Loading…
Loading…
Tender Value
₹56.7 L
EMD Value
₹57,000
Closing Date
5 Oct 2026, 6:00 pm
Executive Engineer, R and B Division, Himatnagar
Repairing and Renovation Work for GODOWN Building At Poshina,Dist.:- Sabarkantha
346422
06 of 2025-26
Open
Civil Works - Buildings
Works
Sabarkantha
7 documents required · 7 mandatory
₹2,400
Executive Engineer, R and B Division, Himatnagar
₹57,000
18 Sept 2026
18 Sept 2026
18 Sept 2026
5 Oct 2026
18 Sept 2026
(with brief specification and reference to Quantity Rate In figures Unit Amount
book of specifications)
1 Excavation for foundation upto 1.50 mt 334.00 122.99 Cum
depth including sorting out and stacking
of useful materials and disposing the
excavated stuff upto 50 mt lead
(A) Loose or soft soil
2 Filling available excavated earth 1114.00 136.92 Cum
(excluding rock) in trenches. plinth, sides
of foundations etc. in layers not exceeding
20 cm. in depth consolidating each
disposited layer by ramming and watering.
3 Providing and laying cement concrete 112.00 2944.96 Cum
1:4:8 (1 cement : 4 coarse sand : 8 B.T.
Crushed stone aggregates 40 mm.
nominal size) and curing complete excluding
cost of from work in :(a) Foundation and
4 Providing T M T. bar reinforcement of Fe- 17700.00 77.29 Kg.
500D for R.C.C. work including bending
binding and placing in position complete up
to All floor Level
5 Providing and and laying controlled cement 236.00 6505.41 Cum
concrete M250 and curing etc complete
including the cost of form work but excluding
the cost of reinforcement for R.C.C. work for
internal road / floor etc copmlete.
6 Brick work using common burnt clay building 192.00 4495.98 Cum
bricks having crushing strength not less than
35 Kg./Sq.Cm. Above plinth in cement
mortar 1:5 ( 1-cement : 5-fine sand ) (B)
Conventional (For GF)
7 Providing and fixing Safety Grills of required 2000.00 112.72 Kg.
pattern for windows/door using M.S. polished
bars, Rectangular CRC Pipes of size 50mm
x 30mm x 2mm or Required at required
spacing as per design and hold fast with
coach bolts including one coat of primer and
two coats of matt finished oil painting etc.
Description of Item
(with brief specification and reference to Quantity Rate In figures Unit Amount
book of specifications)
8 Removing and scraping of old deteriorated 126.00 19.92 Sq.Mt
wall and plaster of any thickness fromm wall
/ R.C.C member including stacking of
serviceable material and disposal of
unserviceable from site of work with all lead
9 20 mm. Thick sand faced GUTAKA 1136.00 321.10 Sq.Mt
FINISHED cement plaster on walls upto
mt height above ground level consisting of
12 mm. Thick backing coat of c.m. 1:3 (1
cement : 3 sand) and 8 mm. Thick finishing
coat of c.m. 1:1 (1 cement : 1 sand)
including making groove 6 mm wide and
8 mm deep as approved pattern etc.
complete as directed.
10 Steel work, riveted in built up sections 2.73 5889.50 Q
framed work including cutting, hoisting, fixing
in position and applying a priming coat of red
lead paint. (A) In beams and joists, channels
angles Tees, flats, with connecting plates or
angle cleats as in main and cross beams.
Hip and jack rafters , purlins conneted to
common rafters and the like.
11 Providing and fixing of Ridge flashing for roof 56.00 867.39 Sq.Mt
panel shall be madeout of 0.5 mm thick pre
coated GI sheet . The Precoated sheetshall
be of minimum 240 mpa steel grade
confirming to IS14246:1995 and shall have
zinc coating of minimum 120 gsm asper
IS:277:1992 , 5-7 microns epoxy primer on
both side of thesheet and polyester top coat
15-18 micron. The PPGI Sheet shallhave
plastic protective guard film of minimum
microns toavoid scratches during
transportation. The ridge shall be fixed tothe
steel members by pop rivet or self drilling/self
stitchingfastners @ maximum 450 mm c/c
along length of capping/ flashingetc complet
12 Finishing wall with weather proof exterior 2656.00 73.75 Sq.Mt
emulsion paint on wall surface (two coats)
to give an required shape even shade after
thoroughly brushing the surface to
remove all dirt, and remains of loose
powdered materials etc complete.
Description of Item
(with brief specification and reference to Quantity Rate In figures Unit Amount
book of specifications)
13 Dismentling barbed wire in fencing including 380.00 68.07 Rmt
making rolls and also including dismentling
fencing posts including all earth work
concrete in base and making good the
disturbed ground stacking useful materials
as directed and disposing as directed and
disposing of the unserviceable materials with
all lead and lift.
14 Providing & fixing Rajor coil wire fencing 380.00 894.86 Rmt
having diameter of 0.75 mt including using of
M.S angle 45x45x6mm as per detail drawing,
fixing in cement concrete M-200 etc
completed with one coat of primer & two
coats of oil paint to M.S angle etc. complete
as directed by engineer in charge.
15 Supplying and erecting Flexible PVC 30.00 58.58 Mtrs.
insulated multi strand multi core 1.1 kv grade
ISI marked copper wires of following size to
be erected as directed. e) 1.50 Sq.mm
core round PVC sheathed
16 Supplying and erecting LED street light / 14.00 4248.06 Nos.
Flood light fittings with High power White
LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with
smooth finish powder coated and heat sink
extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more
than 0.95, THD < 10 %, CCT 3000 K to
5700K, Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver
efficiency > 85 %. ( fittings required LM-79 &
LM-80 certificates) (NOTE: Below description
have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may
ranges shown.) (A) Street Light (IP-65),
Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-
voltage protection. (ii) 48 - 59 Watts Cat-III
Description of Item
(with brief specification and reference to Quantity Rate In figures Unit Amount
book of specifications)
17 providing and erecting Miniature circuit 14.00 297.95 Nos.
breaker single pole 0.5A to 2A system and
having breaking capacity 10 KA to be
erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III
18 Providing & erecting 240 V MCB double pole 3.00 362.59 Nos.
switch for lighting Load (B Curve) having
KA breaking capacity & confirms to IS :
in existing box having following capacity (B)
40 Amp. Cat-III
19 Providing & erecting 415 V MCB Four Pole 1.00 811.03 Nos.
for Motor & Inductive Load (C Curve) having
10KA breaking capacity & confirms to IS
:8828 in existing box having following
capacity (C.) for 63 Amp. Cat-III
20 Supplying & erecting earth pit of minimum bore 1.00 4591.46 Nos.
dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm
having 80-200 Micron galvanising, Inner pipe dia
of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant
ohmic value surrounded by highly conductive
compound with high charge dissipation suitable
for following type of applications with chamber
and heavy duty cover. (A)(approved make OEM
has to submit test certificate including value of
earth resistance of installation duly stamped and
signed by agency and officer Incharge has to
ensure the value of earthing resistane mentioned
in test Certificate) & having back filling compound
of (B) Inner chemical (CCM Compound)-
Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load &
dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be
capable to retain moisture for long time
Necessary test report must be submitted by
Agency. (a) For Electrical Installation up to 440V
in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Description of Item
(with brief specification and reference to Quantity Rate In figures Unit Amount
book of specifications)
21 Providing , erecting , fabricating the M.S. 40.00 77.77 Kgs.
structure as per requirement on site
incorporating proper size of M.S.
angles,square,round, flats, bars, channels,
sections complete with cutting, welding,
grinding & finishing duly painted with one
coat of red oxide with erection on site as per
direction of engineer in charge with
necessary grouting, cementing, plastering &
finishing complete.
22 Providing and erecting XLPE (IS:7098)(I)-88 435.00 140.39 Mtrs.
ISI armoured cable multistrand / Solid
Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing
trench / pipe of following size of cables (A)
core 4 Sq. mm
23 Making trench in soft soil of suitable width of 284.00 55.55 Mtrs.
90 cm deep for laying cable or locating the
fault all over the run and back filling the
same and making the surface as normal
24 Supplying & erecting approved make SMC 1.00 515.10 Nos.
press moulded composite FRP. loop-in, loop-
out approx. 2mm thick box complete with
Bakelite connector strip 5way(3P+N+E),DIN
rail for mounting mob & hinged doors as per
requirement having locking arrangements
with mounting clamp with nuts, bolts &
washers suitable for erection on pole with
cable clamps& earth bolt of following size of
box. (b) 250mm x 200mm x 100mm [deep]
25 Supplying & erecting approved make SMC 14.00 476.72 Nos.
press moulded composite FRP. loop-in, loop-
out approx. 2mm thick box complete with
Bakelite connector strip 5way(3P+N+E),DIN
rail for mounting mob & hinged doors as per
requirement having locking arrangements
with mounting clamp with nuts, bolts &
washers suitable for erection on pole with
cable clamps& earth bolt of following size of
box. (C)150mm x 125mm x 100mm [deep]
Description of Item
(with brief specification and reference to Quantity Rate In figures Unit Amount
book of specifications)
26 Supplying & erecting approved make Digital 1.00 3168.37 Nos.
time switch having lithium cell 6 years
operative and operate battery backup
channel day clock with 14 memory
programme, suitable to operate on 240V +
5%, 16A with, floating contacts Minimum
switching setup time 1 minimum & LCD
display. Also comprised permanent ON/OFF
switching. Programming switches & housed
in fire proof thermoplastic enclosure &
transparent cover erected as required with
necessary connection erected as directed.
27 Supplying & erecting power contactor ,AC3 1.00 2782.55 Nos.
duty for time switch complete erected as per
direction Cat III [D] 4 pole 440V 40 Amp.
Total Rs.
Rupees FiftySix Lakh SeventyFour Thousand One Hundred ThirtyFour and Paisa SixtyTwo Only
I / We am / are willing to carry out the work at ________________________________% above / below
percent (should be written in figure and words) of the estimated rate mentioned above. Amount of my /
our tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct_________% Below Add_________% Above
Net Rs.__________________ Net Rs.__________________
In words __________________ In words __________________
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by
the Engineer-In-Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills.
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt.
G.R.: PRC-10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in
R.C.C. items where there is a change as per actual mix design the cost of difference of cement
consumption have been deducted from the rate of original item at the rate of input rate mentioned
in all the tender.
5 Dismentalling of Credit materials amounting of Rs. 20000.00 must be recovered from Contractor's
respective R.A. Bill.
Signature of Contractor
Deputy Executive Engineer Executive Engineer
R.& B. Sub Division R.& B. Division
Khedbrahma Himatnagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2.GR to be attached with DTP_SBD.pdf
GRs - SBD with Index_compressed.pdf
GR - 1.pdf
GR - 2.pdf
GR - 3.pdf
GR - 4.pdf
GR - 5.pdf
04.05.2026.pdf
General Specification - State.pdf
BUILDING WORK BOOKLET.pdf
Details Specification GODOWN Building At Poshina.pdf
Electrical Work - Elect. Sub. Con.pdf
Electrical Work - MOU.pdf
Electrical Work - Sch_A.pdf
Electrical Work - Special Condition.pdf
SBD Book_2023_Rep. Reno. of GODOWN Building At Poshina.pdf
Specification Index - GODOWN Building At Poshina.pdf
GR - 6 - SBD Change.pdf
BOQ - Rep. AND Reno. of GODOWN Building At Poshina.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .