Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC CHAMANAPASSIL HOUSE CRAV 25 VELLAPPALLY KOCHI 28 | KOCHI | ERNAKULAM | KERALA | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.6 L+₹63,855 (2.66%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹22.3 L
EMD Value
₹33,500
Closing Date
4 Oct 2021, 5:00 pmClosed
Office of the Executive Engineer Munambam
Office of the Executive Engineer Munambam
MLA SDF 2 No.s Culverts in Sahodara Nagar Road and 1 No culvert in K V Kumaran Road in ward 11 of Njarakkal Panchayath
2021_HED_438745_1
5/2021-2022/EE/e-T/S
Open Tender
Civil Works - Roads
Item Rate
180 days
Njarakkal
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹33,500
Yes
17 Nov 2021
10 Sept 2021
7 Oct 2021
10 Sept 2021
4 Oct 2021
10 Sept 2021
Amount
APPENDIX 1-Road
3.5.1 : Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
2.7.B : Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.(B)Rubble Stone Masonry in Cement Mortar
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I.P.C.C grade M 10 (i)Nominal mix 1:3:6
11.4.5 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203V. R.C.C. grade M 25
11.8 : Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
11.4.4 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203IV.R.C.C grade M 20
od8092/2020_2021 : Preparation of Foundation for Embankment<br><br>Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means<br><br>Scarifying the existing bituminous road surface to a depth of 150 mm and rolling the surface using three wheel 80 -100 KN Static Roller as per Technical Specification Clause 301.4.
4.1.A.1 : Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. <br> (i) For Grading I Material
51.2.3 : Filling with Quarry Muck <br> Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
60.7.2 : DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
60.7.8 : DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site
60.2.2 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
60.64.1 : Coconut Pile - Supplying and stacking well matured straight coconut post for driving down throug various strata bellow bed level including cost coveyance labour charges etc complete.
od8089/2020_2021 : Coconut Pile - Driving down coconut pile to lines and levels through various strata including all hire charges and labour for fixing , staging platform and all other appliances necessary for pile driving down after pointing the bottom end. Details for one post of 6m long. 15 numbers per day 6x15=90m. Details for 90m length.
od8090/2020_2021 : Putting up bund of 1.00m width for an average height of 1.50m from bed level using causarina poles of 25 to 40cm girth in double rows at 50 cm c/c driving down for an average depth of 1.5m tied together with 1/3 split arecanut reapers @ 50 cmc/c horizontally and 1/3 split arecanut cross ties connecting two rows with GI wire, coir, yarn to all verticals and screening with double new coconut cadjans on either side of bund for full depth and filling inside with clayey soil taken out from the kayal etc complete
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
16.21 : Engraving letters in hard stone
tile work
55.23 : Supplying and laying interlocking tile 80mm or nearest size thickness, minimum strength M30 including providing a layer of 6mm aggregate for 5cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc. complete.
P S SANJEEVAN
Bidder Name
UNNIKRISHNAN
P S SANJEEVAN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_623778.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .