Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.3 LAccepted-AOC NOT MENTIONED | L1 | Accepted-AOC accept | |
| 2 | L2₹64.2 L+₹5.9 L (10.1%)Rejected-AOC VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L2 | Rejected-AOC accept | |
| 3 | L3₹66.8 L+₹8.5 L (14.6%)Rejected-AOC | L3 | Rejected-AOC accept | |
| 4 | L4₹68.7 L+₹10.4 L (17.8%)Rejected-AOC | L4 | Rejected-AOC accept | |
| 5 | L5₹1.2 Cr+₹58.4 L (100.1%)Rejected-AOC | L5 | Rejected-AOC accept |
Tender Value
₹54.2 L
EMD Value
₹86,700
Closing Date
14 Sept 2021, 11:00 amClosed
EE
Jal Shakti Division Dehra
Pumping machinery
2021_HPIPH_52023_1
DHR-KNG02-728
Open Tender
Pumps/Motors
Item Rate
180 days
Dehra
Please refer Tender documents.
8 documents required · 8 mandatory
₹800
₹86,700
Yes
10 Jan 2022
7 Sept 2021
14 Sept 2021
7 Sept 2021
14 Sept 2021
7 Sept 2021
Amount
LWSS Rajiana Tripal (Submersible Pump set for Booster Stage i/c Automation) Supply of submersible pumping set of KSB /Kirloskar/Sabar/ Johnston/ Crompton/ Kirloskar make conforming to BIS: 5659-1970 or latest suitable for lifting Raw Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thurist bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
Total Head =31.00 mtr.
Discharge required from each pum = 15.51LPS
No. of pump required = 2.00 Nos . One as act stand bye
Location of the site of inatallation of machinery = the site is located at a distance of 5.00 kmts from Ranital Railway station by road & 0.75 KM on head load ( for the installation of both machineries.
The Altitude of installation. The altitude of place is 452 mtrs above MSL,Type of current. AC Three phase supply with, Rate Voltage Voltage 415+ Type of water and its source Raw water from Baner Khad, Charactristics of water. Ambient Temperature dig.c 20 dig. C,b)Turbidity NTU =10000 NTU, c)Hardness 260Mg/Ltrs(as CaCO3) = -,d) PH = 6 to 8 , e) , total solid Mg /Ltrs = 3mm to 5mm-,f)Other = -,Depth of intake structrure = 15 mtr ,Static head in Mrs = 27.20mtrs.,Length of R/Main = 60 mtr.,Dia of Rising main = 150MM dia No of working hours per day = 8.00 Hours,Limit of pump operation. = (-) 15 % (+) 10% of total head,R.P.M. of pumping set.= 2900 RPM ( or to be specified by the tenderer)Test run.= 8 Hours continueously for 7 days
Providing and fixing of double flanged cast iron Sluice valve heavy size one dia higher than pump size to delivery Pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS latest with upto date ammendments having seat pressure 16.32 Kg/ cm2 complete in all respect. Within all leads and lifts.
Supply of Kirloskar/Kilburn/ Leader make cast iron class double flanged (swing check type) reflux valve having by pass arrangment class PN 1.6 conforming to relevants BIS 1868-API -600 latest edition) to be provided on delevery side ) of size one step heigher than the delevery size of pump and should be suitable for with standing nominal seat pressure 16.32 Kg/cm2.
Providing and laying PVC insulated jointless flat water proof copper cable of Siemens/Finolex/Grandlay/ Gloster make conforming to BIS-1554 (Part-I)-1988 or (latest with upto date ammendments) of suitable size for the pump sets offered (One cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipe, solder, nut & bolts cable glands etc. laid in pipes or trenches under floor, The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authority, it shall have to be replaced by the tenderer free of cost. On supply side of 3 ½ core coper cable 4.00mm2 (From HPSEB meter to Switch & starter).
On motor side 3 core flat joint less copper cable of size 2.5mm2 (From switch & Starter to motor ) pump installed in the P/Well.
Providing and laying column aseembly of GI/ MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevant BIS code & capable of with standing the feiled test pressure equal to 1.5 times the operating pressure including all type of fitting such as bends, tapers/ reducers, flanges, rubber, gaskets 3mm thick nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge. The pipe material shall confirm to relevant BIS code and capable of withstanding FTP equal to 1.50 times the operating pressure the complete arrangement shall be compromise of. Suction pipe :- To be specified by the tenderer.
Delivery pipe. :- To be specified by the tenderer.
Common header pipe To be specified by the tenderer.
Erection of all equipment of pumping machinery including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Supply, Installation testing & commissioning of star delta starter pannel for submersible pump made out of 16 guage sheet, powder coated dust & vermin proof wall/ base mounted and front opening door type with copper insulated wiring suitable to operate 1 No of rating 2x15 HP through star delta starter mechanism, starter should be capable enough to handle the following fault like short circuit over current, under current over voltage dry run protection and phase loss with Led On/Off & Trip indicator make Armation Electic/ L&T/Schinieder.
Star, Delta and main power contacters of required rating as per type-2 Co-ordination for 15 HP starter.
Voltage protection device to protect panel from over voltage and under voltage.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Muti-function meter indicating different parameters like current, voltage, KWH, PF-THD etc.with RS 485 communication make Aarmation/L&T/Schneider/Seimens.
Main incomer MCB/MCCB suitable capacity of L&T/Schneider/ABB make on the feeder for pumping set confirming to BIS 2516-1985 (Latest edition).
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, control and power wiring, power capacitor, Cooling fan 230 VAC, Control terminal, Bus bar, i.e. bolt insulator, etc.
Surge Suppressor device with Isolating MCCB to eliminate the power surges due to ligtening and system surges.
Control Transformer to provide a stable control voltage to safeguard the control circuit of all the components from the voltage surges and spikes.
Supply, Installation testing & commissioning of tomer based automation for submersible pump make Armation Electric/ L&T/Schinieder.
Installation of global system for mobile communication based module to give On & Off command to enable switch on switch off starter make Armation Electric/ L&T/Schinieder.
Installation of Mobile application (Android/IOS) to give On & Off command to enable switch on switch off command to starter through a mobile app and also it should give message about the On and OFF status of stater make Armation Electic/ L&T/Schinieder.
LWSS Paisa (Submersible Pump set for Booster Stage) i/c Automation Supply of submersible pumping set of KSB /Kirloskar/Sabar/ Johnston/ Crompton/ Kalama make conforming to BIS: 5659-1970 or latest suitable for lifting Raw Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitavle for operation on data given below:-SITE CONDITIONS:-
Total Head =99.28 mtr.
Discharge required from each pump = 16.62LPS
No. of pump required = 2.00 Nos . One as act stand bye
Location of the site of inatallation of machinery = the site is located at a distance of 20.00 kmts from Ranital Railway station by road & 2.00KM on head load ( for the installation of both machineries.
The Altitude of installation. The altitude of place is 452mtrs above MSL,Type of current. AC Three phase supply with, Rate Voltage Voltage 415+ 10% Type of water and its source Raw water from Naker Khad, Charactristics of water. Ambient Temperature dig.c 20 dig. C,b)Turbidity NTU =10000 NTU, c)Hardness 260Mg/Ltrs(as CaCO3) = -,d) PH = 6.5-8.5 , e) ,other static head in mtrs 90.50 mtrs , lenth of R/main170.00mtrs .,Dia of Rising main = 150MM dia No of working hours per day = 8.00 Hours,Limit of pump operation. = (-) 15 % (+) 10% of total head,R.P.M. of pumping set.= 2900 RPM ( or to be specified by the tenderer)Test run.= 8 Hours continueously for 7 days
Providing and fixing of double flanged cast iron Sluice valve heavy size one dia higher than pump size to delivery Pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS latest with upto date ammendments having seat pressure 16.32 Kg/ cm2 complete in all respect. Within all leads and lifts.
Supply of Kirloskar/Kilburn/ Leader make cast iron class double flanged (swing check type) reflux valve having by pass arrangment class PN 1.6 conforming to relevants BIS 1868-API -600 latest edition) to be provided on delevery side ) of size one step heigher than the delevery size of pump and should be suitable for with standing nominal seat pressure 16.32 Kg/cm2.
Providing and laying PVC insulated jointless flat water proof copper cable of Siemens/Finolex/Grandlay/ Gloster make conforming to BIS-1554 (Part-I)-1988 or (latest with upto date ammendments) of suitable size for the pump sets offered (One cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipe, solder, nut & bolts cable glands etc. laid in pipes or trenches under floor, The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authority, it shall have to be replaced by the tenderer free of cost. On supply side of 3 ½ core coper cable 4.00mm2 (From HPSEB meter to Switch & starter).
On motor side 3 core flat joint less copper cable of size 2.5mm2 (From switch & Starter to motor ) pump installed in the P/Well.
Providing and laying column aseembly of GI/ MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevant BIS code & capable of with standing the feiled test pressure equal to 1.5 times the operating pressure including all type of fitting such as bends, tapers/ reducers, flanges, rubber, gaskets 3mm thick nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge. The pipe material shall confirm to relevant BIS code and capable of withstanding FTP equal to 1.50 times the operating pressure the complete arrangement shall be compromise of. Suction pipe :- To be specified by the tenderer.
Delivery pipe. :- To be specified by the tenderer.
Common header pipe To be specified by the tenderer.
Erection of all equipment of pumping machinery including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Supply, Installation testing & commissioning of star delta starter pannel for submersible pump made out of 16 guage sheet, powder coated dust & vermin proof wall/ base mounted and front opening door type with copper insulated wiring suitable to operate 1 No of rating 2x15 HP through star delta starter mechanism, starter should be capable enough to handle the following fault like short circuit over current, under current over voltage dry run protection and phase loss with Led On/Off & Trip indicator make Armation Electic/ L&T/Schinieder.
Star, Delta and main power contacters of required rating as per type-2 Co-ordination for 20 HP starter.
Voltage protection device to protect panel from over voltage and under voltage.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Muti-function meter indicating different parameters like current, voltage, KWH, PF-THD etc.with RS 485 communication make Aarmation/L&T/Schneider/Seimens.
Main incomer MCB/MCCB suitable capacity of L&T/Schneider/ABB make on the feeder for pumping set confirming to BIS 2516-1985 (Latest edition).
LEDThree phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452(Part-I & II) latest with upto date ammendments.
Surge Suppressor device with Isolating MCCB to eliminate the power surges due to ligtening and system surges.
Control Transformer to provide a stable control voltage to safeguard the control circuit of all the components from the voltage surges and spikes.
Supply, Installation testing & commissioning of tomer based automation for submersible pump make Armation Electric/ L&T/Schinieder.
Installation of global system for mobile communication based module to give On & Off command to enable switch on switch off starter make Armation Electric/ L&T/Schinieder.
Installation of Mobile application (Android/IOS) to give On & Off command to enable switch on switch off command to starter through a mobile app and also it should give message about the On and OFF status of stater make Armation Electic/ L&T/Schinieder.
LWSS RAJIANA TRIPAL (Centrifugal Pump Set for Booster stage) i/c Automation.Supply of horizontal spindle horizontal radial split casing/and suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of KSB/Mathur & Platt/Jyoti/ Kirloskar/BE/Maxflow/Beaconweir Sabar make conforming to BIS 5659-1970) pump ( Latest with up to to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting Raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling sliperring squirrel cage screen protected drip proof electric induction motor/ motor of standard make such as Kirloskar/ NGEF/Cromption/Siemen/Jyoti/BHEL/GEC/ABB conforming to BIS 325-1978) read with BIS 900-1972( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts,m painting etc. and shall be and suitable for operation on the date given below: SITE CONDITIONS:-
Total Head =87.24 mtr.
Discharge required from each pum = 15.51LPS
No. of pump required = 2.00 Nos . One as act stand bye
Length of R/main 1125 mtrs
Dia of R/main =150mm dia GMSERW pipe
Location of the site of inatallation of machinery = the site is located at a distance of 20.00 kmts from Ranital Railway station by road & 2.00 KM on head load ( for the installation of both machineries.
The Altitude of installation. The altitude of place is 450mtrs above MSL,Type of current. AC Three phase supply with, Rate Voltage Voltage 415+ Type of water and its source Raw water from Baner Khad, Charactristics of water. Raw water from Baner Khad, Ambient Temperature dig.c 20 dig. C,b)Turbidity NTU =100 NTU, c)Hardness 260Mg/Ltrs(as CaCO3) = -,d) PH =7.5, e) ,Total solid Mg/Lts) PH valve- No of working hours per day = 8.00 Hours,Limit of pump operation. = (-) 15 % ,R.P.M. of pumping set.= 2900 RPM ( or to be specified by the tenderer)Test run.= 8 Hours continueously for 7 days
Providing and fixing of double flanged cast iron Sluice valve heavy size one dia higher than pump size to delivery Pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS latest with upto date ammendments having seat pressure 16.32 Kg/ cm2 complete in all respect. Within all leads and lifts.
Supply of Kirloskar/Kilburn/ Leader make cast iron class double flanged (swing check type) reflux valve having by pass arrangment class PN 1.6 conforming to relevants BIS 1868-API -600 latest edition) to be provided on delevery side ) of size one step heigher than the delevery size of pump and should be suitable for with standing nominal seat pressure 16.32 Kg/cm2.
Providing and laying PVC insulated jointless flat water proof copper cable of Siemens/Finolex/Grandlay/ Gloster make conforming to BIS-1554 (Part-I)-1988 or (latest with upto date ammendments) of suitable size for the pump sets offered (One cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipe, solder, nut & bolts cable glands etc. laid in pipes or trenches under floor, The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authority, it shall have to be replaced by the tenderer free of cost. On supply side of 3 ½ core coper cable 16.00mm2 (From HPSEB meter to Switch & starter).
On motor side 3 core flat joint less copper cable of size 10.00mm2 (From switch & Starter to motor ) pump installed in the P/Well.
Providing and laying column aseembly of GI/ MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevant BIS code & capable of with standing the feiled test pressure equal to 1.5 times the operating pressure including all type of fitting such as bends, tapers/ reducers, flanges, rubber, gaskets 3mm thick nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge. The pipe material shall confirm to relevant BIS code and capable of withstanding FTP equal to 1.50 times the operating pressure the complete arrangement shall be compromise of. Suction pipe :- To be specified by the tenderer.
Delivery pipe. :- To be specified by the tenderer.
Common header pipe To be specified by the tenderer.
Providing and fixing double loop earthing with copper plate 600x600x3mm thick electrode and copper strip 25x3 complete including providing of material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and 20x3mm copper strips of required capacity conforming to BIS: 8034-1978 latest with upto date amendments for above motors and other electrical equipment’s.( For both machineries)
Erection of all equipment of pumping machinery including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Supply Installation ,Testing & Comissioning of energy saving variable frequency starter pannel for centrifugal pump made out of 16 guage sheet powder coated dust & vermin proof Wall/Base mounted and front opening door type with copper insulated wiring suitable to operate 2 No Pumps (1working & 1 standbye) each of rating .... HP .Started should be cpable enable to handle the following faults Like short circuit, over current, ,under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicator Power quality Monitoring & controlling relay at the incomer feeder should be fitted with surge supressor device suitable to prptect against Class 1 & 2 like moisture etc. Make :- ArmtionElectricalPvt. Ltd./MAS/ELLES/Adlec
Energy saving Variable frequency drive starter of 40 HP Heavy duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be capable to control the frequency of pump through out the operation and also should be capanle to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/Bechoff/Bosch/Rockwell
Multi function meter indicating different parameters like current, voltage, KWH, PF, THD etc with Rs. 485 communication make L&T/Conserve/Schneider/Aarmation
Main incomer MCB/MCCB suitable capacity of L&T/Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 (Latest edition) with neutral linked under voltage release
LEDThree phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452(Part-I & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring, Power capacitor, Cooling fan 230 VAC, Control terminal, Bus bar, i.e. Bolt, insulator, etc.
PLC (Programmable Logic Controller) with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel and also will get data from function meter for current, voltage, KWH, PF and THD Make Aarmation Electric/Bechoff Automation/Rockwell Automation /Mitsubishi/ L&T complete in all respects to make the components functional upto date amendments & complete satisfaction of Engineer-in-Charge.
Electronic Relay card 8 Channel for PLC system
SMPS 4.5 Amp to energise PLC system
HMI (human Machine Interferance ) 7'' display for monotoring & controlling of centrifugal pumps Make :- Armation Electrical/Bechoff Automation/Rockwell.
Control MCB for Automation System
Level Sensor to indicate the water level of tank remotely
Shielded data cable for communication of level sonsor with PLC
Installation, Commissioning and Software Development
LWSS RAJIANA TRIPAL (Centrifugal Pump set for Stage-Ist ) i/c Automation Supply of horizontal spindle horizontal radial split casing/and suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of KSB/Mathur & Platt/Jyoti/ Kirloskar/BE/Maxflow/Beaconweir Sabar make conforming to BIS 1520-1980) pump ( Latest with up to to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling sliperring squirrel cage screen protected drip proof electric induction motor/ motor of standard make such as Kirloskar/ NGEF/Cromption/Siemen/Jyoti/BHEL/GEC/ABB conforming to BIS 325-1978) read with BIS 900-1972( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts,m painting etc. and shall be and suitable for operation on the date given below: SITE CONDITIONS:-
Total Head =117.87 mtr.
Discharge required from each pum = 15.51 LPS Each set
No. of pump required = 2.00 Nos . One as act stand bye
Length of R/main 405 mtrs
Dia of R/main =150mm dia GMSERW pipe
Location of the site of inatallation of machinery = the site is located at a distance of 20.00 kmts from Ranital railway station by road & 2.00 KM on head load ( for the installation of both machineries.
The Altitude of installation. The altitude of place is 450 mtrs above MSL,Type of current. AC Three phase supply with, Rate Voltage Voltage 415+ ,Type of water and its clear water from WTP, Charactristics of water Clear water from WTP. Ambient Temperature dig.c 20 dig. C,b)Turbidity NTU =100 NTU, c)Hardness 260Mg/Ltrs) PH valve = 7.5 , e) , total solid Mg /Ltrs PH value= -,Static head in Mrs = -.,No of working hours per day = 8.00 Hours,Limit of pump In the complete of range of (-) 15 % of ,R.P.M. of pumping set.= 2900 RPM ( or to be specified by the tenderer)Test run.= 8 Hours continueously for 7 days
Providing and fixing of double flanged cast iron Sluice valve heavy size one dia higher than pump size to delivery Pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS latest with upto date ammendments having seat pressure 16.32 Kg/ cm2 complete in all respect. Within all leads and lifts.
Supply of Kirloskar/Kilburn/ Leader make cast iron class double flanged (swing check type) reflux valve having by pass arrangment class PN 1.6 conforming to relevants BIS 1868-API -600 latest edition) to be provided on delevery side ) of size one step heigher than the delevery size of pump and should be suitable for with standing nominal seat pressure 16.32 Kg/cm2.
Providing and laying PVC insulated jointless flat water proof copper cable of Siemens/Finolex/Grandlay/ Gloster make conforming to BIS-1554 (Part-I)-1988 or (latest with upto date ammendments) of suitable size for the pump sets offered (One cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipe, solder, nut & bolts cable glands etc. laid in pipes or trenches under floor, The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authority, it shall have to be replaced by the tenderer free of cost. On supply side of 3 ½ core coper cable 16.00mm2 (From HPSEB meter to Switch & starter).
On motor side 3 core flat joint less copper cable of size 10.00mm2 (From switch & Starter to motor ) pump installed in the P/Well.
Providing and laying column aseembly of GI/ MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevant BIS code & capable of with standing the feiled test pressure equal to 1.5 times the operating pressure including all type of fitting such as bends, tapers/ reducers, flanges, rubber, gaskets 3mm thick nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge. The pipe material shall confirm to relevant BIS code and capable of withstanding FTP equal to 1.50 times the operating pressure the complete arrangement shall be compromise of. Suction pipe :- To be specified by the tenderer.
Delivery pipe. :- To be specified by the tenderer.
Common header pipe To be specified by the tenderer.
Providing and fixing double loop earthing with copper plate 600x600x3mm thick electrode and copper strip 25x3 complete including providing of material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and 20x3mm copper strips of required capacity conforming to BIS: 8034-1978 latest with upto date amendments for above motors and other electrical equipment’s.( For both machineries)
Erection of all equipment of pumping machinery including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Supply Installation ,Testing & Comissioning of energy saving variable frequency starter pannel for centrifugal pump made out of 16 guage sheet powder coated dust & vermin proof Wall/Base mounted and front opening door type with copper insulated wiring suitable to operate 2 No Pumps (1working & 1 standbye) each of rating .... HP .Started should be cpable enable to handle the following faults Like short circuit, over current, ,under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicator Power quality Monitoring & controlling relay at the incomer feeder should be fitted with surge supressor device suitable to prptect against Class 1 & 2 like moisture etc. Make :- ArmtionElectricalPvt. Ltd./MAS/ELLES/Adlec
Energy saving Variable frequency drive starter of 60 HP Heavy duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be capable to control the frequency of pump through out the operation and also should be capanle to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/Bechoff/Bosch/Rockwell
Multi function meter indicating different parameters like current, voltage, KWH, PF, THD etc with Rs. 485 communication make L&T/Conserve/Schneider/Aarmation
Main incomer MCB/MCCB suitable capacity of L&T/Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 (Latest edition) with neutral linked under voltage release
LEDThree phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452(Part-I & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring, Power capacitor, Cooling fan 230 VAC, Control terminal, Bus bar, i.e. Bolt, insulator, etc.
PLC (Programmable Logic Controller) with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel and also will get data from function meter for current, voltage, KWH, PF and THD Make Aarmation Electric/Bechoff Automation/Rockwell Automation /Mitsubishi/ L&T complete in all respects to make the components functional upto date amendments & complete satisfaction of Engineer-in-Charge.
Electronic Relay card 8 Channel for PLC system
SMPS 4.5 Amp to energise PLC system
HMI (human Machine Interferance ) 7'' display for monotoring & controlling of centrifugal pumps Make :- Armation Electrical/Bechoff Automation/Rockwell.
Control MCB for Automation System
Level Sensor to indicate the water level of tank remotely
Shielded data cable for communication of level sonsor with PLC
Installation, Commissioning and Software Development
LWSS RAJIANA TRIPAL (Centrifugal Pump set for Stage-2nd ) i/c Automation Supply of horizontal spindle horizontal radial split casing/and suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of KSB/Mathur & Platt/Jyoti/ Kirloskar/BE/Maxflow/Beaconweir Sabar make conforming to BIS 1520-1980) pump ( Latest with up to to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling sliperring squirrel cage screen protected drip proof electric induction motor/ motor of standard make such as Kirloskar/ NGEF/Cromption/Siemen/Jyoti/BHEL/GEC/ABB conforming to BIS 325-1978) read with BIS 900-1972( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts,m painting etc. and shall be and suitable for operation on the date given below: SITE CONDITIONS:-
Total Head=112.62 Mtrs. Discharge required = 1.81 LPS of each Set No. of pump required 2.00 set ( one will act as stand by) , Length of R/main 1040 mters, Dia of R/main =65,, dia GMSERW pipe, Location of the site of installation = the site is located as a distance of 5 Km from Ranital Railway station by road and 0.75 KM on head load ( for the installation of both machineries) The altitude of = The altitude of palce is 450 mtrs above MSL Type of current AC three phase supply with Rate voltage 415+10% , Type of water and its Clear water from Baner Khad ,Charactristics of water. Ambient Temperature dig.c = 20 degree c. b)Turbidity NTU=10 NTU c) Hardness 260 Mg/Ltrs, d) PH value 7.5,e, Total solid Mg/ltrs PH value-, Static head in mtrs=97.80 mtrs, No of working hours=8 hours, Limit of pump- In the complete rane of (-) 15%, R.M.P. of pumping= 2900RPM( or to be specified by the tendere)test Run= 8 Hours continueously for 7 days
Providing and fixing of double flanged cast iron Sluice valve heavy size one dia higher than pump size to delivery Pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS latest with upto date ammendments having seat pressure 16.32 Kg/ cm2 complete in all respect. Within all leads and lifts.
Supply of Kirloskar/Kilburn/ Leader make cast iron class double flanged (swing check type) reflux valve having by pass arrangment class PN 1.6 conforming to relevants BIS 1868-API -600 latest edition) to be provided on delevery side ) of size one step heigher than the delevery size of pump and should be suitable for with standing nominal seat pressure 16.32 Kg/cm2.
Providing and laying PVC insulated jointless flat water proof copper cable of Siemens/Finolex/Grandlay/ Gloster make conforming to BIS-1554 (Part-I)-1988 or (latest with upto date ammendments) of suitable size for the pump sets offered (One cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipe, solder, nut & bolts cable glands etc. laid in pipes or trenches under floor, The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authority, it shall have to be replaced by the tenderer free of cost. On supply side of 3 ½ core coper cable 16.00mm2 (From HPSEB meter to Switch & starter).
Onmotor side 3 core flat joint less copper cable of size 10.00mm2 (From switch & Starter to motor ) pump installed in the P/Well.
Providing and laying column aseembly of GI/ MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevant BIS code & capable of with standing the feiled test pressure equal to 1.5 times the operating pressure including all type of fitting such as bends, tapers/ reducers, flanges, rubber, gaskets 3mm thick nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge. The pipe material shall confirm to relevant BIS code and capable of withstanding FTP equal to 1.50 times the operating pressure the complete arrangement shall be compromise of. Suction pipe :- To be specified by the tenderer.
Delivery pipe. :- To be specified by the tenderer.
Common header pipe To be specified by the tenderer.
Providing and fixing double loop earthing with copper plate 600x600x3mm thick electrode and copper strip 25x3 complete including providing of material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and 20x3mm copper strips of required capacity conforming to BIS: 8034-1978 latest with upto date amendments for above motors and other electrical equipment’s.( For both machineries)
Erection of all equipment of pumping machinery including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Supply Installation ,Testing & Comissioning of energy saving variable frequency starter pannel for centrifugal pump made out of 16 guage sheet powder coated dust & vermin proof Wall/Base mounted and front opening door type with copper insulated wiring suitable to operate 2 No Pumps (1working & 1 standbye) each of rating .... HP .Started should be cpable enable to handle the following faults Like short circuit, over current, ,under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicator Power quality Monitoring & controlling relay at the incomer feeder should be fitted with surge supressor device suitable to prptect against Class 1 & 2 like moisture etc. Make :- ArmtionElectricalPvt. Ltd./MAS/ELLES/Adlec
Energy saving Variable frequency drive starter of 10 HP Heavy duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be capable to control the frequency of pump through out the operation and also should be capanle to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/Bechoff/Bosch/Rockwell
Multi function meter indicating different parameters like current, voltage, KWH, PF, THD etc with Rs. 485 communication make L&T/Conserve/Schneider/Aarmation
Main incomer MCB/MCCB suitable capacity of L&T/Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 (Latest edition) with neutral linked under voltage release
LEDThree phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452(Part-I & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring, Power capacitor, Cooling fan 230 VAC, Control terminal, Bus bar, i.e. Bolt, insulator, etc.
PLC (Programmable Logic Controller) with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel and also will get data from function meter for current, voltage, KWH, PF and THD Make Aarmation Electric/Bechoff Automation/Rockwell Automation /Mitsubishi/ L&T complete in all respects to make the components functional upto date amendments & complete satisfaction of Engineer-in-Charge.
Electronic Relay card 8 Channel for PLC system
SMPS 4.5 Amp to energise PLC system
HMI (human Machine Interferance ) 7'' display for monotoring & controlling of centrifugal pumps Make :- Armation Electrical/Bechoff Automation/Rockwell.
Control MCB for Automation System
Level Sensor to indicate the water level of tank remotely
Shielded data cable for communication of level sonsor with PLC
Installation, Commissioning and Software Development
LWSS Paisa (Centrifugal Pump Set for Stage- Ist) i/c Automation. Supply of horizontal spindle horizontal radial split casing/and suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of KSB/Mathur & Platt/Jyoti/ Kirloskar/BE/Maxflow/Beaconweir Sabar make conforming to BIS 1520-1980) pump ( Latest with up to to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling sliperring squirrel cage screen protected drip proof electric induction motor/ motor of standard make such as Kirloskar/ NGEF/Cromption/Siemen/Jyoti/BHEL/GEC/ABB conforming to BIS 325-1978) read with BIS 900-1972( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts,m painting etc. and shall be and suitable for operation on the date given below: SITE CONDITIONS:-
Total Head=166.24 Mtrs. Discharge required =5.46 LPS of each Set No. of pump required 2.00 set ( one will act as stand by) , Length of R/main 1170 mters, Dia of R/main =125,, dia GMSERW pipe, Location of the site of installation = the site is located as a distance of 20 Km from Ranital Railway station by road and 2 KM on head load ( for the installation of both machineries) The altitude of = The altitude of palce is 450 mtrs above MSL Type of current AC three phase supply with Rate voltage 415+, Type of water and its Clear water d ,Charactristics of water. Ambient Temperature dig.c = 20 degree c. b)Turbidity NTU=100 NTU c) Hardness 260 Mg/Ltrs, d) PH value 7.5,e, Total solid Mg/ltrs PH value-, Static head in mtrs=-, No of working hours=8 hours, Limit of pump- In the complete rane of (-) 15%, R.M.P. of pumping= 2900RPM( or to be specified by the tendere)test Run= 8 Hours continueously for 7 days
Providing and fixing of double flanged cast iron Sluice valve heavy size one dia higher than pump size to delivery Pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS latest with upto date ammendments having seat pressure 16.32 Kg/ cm2 complete in all respect. Within all leads and lifts.
Supply of Kirloskar/Kilburn/ Leader make cast iron class double flanged (swing check type) reflux valve having by pass arrangment class PN 1.6 conforming to relevants BIS 1868-API -600 latest edition) to be provided on delevery side ) of size one step heigher than the delevery size of pump and should be suitable for with standing nominal seat pressure 16.32 Kg/cm2.
Providing and laying PVC insulated jointless flat water proof copper cable of Siemens/Finolex/Grandlay/ Gloster make conforming to BIS-1554 (Part-I)-1988 or (latest with upto date ammendments) of suitable size for the pump sets offered (One cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipe, solder, nut & bolts cable glands etc. laid in pipes or trenches under floor, The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authority, it shall have to be replaced by the tenderer free of cost. On supply side of 3 ½ core coper cable 16mm2 (From HPSEB meter to Switch & starter).
On motor side 3 core flat joint less copper cable of size 12mm2 (From switch & Starter to motor ) pump installed in the bore.
Providing and laying column aseembly of GI/ MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set. The pipe shall conform to relevant BIS code & capable of with standing the feiled test pressure equal to 1.5 times the operating pressure including all type of fitting such as bends, tapers/ reducers, flanges, rubber, gaskets 3mm thick nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer in charge. The pipe material shall confirm to relevant BIS code and capable of withstanding FTP equal to 1.50 times the operating pressure the complete arrangement shall be compromise of. Suction pipe :- To be specified by the tenderer.
Delivery pipe. :- To be specified by the tenderer.
Common header pipe To be specified by the tenderer.
Providing and fixing double loop earthing with copper plate 600x600x3mm thick electrode and copper strip 25x3 complete including providing of material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and 20x3mm copper strips of required capacity conforming to BIS: 8034-1978 latest with upto date amendments for above motors and other electrical equipment’s.( For both machineries)
Erection of all equipment of pumping machinery including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
Supply Installation ,Testing & Comissioning of energy saving variable frequency starter pannel for centrifugal pump made out of 16 guage sheet powder coated dust & vermin proof Wall/Base mounted and front opening door type with copper insulated wiring suitable to operate 2 No Pumps (1working & 1 standbye) each of rating .... HP .Started should be cpable enable to handle the following faults Like short circuit, over current, ,under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicator Power quality Monitoring & controlling relay at the incomer feeder should be fitted with surge supressor device suitable to prptect against Class 1 & 2 like moisture etc. Make :- ArmtionElectricalPvt. Ltd./MAS/ELLES/Adlec
Energy saving Variable frequency drive starter of 30 HP Heavy duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be capable to control the frequency of pump through out the operation and also should be capanle to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/Bechoff/Bosch/Rockwell
Multi function meter indicating different parameters like current, voltage, KWH, PF, THD etc with Rs. 485 communication make L&T/Conserve/Schneider/Aarmation
Main incomer MCB/MCCB suitable capacity of L&T/Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 (Latest edition) with neutral linked under voltage release
LEDThree phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452(Part-I & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring, Power capacitor, Cooling fan 230 VAC, Control terminal, Bus bar, i.e. Bolt, insulator, etc.
PLC (Programmable Logic Controller) with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel and also will get data from function meter for current, voltage, KWH, PF and THD Make Aarmation Electric/Bechoff Automation/Rockwell Automation /Mitsubishi/ L&T complete in all respects to make the components functional upto date amendments & complete satisfaction of Engineer-in-Charge.
Electronic Relay card 8 Channel for PLC system
SMPS 4.5 Amp to energise PLC system
HMI (human Machine Interferance ) 7'' display for monotoring & controlling of centrifugal pumps Make :- Armation Electrical/Bechoff Automation/Rockwell.
Control MCB for Automation System
Level Sensor to indicate the water level of tank remotely
Shielded data cable for communication of level sonsor with PLC
Installation, Commissioning and Software Development
SANJAY SAINI
Vijay Kumar C/O Vasudeva Electricals
Bharat Engg and Suppliers
sadeep kumar
Dogra Construction Company Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .