| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-Finance PLOT NO 113 GURUSANGAT DARBAR ROAD SINDHI COLONY KHAMLA NAGPUR 440025 | NAGPUR | MAHARASHTRA | 440025 | ₹1.2 Cr | L1 | Accepted-Finance Found L1 |
| 2 | L2₹1.2 Cr+₹6.3 L (5.36%)Rejected-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹1.2 Cr+₹6.3 L (5.36%) | L2 | Rejected-Finance Not found L1 |
| 3 | L3₹1.4 Cr+₹18.6 L (15.7%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹1.4 Cr+₹18.6 L (15.7%) | L3 | Rejected-Finance Not found L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
20 Jun 2024, 11:00 amClosed
AGM(E-E)
AAI, Birsi Airport, Gondia
Bi-Annual Maintenance of E and M Installations and CMC of Split AC and Water Cooler etc. at NIATAM, Gondia for the year 2024-26.
2024_AAI_196985_1
AAI/Gondia/E-E/2024-25/NIT-03
Open Tender
Electrical Works
Item Rate
730 days
AAI, Birsi Airport
Please refer Tender documents.
19 documents required · 19 mandatory
₹1,180
Yes
₹2.8 L
Yes
31 Jul 2024
31 May 2024
21 Jun 2024
31 May 2024
20 Jun 2024
31 May 2024
31 May 2024 - 6 Jun 2024
Amount
Annual Operation & Maintenance of various Electrical Installations of NIATAM such as Institute, Mens hostel, Womens Hostel Staff Houses, Canteen, AAI Residential colony, DG Sets up to 500 KVA with AMF Panels, Power Supply Systems, 11KV Sub-Station, Water Supply & Pump House, Street Lights, Parking Lights, Internal & External installations of Power House etc. including repair & maintenance, Faults/ breakdown rectifications, ensuring serviceability/ Satisfactory working conditions of the system, attending complaints as per scope of work given in special conditions of contract on all days including Sunday & Holidays (i.e in three shifts daily, each shift of 8 hours) etc. complete as required.
Rewinding Servicing repairing of ceiling fan/ wall fan including replacement of bearings if required and to & fro transportation etc complete as required (Dismantle Material belongs to contractor).
For 1st Year
For 2nd Year
Rewinding Servicing, repairing of Exhaust fan/ Air Circular fan of size upto 450 mm sweep i/c replacement as bushes/bearings if required and to & fro transportation etc complete as required. (Dismantle Material belongs to contractor)
For 1st Year
For 2nd Year
Rewinding of the motors (Capacity of upto 2 HP), Which are suitable to operate on 415V, 50Hz, 3Ø AC supply, with suitable gauge copper wire i/c warnishing, bearing if required etc as required i/c transportation from site to workshop & back to site. (Dismantle Material belongs to contractor).
For 1st Year
For 2nd Year
Rewinding of the motors (Capacity from 3 HP and upto 5 HP), Which are suitable to operate on 415V, 50Hz, 3Ø AC supply, with suitable gauge copper wire i/c warnishing, bearing if required etc as required i/c transportation from site to workshop & back to site. (Dismantle Material belongs to contractor).
For 1st Year
For 2nd Year
Lifting & Lowering of submersible pumps of various capacities (up to 5 HP) due to defect in existing pump / pump choked in existing borewell on urgent basis within a short notices including connection of cables jointing of cables etc. with successful testing & commissioning complete as required.
For 1st Year
For 2nd Year
Repair and rewinding of submersible pump motor set up to 5 HP capacity. Job include transportation of motor dismantling and rewinding with the same gage insulated copper wire including replacement of all the internal worn out/defective parts i.e bushes, impellers, sleeves, upper and lower bush sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required.
For 1st Year
For 2nd Year
Inspection, Servicing and Testing of 3 Pole, 630Amp, 11 KV Vacuum Circuit Breakers (Make:Siemens) including carrying out tests & preventive maintenance through Manufacture OR Authorised Service agent and submission of test reports. (01 Preventive maintenance once in year and 4 Breakdown calls)
For 1st Year
For 2nd Year
Inspection, servicing, setting, calibration and testing of IDMT relays (Make- ABB, Model- NI40) (set of 2 over current + 1 earth fault) i/c carrying out tests & preventive maintenance through authorised service agent and submission of test reports. (01 Preventive maintenance once in year and 4 Breakdown calls)
For 1st Year
For 2nd Year
Inspection, servicing, setting, calibration and testing of Microprocessor based numerical relay (Make L&T, Model MC31A, MC 61A) with O/L, E/F and S/C protections for 11KV panel i/c carrying out preventive maintenance through authorized service agent and submission of test reports. (01 Preventive maintenance once in year and 4 Breakdown calls)
For 1st Year
For 2nd Year
Inspection, servicing, setting, calibration and testing of auxiliary and tripping relays (Make: AREVA, Model: YCGF, VAJ) including carrying out preventive maintenance through authorised service agent and submission of test reports. (01 Preventive maintenance once in year and 4 Breakdown calls)
For 1st Year
For 2nd Year
Inspection, Testing & preventive maintenance of 11 KV Potential transformers including carrying out preventive maintenance through authorized service agent and submission of test reports. (01 Preventive maintenance once in year and 4 Breakdown calls)
For 1st Year
For 2nd Year
Inspection, servicing & testing of Air circuit breakers Make GE, Capacity 1600A including carrying out the testing and preventive maintenance through authorized service agent and submission of test reports. (01 Preventive maintenance once in year and 4 Breakdown calls)
For 1st Year
For 2nd Year
Inspection, servicing & testing of Air circuit breakers Make L&T, Capacity 800A including carrying out the testing and preventive maintenance through authorized service agent and submission of test reports. (01 Preventive maintenance once in year and 4 Breakdown calls)
For 1st Year
For 2nd Year
Filtration and dehydration of transformer oil for the following installations including testing of the Oil for dielectric strength before and after filtration as per IS: Specification and submission of of the report of B.D.V. Test and Chemical analysis of the oil to determine the level of acidity as per IS: Specification and cleaning of breather and providing fresh charges of Silica Gel to the transformers, Supplying and replacing corroded nuts and bolts, gaskets and washers etc. (Transformers oil for topping up will be supplied separately.) (a) Make: Crompton Greaves, Capacity 1000 KVA, Oil Capacity 580 Ltrs.]
For 1st Year
For 2nd Year
Supply of tested transformer oil for topping up in transformers as required.
Execution of work as per CPWD DSR 2022 (E&M). NOTE: The firm has to quote/upload the percentage above / below (+/- % on the quantity mentioned against BOQ item No. (7) directly in the form of multiplying factor in the rate column as clarified below: For example, “if agency desired to quote 5% above on CPWD DSR-2022 (E&M) rates, the rate column shall be filled as 1.05. If agency desired to quote to 5% below on DSR-2022 rates, the rate column shall be filled as 0.95.” ( DSR-2022 rates will be worked out by excluding GST component).
Annual comprehensive maintenance of 4.0 TR Cassette/Tower type airconditioners of different makes located at NIATAM including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out monthly servicing and also includes replacement of damage insulation, taping etc., painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions complete etc. as required.
For 1st Year
For 2nd Year
Annual comprehensive maintenance of 3.0 TR Mega split/High wall/Tower type airconditioners of different makes located at NIATAM including replacement of faulty compressor and providing all necessary consumables and spares parts, carrying out monthly servicing and also includes replacement of damage insulation, taping etc., painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions complete etc. as required.
For 1st Year
For 2nd Year
Annual comprehensive maintenance of 2.0 TR split airconditioners (Inverter and Non Inverter Type) of different makes located at NIATAM including replacement of faulty compressor and providing all necessary consumables and spares parts and also includes replacement of damage insulation, taping etc.carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions complete etc. as required.
For 1st Year
For 2nd Year
Annual comprehensive maintenance of 1.5 TR split airconditioners (Inverter and Non Inverter Type) of different makes located at NIATAM including replacement of faulty compressor and providing all necessary consumables and spares parts and also includes replacement of damage insulation, taping etc.carrying out monthly servicing, painting of outdoor units once a year and fault rectification including gas charging, labour charges as required and as per special conditions complete etc. as required.
For 1st Year
For 2nd Year
Shifting and Re-Installation of Split type Airconditioners of capacity of 1.5TR / 2.0TR including Gas changing, Pressure Testing and Commissioning etc. complete as required.
Shifting and Re-Installation of Split type Airconditioners of capacity of 4.0TR / 3.0TR including Gas changing, Pressure Testing and Commissioning etc. complete as required.
Supply and fixing 20mm dia rigid PVC pipes along with necessary accessories & insulation on surface / recess for drain water outlets of AC units etc. complete as required
Supply and fixing of copper refrigerant piping of size 1/2" and 1/4" comprising suction and discharge pipes complete with nitrile rubber insulation sleeves, brazing including providing of clamps etc. complete as required.
Supply and fixing of copper refrigerant piping of size 5/8" and 3/8" comprising suction and discharge pipes complete with nitrile rubber insulation sleeves, brazing including providing of clamps etc. complete as required.
Dismantling of existing 4.0TR/3.0/2.0/1.5 TR Split AC Units with acceerious including loading and un loading complete etc. as required upto AAI store.
Annual Comprehensive Periodical maintenance of Water cooler Units (Including compressor) of 40/80 ltr capacity, 1Ø, 230 V, 50 Hz, of different makes including stabilizer(if any) installed at different locations including providing all necessary consumable, refrigerant Gas and spares etc.
For 1st Year
For 2nd Year
Annual Comprehensive maintenance contract of 1 No. U.V. water purifier (Make Hi-Tech) having flow rate 3 ltr per minute, comprising of U.V. lamps, Membrane Filter, Paper Filter, SMPS, etc. complete as required.
For 1st Year
For 2nd Year
Annual Comprehensive maintenance contract of KENT RO (Model- Kent ACE) having storage capacity 7 Ltr., comprising of U.V. lamps, Carbon filter, Sediment Filter, Membrane Filter, Post Carbon Filter, Pre Carbon Filter, SMPS, CC Kit Pump etc. complete as required.
For 1st Year
For 2nd Year
ABHISHEK INTEGRATIONS LIMITED
Manish Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .