Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹96,100Accepted-AOC MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | 1 | Accepted-AOC L1 | |
| 2 | 2₹97,000+₹900 (0.94%)Rejected-Finance | 2 | Rejected-Finance OTHER THAN L1 | |
| 3 | 3₹1 L+₹3,900 (4.06%)Rejected-Finance 18C SADH NAGAR PALAM COLONY SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | 3 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
Closing Date
18 Jan 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) LUCKNOW
GE (EAST) LUCKNOW
Addn/Altn /improvement of electrification in bldg no 180/01 defence colony under GE(East) Lucknow
2021_MES_411945_1
3001/128/E3
Limited
Miscellaneous Services
Works
60 days
GE (EAST) LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
2 Feb 2021
12 Jan 2021
19 Jan 2021
12 Jan 2021
18 Jan 2021
12 Jan 2021
30 days
Amount
(i) Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.. - 61 Per Point (ii) Taking down carefully copper/aluminium sub main wiring from existing concealed PVC conduit complete and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall all as specified. - 107 RM M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked not less than 19.5 mm / 20 mm dia along with conduit fixing accessories and with pressed steel terminal box for mounting of hylem sheet plates of thickness 1.6mm thick terminal boxes concealed on wall/fllor/ceiling, with 3 mm thick laminated sheet top cover ISI marked. Make: Hylum for fixing of switches/socket/regulator with brass screws cup washer complete including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing one and white wash/colour wash all as specified and as directed by Engineer- in- Charge. - 35 Per Point (iv) All as per item No 3 above but 5 Amp socket outlet, independent.. - 10 Per Point (v) All as per item No 3 above but on the same board.. - 10 per point (vi) All as per item No 3 above but for one light point controlled by two, 2- way switch.. - 01 per point (vii) All as per item No 3 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly.. - 05 Per point (viii) S&F switch piano flush type 5 Amp one way, single pole, 240 volts all as specified. . - 55 Each (ix) S&F switch piano type 5 Amp, 2 way, 240 volts all as specified. . - 02 Each (x) S&F in repairs socket outlet 5 Amp, 5 Pin, 240 volt, flush type, all as specified and directed. - 20 Each (xi) S&F in repairs switch socket outlet, two in one 5 & 15 Amp, 6 pin, multipurpose combination, all as specified. . - 05 Each (xii) S&Fixing in Replacement ceiling rose two or three terminals surfaces bakelite65 x 50mm size all as specified. Make :- Anchor - 35 Each Continued to next coloumn
(xiii) S&Fixing in Replacement lamp holder bakelite with back plate suitable for batten fittings all as specified. Make: Anchor- 03 Each (xiv) S&F ceiling fan regulator electronic Stepped type for 1200/1400 mm sweep. Make:- Anchor/SSK/Bajaj. - 03 Each (xv) Supply and fix in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : IGP131LT8-16& LT8-20-865-2 or equivalent in Havells, Cat No : REGALBATTENT8UPT01X22WSSBS & PHOTONULTRA1213T8SSTL20WLED865SPC,philips cat no TMC 100 1xT LED /MAS LED tube 1200 mm 18 w 865 T8 I - 2100 Lumen - 07 Each (xvi) Supply and fix in replacement of LED security light fitting 45 watt, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed. Make : Crompton, Cat No : LSTP-45-CDL or equivalent in Havells/ philips - 02 Each (xvii) Supply and fixing as in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge.Make-Legrand Cat No-607711 or equivalent grading ISI marked. - 02 Each (xviii) Supply and fix Single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed. Make - Legrand Cat No-6078 41 or equivalent approved make. - 01 Each (xix) Supply and Fixing in replacement MCB, single pole, 240 Volts, of capacity (6-32 Amps) as ordered breaking capacity 10 KA. Make-Legrand Cat No-603231 to 603237 or equivalent grading ISI marked. - 04 Each (xx) Supply and fixing in repair MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as directed. Make-Legrand Cat No-603272 to 603274 or equivalent grading ISI marked.. - 01 Each (xxi) M&L for sub main wiring with PVC insulated unsheathed cable with copper conductor multi strand two single core 6 sq mm and one run of 4 sq mm PVC insulated green colour earth continuity wire drawn through in and including 25 mm dia PVC concealed conduit all as specified. Make- Anchor /Seiko /Havells /Paragon /finolex/HPL/Plaza. - 20 RM (xxii) All as per item No. 24 but two single core 4 sqmm including 2.5 Sqmm PVC insulated unsheathed stranded copper conductor as earth wire all as specified. Make- Anchor /Seiko /Havells /Paragon /finolex/HPL/Plaza. - 63 RM (xxiii) All as per item No. 24 but two single core 2.5 sqmm including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor as earth wire all as specified. Make- Anchor /Seiko /Havells /Paragon /finolex/HPL/Plaza - 24 RM (xxiv) Renewal of Earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr, deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0mm dia by means of nut, bolts, check nut 7 washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20mm dia GI wire meshed funnel alternate layer of char coal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation & earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR part-I 2009 print and as directed. . - 01 Each
S K Stationers
M/s Sharma Trading Co.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .