| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.5 LAccepted-AOC DOOR NO 19 OPP ESI DISPENSARY MAR GREGORIOUS ROAD ALUVA ERNAKULAM 683101 | ALUVA | ERNAKULAM | KERALA | 683101 | 1 | Accepted-AOC L1 | |
| 2 | 2₹10.3 L+₹76,800 (8.07%)Rejected-AOC 66 4743 M G ROAD NORTH END ERNAKULAM ERNAKUALM KERALA 682035 | ERNAKULAM | KERALA | 682035 | 2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical 3724 OPP KALI BARI MANDIR OPP KALI BARI MANDIR AMBALA CANTT HARYANA 133001 | AMBALA | HARYANA | 133001 | - | Rejected-Technical Technically not Feasible |
Tender Value
Refer Docs
EMD Value
₹27,500
Closing Date
7 Jan 2021, 3:00 pmClosed
Director SRI KWA
State Referral Institute for Water Quality Nettoor Ernakulam 682040
JJM 2020 21 Setting up Up gradation Operation of Laboratories for WQMS Procurement of 16nosMicro processor based bench top pH meter for various Quality Control Laboratories of Kerala Water Authority
2020_KWA_401495_1
10/ 2020-21 / SRI / NTR
Open Tender
Laboratory and scientific equipment
Item Wise
45 days
As per Anexure A of NIT
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,500
₹27,500
Yes
SRI Nettoor
27 Aug 2021
21 Dec 2020
11 Jan 2021
21 Dec 2020
7 Jan 2021
21 Dec 2020
21 Dec 2020 - 26 Dec 2020
28 Dec 2020
Amount
JJM-2020-21-Setting up / upgradation / operation of Laboratories for WQM&S- Procurement of 16 nos Micro Processor based bench top pH Meter for various Quality Control Laboratories of Kerala Water Authority
Micro processor based bench top pH meter with the following specifications pH:- Range: 0.000 to 14.000 Resolution: 0.1/0.01/0.001 pH Repeatability: ± 0.003pH Accuracy:± 0.003 pH Cal.Points 5 points Buffer options: USA, NIST, Custom ORP:- Range: ±1999.9 mV Resolution: 0.1 mV Repeatability:± 0.2mV Accuracy:± 0.2mV Temperature Range: 0.0 to 100°C Resolution: 0.1°C Repeatability: ±0.4°C Accuracy: ±0.4°C Electrode specification:Double junction toughened glass electrode with filling solution;Shall provide ATC; Meter and electrode shall be of same manufacturer; Meter Features (i)Off set/slope should be displayed;(ii) Should have Data logging facility;(iii)Output RS232/USB (iv)Memory 500 data sets minimum;(v)Power 230V ±10%;(vi)Buffer set : USA pH 4.01, 7.00, 10.01 minimum 100ml each shall be supplied with the instrument;(vii)Should provide hard copy of user manual with instrument and electrode specification ;(viii) Compliance: GLP with NABL Calibration certificate;(ix) IQ/OQ/PQ documentation shall be provided (x)Warranty: 3 years for the meter and 1 year for the electrode;
Laboratory Equipment Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .