Loading…
Loading…
Tender ID
Tender Value
₹34.8 Cr
EMD Value
₹34.8 L
Closing Date
6 Apr 2026, 6:30 pmClosed
Vice President, (P), GUDC Ltd., Gandhinagar
Himmatnagar UGD-II under SJMMSVY: Working Survey, Soil Investigation, Design and Construction of Underground Drainage Project with 17.51 MLD Sewerage Treatment Plant Work Including Providing, Supplying, Lowering Laying, Jointing, Testing and Commissioning of Rising Main and Gravity Main Pipes for Sewer Collecting System, Construction of Sewage Pumping Station (SPS), Supplying, Erecting, Testing & Commissioning of Pumping Machineries, Road Restoration, Electrical Work Etc. With Operation and Maintenance With All Allied Works for 02-[Two] Years for UGD work and 07-[Seven] Years for STP Including 03-[Three] Years Defect Liability Period For Himmatnagar Under Ground Drainage with Sewerage Treatment Plant, Tal: - Himmatnagar, Dist.: Sabarkantha, Gujarat Under SJMMSVY
283958
GUDC/PROJECTS/SJMMSVY/UGD-II/HIMMATNAGAR
Open
Civil Works
Works
Gandhinagar
3 documents required · 3 mandatory
₹28,320
GUDC Ltd., Gandhinagar
₹34.8 L
7 Mar 2026
7 Mar 2026
7 Mar 2026
6 Apr 2026
7 Mar 2026
Total of Schedule-B of Himmatnagar Under Ground Drainage (UGD) and Sewerage Treatment Plant (STP) Under
Schedule-C1 O&M of Sewerage Scheme except STP for 2 years
Schedule-C2 O&M of STP for 7 years
Total of Schedule-C of Himmatnagar Under Ground Drainage (UGD) and Sewerage Treatment Plant (STP) Under
Total Project cost of Himmatnagar Under Ground Drainage (UGD) and Sewerage Treatment Plant (STP) Under
Total Project Cost Say in Rs.
Sewerage Collection Network
ITEMS QTY. RATE UNIT
Excavation in bituminous road as per required gradient and line including safety
provisions using site rails and stacking excavated stuff including up to all
1 required lead cleaning the site etc. complete for all lifts as specified. Excavation
in Bituminous Road 1090 288.65 Cu.M.
Excavation for pipe line trenches for water supply, sewerage line, manhole etc.
with shoring and struting if required as per required gradient and line including
2 safety provisions using site rails and stacking excavated stuff including up to all
required lead cleaning the site etc. complete for all lifts and strata as specified.
In all sorts of soil and soft murrum
Upto 1.50 mt depth
In hard murrum, boulders incl. macadam road.
Upto 1.50 mt depth 16735.00 155.25 Cu.M.
In soft rock and/or masonry in CM or L M or Lime Concrete
Upto 1.50 mt depth 110.00 187.45 Cu.M.
In hard rock and / or in C. C. 1:2:4 or RCC with blasting, breaking, chiseling, or by
4 chiseling/breaking only.
Upto 1.50 mt depth 1670.00 427.80 Cu.M.
Providing bedding incl. ramming, watering, levelling, consolidating etc.
5 Complete as per standard and instruction of engineer incharge.
As above with Murrum brought from outside inclduing all lead 3900.00 202.40 Cu.M.
Providing and supplying ISI Standard R.C.C. pipes (of Sulphate Resisting Cement)
in standard lengths of following class and diameter suitable for either collar
joints or rubber ring joints including all taxes, insurance, transportation, freight
charges, octroi, inspection charges, loading, unloading, conveyance to
6 departmental stores, stacking etc. Note : One collar should be supplied with
each full length plain ended RCC pipe, cost included in rates below. One rubber
ring should be supplied with each full length socketed pipe, cost included in
rates below. (Horizontal Cast)
200 mm dia (Class NP3 Test Pressure 0.7 Kg/sq.cm) 5916.00 417.00 Rmt
6.1 300 mm dia (Class NP3 Test Pressure 0.7 Kg/sq.cm) 6588.00 755.00 Rmt
6.2 600 mm dia (Class NP4) 2676.00 2994.00 Rmt
Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following
diameters in proper position, grade and alignment at all level as directed by
7 Engineer-in-charge including conveyance from stores to site of work, labour,
giving hydraulic testing as per ISI code.
200 mm dia (Class NP3 Test Pressure 0.7 Kg/sq.cm) 5916.00 89.95 Rmt
7.1 300 mm dia (Class NP3 Test Pressure 0.7 Kg/sq.cm) 6588.00 136.85 Rmt
7.2 600 mm dia (Class NP4) 2676.00 262.20 Rmt
ITEMS QTY. RATE UNIT
Providing, fixing and constructing of pre-cast RCC M-40 grade circular manholes
with internal dia 1.2m and up to specified depth having pre-cast RCC M-40
grade circular manhole cover frame (ID 0.56m, OD 0.92m), conical piece (top ID
0.56m, bottom ID 1.2m, vertical height 1.005m, wall thickness 125mm), and
circular rings of required heights (ID 1.2m, height 150/225/300/600/900mm,
wall thickness 125mm) below conical piece as per required depth of manhole
and having steel reinforcement in Conical piece @ not less than 80 kg per cum
of concrete, including cast-in-situ PCC M-10 grade (1:3:6) foundation of 1.825m
dia and 150mm thickness, PCC M15 grade circular wall ID 1.125m, wall thickness
200mm, height equal to ID of sewer pipe + one wall thickness of pipe + 50 mm
(to flush the manhole frame with road top, height of wall can be increased but
not more than 100mm), PCC M15 grade benching and channel portion and up to
top level of sewer pipe etc complete with curing compaction and form work,
supplying and fixing heavy duty SFRC manhole cover as per IS 12592 (Part I and
8 II), supplying and fixing plastic encapsulated CI/MS footsteps / SFRC footsteps,
including cost of shuttering, steel reinforcement, testing for water tightness etc
complete in all respect as per drawing, as per specification and the direction of
the Engineer. Note:- Excavation of earth work and road cutting for manhole will
be measured and paid separately.
Pre-cast RCC M-40 grade circular manhole conical piece with inbuilt cover and
frame (height 1.005), cast-in-situ PCC M-10 grade foundation, PCC M15 grade
circular wall ID 1.125m, wall thickness 200mm, wall height equal to ID of sewer
pipe + one wall thickness of pipe + 50 mm, PCC M15 grade benching and
channel portion. Depth of manhole shall be measured from top of manhole
cover upto lowest invert of pipe. (Depth includes in the item = height of Conical
piece + ID of Sewer pipe + 1 Wall thickness of pipe + increased height of wall (if
any) + 50mm). Each
201.00 17800.00 Manhole
Providing and fixing pre-cast RCC M-40 grade circular ring of ID 1.2m, wall
8.1 thickness 125mm, height 150/225/300/600/900mm for constructing extra depth
of manhole beyond depth mentioned in item no-8 as per drawing. 67.51 7810.00 metre
Providing, fixing and constructing of pre-cast RCC M-40 grade circular manholes
with internal dia 1.5m and up to specified depth having pre-cast RCC M-40
grade circular manhole cover frame (ID 0.56m, OD 0.92m), conical piece (top ID
0.56m, bottom ID 1.5m, vertical height 1.305m, wall thickness 125mm), and
circular rings of required heights (ID 1.5m, height 150/225/300/600/900/1200
mm, wall thickness 125mm) below conical piece as per required depth of
manhole and having steel reinforcement in conical piece @ not less than 80 kg
per cum of concrete, including cast-in-situ PCC M-10 grade (1:3:6) foundation of
2.125m dia and 150mm thickness, PCC M15 grade circular wall ID 1.425 m, wall
thickness 200mm, height equal to ID of sewer pipe + one wall thickness of pipe +
50 mm (to flush the manhole frame with road top, height of wall can be
increased but not more than 100mm), PCC M15 grade benching and channel
portion and up to top level of sewer pipe etc complete with curing compaction
and form work, supplying and fixing heavy duty SFRC manhole cover as per IS
9 12592 (Part I and II), supplying and fixing plastic encapsulated CI/MS footsteps /
SFRC footsteps, including cost of shuttering, steel reinforcement, testing for
water tightness etc complete in all respect as per drawing, as per specification
and the direction of the Engineer. Note:- Excavation of earth work and road
cutting for manhole will be measured and paid separately.
Pre-cast RCC M-40 grade circular manhole conical piece with inbuilt cover and
frame (height 1.305), cast-in-situ PCC M-10 grade foundation, PCC M15 grade
circular wall ID 1.425m, wall thickness 200mm, wall height equal to ID of sewer
pipe + one wall thickness of pipe + 50 mm, PCC M15 grade benching and
channel portion. Depth of manhole shall be measured from top of manhole
cover upto lowest invert of pipe. (Depth includes in the item = height of Conical
piece + ID of Sewer pipe + 1 Wall thickness of pipe + increased height of wall (if
any) + 50mm) Each
235.00 23900.00 Manhole
ITEMS QTY. RATE UNIT
Providing and fixing pre-cast RCC M-40 grade circular ring of ID 1.5m, wall
thickness 125mm, height 150/225/300/600/900/1200mm for constructing extra
depth of manhole beyond depth mentioned in item no-9 as per drawing
Providing and constructing Sewer manholes, scraper manholes and unit house
connection chamber, as per the type design in brick masonry in C. M. 1:5 and
inside and outside 20mm thick plastering in C. M. 1:3 necessary 100 mm coping
with reinforcement in R.C.C.M. 200 fixing C. I. steps and fixing manhole frame
and covers (But excluding supply of manhole frame and covers) over manholes
and house connection chambers and fixing Manhole covers (but excluding
supplying of manhole covers) over scraper manhole etc. complete, providing
and fixing safety chain wherever necessary as per the stipulations in the type
design complete as per latest CPHEEO manual. (excl. excavation).
Manhole type "A" Circular type having inside diameter of 1200 mm for depth
upto 1.5 m depth (for 150 mm to 500 mm dia sewer)
Manhole type "A" as above but upto 1.0 M depth.
10.1 Extra depth beyond 1.0 M but upto 1.5 M depth for "A" type manhole above
Providing and erecting C. I. and MS ventilating columns 15 cms. dia. with C.I.
ornamental cap and Min 6.00 Mtr. Height (Height may be varying as per site)
base fixed firmly with necessary foundation with one coat of red lead oxide
paint and one coat of any approved colour with 15 cms, dia.10 Mt.in length with
0.35mt*0.35mt* M100 Encasing, stoneware or R.C.C. pipe connection with M.H.
including excavation
and jointing as required etc. complete. as per drawing.
For 6 Mtr. Height ( 6 Mt MS pipe) 51.00 38911.40 No.
Dewatering by pumping set of required capacity including temporary platform
12 carting pumping at site and fixing the same in position including all accessories,
and fuel and labour etc. complete. Pump set of Capacity 3600.00 21.07 HP/Hr
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at
site of work precast RCC M.200 Frame & cover suitable to drainage M.H. and as
13 per type design & Drawing including cost of reinforcement M.S. Angles or Flat,
curing mold work etc. Heavy duty
Frame Suitable for 50cm opening of MH 280.00 1121.00 No.
13.1 Cover Suitable for 50cm Opening of MH 280.00 1173.00 No.
Refilling the pipeline trenches incl. ramming, watering, consolidating desposal of
14 surplus stuff as directed within a radius of 3 km. Refilling as directed
Drilling of 900mm dia Horizontal borehole for watermain pipeline crossing
under the road incl in all strata with requried length incl fixing of 800mm dia
15 M.S/RCC casing pipe with pushing etc complete various size of pipe for 406.4 to
508mm dia watermain.
Without Water main & with MS Casing Pipe-800 thick:12 50 25712.67 Rmt
Drilling of 1300mm dia Horizontal borehole for watermain pipeline crossing
under the road incl in all strata with requried length incl fixing of 1200mm dia
16 M.S/RCC casing pipe with pushing etc complete various size of pipe for 559 to
711mm dia watermain.
Without Water main & with MS Casing Pipe-1200 thick:16 50 47367.78 Rmt
Total Amount of Schedule-B1 =
Total Amount of Schedule-B1 =
Cast-In-Situ Sewerage Collection Manhole
Description Qty. Rate Unit
Excavation for pipe line trenches for water supply, sewerage line, 229.16 102.35 Cu.M.
manhole etc. all with shoring and struting if required as per required
gradient and line including safety provisions using site rails and stacking
1 excavated stuff including up to all required lead cleaning the site etc.
complete for all lifts and strata as specified.
In all sorts of soil and soft murrum
Upto 1.50 mt depth
In hard murrum, boulders incl. macadam road. 229.16 155.25 Cu.M.
Upto 1.50 mt depth
In soft rock and/or masonry in CM or L M or Lime Concrete 58.16 187.45 Cu.M.
Upto 1.50 mt depth
Providing and casting in situ C.C. in grade M-15 (approx. corresp. 15.6 5441.80 Cu.M.
to prop. 1:2:4) (proportions as per mix design or as per Table 9 of
IS456 2000 in masses by weigh batching ) using granite, quartzite
trap metal of size 6 mm to 20 mm for RCC work, including
scaffolding centering, form work, needle vibrated consolidation,
curing comp. up to 6 meter depth or height (excluding cost of
reinforcement and neat finishing) with centering and
shuttering/deshuttering etc. comp. for structure for other than
water retaining.
Footing (without form work)
Providing and cast in situ C.C. in grade M-30 proportions of 38.40 9444.95 Cu.M.
ingredients as per mix design by weigh batching using granite,
quartzite trap metal of size 12 mm to 20 mm and or 6 mm to
mm including scaffolding centering formwork, needle vibrated
3 consolidation, curing and hydraulic testing etc. complete
(excluding cost of reinforcement) with centering and
shuttering/deshuttering etc. comp. up to 6 meter height /depth Av.
G.L.for all water retaining structures.
Flat bottom slab/floor slab/slab with shuttering
3.1 Vertical Wall (Above 25 cm) 105.40 9295.45 Cu.M.
3.2 Flat bottom slab/floor slab/slab with shuttering 17.20 9444.95 Cu.M.
Supplying cutting, bending, binding and placing in position steel 13.70 89129.60 MT
as per plan and design and as per ISS 2502 including cost of steel
and binding wire for reservoirs/structures only including lift up to
6 meter height or depth below G.L. for all diameters.
Do – deformed (TMT) bars confirming to relevant IS Fe –
grade for all diameters.
Cement plaster 20 mm thick in C.M. 1:2 using water proofing 523.70 232.30 Sq.Mt.
compound of approved quality including finishing etc. complete.
Refilling incl. ramming, watering, consolidating desposal of 990.30 25.30 Cu.M.
6 surplus stuff as directed within a radius of 3 km. Refilling as
Providing and fixing cast iron steps of size 500mm x 150mm x 70.00 209.12 Each
7 22.5mm and painting with two coats of Anti-corrosive paint etc.
Description Qty. Rate Unit
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at 28.00 1121.00 Nos.
store or at site of work precast RCC M.200 Frame & cover suitable to
8 drainage M.H. and as per type design & Drawing including cost of
reinforcement M.S. Angles or Flat, curing mold work etc. Heavy duty
Frame Suitable for 50cm opening of MH
8.1 Cover Suitable for 50cm Opening of MH 28.00 1173.00 Nos.
Total Amount of Schedule-B2 =
Total Amount of Schedule-B2 =
House Connection for UGD
ITEMS QTY. RATE UNIT AMOUNT (RS.)
Excavation for pipe line trenches for water supply, sewerage
line, manhole etc. all with shoring and struting if required as
per required gradient and line including safety provisions
using site rails and stacking excavated stuff including up to all
required lead cleaning the site etc. complete for all lifts and
strata as specified.
In all sorts of soil and soft murrum
Upto 1.50 mt depth 10965.36 102.35 Cu.M.
In hard murrum, boulders incl. macadam road.
Upto 1.50 mt depth 3132.96 155.25 Cu.M.
In soft rock and/or masonry in CM or L M or Lime Concrete
Upto 1.50 mt depth
Providing and laying cement concrete 1:5:10 (1- Cement : 5-
Coarse sand : 10- hand broken stone aggregates 40 mm
nominal size) and curing complete excluding cost of formwork
in (A) Foundation and Plinth 493.68 2606.92 Cu.M.
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)
(B) Conventional
RCC precast M.H. Frame & Cover Manufacture, supply &
Delivery at store or at site of work precast RCC M.200 Frame
& cover suitable to drainage M.H. and as per type design &
Drawing including cost of reinforcement M.S. Angles or Flat,
curing mold work etc. light duty
Providing 15mm thick cement plaster in single coat on Rough
(Similar)side of single or half brick walls for interior plastering
upto floor two level and finished even and smooth in
(i) Cement mortar 1:3 (1-cement:3-sand)
Extra over items for finishing with a floating coat of neat
cement slurry. 15678.00 50.54 Sq.mt.
Providing and laying cement concrete work 1:2:4 (1- Cement :
2- Coarse sand : 4- graded stone aggregates 20 mm nominal
size) and curing complete excluding cost of formwork and
reinforcement for reinforced concrete work in
(B) Slabs, landing, shelves, Balconis, Lintels, Beams, Girders
and Cantilever upto floor two level.
ITEMS QTY. RATE UNIT AMOUNT (RS.)
Providing formwork of ordinary timber planking so as to give
a rough finish including centering shuttering strutting and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and removal of
7 the same for in situ reinforced concrete and plain concrete
(H) (1) Sides and soffits of Beams Beam Haunchings
cantilevers Girders Bressumers and Lintels not exceeding 1 M.
in Depth. 1812.00 205.26 Sq.mt.
Providing and laying cement concrete work 1:2:4 (1- Cement :
2- Coarse sand : 4- graded stone aggregates 20 mm nominal
8 size) and curing complete excluding cost of formwork and
reinforcement for reinforced concrete work in (A)
Foundations, footings, Base or columns and Mass concrete
Providing 10mm thick cement plaster in single coat on brick/
concrete walls for interior plastering upto floor two level and
finished even and smooth in (i)Cement mortar 1:3 (1-
cement:3-sand) 810.00 138.70 Sq.mt.
Refilling the pipeline trenches incl. ramming, watering,
10 consolidating desposal of surplus stuff as directed within a
radius of 3 km. Refilling as directed 12595.55 25.30 Cu.M.
Providing and supplying of Class SN8 Structured Wall
polyethelene Piping systems (Pipe with online/offline coupler
and elastomeric sealing ring) with non-smooth External
Annular Corrugated and Smooth Internal Surfaces (Double
Wall) for non-pressure underground Sewerage & Drainage
application as per EN:13476-3 including all local and central
taxes, transportation, freight charges, octroi, inspection
charges, loading, unloading, conveyance to the departmental
stores etc. complete.(ID Dia)
Lowering, laying and jointing of class SN 8 structured wall (
External Annular Corrugated & Smooth Internal surface)
Polyethylene Piping and fittings with the help of coupler ( on
line / off line ) attached with one end of pipes, sliding over the
elastomeric sealing rubber ring placed on the specified valley
of the corrugation at the spigot end, lowering the same into
the trench at all level, laying on the lower bedding
12 (constructed at bottom of trenches) at prescribed
gradient,depth & alignment ,testing the water tightness of
the joints, ensuring the continuity tests of specified pipe
segments etc. complete as per drawing, specifications &
detailed engineering, including carriage of pipes & fittings
from site stacks to the place of laying etc. as per direction of
Engineer-in-charge.
Total Amount of Schedule-B3 =
Total Amount of Schedule-B3 =
Property Connection for UGD
SR. RATE AMOUNT
ITEMS QTY. UNIT
Providing and supplying of Class SN8 Structured Wall
polyethelene Piping systems (Pipe with online/offline
and elastomeric sealing ring) with non-smooth External
Annular Corrugated and Smooth Internal Surfaces (Double
1 Wall) for non-pressure underground Sewerage & Drainage
application as per EN:13476-3 including all local and central
taxes, transportation, freight charges, octroi, inspection
charges, loading, unloading, conveyance to the departmental
stores etc. complete.(ID Dia)
Lowering, laying and jointing of class SN 8 structured wall (
External Annular Corrugated & Smooth Internal surface)
Polyethylene Piping and fittings with the help of coupler ( on
line / off line ) attached with one end of pipes, sliding over
elastomeric sealing rubber ring placed on the specified valley
of the corrugation at the spigot end, lowering the same into
the trench at all level, laying on the lower bedding
(constructed at bottom of trenches) at prescribed
gradient,depth & alignment ,testing the water tightness of
the joints, ensuring the continuity tests of specified pipe
segments etc. complete as per drawing, specifications &
detailed engineering, including carriage of pipes & fittings
from site stacks to the place of laying etc. as per direction of
Engineer-in-charge.
Excavation for pipe line trenches for water supply, sewerage
line, manhole etc. all with shoring and struting if required as
per required gradient and line including safety provisions
using site rails and stacking excavated stuff including up to all
required lead cleaning the site etc. complete for all lifts and
strata as specified.
In all sorts of soil and soft murrum
Upto 1.50 mt depth 16400.00 102.35 Cu.M.
In soft rock and/or masonry in CM or L M or Lime Concrete
Upto 1.50 mt depth
Custom-cut hole in brick masonry for seamless S.W. gully
trap connection, ensuring efficient drainage integration 4000.00 200.00 Nos
Providing and fixing S.W. gully trap with C.I. grating brick
masonry chamber and water tight C.I. cover with frame of
300mm x 300mm size (inside) with standard weight.
(i) Square mouth traps.(B) 150mm x 100mm size P or R type
Refilling the pipeline trenches incl. ramming, watering,
5 consolidating desposal of surplus stuff as directed within a
radius of 3 km. Refilling as directed 10800.00 25.30 Cu.M.
Total Amount of Schedule-B4 =
Total Amount of Schedule-B4 =
Restoration of Road Works
SR. RATE AMOUNT
ITEMS QTY. UNIT
Providing, spreading and compacting graded machine
crushed stone aggregate for (WBM) water bound macadam
in required layers including filling with interstices, watering
and compacting with power vibratory roller to achieve the
required dry density including lighting, guarding, barricading
and maintenance of diversion.
Providing and laying dense garded bituminous macadam
(DBM) with Specified graded machince crushed stone
aggregate including loading of aggregate with F.E loader
heating of binder , aggegates & Bitumen at 4.5 % by Total
weight of aggegate in hot mix plant transporting the mixed
material by trippers and laying with pavers finisher to the
required level garde Rolling by power rollers to achieve the
disired dencity including tack coat , including all lead of mix
material with required bitumen complete including bitumen
tack coat at rate 5 Kg /10 Sqmt as per MORT & H
Specification ( 6 mm grit and 10 to 12 mm crushed metal
shall be used from Morbi / Beti rajkot Side only)
Providing and laying 40mm thick bituminous concrete (BC)
with Specified graded machine crushed stone aggregate with
F.E loader and hot mixing of bitumen at 5.5 % by total weight
of aggregate in hot mix plant transporting the mixed material
in tripper to paver and laying with mechanical paver finisher
to the required level grades and rolling by power rollers to
achieve the desired density including cost of tack coat at
kg / 10 sq mt bitumen material as perMORT & H Specification
( 6 mm grit and 10 to 12 mm crushed metal shall be used
from Morbi / Beti rajkot Side only)
Providing and laying controlled cement concrete M.250 and
curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work in (A)
Foundations, footings, Base of columns and Mass concrete.
Providing and laying cement concrete 1:3:6 (1-Cement : 3-
coarse sand : 6- hand broken stone aggregates 40 mm
nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth 607.42 3095.25 Cu.M.
SR. RATE AMOUNT
ITEMS QTY. UNIT
Providing and fixing pre-cast Rubber Dye / steel Dye inter
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as
4 per approved design Confirming to IS 15658 : 2006 including
35 mm Sand layer for levelling and filling the joint with sand
in proper line and level as per guidlines of IRC : SP 63-2018 Sq.Mt
etc. Complete. 398.20 706.93 .
Graded Granular sub base (GSB)
Providing & laying of compacted thickness of 250 mm Closed
Graded Granular sub base (GSB) in single layer of graded
granular material consisting of machine cut black Trap stone
aggregate, as per grading - V given in table 400-1 of the
specification MORT&H and compactor to the required
density with 8 - 10 tonne vibratory roller with plain drum or
heavy pneumatic tyred roller of minimum 200 to 300 KN
weight in all seasons as per MORT&H , maintaining the
required slope & grade during the operation as approved by
the engineer in charge & watering to the proper moisture
content and sprinkled with the help of truck mounted water
tank fitted with suitable arrangement. (fully saturated having
CBR value minimum 30)
Total Amount of Schedule-B5 =
Total Amount of Schedule-B5 =
Rising main Pipeline
ITEMS QTY. RATE UNIT
Excavation for pipe line trenches for water supply, sewerage line, manhole etc.
with shoring and struting if required as per required gradient and line including
1 safety provisions using site rails and stacking excavated stuff including up to all
required lead cleaning the site etc. complete for all lifts and strata as specified.
In all sorts of soil and soft murrum
Upto 1.50 mt depth
Providing bedding incl. ramming, watering, levelling, consolidating etc.
Complete as per standard and instruction of engineer incharge.
As above with required quality Sand brought from outside inclduing all lead
Providing and supplying D. I. pipes for following nominal bore diameter with
internal cement mortar lining including all taxes, insurance, transportation,
freight charges, octroi, inspection charges, loading, unloading, conveyance to
departmental stores, stacking etc. complete. (IS 8329-2000).
100 mm dia (K-7)
Manufacture, Supply & Delivery of Ductile Iron Flange socket spigot bends, tees,
reducers or any other specials as per BS-EN-545/1995 Class-A series K12
suitable for use with D.I. Pipes manufactured as per IS:8329/1994delivery of
specials is to be made to site of works any where in Gujarat including all taxes,
loading, unloading, carting, stacking, insurance, inspection charges, octroi etc.
With external bitumen & zinc coating & internal cement mortar lining
Socket & Spigot Type : 80 to 300mm dia 203.37 148.00 Kg
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints /
Mortar lined D. I. Pipes of various classes with CI / MS specials of following
5 diameters in proper position, grade and alignment as directed by Engineer-in-
charge including hydraulic testing etc. comp.
Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest
Edition) of following class and diameter including all taxes, insurance,
transportation, freight charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc. complete.
PN-1 With gear operated (PD type short body)
Providing and supplying C. I. Air valves of approved make & quality of following
class and diameter including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to departmental
stores, stacking etc. complete.
Air valves double acting (DS2)
Lowering, laying and jointing in position following C. I. / D/F Reflux valves,
Butterfly valves, Sluice valves and Air valves including cost of all labour, jointing
material, including nut bolts and giving satisfactory hydraulic testing, etc.
PN-1 With gear operated (PD type short body)
Air valves double ball Flanged (DS2)
ITEMS QTY. RATE UNIT
Construction of valves chambers in brick or bela stone masonry, locally available
in C. M. 1:6. Foundation concrete 150 mm thick in C. C. 1:4:8 of trap metal size
25 mm to 40 mm thick, inside cement plaster in C. M. 1:3 and cement pointing
outside in C. M. 1:3 and top cover of precast RCC slab 100 mm thick (with key
hole in two parts, each with handles or MS Bar etc. complete as given size) Upto
from G. L. to pipe invert level incl. complete civil works but excl. cost of
excavation and refilling, with cast in situ RCC slab in one single piece with fixing
of CI-MH Frame and cover (excl. cost of CI-MH Frame and cover) with 23 mm
thick brick masonry wall in C.M.1:6.
Size of chamber 0.60 m x 0.60 m and 1.0 mt. deep With precast slab in two
parts 15 mm 1.00 6187.00 Nos
Refilling the pipeline trenches incl. ramming, watering, consolidating desposal of
10 surplus stuff as directed within a radius of 3 km. Refilling as directed
Total Amount of Schedule-B6 =
Total Amount of Schedule-B6 =
Civil Work of Construction of Sewage Pumping Station (SPS-17.20 MLD, 8.06 MLD) and 0.15 MLD Auxiliary
Sr. Rate (With Total
Description Qty. Unit
No. Cess) Amount
Excavation for well including removing and spreading the
excavated stuffs directed with all lead.
0.0 m to 1.5 m depth
In all sorts of soils & Soft Murrum 655.00 147.20 Cu.M.
1.5 m to 3.0 m depth
In all sorts of soils & Soft Murrum 22.00 162.15 Cu.M.
1.5 m to 3.0 m depth
In Soft rock 309.00 328.90 Cu.M.
1.5 m to 3.0 m depth
1.3 In hard rock with blasting and chiselling or by chiselling /
Breaking only for finishing 309.00 776.25 Cu.M.
3.0 m to 4.5 m depth
In Soft rock 309.00 345.00 Cu.M.
3.0 m to 4.5 m depth
1.5 In hard rock with blasting and chiselling or by chiselling /
Breaking only for finishing 309.00 794.65 Cu.M.
4.5 m to 6.0 m depth
In Soft rock 309.00 364.55 Cu.M.
4.5 m to 6.0 m depth
1.7 In hard rock with blasting and chiselling or by chiselling /
Breaking only for finishing 309.00 813.05 Cu.M.
6.0 m to 7.5 m depth
1.8 In hard rock with blasting and chiselling or by chiselling /
Breaking only for finishing 618.00 834.90 Cu.M.
7.5 m to 9.0 m depth
1.9 In hard rock with blasting and chiselling or by chiselling /
Breaking only for finishing 618.00 860.20 Cu.M.
9.0 m to 10.5 m depth
1.10 In hard rock with blasting and chiselling or by chiselling /
Breaking only for finishing 599.00 895.85 Cu.M.
10.5 m to 12.0 m depth
1.11 In hard rock with blasting and chiselling or by chiselling /
Breaking only for finishing 350.00 933.80 Cu.M.
12.0 m to 13.50 m depth
1.12 In hard rock with blasting and chiselling or by chiselling /
Breaking only for finishing 264.00 970.60 Cu.M.
13.50 m to 15.00 m depth
1.13 In hard rock with blasting and chiselling or by chiselling /
Breaking only for finishing 73.00 1009.70 Cu.M.
Dewatering by pumping set of required capacity including
temporary platform carting pumping at site and fixing the same in
2 position including all accessories, and fuel and labour etc.
Pump set of Capacity 28800.00 21.07 HP/Hr
Sr. Rate (With Total
Description Qty. Unit
No. Cess) Amount
Providing and casting in situ C.C. in grade M-15 (approx. corresp.
to prop. 1:2:4) (proportions as per mix design or as per Table 9 of
IS456 2000 in masses by weigh batching ) using granite, quartzite
trap metal of size 6 mm to 20 mm for RCC work, including
scaffolding centering, form work, needle vibrated consolidation,
curing comp. up to 6 meter depth or height (excluding cost of
reinforcement and neat finishing) with centering and
shuttering/deshuttering etc. comp. for structure for other than
water retaining.
Footing (without form work) 40.00 5441.80 Cu.M.
Providing and cast in situ C.C. in grade M-30 proportions of
ingredients as per mix design by weigh batching using granite,
quartzite trap metal of size 12 mm to 20 mm and or 6 mm to
mm including scaffolding centering formwork, needle vibrated
4 consolidation, curing and hydraulic testing etc. complete
(excluding cost of reinforcement) with centering and
shuttering/deshuttering etc. comp. up to 6 meter height /depth Av.
G.L.for all water retaining structures.
Flat bottom slab/floor slab/slab with shuttering 137.00 9444.95 Cu.M.
4.1 Vertical Wall (Above 25 cm) 669.00 9295.45 Cu.M.
4.2 Columns 8.00 10714.55 Cu.M.
4.3 Flat bottom slab/floor slab/slab with shuttering 77.00 9444.95 Cu.M.
4.4 Beams / Ring Beams / Girders 7.00 9758.90 Cu.M.
4.5 Lintel / W. Shed / Chhajja 0.60 9444.95 Cu.M.
Supplying cutting, bending, binding and placing in position steel
as per plan and design and as per ISS 2502 including cost of steel
and binding wire for reservoirs/structures only including lift up to
6 meter height or depth below G.L. for all diameters.
Do – deformed (TMT) bars confirming to relevant IS Fe –
grade for all diameters. 108.52 89129.60 MT
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in foundation and
plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B)
Conventional 69.00 4214.33 Cu.M.
Providing 10mm thick cement plaster in single coat on
brick/concrete walls for interior plastering upto floor two level and
finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-
sand) 32.00 138.70 Sq.Mt.
Cement plaster 20 mm thick in C.M. 1:2 using water proofing
compound of approved quality including finishing etc. complete. 413.00 232.30 Sq.Mt.
20mm thick sand faced cement plaster on walls upto height
metres above ground level consisting of 12mm thick backing coat
of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of
C.M. 1:1 (1-cement : 1-sand) etc. complete. 470.00 321.10 Sq.Mt.
Providing and fixing 35 mm thick shutters for Doors, windows
and clerestory windows including Indian teak wood frames 12 cm
10 x 7 cm. size including anodized alluminium fixtures and fastenings
including primer coat of approved quality and two coats of oil
painting etc, complete. (ii) Fully Panelled. 16.00 5533.68 Sq.Mt.
Providing and fixing glazed louvered glass windows and
11 ventilators with teak wood frame 10cm. x 7cm. size including
coats of oil painting to wood work etc.complete 2.00 4202.12 Sq.Mt.
Sr. Rate (With Total
Description Qty. Unit
No. Cess) Amount
Providing and fixing rolling shutters of approved make made of
mm wide M.S. laths inter-locked together through their entire
length and jointed together at the ends by end locks mounted on
12 specially designed pipe shaft with bracket plates, guide channels
and arragements for inside and outside locking with push-pull
operation including the cost of hood cover and spring etc.
complete. (B) Shutters having width 3.5 M. and above 22.00 4546.01 Sq.Mt.
Providing and laying white glazed tiles 6mm thick in flooring
treads of steps and landing laid on a bed of 12mm thickcement
mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush
pointing in white cement. 130.00 950.53 Sq.Mt.
Providing and fixing washbasin with single hole for pillar tap with
C.I. or M.S. brackets painted white including sutting holes and
14 making good the same but excluding fittings.(A) Vitreous
China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In
white colour. 2.00 1519.50 Each
Providing and fixing cast iron (Spun) Nahni trap of the following
nominal diameter of self cleaning design with C.I. screaed down
or higned grating including cost of cutting and making good the
walls and floor 100mm inlet and 50mm outlet.(C) 100mm dia. 4.00 634.17 Each
Providing and fixing to wall, ceiling and floor galvanised Mild
steel tubes (Medium grade) of the following nominal bore, tube
fitting and clamps including making good the wall ceiling and
floor.(A) 15mm 100.00 252.49 Rmt
Providing and fixing to wall, ceiling and floor galvanised Mild
steel tubes (Medium grade) of the following nominal bore, tube
fitting and clamps including making good the wall ceiling and
floor.(C) 25mm 40.00 401.95 Rmt
Providing and fixing screw down bib taps of following size. (A)
Brass screw down bib tap polished bright. (ii) 20mm dia. 4.00 214.81 Each
Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-
coarse sand : 4-graded stone aggregate 20mm nominal size) laid in
one layer and finished with a floating coat of neat cement. (B)
50mm thick 124.00 352.01 Sq.Mt.
Refilling incl. ramming, watering, consolidating desposal of
20 surplus stuff as directed within a radius of 3 km. Refilling as
directed 2541.00 25.30 Cu.M.
Distempeing (Two coats) with oil bound distemper of approved
brand and manufacture and of required shade on wall surfaces to
give an even shade, over and including a priming coat with
21 distemper primer of approved brand and manufacture after
thoroughly brushing the surface free from mortar dropping and
other foreign matter and also including preparing the surface even
and sand papered smooth. 413.00 75.43 Sq.Mt.
Extra for ditempering with oil bound washable distemper on
ceiling and sloping roofs. 413.00 8.27 Sq.Mt.
Finishing wall with weather proof exterior emulsion paint on wall
surface (two coats) to give an required shape even shade after
thoroughly brushing the surface to remove all dirt, and remains of
loose powdered materials.etc complete. 470.00 73.75 Sq.Mt.
Providing cement vata (10cm. x 10 cm. size) quarter round in
23 cement mortar 1:1 including neat cement finishing, watering etc.
complete. 206.00 24.28 Rmt
Sr. Rate (With Total
Description Qty. Unit
No. Cess) Amount
Providing and fixing post and pipe railing as per detailed drawing
including 3 coats of painting to steel works complete. 96.00 1211.79 Rmt
Providing erecting and fixing double coated ISI water tank of
25 required capacity each with all necessary fittings and connection
etc. complete on terrace (2000 Liter Each) 4000.00 3.95 Litre
Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-
coarse sand : 4-graded stone aggregate 20mm nominal size) laid in
one layer and finished with a floating coat of neat cement. (B)
50mm thick. 204.00 352.01 Sq.Mt.
Providing, laying and jointing in true line and level
diametre U.P.V.C (Type B) conforming to IS 13592-1992 with
one end plain and other end socketed with rubber ring, & fittings
conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe shall be jointed with each other with rubber
27 lubricant, pipe shall be fixed on wall using of PVC clamp of the
size 110 mm diametre x 149 mm length x 145 mm heigh at every
2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive solvent
cement including cost of all materials 40.00 876.11 Rmt
Providing laying and jointing in true line and level 50mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall
28 with the help of clamp at every two metre C/C or shall be
concealed as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials. 10.00 195.67 Rmt
Providing and laying polished Kota stone slab flooring over 20mm
(Average) thick base of cement mortar 1:6 (1-cement : 6-coarse
sand) or L.M. 1.1.5 laid over and jointed with grey cement slurry
including rubbing and polishing etc. complete. (B) 30 mm thick
Providing and fixing copper lightning arrestor incl. copper strip
30 and earthing plate etc. complete (incl. cost of excavation for
earthing plate etc. rate per kgs of copper). 100.00 1009.70 Kg
M.S. Ladder(Without safety cage)
Providing and fixing 50 cm wide M.S. Ladder fabricated from
M.S. Flats 10 mm x 75 mm with 20 mm dia steel bar steps in
double rows, @ 30 cm C/C. The include stays of 10 mm x 50 mm
flats fixed at 3 meter C/C with welding anchoring and 3 coats
anticorrosive paint. 78.00 3392.50 Rmt
Supplying & erecting single phase approved make industrial
exhaust fan suitable for medium duty ring mounted low noise
32 operation suitable for medium duty having following dia size and
maximum speed in RPM
450 mm dia 1400 RPM (Cat.II) 2.00 3899.47 Each
Steel work, welded in built up sections framed work including
cutting, hoisting, fixing in position and applying a priming coat of
red lead paint. (A)In beams and joists, channels angles Tees, flats,
with connecting plates or angle cleats as in main and cross beams.
Hip and jack rafters, purlins conneted to common rafters and the
like 36.00 9108.48 Quintal
Painting letters for "Capacity of tank" the size of letters will be
cm height and 50 mm width. Painting letters 45 Cm Ht 400.00 39.10 Nos.
Total Amount of Schedule-B7 =
Total Amount of Schedule-B7 =
Electro-Mechanical and Instrumentation Work of Construction of Sewage Pumping Station (SPS-01)
Description Qty. Unit Rate
1 SEWAGE SUBMERSIBLE NON CLOG PUMP-MOTOR SET (2 Working + 2 Standby) 4 Set 791,602.00
Supply, installation, testing & commissioning of sewage submersible, non clog type suitable for working on three phase, 50 Hz ± 3%, 415 V ±
10%, AC supply, 1450 RPM synchronous speed with 3 core flat copper cable from pump to starter panel with cable end terminations, all
supports, clamps, pipe fittings along with mechanical seal, bearing bush, strainer etc. complete set & following M.O.C:
Casing: CI, Impeller: SS CF8M, Wearing ring & Bearing bush: Bronze, TC mechanical seal, CS / SS bearing, SS shaft with sleeve, SS strainer &
Capacity: 273 m³/hr
Motor Rating: 45 kw
Capacity: 256 m³/hr
Motor Rating: 45 kw
2 SEWAGE SUBMERSIBLE NON CLOG PUMP-MOTOR SET (2 Working + 2 Standby) 4 Set 1,188,257.00
Capacity: 545 m³/hr
Motor Rating: 75 kw
Capacity: 511 m³/hr
Motor Rating: 75 kw
3 SEWAGE SUBMERSIBLE NON CLOG PUMP-MOTOR SET (1 Working) 1 Set 1,834,000.00
Item Description Same as Above
Capacity: 1226 m³/hr
Motor Rating: 160 kw
4 SEWAGE SUBMERSIBLE NON CLOG PUMP-MOTOR SET (1 Working + 1 Standby) 2 Set 189,463.00
Capacity: 13 m³/hr
Motor Rating: 5.5 kw
5 VALVES: 4 No. 12,063.00
Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes,
insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc.
PN-1 With gear operated (PD type short body)
Size: 200 mm NB (On Delivery of each Pump - 1)
6 Size: 300 mm NB (On Delivery of each Pump - 2) 4 No. 25,071.00
7 Size: 350 mm NB (On Common Header) 1 No. 36,723.00
8 Size: 450 mm NB (On Delivery of each Pump - 3 & Common Header) 2 No. 64,491.00
9 Size: 100 mm NB (On Delivery of each Pump & Common Header) 3 No. 4,527.00
10 Size: 100 mm NB (Manually Operated - For Bypass) 3 No. 3,563.00
PN-1 With hand wheel /cap operated (PD type short body)
11 Supply, installation, testing and commissioning of double flanged CI Dual Plate Check Valve conforming to API 594 Class 300 with CS dual 2 No. 5,348.00
door, hinge pin & stop pin of SS 410 , springs of AISI 304 and seat of SS 304 , along with all required accessories, gaskets and hardwares,etc.
and as per specification. including Lowering, laying and jointing in position following C. I. / D/F Reflux valves, Butterfly valves, Sluice valves
and Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete.
PN 1.0 IS 5312 with ISI mark
Size : 100 mm NB (On delivery of each Pump)
12 Size : 200 mm NB (On delivery of each Pump - 1) 4 No. 15,929.00
13 Size: 300 mm NB (On Delivery of each Pump - 2) 4 No. 35,045.00
14 Size: 450 mm NB (On Delivery of each Pump - 3 & Common Header) 2 No. 88,580.00
15 SITC of CI Kinetic Air Valve with Isolation Sluice Valve as per IS 14845 PN-1.0 & IS-14846 PN-1.0 respectively with SS304 float, gun metal 3 No. 16,232.00
nozzle, complete hardware's, bolts, nuts & washers, gaskets etc.
Size: 100 mm NB - Pn 1.0 (On Header pipe O/S. the pump house before interconnecting junction)
16 Lowering, laying and jointing of Valves 8 No. 853.30
Lowering, laying and jointing in position following C. I. / D/F Reflux valves, Butterfly valves, Sluice valves and Air valves including cost of all
labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete.
PN-1 With gear operated (PD type short body)
Size: 200 mm NB (On Delivery of each Pump - 1)
17 Size: 300 mm NB (On Delivery of each Pump - 2) 8 No. 1,312.15
18 Size: 350 mm NB (On Common Header) 1 No. 2,003.30
19 Size: 450 mm NB (On Delivery of each Pump - 3 & Common Header) 4 No. 3,174.00
20 Size: 100 mm NB (On Delivery of each Pump & Common Header) 8 No. 504.85
Size: 100 mm NB (Manually Operated - For Bypass)
PN-1 With hand wheel /cap operated (PD type short body)
21 Lowering, laying and jointing of Air Valves 3 No. 604.90
Lowering, laying and jointing in position following C. I. / D/F Reflux valves, Butterfly valves, Sluice valves and Air valves including cost of all
labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete.
Size: 100 mm NB - Pn 1.0 (On Header pipe O/S. the pump house before interconnecting junction)
22 DI PIPES & SPECIALS - DI Pipe K-9 D/F 14 RMT 2,120.00
Providing and supplying D. I. pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance,
transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete.
Size: 100 mm NB (On Delivery Pipe of Each Pump & Common Header)
Description Qty. Unit Rate
23 Size: 200 mm NB (On Delivery Pipe of Each Pump - 1) 64 RMT 3,898.00
24 Size: 300 mm NB (On Delivery Pipe of each Pump - 2) 64 RMT 6,546.00
25 Size: 350 mm NB (For Common Header) 10 RMT 8,629.00
26 Size: 450 mm NB (Delivery Pipe of each Pump - 3 & Common Header) 26 RMT 12,515.00
27 Size: 100 mm NB For Bypass 10 RMT 2,120.00
28 Supply, installation, testing & commissioning of flange ends Expansion Bellow as per EJMA standards of overall length of minimum 300 mm, 4 No 6,216.00
designed for 15 mm axial compression and 5 mm axial extension with tie rods etc. of following MOC & pressure ratings.
MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA 240 Gr. 304; Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS 1538 / IS
6392 ) & Limit Rods & Nuts: CS - IS
Size : 200 mm NB (On Delivery of Each pump - 1)
29 Size: 300 mm NB (On Delivery Pipe of each Pump - 2) 4 No 10,200.00
30 Size : 350 mm (On Common Header) 1 No 12,840.00
31 Size: 450 mm NB (Delivery Pipe of each Pump - 3 & Common Header) 2 No 18,780.00
32 Flanged Joints of Pipes, Fittings and Specials: 19 No 548.55
Supply, Installation, Making of Flanged DI & GI Pipes, Fittings and Specials Joints with all jointing materials, rubber packing, nut bolts, labour
etc.for complete connection.
Size: 100 mm dia ( For air valve & drain pipe)
Size: 100 mm dia (For Delivery & Header Pipe)
33 Size: 200 mm dia (Pump - 1 Delivery Flange) 32 No 962.55
34 Size: 300 mm dia (Pump - 2 Delivery Flange) 32 No 1,406.45
35 Size: 350 mm dia (Common Header Flanges) 5 No 1,658.30
36 Size: 450 mm dia (Pump - 3 Delivery Flange & Common Header Flanges) 13 No 2,450.65
37 DI SPECIALS 1165 Kg 155.00
Manufacturing, Supply & Delivery of Ductile iron flange socket spigot bends, tees, reducers, or any other specials as per BS - EN-545/1995
Class A series K12 Suitable for use with DI Pipes manufactured as per IS:8329/1994 delivery of specials is to be made at site of works any
where in gujarat including all taxes, loading, unloading, carting, stacking, insurance, inspection charges, octroi etc. complete.
80 to 300 mm Dia
38 350 mm & Above Dia 655 Kg 158.00
39 Supply, installation, testing and commissioning of double flanged Expansion Bellows confirming to EJMA/IS standard with PN 1.0 rating & all 3 No 3,420.00
necessary St.St. hardware''s.
Size : 100 mm NB (On Delivery of Each pump & Common Header)
40 E.O.T. CRANE WITH HOIST 1 Set 530,250.00
Supply, installation, testing & commissioning single girder type fully electrically operated EOT crane with electrically operated hoist, class II
duty, geared travelling trolley with seven meter lift complete with long travel rail track (40 mm sq. bar), moving or cross girder, all three
motions electrically operated by suitable rating motor IP 54, control panel & down pendant control block, brake, safety device, cables form
motor to starter panel & other required accessories & tested as per IS Specifications.
Note: Minimum as specified capacity or higher as per requirement such that EOT crane capacity is min.1.25 times of the pump, motor OR
single heaviest component to be lifted within pump house.
Capacity : 3 Ton. (for Pump Room)
Span: 6-9 m (or as per actual site condition)
Bay length: 12.0 m (max.)
41 Capacity : 2 Ton. (for Pump Room) 1 Set 476,250.00
Span: 6-9 m (or as per actual site condition)
Bay length: 12.0 m (max.)
42 H.O.T. CRANE 1 Set 188,250.00
Supply, installation, testing & commissioning single girder type HOT crane with geared travelling trolly with seven meter lift complete with
manually operated chain pulley block, long travel rail track (40 mm sq. bar), moving or cross girder, brake, safety device etc. & tested to 50%
Capacity : 1 Ton.
Span: 0-6 m (or as per actual site condition)
Bay length: 12.0 m (max.)
43 Chain Pulley Block 2 Set 20,400.00
Providing chain pulley block with triple gear arrangement, lifting hook, laod chain & hand chain & locking device etc.
Size:- 1 T (Manually Operated)
Lift:- 16 Meter
44 SLUICE GATE 5 Nos 562,500.00
Supply, installation, testing and commissioning of Electric Actuator gear operated C.I. Sluice Gate conforming to AWWA C 501 or IS : 13349 -
1992 Class - 1 with rising spindle, single faced, wall thimble mounted, handwheel, flange back frame, head stock, Spindle with supports
brackets having length as specified or to suit site condition, suitable for seating as well as unseating water head, complete in all respect.
Size : 900 mm X 900 mm
46 BAR SCREEN (Manual) 2 Nos 187,500.00
Supply, Installation, Testing and Commissioning of Manuall Bar Screen with trash rack upto plinth level having bar size of 10 mm x 50 mm
and clear spacing between bars of 25 mm, MOC SS-304 and lifting hook etc with all required accessories and hardware.
Size : 1500 mm X 1500 mm
47 BAR SCREEN (Mechanical) 2 Nos 2,700,000.00
Supply, Installation, Testing and Commissioning of Mechanical Bar Screen having bar size of 10 mm x 50 mm and clear spacing between bars
of 25 mm, inclination angle 60 degree, Overall Depth 10 meter, MOC SS-304 with belt conveyor and with all required accessories and
Size : 1500 mm Width
48 Providing, Supplying at site of work with freight, loading, unloading carting, etc. including all taxes and duties complete such as joints, 1050 KG 64.84
channels, angles, plates, iron rails, etc. below 10 mm thickness as per relevant IS and as per specification.
49 Labour Charges for lowering, laying, Fixing with fabrication various size section of MS such as joints channel, angles, plates, etc Complete as 1050 KG 13.07
per relevant IS and as per specification.
Description Qty. Unit Rate
Electrical Items
50 11 kV Two Pole Structure Assembly: 2 Nos. 120,663.00
SITC of 11 kV double pole 9 meter high structure made of 6" X 3" 'I" section girder, 4" X 2" channels, clamps, nuts, bolts, stay wires including
earthing system with following accessories duly connected with ACSR conductors as per approved drawing & in compliance with
requirement of IEC.
(a) 11 kV, 200 A drop out fuses with Synthetic Resin Bonded Paper (SRBP) tubes: 1 Set (01 piece per phase).
(b) 11 kV, 400 A G.O.D. switch complete with earth switch, insulators, operating handle with galvanised pipe, square bar: 1 Set.
(c) 11 kV lightning arrestor with clamps: 3 Nos.
(d) 11 kV Disc Insulators (70KN): 3 Nos.
(e) 11 kV Pin Insulators (5KN): 3 Nos.
(f) 20 mm dia. GI Stay Sets Complete: 2 Set.
51 11 kV HT VCB Panel (1 I/C + 1 O/G) 2 Nos 990,802.00
Supply, installation, testing & commissioning both side extensible, Indoor type HV Switchgear panel confirming to IS-3427, IS-2516 (Part I &
II.sec.1) & IEC-60056 & IEC-62271-100/200 for use on 3 phase, 50 Hz, unearthed AC supply system and having breaking/ruptuing capacity of
500 MVA (26.3 kA for 3 sec) complete with spring charged mechanism, ON-OFF mechanical push button, operation counters, Breaker TNC
switch, Breaker L/R switch, necessary auxiliary switches, closing coil, shunt trip, protection relays & Indicators etc., complete. The panel shall
comprise of air insulated busbars provided with heat shrinkable PVC sleeves. The VCB trolley shall comprise of three vacuum interrupters
with epoxy support insulators and self aligning finger type isolating contacts and necessary mechanical interlocks, safety shutters, isolating
plugs. Enclosure shall be openable from front as well as rear end. The breaker shall be Manual cum motorised mechanism with following
accessories: a) 96 x 96 mm square flush mounting type Ammeter & Volt meter with selector switches, b) Multi function meter, c) Double
core, cast resin type current transofrmer having ratio as per requirement, one core for metering & one core for protection having required
class of accuracy, d) Instantaneous under voltage relay & Temperature rise tripping Relay, e) Triple pole IDMTL two over current and one
earth fault relay with current setting range 50-200% and 10-40%, f) Electrical closing. coil & shunt trip coil operating on 110 V DC, g) Auxiliary
relay for anti pumping device, h) Three limb, drawout type, feeder connected, cast resin insulated, three phase Potential transformer having
ratio & burden as per reqirement & Class 0.5 accuracy, i) Annunciator Windows, Common Hooter / Alarm bell operating on 230 AC/ 110 V
DC, j) Cable boxes suitable to terminate 3 core XLPE cable of required size (As per design), k) 230 V AC to 110 V DC power pack for closing &
tripping circuit common, l) Breaker ON-OFF, Auto trip and spring charged indicators, m) Phase indicating & panel illumination lamps with
plug socket, n) Space Heater with Thermostat.
11 kV HV ICOG Switchgear Panel- Comprising of 630 A Vacuum circuit breaker for 1 no. Incomer, 2no. O / G feeders for 11/0.433 kV
distribution transformers
52 11 kV (Earthed / Unearthed) Grade Cable- Aluminium Conductor 300 mtr 1,045.00
Supply, laying, testing & commissioning of 6.35 / 11 kV (E) grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip /
round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable
trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part2) & IEC:
(Part-2) of following sizes:
3 Core x 240 Sqmm
53 Cable Terminations / Jointing Kits for 6.6 kV (UE) / 11 kV (E) grade XLPE Cable 12 Nos 6,763.00
Providing & fitting heat shrink cable termination / jointing kits for 6.6 kV (UE) / 11 kV (E) grade XLPE insulated cable including necessary
earth connectivity connection, material & consummables making the termination/ joint complete ensuring the joint resistance is within the
permissble limit as per IS, of following types & sizes:
Outdoor Terminations Kit suitable for - 3 Core x 240 Sqmm
54 SITC of outdoor type, three phase, oil immersed, distribution transformer of required KVA & voltage ratio, copper double wound, vector 2 Nos. 729,389.00
group - Dyn11, HV delta connected & LV star connected with neutral brought out connected to provide separate earthing terminals, bushing
/ cable box on HV side and cable box on LV side suitable for cables or bus duct as per requirement with standard fittings, conforming to IS:
1180 (Part-1) / 2014 with its latest amendment including first fill of transformer oil & following accessories. (a) Oil conservator with filling
holes with cap and prismatic oil level gauge.
(b) Silica Gel dehydrating breather charged with silica gel
(c) Oil drain cum sampling valve with plug
(d) Oil filter valve
(e) Lifting Eyes / Hooks / Lugs
(f) Two earthing terminal
(g) Diagram and rating plate
(h) Air release plug (i) Explosion vent with diaphragm
(j) Thermometer pocket
(k) Four bi-directional plain roller with base channel with hauling holes
(l) Fixed / Separate type radiator banks
(m) Off circuit externally operated tapping switch (For rating < 1000 kVA)
(n) 100 mm stem type oil temperature indicator (For rating < 500 kVA)
(o) Bucholtz relay with shut off valve (For rating ≥ 500 KVA)
(p) 150 mm dial type oil temperature indicator with Alarm / Trip contact (For rating ≥ 500 kVA)
(q) 150 mm dial type winding temperature indicator with Alarm / Tip contact (For rating ≥ 1000 kVA)
(r) Marshalling box (For rating ≥ 500 kVA)
(s) 150 mm dia. magnetic type oil gauge (For rating ≥ 1600 kVA) (t) Inspection cover & Jacking lugs (For rating ≥ 1600 kVA)
For transformer having oil storage capacity for 2000 liters and higher, nitrogen injection fire protection system (NIFPS) is to be provided.
With off circuit tap changer +10% to -10% in steps of 2.5%
315 kVA - Eff. Level-2
55 250 kVA - Eff. Level-2 1 Nos. 621,411.00
56 Casting of transformer plinth / foundation including oil soak pit (where required) in situ reinforced cement concrete in M 20 using granite, 3 Set 30,000.00
quartzite trap metal of size 6 mm to 20 mm for RCC work including providing of 53 grade cement & Fe 415 grade TMT bars, scaffolding,
centering, form work, curing etc. complete.
Size: 1250x1250x
Description Qty. Unit Rate
57 MEDIUM VOLTAGE PANEL BOARD (PMCC) 1 Set 756,994.92
SITC of PMCC Panel (50kA) complete in all respects as per SLD / Specification / IS and including following as minimum:
(1) Two nos. FP 630A Microprocessor MCCB for I/c with Digital Voltmeter with Voltmeter selector switch, Digital power Factor Meter, Digital
Ammeter with Ammeter selector switch,MFM with RS-485, R,Y,B,on,off,trip Indicating lamps & ON, E-STOP, Reset Pushbutton, etc,.
(2) 630A TPN Main busbars. (main & auxilary busbars size with current density 0.8A/Sq.mm)
(3) 630 A TPN MCCB for Bus Coupler.
(4) Two nos. (1W+1S) Soft Starter for 45kW Motor with suitable derating and with motor duty MCCB, suitable AC3duty line contactor, fast
acting fuse, door mounting key pad etc. with CBCT, on,off,trip Indicating lamps & ON, E-STOP, Local/Remote, Auto/ Manual selector switch
(5) Two nos. (1W+1S) Soft Starter for 75kW Motor with suitable derating and with motor duty MCCB, suitable AC3duty line contactor, fast
acting fuse, door mounting key pad etc. with CBCT, on,off,trip Indicating lamps & ON, E-STOP, Local/Remote, Auto/ Manual selector switch
(6) One nos. (1W) Soft Starter for 160kW Motor with suitable derating and with motor duty MCCB, suitable AC3duty line contactor, fast
acting fuse, door mounting key pad etc. with CBCT, on,off,trip Indicating lamps & ON, E-STOP, Local/Remote, Auto/ Manual selector switch
(7) 1 nos. APFC Panel feeder with 160A FP Microprocessor MCCB I/C.
(8) One no. 63A TPN MCCB feeders (for PDB - Auxiliary accessories load)
(9) One no. Outdoor lighting LDB feeder with 32A TPN 'C' curve MCB with 32A contactor & Time switch.
(10) 2nos. 32A 'C' curve MCB feeders (for Indoor LDB, 1nos. spare feeders).
(11) 6nos. 630A/1A, Cl.-1 metering CT
(12) 3nos. 630A/1A, Cl.-1.CT for 1nos. APFC
58 MEDIUM VOLTAGE PANEL BOARD (PMCC) 1 Set 714,583.92
SITC of PMCC Panel (50kA) complete in all respects as per SLD / Specification / IS and including following as minimum:
(1) Two nos. FP 400A Microprocessor MCCB for I/c with Digital Voltmeter with Voltmeter selector switch, Digital power Factor Meter, Digital
Ammeter with Ammeter selector switch,MFM with RS-485, R,Y,B,on,off,trip Indicating lamps & ON, E-STOP, Reset Pushbutton, etc,.
(2) 400A TPN Main busbars. (main & auxilary busbars size with current density 0.8A/Sq.mm)
(3) 400A TPN Bus Coupler.
(4) Two nos. (1W+1S) Soft Starter for 45kW Motor with suitable derating and with motor duty MCCB, suitable AC3duty line contactor, fast
acting fuse, door mounting key pad etc. with CBCT, on,off,trip Indicating lamps & ON, E-STOP, Local/Remote, Auto/ Manual selector switch
(5) Two nos. (1W+1S) Soft Starter for 75kW Motor with suitable derating and with motor duty MCCB, suitable AC3duty line contactor, fast
acting fuse, door mounting key pad etc. with CBCT, on,off,trip Indicating lamps & ON, E-STOP, Local/Remote, Auto/ Manual selector switch
(6) 1 nos. APFC Panel feeder with 125A FP Microprocessor MCCB I/C.
(7) One no. 63A TPN MCCB feeders (for PDB - Auxiliary accessories load)
(8) One no. Outdoor lighting LDB feeder with 32A TPN 'C' curve MCB with 32A contactor & Time switch.
(9) 2nos. 32A 'C' curve MCB feeders (for Indoor LDB, 1nos. spare feeders).
(10) 6nos. 400A/1A, Cl.-1 metering CT
(11) 3nos. 400A/1A, Cl.-1.CT for 1nos. APFC
59 Supply, installaton, testing & commissioning LV APFC panel consisting of required capacitor banks for continuous duty to improve P.F. 0.85 1 Set 253,954.00
to 0.99 in required steps enclosed in dust & vermin proof compartment, indoor type, fabricated from CRCA sheet steel with minimum
thickness of 3 mm for base frame / channel / gland plates, 2.0 mm for load bearing members / doors & 1.6 mm for internal partitions,
minimum degree of protection - IP 42, busbar chamber, required size of Al bus bar / terminals, minimum 10 stage APFC relay, metering,
indicating lamps, push buttons complete as per IS: 16636-2017 with latest ammendment & detailed technical specification and
data sheet as under.
110 KVAR capacity: APFC panel consisting following items.
a) 400 A, 50 kA for 1sec. TP, TM based MCCB with spreader terminals & rotary handle b) 0-400 A range analogue ammeter of 96 x 96 mm
size with selector switch
c) 3nos. 400 / 5A, 10 VA CL-1.0 cast resin type current transformer d) Suitable rating of MCCB / MCB & Contractors for each capacitor bank
e) Suitable rating APP type capacitor banks (vacuum impregnated with non-PCB / non toxic oil, internally delta connected with built in
internal fuses complete with discharge resistances & terminal cover) of approved make in required steps with well suited detuned reactor is
series with each capacitor step. (e.g. 200 KVAR capacity will be provided in steps of 2 nos x 5 KVAR, 2 nos x 15KVAR, 2 nos x 30 KVAR &
nos x 50 KVAR) f) Enclosure dimensions: 2100 (H) x 1250 (W) x 600 (D)
60 Supply, installaton, testing & commissioning LV APFC panel consisting of required capacitor banks for continuous duty to improve P.F. 0.85 1 Set 188,070.00
to 0.99 in required steps enclosed in dust & vermin proof compartment, indoor type, fabricated from CRCA sheet steel with minimum
thickness of 3 mm for base frame / channel / gland plates, 2.0 mm for load bearing members / doors & 1.6 mm for internal partitions,
minimum degree of protection - IP 42, busbar chamber, required size of Al bus bar / terminals, minimum 10 stage APFC relay, metering,
indicating lamps, push buttons complete as per IS: 16636-2017 with latest ammendment & detailed technical specification and
data sheet as under.
80 KVAR capacity: APFC panel consisting following items.
a) 250 A, 50 kA for 1sec. TP, TM based MCCB with spreader terminals & rotary handle b) 0-250 A range analogue ammeter of 96 x 96 mm
size with selector switch c) 3nos. 250 / 5A, 10 VA CL-1.0 cast resin type current transformer d) Suitable rating of MCCB / MCB & Contactors
for each capacitor bank e) Suitable rating APP type capacitor banks (vacuum impregnated with non-PCB / non toxic oil, internally delta
connected with built in internal fuses complete with discharge resistances & terminal cover) of approved make in required steps with well
suited detuned reactor is placed in series with each capacitor step. ( e.g. 100 KVAR capacity will be provided in steps of 2 nos x 5 KVAR, 2 nos
x 10KVAR, 2 nos x 15 KVAR & 2 nos x 20 KVAR) f) Enclosre dimensions: 2100 (H) x 1150 (W) x 600 (D)
61 SITC of Power Distribution Board (PDB) for MOV as under: 2 Nos. 7,793.67
3 Phase 4 Wire TPN, 8 way Prewired MOV-PDB for Actuator of gates and EOT Cranes power supply:
Incoming: 63A TPN, MCB 'C' Curve
Outgoing: 4 nos. 6-32A TP MCB 'C' Curve
Description Qty. Unit Rate
62 SITC of Power Distribution Board (PDB) as under: 1 Nos. 4,866.39
(1) Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of
same company of MCB to be used) suitable for (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type
(PPI) (a) single door (ii)6 way
(2) Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on 3 phase and neutral 415V,50Hz. having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic component for following Max. rating erected as directed.
Incoming: (ii) 40Amps. FP Cat. III
(3) Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in
existing box having following capacity
Outgoing: 4 nos. (a) 6 to 32 Amp. Cat.III
63 Control Panel Board 2 Nos 8,383.00
DOL / Star Delta starter suitable for local & remote pump control application consisting of MPCB, overload relay and contactors as per Type
II coordination including digital voltmeter, analogue ammeter with selector switch, run hour meter, required protective relays & control
5.5 kW DOL Starter
64 LT Power Capacitor 10 kVAR 285.00
Supply, installation, testing & commissioning heavy duty APP type capacitor unit, vacuum impregnated with non-PCB / non toxic oil,
internally delta connected with built in internal fuses complete with discharge resistances & terminal cover, rated for 440 V AC, 3 Phase,
Hz as per IS: 13585 Part-1.
10 kVAR APP Type Capacitor
65 SITC of Power Distribution Board (LDB) as under: 2 Nos. 8,872.19
3 Phase 4 Wire TPN, 8 way Prewired LDB for Indoor and Outdoor Lighting:
Incoming: 63A TPN, ELMCB (30mA)
Outgoing: 6 nos. 6-32A TP MCB 'B' Curve
66 MEDIUM VOLTAGE CABLES 100 Mtr 954.00
Supply and unloading & delivery at site, storage & security at site of 1.1 kV, A2XFY/2XWY XLPE insulated (IS 7098) / PVC insulated (IS 1554)
AL / Cu conductor cables as per specification & IS. The cable when laid outside the building shall be laid underground in excavated trench, as
per specified method and shall be laid in prepared trench on cable tray when laid inside the building.
3.5C x 300 sq. mm. A2XFY Cable (2Run for Incomer)
67 3.5C x 150 sq. mm. A2XFY Cable (1Run for APFC) 20 Mtr 504.00
68 3.5C x 185 sq. mm. A2XFY Cable (2Run for Incomer) 100 Mtr 622.00
69 3.5C x 70 sq. mm. A2XFY Cable (1Run for APFC) 20 Mtr 287.00
70 4C x 6 sq. mm. A2XFY Cable (For LDB cum PDB) 110 Mtr 78.00
71 4C x 2.5 sq. mm. 2XWY/2XFY Cable (For Motor Operated Gates) 200 Mtr. 70.00
72 3C x 2.5 sq. mm. 2XWY/2XFY Cable (For Outdoor light / St. Light) 400 Mtr. 61.00
73 2C x 2.5 sq. mm. 2XWY/2XFY Cable (2 Nos. Motor space heater(as required), for 1nos. APFC CT) 120 Mtr. 61.00
74 CABLE END TERMINATION AND CONNECTION: 4 Nos. 1,009.00
SITC of Single / Double compression weather proof type Ni-plated brass cable glands and crimping type Bimetalic lugs / sockets with
necessary tools and equipments as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type
mentioned below & as per specificaitons.
1)Earthing the glands and arm ouring with earthing clamp and jumper and also connecting to common earth bar. 2) The job also includes, if
necessary, supply & fixing of extension busbar of same material on MCCB or panel board terminal / connector to connect more than one
no. of parallel cables or to connect higher size cable to lower size unit. The job also includes earthing the glands and armour of the cable
with common earth bar or flexible copper mesh.(Cable termination qty. shall be as per site requirement)
3.5C x 300 sq. mm. A2XFY Cable (2Run for Incomer)
75 3.5C x 150 sq. mm. A2XFY Cable (1Run for APFC) 2 Nos. 512.00
76 3.5C x 185 sq. mm. A2XFY Cable (2Run for Incomer) 4 Nos. 606.00
77 3.5C x 70 sq. mm. A2XFY Cable (1Run for APFC) 2 Nos. 302.00
78 4C x 6 sq. mm. A2XFY Cable (For LDB cum PDB) 10 Nos. 28.00
79 4C x 2.5 sq. mm. 2XWY/2XFY Cable (For Motor Operated Gates) 20 Nos. 23.00
80 3C x 2.5 sq. mm. 2XWY/2XFY Cable (For Outdoor light / St. Light) 40 Nos. 22.00
81 2C x 2.5 sq. mm. 2XWY/2XFY Cable (2 Nos. Motor space heater(as required), for 1nos. APFC CT) 12 Nos. 21.00
82 CABLE TRAY 220 Mtr. 336.00
Supply & laying GI perforated type cable trays with returned edge / flange, fabricated from 2.0 mm thk sheet steel in the standard length of
2.5 mtrs, duly hot dipped galvanized after fabrication as per IS 2629-1989 / IS 4759-1984 including accessories such as coupler plates/ fish
plates, bends, tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing support as per specification and
instruction of Engineer-in-charge.150 x 50 mm - Ladder type
83 CHEMICAL EARTHING SYSTEM 34 Nos 7,028.82
SITC of chemical earthing with earthpit of minimum bore size dia. 225mm Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per
IS-3043:1987 made of corrosion free G.I. Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm
having 200-250 Micron galvanising or copper coated solid steel road / flat strip type connection terminal 14mm dia with constant ohmic
value surrounded by highly conductive corrosion resistant chemical compound with high charge dissipation suitable for electrical
installation of 11 kV & 440V of 2Mtr. length of Pipe with one no. 25Kg. bag of Back filling compound. (2nos. Each for body of Distribution
Transformer, HT Panel, LV Panel, APFC Panel & Motor)
84 SITC of 50mm(w) x 6mm(T) etc. sizes as required, HOT deep GI Strip including supply & fixing using GI spacers, saddles when laid inside the 736 Kg 77.17
building and inclusive of excavation & refilling of earth when laid outside the building & interconnection with earth pit & all electro-
mechanical equipments.
(50X6 G.I Strip wt.2.3 kg/m, 2.3x150Mt.=345kg.)
85 Supply, laying and erection of 25mm(w) x 3mm(T) etc. sizes as required, HOT deep GI Strip including supply & fixing using GI spacers, 96 Kg 77.17
saddles when laid inside the building and inclusive of excavation & refilling of earth when laid outside the building & interconnection with
earth pit & all electro-mechanical equipments.
(25X3 G.I Strip, 0.6 Kg/m, 0.6x80Mt.=48Kg.)
86 Supply, laying and erection of 40mm(w) x 6mm(T) etc. sizes Copper Strip including supply & fixing of bolts, saddles when laid inside the 224 Kg 787.34
building and inclusive of excavation & refilling of earth when laid outside the building & interconnection with earth pit & Tr. nutral. (40X6
Cu. Strip, 1.88 Kg/m, 1.88 x 60=112 Kg.)
87 SITC of HOT Dip Galvanized iron strip wire 8 SWG (For LDB and PDB etc.) 8 Kg 77.17
(8 SWG G.I Strip, 0.103 Kg/m, 0.103 x 40Mt.=4 Kg)
Description Qty. Unit Rate
88 INTERNAL WIRING 100 Mtr 82.06
SITC of Mains & outlet points wiring with 1.1 kV grade FRLS PVC insulated ISI marked flexible stranded copper conductor wires with medium
class min. 25mm. dia. Rigid PVC pipe and accessories to be erected concealed in / to be run on surface / wall / ceiling with following
sizes as mentioned below. The unit rate wirings shall be with connector, PVC junction box, wires, holder, ceiling rose, angle holder,
switch, sockets, switch board, brass chromium / cadmium plated machine screws, phase and neutral wires, green Earth continuity wires
etc. as required to complete wiring from LDB panel to the final outlet termination points. The wiring shall be as per IS:732, IS:4648
and as per tender specification / IS.
(a) SITC of Mains wiring with 3 wire 1.5 sq.mm.
89 As per above item (b) SITC of Mains wiring with 3 wire 2.5 sq.mm as per tender specification & IS. 40 Mtr 101.06
90 SITC of Point wiring for Light / fan / Bell / Primary Point with 2nos. 1.5 sq. mm & earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 61 Nos 351.71
kv grade FRLS PVC insulated multistrand copper wires, pipe to be erected concealed in flushed on wall / ceiling, complete with 6A
Tissino Type ISI marked flush type switch / bell push & accessories erected on metal / PVC Box covered with 3 mm thick PC (Polycarbonate)
/ Acrylic sheet with necessary lamp holder / ceiling Rose / H. D. connector as directed with medium class Rigid PVC pipe & accessories.
91 SITC of 6A independent Plug with 2nos. 1.5 sq.mm Cu. Mains size wiring & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV 5 Nos 310.60
grade FRLS PVC insulated multistrand copper wires with medium class Rigid PVC pipe and accessories to be erected on wall / ceiling,
complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with earth continuity connection erected on Metal / PVC box
covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet. (2no. for Panel room)
92 SITC of One 300/380 mm dia. Ex fan 6A independent Plug point near Ex. Fan with 2nos. 4 sq.mm Cu. Mains size wiring & earthwire of 8 Nos 471.60
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires with medium class Rigid PVC pipe and
accessories to be erected on wall / ceiling, complete with ISI marked 3Pin socket and tissino type switch erected with earth continuity
connection erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet. Plug point shall be near Ex.Fan.
93 LED LIGHT FIXTURES: 12 Nos 293.26
SITC of LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with
diffuser with company mark/name 160V to 270V, Power Factor more than 0.9, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.)
18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet CAT-III
94 Supplying and erecting led lamps with following wattage capacity of 220 to 240 voltage, minimum 15000 burning hours life, 500 V in built- 5 Nos. 69.00
surge protection, Polycarbonate diffuser, mounting suitable for E14/E27/B22 lamp holders, pf >=
(A)LED Lamps integral type, with PC diffuser suitable LAMP holder
3W Lamp (For Panel room)
95 Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep 3 Nos. 2,289.51
complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy erected with earthing. [ Make shall be
approved by Engineer in Charge]
96 380mm sweep 1400 R.P.M exhaust fan, capacitor type, having double ball bearing, M.S.blades, mounting frame, forearms, suitable 8 Nos. 3,052.47
to operate on 230V,50 HZ AC supply conforming to IS: 2312.Fan shall be painted with epoxy grey colour controlled by one 6 A flush type
switch on board and 6A plug point near Ex. fan. (For 2 nos. Pump Room)
97 EXTERNAL LED LIGHT FIXTURES & LIGHTING: 20 Nos. 5,144.28
Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection.
(i) above 40 to 48 watts
98 SITC of 'B' class galvanised iron pipe 32 mm outside dia 45 cms long duly welded on 20 cms x 20 cms x 3 mm thick M.S. base plate, erected 20 Nos 340.43
on wall or corner for mounting luminaire with necessary hardware materials duly painted for wall mounting indoor & outdoor flood light
fixtures on Wall of Buildings.
99 SAFETY ACCESSORIES 5 Nos 8,586.26
SITC of following safety accessories complete with necessary fixing brackets, other accessories and tools etc. as required to
complete the job.
Supply & Erecting carbon dioxide (CO2) fire extinguisher of 6.5kg capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete. (for 2no. Panel Room)
100 Supplying stand first AID box with anticeptic cream, medicine for use on wounds due burn, crepe bandage, guage bandage, medicated 3 Nos. 297.00
ready to use bandage (Band-aid) adhesive tape for medicinal user, scissors, anticeptic solution (Savlon or similar) etc. (All above contents
shall be of standard makes) (For Pump Room)
101 Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person 3 Nos. 129.06
suffering from Electric shock with minimum 50" diagonally size. (1no. For LT Room)
102 Supply and laying of 4 mm thickness, Rubber Matting as per as per IS:15652/IEC 61111. (for LT & APFC etc. Panels) 24 Sqmtr 1,017.00
103 MISCELLANEOUS: 1050 kg 64.83
Providing, Supply of Structure Steel at site of work with freight, loading, unloading carting, etc. including all taxes and duties complete such
as joints, channels, angles, Iron Rails, ISA/ISMC/ISMB/MS flat, Plates, Chequered plates (below 10mm thickness) etc. required for support
structure of Elecrto-Mechanical equipments etc. for support on floor / wall / beam / brackets etc. as per tender and IS.
104 Labour Charges for lowering, laying, Fixing with fabrication various size section of MS such as joints, channels, angles, Iron Rails, 1050 kg 13.07
ISA/ISMC/ISMB/MS flat, Plates, Chequered plates etc Complete with two coats of red oxide and two coats of approved colour shade of
epoxy paint as per relevant IS and as per specification.
INSTRUMENTATION WORK
Description Qty. Unit Rate
105 INSTRUMENTATION WORK PRESSURE MEASURMENT SYSTEM 14 NOS. 1,412.00
Design, Supply, Installation, Testing, Commissioning of Bourdon Type Pressure Gauge, ±1% accuracy, Direct bottom 1/2" NPT (M) process
connection, IP 67, Glycerine filled, SS304 Case with Bayonet Type Bezel, SS316 L Bourdon Tube, SS 316 Movement material, Aluminium dial
with black graduation on white background, Micro Zero adjustable pointer, neoprene gasket, Blow out disc, shatter proof glass, SS tag plate
106 Design, Supply, Installation, Testing and Commissioning of Sealed Diaphragm Type Pressure Transmitter. 11 NO. 29,147.00
Piezo-resistive sensor technolgy based pressure transmitter with Micro-processor based integral LED/ LCD display, with accuracy of ± 0.3%
of span, external zero and span adjustment, self diagnostics, temperature sensor for compensation. 15 to 36 V DC power supply, output
signal of 4-20 mA DC with HART. Minimum IP 65 degree of protection. Aluminium housing with epoxy coating, Accessories like snubbers for
pump discharge applications, three way manifold, mounting brackets, name plate etc. Material for accessories shall be SS. Protection
Box/Canopy shall be provided for outside installed transmitters.
Pressure Transmitter shall be suitable for following Range
0 to 10 or 0 to 20 kg/cm2 (On Delivery of each pump and Main Header)
107 LEVEL MEASURING SYSTEM 3 NO. 59,723.00
Ultrasonic Type Level Transmitter with Integral Display :
Design, Supply, Installation, Testing and Commissioning of NOn Contact Ultrasonic Type Level Transmitter with Integral Display.
Sensor with Head Mounted Transmitter:
The sensor should be non contact type, field mounting type, housing shall have minimum IP65 protection, PP/ PVC Sensor MOC,
Microprocessor based indicator with LED / LCD digital display,panel/ wall mounting type, power supply shall be 110240 Vac or 15 to 36 Vdc,
50 Hz ± 10 %. Accesories: Mounting bracket, nut, bolts etc as per system requirement and Hook up diagram of the Instruments.
Level Transmitter shall be suitable for following Range.
Meas. Range: upto 15 m at Wet Well
108 ELECTRO MAGNETIC FLOWMETER 1 Nos. 226,181.00
Supply, installation, testing and commissioning of remote type Full Bore Electromagnetic flow meter comprising of IP-68 Sensor, IP-65/66
remote transmitter with 10m cable between sensor and transmitter,Panel mounted flow indicator cum Totalizer along with all mounting
accessories, hardware, etc. complete in all respect and as per specs and shall have following size and measurement range. The scope also
includes necessary connection with header pipe.
Meter Size : 450 mm (At Pump Delivery Header of Pump)
Pipe size: 450 mm
Pipe Material : D.I.
109 Meter Size : 350 mm (At Pump Delivery Header of Pump) 1 Nos. 185,900.00
Pipe size: 350 mm
Pipe Material : DI D/F
110 Meter Size : 100 mm (At Pump Delivery Header of Pump) 1 Nos. 65,837.00
Pipe size: 100 mm
Pipe Material : D.I.
111 INSTRUMENT CABLE & ACCESSORIES 170 MTR. 61.00
'Supply, Laying, Installation, Connection, Termination, Testing
& Commissioning of Instrument Cables, along with cable glands, lugs, cable trays, required junction boxes, fittings and accessores as per
The unit rate shall include
a. Supply, loading & unloading of the cable at site from store. B. Shifitng of cable from site store to place of installation.
c. Fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix the cables safely.
d. Excavation, back filling and levelling of ground alongwith laying of fine sand, protection bricks and other necessary civil material for laying
cables outside the building.
e. Testing and submission of sketches & reports of all the cables laid.
112 INSTRUMENT CABLE TRAY 70 MTR 228.00
Supply & laying GI perforated type cable trays with returned edge / flange, fabricated from 2.0 mm thk sheet steel in the standard length of
2.5 mtrs, duly hot dipped galvanized after fabrication as per IS 2629-1989 / IS 4759-1984 including accessories such as coupler plates/ fish
plates, bends, tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing support as per specification and
instruction of Engineer-in-charge.
100 x 35 mm - Perforated type
113 CABLE END TERMINATION AND CONNECTION : 34 NOS. 22.00
'Supply, fixing, connection, testing and commissioning of double compression brass cable glands and crimping type Bimetalic lugs /
sockets with necessary tools and equipments as specified in specifications and IS complete in all respects. The glands and lugs / sockets
shall be suitable for cable size and type mentioned above. The job also includes earthing the glands and armour of the cable with common
earth bar or flexible copper mesh as applicable.
Construction of 17.51 MLD Sewerage Treatment Plant (STP)
Sr. Item Description Qty. Unit Rate in Rs. Amount
Survey, Soil Testing, design, supply, construction, installation, testing and
commissioning of 17.51 MLD sewage treatment plant with tertiary
treatment (if required) based on open technology with MCC panel room, DG
set, including necessary backfill and all civil, electrical, mechanical, piping
and instrumentation works of with
three months trial run including but not limited to;
a) Connecting the rising main with all fittings up to the STP inlet
b) Internal roads of 4.5m
c) 33% green zone
d) Providing compound wall and
e) Discharge effluent pipe up to 500m.
(Other All conditions will be as per GWSSB SOR & Specifications)
Total Amount of Schedule-B9 =
Total Amount of Schedule-B9 =
O&M of Sewerage Scheme except STP for 2 years
Sr. Item Description Qty. Unit Rate in Rs. Amount
A Comprehensive Operation and maintenance of the various components of 1 Year 1185613.94
Under ground Drainage scheme undertaken in this tender mainly sewer
1 collecting network, pumping station, Rising Main pipeline, pumping
machinery & Electrical works & other works as a whole including
1) Breakdown Maintenance or Emergency Maintenance,
2) Day to day Maintenance,
3) Preventive or Periodic Maintenance,
4) Major Maintenance (or Special repairs and replacement including Training
to O & M staff of Municipality.
The rate shall also include all consumables and deployment of Manpower
but excluding electric power (The electrical bill for power shall be paid by the
The O & M work shall be carried out as per detailed specifications in the
tender & maintaining the record for the same. - For 1st year O&M
2 For 2nd year O&M 1 Year 1244894.637
Total Amount of Schedule-C1 =
Total Amount of Schedule-C1 =
O&M of STP for 7 years
Sr. Item Description Qty. Unit Rate in Amount
1 Comprehensive Operation and Maintenance of the various components 1 Year 2896290
of 17.51 MLD Sewage Treatment Plant and other works as a whole
1) Breakdown Maintenance or Emergency Maintenance,
2) Day to day Maintenance
3) Preventive or Periodic Maintenance,
4) Major Maintenance (or Special repairs and replacement including
Training to O & M staff of Municipality. The rate shall also include cost
against fixed charges, consumables flow dependent charges,
maintenance repair charges, replacement charges, misllaneous charges
and deployment of Manpower but excluding electric power. The O & M
work shall be carried out as per detailed specifications in the tender &
maintaining the record for the same. - For 1st year O&Ms.
---do--- For 1st Year
2 ---do--- For 2nd Year 1 Year 3041104
3 ---do--- For 3rd Year 1 Year 3193160
4 ---do--- For 4th Year 1 Year 3352818
5 ---do--- For 5th Year 1 Year 3520459
6 ---do--- For 6th Year 1 Year 3696481
7 ---do--- For 7th Year 1 Year 3881306
Total Amount of Schedule-C2 =
Total Amount of Schedule-C2 =
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01_SBD_GUDC_Works_Tech_Himmatnagar_UGD-II.pdf
02_Vol-I-B_SBD_GUDC_Works_GCC_Himmatnagar_UGD-II.pdf
03_Vol-II-A-Part-1_Extent of Works_Himmatnagar_STP.pdf
04_Vol-II-A-Part-2_Extent_of_Work_Himmatnagar UGD.pdf
05_Vol-II-A-Part-2_Gen_Tech_And_Process_Require_Himmatnagar_STP.pdf
06_Vol-II-A-Part-3_ITC_Mod Himmatnagar_STP.pdf
07_Vol-II-B-Part-1_TS for Civil Work Himmatnagar STP.pdf
08_Vol-II-B-Part-2_TS for Mechanical Work Himmatnagar STP.pdf
09_Vol-II-B-Part-3_TS for E and I Work Himmatnagar STP.pdf
10_Vol-II-C-Part-1_Func_Guran_of_the_Plant_Mod_Himmatnagar STP.pdf
11_Vol-II-C-Part-2_Data sheet for Process and Civil_Himmatnagar STP.pdf
12_Vol-II-C-Part-3_Data sheet for Mechanical_Himmatnagar STP.pdf
13_Vol-II-C-Part-4_Data sheet Electrical_Himmatnagar STP.pdf
14_Vol-II-C-Part-5_Data sheet Instrumentation_Himmatnagar STP.pdf
15_Vol-II-D-Part-1_Technical_Data_Sheet_Himmatnagar UGD.pdf
16_Vol-II-D-Part-2_TTech_Spec_Civil_E-M_Himmatnagar UGD.pdf
17_Vol-II-General_Part-1_Gen_Tech_Spec_Civil_R_and_B.pdf
18_Vol-II-General_Part-2_Gen_Tech_Spec_Electrical.pdf
19_Vol-III_SBD_GUDC_Works_Price_Bid_Himmatnagar_UGD-II.pdf
21_Vol-IV_Tender_Drawing_Himmatnagar_UGD-II.pdf
22_Vol-V_Cond_of_Cont_for_O_and M_UGD_Himmatnagar_UGD-II.pdf
23_Vol-V_Cond_of_Cont_for_O_and M_STP_Himmatnagar_STP.pdf
24_DMO_2876_01-May-2025_273.pdf
25_GR_DOC_1.pdf
26_GR_DOC_2.pdf
20_Vol-III_Schedule-B_Himmatnagar_UGD-II.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .