Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAdmitted-Finance | ₹8.9 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S CHOUDHARY ELECTRICAL WORKS L1 |
|---|---|---|---|---|
| 1.00Supply of Equipments | ||||
| 1.01 | Single phase, 50c/s 36 KV Current Transformers (1200-600-300/1-1-1-1A) ,31.5 KA for one second, rated dynamic current 31.5 KA (peak), Class A insulation, Burden 20VA, 2 NO PS Core 01 No 5P20 01 No 0.2S Class, galvanized tank including first fill of Transformer oil plus 20% extra and all accessories, auxiliaries, connectors etc | 3 | No | 1,50,000 ₹4,50,000 Lowest |
| 1.02 | Single Phase 50c/s, outdoor metal oxide gapless type, 30 KV(rms) Surge Arrestor class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries, connectors. | 3 | No | 1,10,000 ₹3,30,000 Lowest |
| 1.03 | T Clamps 0.4/0.4, made of Aluminum Alloy and shall comply in all respects with IS:5561-1970 (latest edition) | 80 | No | 1,000 ₹80,000 Lowest |
| 1.04 | Single Suspension Fittings For Single Zebra shall have minimum failing load of 50% ultimate strength of conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN | 24 | No | 250 ₹6,000 Lowest |
| 1.05 | Spacers for twin ACSR Conductor | 30 | No | 100 ₹3,000 Lowest |
| 1.06 | Single Suspension Fittings For Twin Zebra shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN | 12 | No | 100 ₹1,200 Lowest |
| 1.07 | Bimetallic Pad Clamp Twin 0.4, made of Aluminum alloy and shall comply in all respects with IS:5561-1970 (latest edition) | 25 | No | 100 ₹2,500 Lowest |
| 1.08 | Vacuum Bottle for VCB (02 Nos), Spring charging motor (01 No), Tripping / closing coils , 110 V DC (02 Nos. each) of CGL make 33 KV Circuit Breaker | 1 | LS | 200 ₹200 Lowest |
| 2.00Erection, Testing and Commissioning of Equipments | ||||
Tender Value
₹9.6 L
EMD Value
₹19,100
Closing Date
6 Aug 2026, 2:00 pmClosed
Executive Engineer, TLMD-VIII, JKPTCL Jammu
Executive Engineer, TLMD-VIII, JKPTCL Jammu
Providing Spares for 33 KV Dedicated MES Bay at Grid Sub Station Rajouri and Feeding the Bay from 50 MVA Power Transformer
2026_PDD_315006_1
TLMD-VIII/J/T/14 of 2026-27 Dated 06.07.2026
Open Tender
Electrical Works
Turn-key
90 days
RAJOURI
AS PER NIT AND SBD
2 documents required · 2 mandatory
₹1,180
Executive Engineer, TLMD-VIII, JKPTCL Jammu
₹19,100
Executive Engineer, TLMD-VIII, JKPTCL Jammu
31 Aug 2026
7 Jul 2026
8 Aug 2026
8 Jul 2026
6 Aug 2026
8 Jul 2026
13 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply of Equipments | |||||
| 1.01 | Single phase, 50c/s 36 KV Current Transformers (1200-600-300/1-1-1-1A) ,31.5 KA for one second, rated dynamic current 31.5 KA (peak), Class A insulation, Burden 20VA, 2 NO PS Core 01 No 5P20 01 No 0.2S Class, galvanized tank including first fill of Transformer oil plus 20% extra and all accessories, auxiliaries, connectors etc | 3 | No | - | - |
| 1.02 | Single Phase 50c/s, outdoor metal oxide gapless type, 30 KV(rms) Surge Arrestor class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries, connectors. | 3 | No | - | - |
| 1.03 | T Clamps 0.4/0.4, made of Aluminum Alloy and shall comply in all respects with IS:5561-1970 (latest edition) | 80 | No | - | - |
| 1.04 | Single Suspension Fittings For Single Zebra shall have minimum failing load of 50% ultimate strength of conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN | 24 | No | - | - |
| 1.05 | Spacers for twin ACSR Conductor | 30 | No | - | - |
| 1.06 | Single Suspension Fittings For Twin Zebra shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN | 12 | No | - | - |
| 1.07 | Bimetallic Pad Clamp Twin 0.4, made of Aluminum alloy and shall comply in all respects with IS:5561-1970 (latest edition) | 25 | No | - | - |
| 1.08 | Vacuum Bottle for VCB (02 Nos), Spring charging motor (01 No), Tripping / closing coils , 110 V DC (02 Nos. each) of CGL make 33 KV Circuit Breaker | 1 | LS | - | - |
| 2Erection, Testing and Commissioning of Equipments | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
SBDmes.pdf
Tender Documents • 1.61 MB
BOQ_1020423.xls
BOQ • 0.29 MB
Extension3NIT14_2026-27.pdf
PDF • 0.48 MB
Extension2NIT14_2026-27.pdf
PDF • 0.48 MB
ExtensionNIT14_2026-27.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .