EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Establishment of Viral Research and Diagnostics Laboratory (VRDL) for the Department of microbiology, Govt. Medical College Anantnag by way of prefab structure (Electric Part)
2025_PWDJK_291398_1
NIT No.133/2025-26 Dt/09/10/2025
Open Tender
Electrical Works
Percentage
Govt Medical college Anantnag
Please refer Tender documents.
4 documents required · 4 mandatory
₹800
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹41,000
9 Oct 2025
9 Oct 2025
24 Oct 2025
9 Oct 2025
23 Oct 2025
9 Oct 2025
Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate, suitable GI box/ PVC modular box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent make ) excl. cost of conduit.
Wiring for light/power plug points (15/16A heating/AC points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent ) excl. cost of conduit
Supplying and fixing of suitable size GI box / PVC modular box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent)
Supplying and fixing of suitable size GI box / PVC modular box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or eq.)
Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) excl. cost of conduit
Supply, installation, testing and commissioning of (2feet x2feet)36 Watt LED recessed/mounted (square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature - 10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro or eq. make). (commercial series)
Supply, installation, testing and commissioning of 50Watt LED Flood lighting luminaries having aluminum body, minimum 100 lm/w, the luminary housing should be aluminum and the luminary optics shall have a high efficiency with transmittance, average life 50000 hours, Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
Supply, installation, testing and commissioning of 400mm sweep wall fans, incl. making of necessary connections. (Havells/ Philips/ Crompton/ Anchor or eq. make to be approved by EIC).
Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/ Crompton/ Anchor or eq. make to be approved by EIC).
Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excluding cost of conduits(Havells/ Polycab/ Finolex/ Anchor/KEI/RR or eq. make to be approved by EIC).
2 x 2.5 sq.mm + 1x 2.5 sq. mm Lighting Circuits
2 x 4 sq.mm + 1x 4 sq. mm Lighting sub main
4 x 6.0 sq.mm + 1 x 6 sq. mm 3- Phase wiring points
4 x 16 sq.mm + 2 x 6 sq. mm Heating sub main
Supply , installation , testing and commissioning of 32A Three phase industrial plug/ socket with 32A TPN MCB.
Supply and fixing of 25 mm dia./25 mm wide medium class PVC conduit along with accessories, including cutting the wall and making good the same as required.
Supply and fixing of 6 way (4+18) , Double door surface/ recess mounting , Horizontal type, 240/415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK or eq. make to be approved by EIC)
Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA MCB suitable for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ L&T/ABB/ Schneider or eq. make to be approved by EIC).
Supply, installation, testing and commissioning of 32A DP rating 240/415V, 10 KA MCB suitable for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ L&T/ABB/ Schneider or eq. make to be approved by EIC).
Supply, installation, testing and commissioning of 63A TPN MCB rating 240/415V, 10 KA MCB suitable for inductive load in the MCB distribution board complete with necessary connections. (Havells/ Legrand/ L&T/ABB/ Schneider or eq. make to be approved by EIC).
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)
Normal Incoming
250 Amp, 36 KA, FP MCCB
Aluminum Bus Bar 500 Amp set of 4 strips
ON Load Change Over Switch FP 160 amp. (Front operated)
Aluminum Bus Bar 300 Amp set of 4 strips
Outgoing
100 Amp, TPN MCB 10KA
63 Amp, 10 KA, DP MCB
Space for 16 way MCBs
Supply, laying, connecting and commissioning of 150 sq. mm 3.5 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped. ( under ground).
Earthing with GI earth pipe 4.5 mtr. Long 40 mm dia. Including accessories and providing masonry enclosure with cover plate having locking arrangements and watering pipe, trenching and filling with charcoal/coke and salt.
Providing and fixing of 25mmx5mm GI strip on surface or in recess for extending the earthing from earth electrode to controlling panel in one rim to be laid through required dia. of PVC conduit.
Supplying and fixing of modular 6A socket out let/ indicators on existing modular plate and switch box, incl. connections, etc. as required. (Havells/Anchor/Gold medal/Legrand/SSK or eq. make to be approved by EIC) 3 pin 5/6A socket
ii. indicator.
Supply and installation of 32A modular/ industrial plug/socket with 32A DP MCB for ACs
Supply, installation , testing and commissioning of 3 star rating 1.5 Ton Inverter type split Air Conditioners suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector internal unit with one indoor and one outdoor unit. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit will be placed on angle iron stand fitted with nut/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC insulated copper cable and a battery operated wireless remote unit. The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. (Daikin/ Blue Star/ LG or eq. make to be approved by EIC).
Supply, installation , testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton AC operating from input voltage 90-260Volt thereby producing output voltage of 230volts +_ 3%. (4 KVA)
Providing / laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick in size.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.92 MB
BOQ_937187.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .