Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAdmitted-Fee/PreQual/Technical/Finance ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹2.0 L+₹6,511.76 (3.29%)Admitted-Fee/PreQual/Technical/Finance KERALA KL | L2 | Admitted-Fee/PreQual/Technical/Finance | |
| 3 | L3₹2.1 L+₹13,861.67 (7.01%)Admitted-Fee/PreQual/Technical/Finance | L3 | Admitted-Fee/PreQual/Technical/Finance | |
| 4 | L4₹2.2 L+₹25,056.60 (12.7%)Admitted-Fee/PreQual/Technical/Finance NALLOOR H NALUKODY P O CHANGANCHERRY | L4 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Xavier Joseph L4 | ALEX PATHROSE L1 | RAJEESH KUMAR R L3 | REGHUNATHAN NAIR L2 |
|---|---|---|---|---|---|---|---|
| 1.00Annual Plan-MCF Construction - Providing Basic Facilities - Electrification-Project No. S0111/26 of Thumpamon Grama Panchayat-General Electrical Work | |||||||
| 1.00 | OD461312/2025-2026:Supply and installation of Pole/Wall mounting type, tamper proof, shockproof, rustproof, rotproof and termite resistant, 100% weatherproof, fire retardant, maintenance-free, cable entry from bottom and/or sides, class FV-0 as per is:11731 part-II or V-0 as per UL-94 , high heat distortion temperature (200°c as per IS:10192), SINTEX make (GSMB 6535) Energy Meter Box (650x350x255mm or nearest) or equivalent make, suitable and with provision to fix three Phase Energy Meter, 3 No. 100/63/32 A, 415 V Bakelite HRC fuse fitting , 63 A, 2 way neutral link, CT's etc. (OR) with DIN Rail in two layers to fix the control gears, including suitable fixing bolt & nut etc. as required. | 1 | each | 4,311 ₹4,311 | 3,835 ₹3,835 Lowest | 4,096.35 ₹4,096.35 | 3,954.05 ₹3,954.05 |
| 1.00 | OD475624/2025-2026:Supply and fixing 100 A, 415 V Bakelite fuse fitting with fuse link in the existing meter board and giving connections etc. | 3 | each | 477 ₹1,431 | 424 ₹1,272 Lowest | 453.25 ₹1,359.75 | 437.5 ₹1,312.5 |
| 1.00 | OD475625/2025-2026:Supply of 100A, 415V, 2way Neutral link mounted on DMC/ SMC base and fixing in the existing Energy Meter Box and giving connections etc. | 1 | each | 278 ₹278 | 247 ₹247 Lowest | 264.17 ₹264.17 | 254.99 ₹254.99 |
| 1.00 | OD504131/2025-2026: Supplying and installation of 4 pole sheet steel enclosure with DIN bar (approved make) mounted on wall in recess /on existing cubicle box etc. as required. | 1 | each | 521 ₹521 | 463 ₹463 Lowest | 494.95 ₹494.95 | 477.75 ₹477.75 |
| 1.00 | OD503210/2025-2026:Supplying and fixing 100 Amp, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 1 | each | 8,161 ₹8,161 | 7,263 ₹7,263 Lowest | 7,753.2 ₹7,753.2 | 7,483.87 ₹7,483.87 |
| 1.01 | OD504648/2025-2026:Supply and installation of switch gear units in sheet steel enclosure compete with handle assembly, door interlock and pad locking arrangement etc. for 100 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuses with ISI marked HRC Fuses on existing angle iron framework or directly on wall by making suitable holes using necessary bolts & nuts, fixing the unit, making good the damages, colour washing etc. including giving necessary connections as required. | 1 | each | 5,284 ₹5,284 | 4,702 ₹4,702 Lowest | 5,019.9 ₹5,019.9 | 4,845.51 ₹4,845.51 |
| 1.01 | 90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) | 1 | each | 9,191 ₹9,191 | 8,179 ₹8,179 Lowest | 8,731.8 ₹8,731.8 | 8,428.48 ₹8,428.48 |
| 1.01 | 90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL | 1 | no | 7,733 ₹7,733 | 6,882 ₹6,882 Lowest | 7,347.1 ₹7,347.1 | 7,091.88 ₹7,091.88 |
| 1.01 | OD475334/2025-2026:Supply and installation of 63 A 10KA, TP MCB( C curve) suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required | 1 | each | 1,615 ₹1,615 | 1,437 ₹1,437 Lowest | 1,535.17 ₹1,535.17 | 1,481.84 ₹1,481.84 |
Tender Value
₹2.2 L
EMD Value
₹5,567
Closing Date
10 Jul 2026, 6:00 pmClosed
Assistant Engineer
LSGD Thumpamon GP
TMGP 2026-27 Project No. S0111/26 MCF Construction - Providing Basic Facilities - Electrification-
2026_LSGD_858575_14
ET1/TGP/2026-27/AE
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Thumpamon
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
Yes
₹5,567
Yes
13 Jul 2026
3 Jul 2026
13 Jul 2026
3 Jul 2026
10 Jul 2026
3 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Annual Plan-MCF Construction - Providing Basic Facilities - Electrification-Project No. S0111/26 of Thumpamon Grama Panchayat-General Electrical Work | |||||
| 1.001 | OD461312/2025-2026:Supply and installation of Pole/Wall mounting type, tamper proof, shockproof, rustproof, rotproof and termite resistant, 100% weatherproof, fire retardant, maintenance-free, cable entry from bottom and/or sides, class FV-0 as per is:11731 part-II or V-0 as per UL-94 , high heat distortion temperature (200°c as per IS:10192), SINTEX make (GSMB 6535) Energy Meter Box (650x350x255mm or nearest) or equivalent make, suitable and with provision to fix three Phase Energy Meter, 3 No. 100/63/32 A, 415 V Bakelite HRC fuse fitting , 63 A, 2 way neutral link, CT's etc. (OR) with DIN Rail in two layers to fix the control gears, including suitable fixing bolt & nut etc. as required. | - | each | - | - |
| 1.002 | OD475624/2025-2026:Supply and fixing 100 A, 415 V Bakelite fuse fitting with fuse link in the existing meter board and giving connections etc. | - | each | - | - |
| 1.003 | OD475625/2025-2026:Supply of 100A, 415V, 2way Neutral link mounted on DMC/ SMC base and fixing in the existing Energy Meter Box and giving connections etc. | - | each | - | - |
| 1.004 | OD504131/2025-2026: Supplying and installation of 4 pole sheet steel enclosure with DIN bar (approved make) mounted on wall in recess /on existing cubicle box etc. as required. | - | each | - | - |
| 1.005 | OD503210/2025-2026:Supplying and fixing 100 Amp, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. | - | each | - | - |
| 1.006 | OD504648/2025-2026:Supply and installation of switch gear units in sheet steel enclosure compete with handle assembly, door interlock and pad locking arrangement etc. for 100 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuses with ISI marked HRC Fuses on existing angle iron framework or directly on wall by making suitable holes using necessary bolts & nuts, fixing the unit, making good the damages, colour washing etc. including giving necessary connections as required. | - | each | - | - |
| 1.007 | 90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) | - | each | - | - |
| 1.008 | 90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL | - | no | - | - |
| 1.009 | OD475334/2025-2026:Supply and installation of 63 A 10KA, TP MCB( C curve) suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required | - | each | - | - |
stage.html
html • 0.02 MB
finance_1451757.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_1451757.xls
BOQ • 0.35 MB
SBD111.pdf
Tender Documents • 2.26 MB
FRD111.pdf
Tender Documents • 0.34 MB
FT111.pdf
Tender Documents • 0.25 MB
PLAG111.pdf
Other Document • 0.25 MB
IPC.pdf
Additional Documents • 0.23 MB
AFF111.pdf
Tender Documents • 0.24 MB
EPAY.pdf
Other Document • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .