| 1 | L1₹30.9 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹30.9 L+₹4,230.15 (0.14%)Rejected-Finance 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L2 | Rejected-Finance L2 | |
| 3 | L3₹32.4 L+₹1.5 L (4.96%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹34.4 L+₹3.5 L (11.3%)Rejected-Finance NO 2 GF AKSHAYRAJ APARTMENT JUBILEE CIRCLE BHUJ 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹34.4 L+₹3.5 L (11.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | rajengineers L5 | Sukhi Electricals L7 | SURESH ELECTRICALS L3 | M/s super construction L6 | JAMNAGAR ELECTRIC AND MACHINERY CO L8 | jagdish machinery stores L1 | M/s. Ambabhai K patel L4 | MADHAV ENTERPRISE L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc and getting out, complete all as specified as directed by Engineer in Charge. | 1,369.3 | CUBIC METER | 270 ₹3,69,711 | 300 ₹4,10,790 | 205 ₹2,80,706.5 | 200 ₹2,73,860 | 415 ₹5,68,259.5 | 200 ₹2,73,860 | 246 ₹3,36,847.8 | 130 ₹1,78,009 Lowest |
| 2.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying of cables and erectioning of poles and getting out in any Hard /Dense soil complete all as specified as directed by Engineer in Charge. | 25 | CUBIC METER | 300 ₹7,500 | 350 ₹8,750 | 255 ₹6,375 | 250 ₹6,250 | 495 ₹12,375 | 600 ₹15,000 | 450 ₹11,250 | 180 ₹4,500 Lowest |
| 3.00 | Returning, filling in trenches any type of soil, including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified as directed by Engineer in Charge. | 824.11 | CUBIC METER | 65 ₹53,567.15 | 50 ₹41,205.5 | 90 ₹74,169.9 | 30 ₹24,723.3 Lowest | 140 ₹1,15,375.4 | 100 ₹82,411 | 80 ₹65,928.8 | 70 ₹57,687.7 |
| 4.00 | Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified as directed by Engineer in Charge. | 545.2 | CUBIC METER | 50 ₹27,260 | 60 ₹32,712 | 90 ₹49,068 | 40 ₹21,808 Lowest | 160 ₹87,232 | 150 ₹81,780 | 150 ₹81,780 | 70 ₹38,164 |
| 5.00 | Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment complete all as specified as directed by Engineer in Charge. | 410.79 | CUBIC METER | 450 ₹1,84,855.5 | 800 ₹3,28,632 | 715 ₹2,93,714.85 | 400 ₹1,64,316 Lowest | 600 ₹2,46,474 | 555 ₹2,27,988.45 | 550 ₹2,25,934.5 | 410 ₹1,68,423.9 |
| 6.00 | Supplying and laying un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm complete all as specified as directed by Engineer in Charge. | 22,560 | Each | 13.5 ₹3,04,560 | 18 ₹4,06,080 | 15 ₹3,38,400 | 14 ₹3,15,840 | 12 ₹2,70,720 Lowest | 18 ₹4,06,080 | 26 ₹5,86,560 | 13 ₹2,93,280 |
| 7.00 | Laying only old un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm ccomplete all as specified as directed by Engineer in Charge. | 6,000 | Each | 0.5 ₹3,000 Lowest | 1 ₹6,000 | 3 ₹18,000 | 1 ₹6,000 | 3 ₹18,000 | 3 ₹18,000 | 5 ₹30,000 | 0.5 ₹3,000 Lowest |
| 8.00 | Taking out / down old existing LT 1100 volt grade cables of size 2x16Sqmm, aluminium conductor, XLPE, armoured, removal to store for re-use or for credit, complete all as specified as directed by Engineer in Charge.
Note : Excavation shall be measured and paid for separately | 950 | RUNNING METER | 1 ₹950 Lowest | 5 ₹4,750 | 3 ₹2,850 | 1 ₹950 Lowest | 10 ₹9,500 | 5 ₹4,750 | 5 ₹4,750 | 3 ₹2,850 |
| 9.00 | All as per Serial Item No. 8 here-in-before but 16 Sqmm 4 Core size complete all as specified as directed by Engineer in Charge. | 750 | RUNNING METER | 1 ₹750 Lowest | 5 ₹3,750 | 3 ₹2,250 | 1 ₹750 Lowest | 10 ₹7,500 | 6 ₹4,500 | 5 ₹3,750 | 3 ₹2,250 |
| 10.00 | All as per Serial Item No. 8 here-in-before but 25 Sqmm 4 Core size complete all as specified as directed by Engineer in Charge. | 850 | RUNNING METER | 1 ₹850 Lowest | 5 ₹4,250 | 3 ₹2,550 | 1 ₹850 Lowest | 10 ₹8,500 | 7 ₹5,950 | 5 ₹4,250 | 5 ₹4,250 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR/ MAINT OF LT UG CABLES WITH ALLIED WORK AT VARIOUS LOCATIONS UNDER GE (AF) JAMNAGAR NO. 1
2025_MES_715230_1
8346/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
JAMNAGAR
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No 1
₹90,000
Yes
12 Sept 2025
18 Jun 2025
17 Jul 2025
18 Jun 2025
16 Jul 2025
2 Jul 2025
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc and getting out, complete all as specified as directed by Engineer in Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying of cables and erectioning of poles and getting out in any Hard /Dense soil complete all as specified as directed by Engineer in Charge.
Returning, filling in trenches any type of soil, including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified as directed by Engineer in Charge.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified as directed by Engineer in Charge.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment complete all as specified as directed by Engineer in Charge.
Supplying and laying un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm complete all as specified as directed by Engineer in Charge.
Laying only old un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm ccomplete all as specified as directed by Engineer in Charge.
Taking out / down old existing LT 1100 volt grade cables of size 2x16Sqmm, aluminium conductor, XLPE, armoured, removal to store for re-use or for credit, complete all as specified as directed by Engineer in Charge. Note : Excavation shall be measured and paid for separately
All as per Serial Item No. 8 here-in-before but 16 Sqmm 4 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 25 Sqmm 4 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 35 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 50 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 70 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 95 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 120 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 150 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 185 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 240 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 8 here-in-before but 300 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
Relaying, jointing, testing and commissioning, already taken out existing LT under ground cables XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor cross sectional area 16 Sqmm 2 core, 1100 volts grade, laid in trenches, along poles or passing through pipes or laid under floor or through/on walls etc, complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 16 Sqmm 4 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 25 Sqmm 4 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No.20 here-in-before but 35 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 50 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 70 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 95 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 120 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 150 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 185 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 240 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 20 here-in-before but 300 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm 2 core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified as directed by Engineer in Charge. Note: Returning filling & removal of earth, sand cushioning and bricks for protection of cable shall be measured and paid separately.
All as per Serial Item No. 32 here-in-before but 16 Sqmm 4 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 25 Sqmm 4 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 35 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 50 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 70 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 95 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 120 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 150 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 185 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 240 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
All as per Serial Item No. 32 here-in-before but 300 Sqmm 3.5 Core size complete all as specified as directed by Engineer in Charge.
Supply and laying / fixing , GI pipe light grade 100mm dia bore for cable protection fixed to pole/wall or laid under floor/roadv /pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified as directed by Engineer in Charge. Note: Boring of holes under road etc. shall be measured and paid separately.
All as per item No 44 here - in before but GI pipe 80mm complete all as specified as directed by Engineer in Charge.
All as per item No 44 here - in before but GI pipe 50mm complete all as specified as directed by Engineer in Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 2/4 core, 16 to 25 Sqmm complete all as specified as directed by Engineer in Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 35/50 Sqmm complete all as specified as directed by Engineer in Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 70/95 Sqmm complete all as specified as directed by Engineer in Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 to 185 Sqmm complete all as specified as directed by Engineer in Charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 240 to 300 Sqmm all as specified and as directed by Engineer-In-Charge. Note for item No 47 to 51:- Excavation,Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule
Disconnecting XLPE cable of any size from MCB/MCCB/Busbar chamber / LT cables etc for repair /replacment job and reconnecting cable after replacing worn out /damaged lugs, proper clamping, extended terminal link, repair to panel door replacement of door hinges, painting to disturbed surface complete all as specified as directed by Engineer in Charge.
Boring horizontally under roads/pavement/ hardstanding without disturbing the top surface by trench less technology using ultra sound technique and necessary machine including supply and fixing HDPE pipe of 90 mm dia(ISI Marked) suitable for 0.4 mpa working pressure for passing through the cables complete all as specified as directed by Engineer in Charge. (Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost).
MADHAV ENTERPRISE (BID ID -3352331)
SURESH ELECTRICALS (BID ID -3352008)
M/s. Ambabhai K patel (BID ID -3352332)
rajengineers (BID ID -3351326)
M/s super construction (BID ID -3352685)
Sukhi Electricals (BID ID -3351761)
JAMNAGAR ELECTRIC AND MACHINERY CO (BID ID -3358777)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .