Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | ₹13.8 L Quoted ₹14.1 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹15.4 L+₹1.3 L (8.94%)Rejected-AOC | ₹15.4 L+₹1.3 L (8.94%) | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹15.7 L+₹1.6 L (11.3%)Rejected-AOC | ₹15.7 L+₹1.6 L (11.3%) | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 4 | L4₹16.8 L+₹2.7 L (19.4%)Rejected-AOC | ₹16.8 L+₹2.7 L (19.4%) | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 5 | L5₹17.0 L+₹2.9 L (20.3%)Rejected-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | ₹17.0 L+₹2.9 L (20.3%) | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
25 Dec 2021, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR / REPLACEMENT OF B/R AND E/M ITEMS FOR FLOOR PLASTER JOINERY, ALUMINIUM DOOR, PLUMBING ANDSANITARY FITTINGS, RAIN WATER PIPE PVC WATER TANK, ROOF TREATEMENT, ROLLING SHUTTER ETC IN BLDG AT TECHNICAL AREA A AND B IRDE UNDER GE (I) RND DEHRADUN
2021_MES_492452_1
GE(I)RND/9087/E8/21-22
Open Tender
Civil Works
Item Rate
180 days
DEHRADUN
Class E Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2012) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
GE I R N D DEHRADUN
₹36,000
Yes
11 Jan 2022
4 Dec 2021
27 Dec 2021
4 Dec 2021
25 Dec 2021
11 Dec 2021
4 Dec 2021 - 11 Dec 2021
Amount
Dismentling of wall and ceiling boards/ Alca panel /fibre/ pvc Board/PVC sheet panelling pulp, insulation etc or insulation boards/ slabs/blankets any thickness incl cover fillets, fittings, complete all as specified and directed
M&L for suspended false ceiling system using chicago metallic (E grid)exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm thick (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X24mmX0.8mm thick and thick wall angle 22.2mmX22.2mmX 0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed , self embossed . textured designer board, water resistant termite resistant , fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) with Provn of light fixture complete all as directed. Make :- EVEREST or other equivalent as approved.
S&F Brass handles 100mm size, cast type, polished bright as approved by Engr in Charge complete all as specified and directed
S&F 40 mm dia, brass, knobs for cupboard fixed with nut, screw and washer of mild steel, bright finised complete all as specified and directed.
S&F L band size 50 mm complete all as specifed and directed.
S&F Auto closing projected type hinges ( Al- Bihari ), Stainless steel, bright finish including steel screw etc complete all as specified and directed.
S&F Brass Locks 2 levers, cupboard, grade I, size 50 mm complete all as specifed and directed.
M&L PVC Sheet wall panneling of solid thickness 5 mm consisting of pannels of desired size stuck on inner frame work of 50 mm wide strips of 5mm thick prelam PVC sheet. The panel & strips shall be of 600 Kg/cbm density manufactured by ISO-9000 certified companyusing 65 mm long M.S screw shall not more than 200mm. A Groove of 2mm may be left at the joint of two panels for asthetic looks.The exact size of the panels and coorspondingly of the grid may vary depending on the size of the wall. Optionallya U Channel at top, bottom and side edges and strips of 5mm thick PVC sheet of width 75 mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cementcomplete all as specified and directed Make: Rajsheree Note: The above work excute necessary fittings and scafolding for heighted site.)
Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles .
M & L vitrified ceramic tiles double charged 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed.
-ditto-above item but on vertical surfaces such as skirting incl incl including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of size 350x450x7mm/450x350x7/ 8mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15cm thickness (above or below ground floors) complete all as specified and directed
M & L 75 mm thick for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in subbase for laying floor finishes complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest (excluding flushing cistern and flush pipe) & including CI trap & connecting fitting as required set in plain cement concrete (1:3:6) type C-1 and connecting to flusing cistern and trap & connecting fittings as required and making good to floor, complete all as specified and directed.
S&F in repair white vitreous China wash down water closet pan (pedestal) pattern, and trap (excluding) fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. with and including plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair vitreous china wash hand basin (flat back) of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, MS brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed.
S&F in repair soap dish brass, chromium plated, fancy type fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed.
S&F in repair bib taps brass fancy type, brass,chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair pillar taps sawan neck ( chrome finish), brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair fancy type angular stop cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S&F in repair Stop valves 15 mm bore fancy type, CP with long shank & cup (conncelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions
Hacking out old broken glass of any size,thickness,size, quality or description from metal frame including punching or drilling out old glazing pins/springs clips and providing and fixing new ones.
M&L for 4 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane(work will be carried out for 2nd to 6th floor) complete all as specified and directed.
S&F 4mm thick figureed glass , pin headed type and glazing with oil putty in squares of any description not exceeding .5 sqm in each pane (work will be carried out upto 4th floor) complete all as specified and directed.
Taking down shutters of aluminium of any description exc.1 sqm and not exc. 2 sqm each, resecuring and easing, adjusting and refixing in the same opening complete all as specified.
Taking down shutters of aluminium of any description exc. 2 sqm each, resecuring and easing, adjusting and refixing in the same opening complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from frame) exc. 1.50 sqm and but n exc 4 sqm each complete all as specified and directed.
S&F Powder Coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary jointing cleats/ glazing clips, rubber neoprene packing, handles 2 Nos in each door , locking arrangment, aluminium snap beading screw etc, complete all as specified and directed. ( minimum thickness of powder cated should be 50 micron)
S&F Powder Coated aluminium window and ventilator shutters side hung type without sash bars, , aluminium section weighing 0.55kg/m including necessary jointing cleats/ glazing clips, rubber neoprene packing, anodised aluminium snap beading , screws, anodised aluminium fittings such as peg stay 150mm long (1 No) hinges type B-21 100mm long ((2 Nos) suitable handle (1 No) complete all as specified and directed.
S&F Powder Coated aluminium frame for doors, windows or partition including aluminium beading, hinges of required size,jointing cleats, screws, dash,fastners,plug for fixing with wall, columns etc complete all as specified.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified.
Taking down existing double action floor spring hydraulically regulated and Refixing only after necessary repairs, oiling & greasing etc in proper position with and including proper screw complete all as specified and directed.
S&F in repair aluminium (die cast) body door closer hydraulically regulated, designation No.3 universal type, suitable for doors shutters up to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete allas specified and directed.
Taking down existing door closer hydraulicially regulated and refixing after necessary repairs,oiling & greasing etc in proper position with and including proper screw complete all as speified.
Taking down chowkhats with shutters (without taking off shutters from frame) not exc. 1.50 sqm each complete all as specified and directed.
S&F powder coated aluminium sliding window two track with two glass shutters aluminium powder coated section aluminium cleat, PVC track, bearing, handle locking arangement, rubber beading etc complte fittings as approved. Note Size of aluminium section shall be under :- (i) Two track top and vertical - Jindal main-2010 section No 20829 or equivalent (ii) Two track bottom- Jindal main-2010 section No 20830 or equivalent (iii) Shutter vertical section- Jindal main- 2010 Section 20606 or equivalent (iv) Shutter top and bottom - Jindal Main-2010 Section 20604 or equivalent (v) Shutter vertical middle (interlock) -Jindal Main-2010 section 20605 or equivalent
M&L taking out drapery rod and supply and fixing polyester coloured venetian blind mounted qn doors windows with aluminium hanging channel with sliding wheel rope including all necessary fittings andfixture complete all as specified and directed
Taking down shutters of any description and make exc. 1 sqm and not exc 2 sqm each complete all as specified and directed.
S & F with wood free EPS,Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing,etc including 02 Nos handle, 02 Nos but hineges and 02 Nos tower bolts complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
S & F in repair 1.25mm thickness of laths steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, haps and staple and one shop coat of primer erected in position as indicated, complete : push pull or manual type complete all as specified and directed
S&F for framed work such as grills, gratings, etc.. With ends of bars shouldered and riveted, or forged into spikes, framed guard bars, barred iron doors ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con-forming to Fe. 290. Gde-E-165. Note (ii) :- Work will be carried out upto 6 story in necessary scafolding and safety measures and labour insourance etc complete all as specified and directed
Fixing only 4.8 mm thick or any thickness of sheet glass ordinary quality in panes exc 0.50 sqm each fixed with & including rubber gasket in aluminium frame work complete all as specified and directed..Note :- Old glass retrieved under item no 23 above shall be reused
S&F in repairs mortice lock, vertical type of size 100 mm with brass body 2 lever complete all as specified.
S&F in repair chromium plated brass hand ablution health fauset with 1.50 meter long flexible tube fancy type with necessary brass nuts & rubber washers cover with chromium plated spring complete all as specified and directed.
S&F in repair 100mm dia cast Iron floor trap, with CP grating including jointing to waste pipe with solvent cement and fixed in cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) complete all as specified and directed.
S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed
S&F PVC connection 600 mm long suitable for 15 mm GI pipe with two brass nuts & rubber washers complete all as specified and directed.
S&F in repairs PVC waste pipe flexible type 32mm dia suitable for coupling 32mm,610mm long for WHB/Sink complete all as specified.
S & F tubular towel rail 20mm dia 600mm long of brass chromimum plated complete all as specified and directed
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20 mm dia pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 15 mm dia pipes complete all as specified and directed.
S&F for laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F for laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills sunshades, shelves lintels etc and cutting chases for concealed water pipe etc and making good cutting not exc 10cm.complete all as specified and directed.
Disconnecting & taking down existing water tank of capacity exc 500 liter and not exc. 1000 liter and removing from site complte and S&F rotational moulded polyethylene water storage tanks 1000 lts capacity three layer (cylindrical vertical with closed top) hoisted with and including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed in position all as per SSR Part I complete all as specified & directed.
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys , scrubing down with water etc, complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete /brick surface in cement mortar 1:6 finished fair and even as in wall complete all as specified and directed.
M&L for Rendering 10 mm thick on fair faces of concrete /brick surface in cement mortar 1:3 finished even and smooth without using extra cement as in ceiling and similar other work complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only under respective item of sch A.
M&L two coat of oil bound distemper of required tint on newly plastered surfaces of wall after prepration of surface and over a coat of 3 mm thick wall care puttty complete all as specified and directed.
M&L three coat of white wash on newly plastered surfaces of ceiling including prepration of surface complete all as specified and directed
M & L for preparation of newly plastered surface and applying two coat of weather proof over one coat damproof over a coat of water proof primer on walls complete all as specified.
M&L for Complete removal of existing treatment of old surface of wall / ceilling and washing rubbing down and stoping of distempered and painted surface of wall and applying two coats of weather proof on one coat of damproof over a coat of water proof primer complete all as specified and directed.
S&F in repair PVC water tank covers screw head type including four Nos of PVC nut and bolt in existing PVC water tanks of Cap 500 ltrs to 1000 ltrs cap with fixing arrangement complite all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on roof surface including mixed with WPC as per manufacturer's instruction's and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for separately as supply only under respectiveitem of sch 'A'.
M&L for taking down/dismantling of existing roof treatment of any description such as PCC Padding/ Coba treatment/ mud phuska/Lime conc terracing including screed bed etc. Hessian base felt/tar felt etc. (any type and thickness) complete all as specified & directed.
Removal of demolished materials to a distance exceeding 250 Mtr but not exceeding 500 Mtr and deposting where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed .
M & L for water proofing treatment on roof slab including picking ,sweeping ,clean and washing down with water to remove dust & providing water proofing treatment described as under :- (a) Surface preparation and treating construction joints, filling of honey combs,preparation of coving ( if required ) with Asian paints smartcare Repair Mortor and Asian Smartcare General purpose Grout of Asian paint or equivalent product of THERMAX / FOSROC . (b) Cleaning the surface and appling Asian PU Magnum primer Resin & hardner of Make Asian paints or eqivalent product of THERMAX / FOSROC on the cleaned surface. (c) Appling Asian Smartcare PU Magnum of Make Asian paints in Two ( 2 ) layers ( PU Magnum per coat should be minimum of 600 gms per Square meter or equivalent product of THERMAX / FOSROC. ( d). Ponding test of 72 Hrs and no leakage/ seepage observed. Any rectification to be done at the cost of contractor repeating above stepsof application. (e) . The work shall be carried out complete as per manufacturer's specification and application methodolgy. (f) . Execution to be done with authorised applicator of the manufacturer and company back gurantee to br given by the contractor after completion of water proofing work befor payment. work will be executed in Smart Assurance System of manufacturer company of Asian/ Epoxy/ Polymer chemicals.
Supply only Liquid water proofing compound ISI Marked (used 200 ml per bag of cement) complete all as specified and directed.
M&L for removing the plants/ vegetation upto Six story height including penefreated roots complete and injecting chemical GLYPHOSPHATW 41% SL 20 ml or till refusal by makimg cut/ injection in the stem of plant 30mm C/C spraying with solution (25ml Glyphospoto 41% diluted with one litre water) including necessary scaffolding etc wk will be carried out upto 6 th storey complete all as per specification and directions of the Engineer-in-charge.
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch.
All as per Srl item No 75 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches omplete all as specified and directed.
All as per Srl item No 75 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.omplete all as specified and directed.
All as per item No 75 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete.
All as per item No 75 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Note for item 75 to 78 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs . (ii) Rate for modular metal flush boxes ,inner and outer plate with frames are deemed to be included in the quoted rate by contractor for above items. (iii) Fittings like Modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iv) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade (v) Make of cable : Finolex /Havells/ Poly cab as approved by GE.(vi) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE.
S&F Modular switch piano single pole one way 6 amp complete. Make -Legrand / Anchor Penta / Havells as approved.
S&F Modular switch piano single pole one way 16 amp complete. Make - Legrand / Anchor Penta / Havells as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete. Make -Legrand / Anchor Penta / Havells as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete. Make -Legrand / Anchor Penta / Havells as approved.
S&F ceiling rose 3 plates polycarbonate, isolated body complete. Make - Legrand / Anchor Penta / Havells as approved.
S&F modular fan step regulator 120 W 2 module complete. Make: Legrand / Anchor Penta / Havells as approved.
S&F LED tube light fitting batten with universal batten fitting suitable for single T8 LED lamps complete all as specified and directed. Make: DMLN1LT8-16 of C&G or euivalent in Philips/ Havells/CG
S&F LED tube light 16 Watt T8 double sided connection with built-in driver, THD not more than 10% all as per C&G cat ref no LGT8-16-865-2 or equivalent in philips/Havells as approved.
Supplying, fixing & testing recess mounting in built ,24 Watts,2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- C&G Cat Pt No LCTLRNE-24-FO-CDL or equivalent in Phillips/Havells as approved.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet. Make of SPN DB with MCB 20Amp - of Indo Asian/Legrand/Schneider as approved.
S&F triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp, 415 Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp as required. Make of MCB SP 16/20 Amp- of IndoAsian/Legrand/Seimens/Schneider Make of TPN DB with MCB 63Amp - of Indo Asian /Legrand/Schneider as approved.
M&L sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed.
M&L sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.50 Sqmm as earth continuity conductor complete all as specified and directed. Notes for item No. 19&20 : (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Finolex /Havells/Polycab/Gloster/L&Tas approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
M&L sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed.
M&L sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Notes for Item 22&23 here in above : (i) Four run of single core PVC cable with two run of earth conductor and one run of conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
S&F in replacement of vertical type load line distribution board ,double door, 4 way, AC 3 Phase 415 volt with TPN bus bar 250 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefitted masking sheeet,reversible door for IP 43-"IK 09 with metal door with provision for DPX3 160 MCCB as incomer and SP/TP MCB's as out going complete all as specified and directed by Engr-in-Charge. Make of VTPN DB:-IndoAsian cat Part No-811893 or equivalent make in Havells/L& T.
S&F in replacement of UNSV MCB distribution board SPN, 240 volts, 8 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Legrand/Havells/L&T/Schneider/ IndoAsian as approved
S&F in replacement of UNSV MCB distribution board SPN, 240 volts, 12 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Legrand/Havells/L&T/Schneider/ IndoAsian as approved Note for Item No.25-27.(i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing
Supply and fixed in replacement of UNSV MCCB 4 pole,160 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with adjustable thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian cat part No. 830295 or equivalent in seimens / Schinder as approved by GE.
All as per item No 98 above but, MCCB 4 pole ,100 Amps Complete all as specified and directed. Make- IndoAsian cat part No. 830272 or equivalent in seimens / Schinder/ IndoAsian as approved by GE .
All as per item No 98 above but MCCB 4 pole,63 Amps Complete all as specified and directed. Make- IndoAsian cat part No. 830330 or equivalent in seimens / Schinder/ IndoAsian as approved by GE.
S & F in replacement of unserviceable MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 40 amps complete all as specified and directed.Make - IndoAsian cat ref no 811152 or equivalent in Hager or Schneider as approved.
S & F in replacement of unserviceable MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811122/24/26/27/28/29 or equivalent in Hager or Schneider as approved.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to GI strip 32x6 mm as earthing lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.
S&F 25 mm dia rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surfaces of following sizes:-
S&F modular switch socket combination universal type 6/16 Ampswith box (2 hole complete with suitable connection with 2x2.5sqmm and 1x1.5sqmm single core cable length upto 01 mtr Make Legrand/Anchor Penta/Crabtree as approved.
S&F modular switch socket combination universal type 6Amps with box (2 hole complete with suitable connection with 2x2.5sqmm and 1x1.5sqmm single core cable length upto 01 mtr Make Legrand/Anchor Penta/Crabtree as approved.
M/S P K ARORA
SHREYA INFRA DEVELOPER & CONSTRUCTION COMPANY
M/s Arora Sales Corporation
M/S WASEEM KHAN CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .