OD120296/2022-2023:Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly valve (Manual) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/ hot water circulation as specified .Butterfly valve (Manual) 25 mm
OD155053/2021-2022:Supply ,installation ,testing and commissioning of Ball valve 25 mm dia
OD120311/2022-2023:Supplying , fixing, testing and commissioning of ball valve PN 1.6, bronze/ Gun metal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095 of following sizes as required.40 mm
OD120336/2022-2023:Supplying , fixing, testing and commissioning of Y strainer PN 1.6, bronze/ Gun metal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095 of following sizes as required. 40mm
OD120344/2022-2023:Supplying , fixing, testing and commissioning of Y strainer PN 1.6, bronze/ Gun metal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095 of following sizes as required. 25mm
16.2.13:Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of class 'O' insulation applied by adhesive confirming to standard specifications and finally applying 0.63mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS:1322 as amended up to date) at joints and repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size-32mm dia. (19mm thick nitrile rubber insulation)
16.1.12:Supplying, laying /fixing, testing and commissioning of following nominal size of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass pipe section insulation covered with a layer of 120gm/sqm polythene sheet (vapour barrier) and finally applying 0.63 mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS: 1322 as amended up to date) at joints and repairing of damage to building etc. as per specifications and as required.<br> Note: The Pipes of sizes 150 mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589,from minimum 6.35 mm thick M.S.Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 40mm dia. (50mm thick fiber glass insulation)
16.2.14:Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of class 'O' insulation applied by adhesive confirming to standard specifications and finally applying 0.63mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS:1322 as amended up to date) at joints and repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size-25mm dia. (19mm thick nitrile rubber insulation)
OD155054/2021-2022:Supply, Installation, Testing and Commissioning of following sizes electronic, self balancing, pressure independent type dynamic balancing valve with integrated 3 way modulating control valves in a single body. The actuator shall be capable of accepting upto 1 OV DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum 16 25mm /32 mm/40mm dia.
OD155055/2021-2022:Replacing damaged canvas between AHU and duct and rectifying conditioned air leak from the AHU in existing duct
16.5.1:Supplying, laying /fixing, testing and commissioning of following thickness cross link closed cell preformed sections of polyethylene insulation Nitrile rubber applied aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS:1322 as amended up to date) at joints etc. as per specifications and as required complete in all respect .Insulation with nitrile rubber of thickness 32mm on existing pipe
16.13:Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper
16.15:Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
16.16.a:Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
16.23.1:Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Nitrile rubber insulation - 25 mm
cristalcool
Bidder Name
PONNU HYLINE
cristalcool
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_762487.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .