| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC PATEL NAGAR PO BHURKUNDA DISTT RAMGARH PIN 829106 | BHURKUNDA | RAMGARH | JHARKHAND | 829106 | L1 | Accepted-AOC As per NIT | |
| 2 | L2₹3.9 L+₹69,499.50 (21.9%)Rejected-Finance AT PO BHARECH NAGAR SANDI DISTT RAMGARH JHARKHAND 829117 | BHARECH | RAMGARH | JHARKHAND | 829117 | L2 | Rejected-Finance As per NIT | |
| 3 | L3₹4.3 L+₹1.2 L (36.5%)Rejected-Finance AT SUNDER NAGAR PO BHURKUNDA DT RAMGARH JHARKHAND 829106 | BHURKUNDA | RAMGARH | JHARKHAND | 829106 | L3 | Rejected-Finance As per NIT | |
| 4 | L4₹4.9 L+₹1.7 L (54.7%)Rejected-Finance TEACHERS COLONY RANIBAG DIST RAMGARH JHARKHAND 829 122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L4 | Rejected-Finance As per NIT |
Tender Value
₹4.7 L
EMD Value
₹5,900
Closing Date
19 Aug 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
STAFF OFFICER ENM
CRS BARKAKANA
Repairing/ Replacement of four pole structure of 3.3KV Overhead Power line inside CRS Barkakana.
2024_CCL_314740_1
CRS/BRK/SO(EnM)/ NIT/2024-25/18
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
CRS BARKAKANA
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
7 Dec 2024
9 Aug 2024
20 Aug 2024
9 Aug 2024
19 Aug 2024
9 Aug 2024
9 Aug 2024 - 16 Aug 2024
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required. Above 10.00 metre and upto 12.00 metre.
Supplying and erection of galvanized stay set for 11KV overhead lines complete with 19/20 mm dia x 1.8 mtr. Long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm thick, thimble, stay clamp, turn buckle(20 mm x 600 mm),7/4.00 mm dia G.I. stay wire and 11 KV strain insulator etc. in cement concrete 1:3:6(1cement :3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying and erection of a set of cross bracing FRL Same work for 11KV overhead line double pole structure having four members fabricated out of 50mm x 50mm x 6mm angle iron to form a rectangle of minimum size 1400mm width x 2500mm height, complete with 50mm x 6mm M.S. flats iron clamps, bolts & nuts including drilling holes for insulator pin, bolts and nuts etc. and painting with primer and finish paint as required.
Supplying of two length of channel iron 75mm x 40mm x 6mm (7.14 kg/mtr) double pole cross arm for three wire 11KV overhead line conductor complete with through bolts and nuts for clamping to the pole s, 50 mm x 6mm MS flats welded on one side to the channel iron and with bolts and nuts on the other side to channel iron arms together, including drilling holes for insulator pins/fitting, bolts, nuts and washer etc and painting with primer and finish as required.
Erection of double pole 3 wire cross arm for 3.3/11KV over head lines as required.
Supplying and erection of 11KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11Kv Disc insulator for 11KV over head line with galvanized insulator fittings ,ball and socket type and complete with galvanized strain clamps, bolts and nuts washers etc. as required
Erection of ACSR conductor of 7/3.35mm to7/4.00mm diameter and above including binding etc. as required.
Supplying and erection of three piece nonlinear resistor type lighting arrestor suitable for 3 wire ,11KV overhead line with rated voltage 9KV (rms) with a nominal discharge current rating of 5 kA and complete with galvanized clamping arrangement, G.I bolts, nuts ,washers etc. as required .
Earthing with copper earth plate 600 mm x 600mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connection etc. as required.
Providing and fixing 4.00 mm copper wire on surface or in recess for loop earthing etc. as required.
Dismantling of over head lines comprising of copper/aluminum overhead conductor, GI wire, cross arms, insulators etc. as required.
Dismantling of Pole/street light standard strut embedded in cement concrete foundation etc. as required.
Supply and Erection of 11 KV Isolator (Gang Operating switch) 400 Amp.
Total impact of GST for the purpose of CTC
RELIABLE AGENCY
M/S B.N. PANDEY
M/S SURENDRA PRASAD AND SONS
techsummary_326177.pdf
PDF • 0.32 MB
finsummary_326177.pdf
PDF • 0.32 MB
LOA.pdf
PDF • 0.77 MB
finance_326177.pdf
PDF • 0.25 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .