Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 CrAccepted-AOC | ₹30.0 Cr | L1 | Accepted-AOC After deducting sch of credit of Rs 221043.00 |
| 2 | L2₹32.5 CrRejected-Finance | ₹32.5 Cr | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹35.3 CrRejected-Finance D NO 58 21 50 BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | ₹35.3 Cr | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹35.4 CrRejected-Finance | ₹35.4 Cr | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹35.5 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹35.5 Cr | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹33.3 Cr
EMD Value
₹15 L
Closing Date
8 Apr 2025, 6:00 pmClosed
CE NAVY VISAKHAPATNAM
CE NAVY STATION ROAD VISAKHAPATNAM
DEMOLITION AND RECONSTRUCTION OF TECHNICAL BUILDING AT NAD VISAKHAPATNAM UNDER GE (P) NAVY VISAKHAPATNAM
2025_MES_691896_2
85435
Open Tender
Civil Works
730 days
CE NAVY VISAKHAPATNAM
Please refer Tender documents
13 documents required · 13 mandatory
₹3,000
GE P NAVY VISAKHAPATNAM
₹15 L
Yes
29 May 2025
7 Mar 2025
15 Apr 2025
7 Mar 2025
8 Apr 2025
28 Mar 2025
Amount
Schedule "A" Part – I to Schedule "A" Part – XXV: NOTE: Schedule "A" Part – I to Part – XX are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "Buildings/Structures" as listed in Schedule "A" Part – I
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Lumpsum price worked out by the contractor for "SITE CLEARANCE & AREA DEVELOPMENT/ EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "ROADS, PATH, HARD STANDING, CULVERTS", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part –IX
Lumpsum price worked out by the contractor for "FIRE ALARM SYSTEM", as listed in Schedule "A" Part –X
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "AIR CONDITIONING", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "SPECIAL POWER SUPPLY SOCKET", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "PVC CONDUIT", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "COPPER EARTHING", as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "LIGHTNING PROTECTION SYSTEM", as listed in Schedule "A" Part – XVI
Lumpsum price worked out by the contractor for "DG SET", as listed in Schedule "A" Part – XVII
Lumpsum price worked out by the contractor for "WATER COOLER", as listed in Schedule "A" Part – XVIII
Lumpsum price worked out by the contractor for "DEMOLITION", as listed in Schedule "A" Part – XIX
Lumpsum price worked out by the contractor for "PILE FOUNDATION", as listed in Schedule "A" Part – XX
Schedule "A" Part - XXI: (Miscellaneous Items) (Internal Electrification, Internal water supply, External Electrification, Sewage Disposal, Fire alarm system, Fire fighting system, Air conditioning, Special Power supply socket, PVC conduit, EOT Crane, DG Set, Water cooler, Demolition)
Internal Electrification
S&F LED adore lamp for AC 240 Volt supply, B22 type, 9 watts of five star rated complete all as specified and as directed.
S&F Energy efficient LED tube light fitting, 2x20 Watts or nearest size, 240V, 50 Hz surface mounted, LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
S&F LED Security light fitting with tube 30W New generation Energy saving & environmental frindly long lifemade up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc compelte all as specified and as directred.
S&F 70W LED Flameproof wellglass fitting in diecast al housing with heat resistant toughned glass, made of alluminium alloy LMG, CIMFR certified, recommended for gas/vapour group of IIM & IIB and zone 1 & 2 with IP65 protection complete with all accessories prewired and including connecting up with twin core twiated flexible copper conductor cable of suitable size etc all as specified and directed
S&F flameproof TPN distribution board enclouser 415 V, 50 HZ , complete internal wiring and 250 amps bus bar all as specefied and directed with following provisions: Incoming: MCCB 4P 160 A, 25 kA Outgoing: (a) MCB TP 63 A 10 kA C curve-05 Nos (b) MCB SP 63 A 10 kA C curve – 13 Nos (c) MCB SP 25 A 10 kA C curve – 03 Nos
S&F concealed in wall V TPN DB double door type, 4 way 415 V, 50 Hz, IP 43 protection, with provision for MCCB 100 Amps as incomer and outgoing circuits MCB SP/TP, fill empty way with blanking plates complete all as specefied and directed.
Blank
S&F MCCB 4P 100 Amps, 16kA 415 Volts, C curve complete all as specefied and directed.
S&F MCB TP 40 Amps 415 Volts, C curvecomplete all as specefied and directed.
S&F MCB SPN, 6 to 32 Amps 240 Volts , 10KA, C curve complete all as specefied and directed.
S&F MCB SP, 6 to 32 Amps 240 Volts , 10KA, C curve complete all as specefied and directed.
S&F flameproof DB SPN 8 way 240V, 50 Hz, Complete internal wiring and 100 A bus bar all as specified and directed with following provisions Incoming: MCB SPN 40 A 10 kA C curve Outgoing: (a) MCB SP 6 A 10 kA C curve – 03 Nos (b) MCB SP 20 A 10 kA C curve – 03 Nos
S&F flameproof TPN distribution board enclosure 415V, 50Hz , complete internal wiring and 160 A bus bar all as specified and directed with following provisions: Incoming: MCCB 4P 100 A, 16 kA Outgoing: MCB SP 40 A 10 kA C curve-12 Nos
S&F flameproof pedestal type fan 600mm sweep single phase 220 V complete all as specified and directed
S&F flame proof SS hose conduit pipe 20 mm dia, 300mm long complete all as specified and directed
S&F flame proof 4 way junction box 100 mm dia complete all as specified and directed
External Water Supply
Cutting existing steel tubing of 200mm dia for alterations or additions necessarily done in position without taking down, dewatering for inserting flanged sockets, 'Tee' with reducer to 80 mm, etc for tapping all as specified and directed. Note: The rate inclusive of specials, joints etc complete all as specified and directed.
M&L for Masonry valve chamber 750x750x750 mm (internal dimensions) for valve including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type C1 coping 50x50x6 mm angle iron 6 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified
M&L for valve chamber of internal size 1.0x1.0x1.0m (int dimensions) comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm be;ow GL,100mm thick PCC 1:3:6 type B1 as in copings,3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primerincluding necessary earth work and excavation in any type of soil complete all as directed.
External Electrification
S&F Outdoor type compact Ring main unit, extendable on both side consisting one incoming two outgoing SF6 insulated VCB each of nominal Voltage11 kV, 630 Amp having breaking current of 20 kA/3 sec along with metering module, metal enclosed, free standing floor mounted with self powered microprocessor controlled numeric relay overcurrent & earth fault protection, master trip relay, powerpack with 15mins backup incl batteries and related CTs as specified below, cable switch module and interlocking mechanism, SF6 tank having pressure of 1.4 bar at 20 C with manometer, colour coaded copper burbars with cover, with earthing switch, SCADA cpmpatible and necessery PCC foundation complete all as specified as directed.
Supply install, testing commissioning of outdoor type 11 kV Compact Sub Station with non extensible manually operated 1 No SF6 insulated VCB with metering cubicle/relays/protections, HT Cable/Bus bar, 1 No transformer 630 kVA,11kV/433, oil filled & associated LT side having of ACB 1000A 50kA 02 No (one for main LT panel and one spare) complete all as specified and as directed below:
HT Side: 11kV, 630A, 21kA/1 sec, non-extensible breaker in min 2.5mm stainless non ferrite and non magnetic robotically welded steel tank with copper busbar, compact switchgear consisting of one no. Fixed manual Vacuum Circuit Breakers (VCB) with direct incoming connection in SF6 insulated selaed for life gas tank with IP67 degree of protection with integrated current protection which shall be connected to HV side of above transformer using 1C x 3R x 95 Sqmm Cable with site replacable bushings alongwith air insulated metering module for bus side metering. The breaker shall have self powered microprocessor based numerial over current and earth fault relay protection with charged open / closing mechanism, on/off indcators, mechanical operation counters etc. Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm Al. unarmorured XLPE Cable. a) Relay shall be self powered of Ashida/C&S Make. ( 50, 50N, 51, 51N) with RS 485 communication port - 01 No b) Protection CT shall be 40/1A 2.5VA 5P10. (Make: ECS/Ericon/Bharti Electricals) - 01 Set c) Standard Manometer (SF6 Gas Pressure Indicator) - 01 No d) Fault Passage Indicator (FPI) for incoming only - 01 No e) Voltage presence indicator (VPIS) for incoming Healthy Indications - 01 Set f) Manual push button for breaker ON/OFF - 01 Set g) Mechanical Indication for Breaker ON/OFF/Earthed - 03 Nos h) Operating handle - 01 No i) All incoming modules of the breaker shall be capable for cable termination of 3C x 120 sq.mm Aluminium XLPE Cable.
Transformer: 630 kVA 11kV/433V Dyn11 Oil Filled (ONAN) Hermetically sealed distribution transformer with corrugated radiator wall (without conservator type design) & Top mounted normal porcelain bushing for HT, LT with Off circuit tap changer (Make: Danish/ABB /Voltamp/CG/Indian Transformers & Electricals Pvt Ltd a) Off Circuit Tap Changer (OCTC), Tapping range +5% to -5% in a steps of 2.5% (4 Steps/5 Positions) b) Temp. Rise Shall be 40/45 Deg. C for Oil/Winding resp. Over an ambient of 50Deg.C Temp c) Insulation Class: A d) Losses ( Subject to IS 1180 Efficiency Level 2/ Star 2 as per latest Amendment 4) Max. Total Loss @ 50% Loading: 1745 W and Max. Total Loss at 100% Loading: 4850 W. e) % Impedance (%Z) shall be 4.50% (Subject to IS Tol.) f) Rating & Diagram (R&D) Plate (Fitted on Transformer) g) Oil Temp. Indicator (OTI) with alarm and trip contact h) Winding Temp. Indicator (WTI) with alarm and trip contact i) Rated temp Class of Transformer Compartment K10 upto 1000kVA
LT Side: LT PANEL- 1500 A Aluminium Busbar (100% for Phase & 50% for Neutrals) Current density 1amp/sqmm, having IP2X, Fabrication using 1.5/2mm CRCA sheet steel complete with internal wiring consisting of following. a) INCOMER From transformer b) 1000 Amps 4P 50Hz 50 kA Fixed Manual Type Air Circuit Breaker (ACB) with microprocessor based Ekip Dip release for Overload (O/L), Short circuit (S/C) & Earth Fault (E/F) protection. - 02 Nos c) LED type Indicating Lamp - RYB, ON-OFF-TRIP.(Make: TEKNIK/ BINAY/ ESSEN DEINKI) - 01 Set d) LT side metering CT 1000A/ 5A, 5VA, Cl:1.0 (G&M/NEWTEK) - 01 Set e) Digital Multifunction Meter (MFM), CL-1.0 Accuracy with RS485 Port (Make:-CONZERVE/ RISHABH/ ELMEASURE/SECURE) - 01 No i) Rated temp Class of Transformer Compartment K10 upto 1000 kVA
OUTDOOR ENCLOSURE: Outdoor type enclosure having construction of Galvanised Sheet Steel having 1.5mm thickness for Non-load bearing & 2 mm for Load bearing partition sheets & Door with HRCA 4 mm base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated (Colour Light gray and dark gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. As per IEC 62271-202:2022. INTERCONNECTION AND EARTHING: Interconnection Between HT switchgear & Transformer using 1Cx3Rx95 Sq.mm XLPE Single Core Aluminum Unarmored Cable & Interconnection between Transformer & LT switchgear using Aluminum Busbars with aluminum flexible. Internal earthing connections by using 50X6mm GI strips including Transformer Neutral. Note: Compact Sub-Station is outdoor plinth mounted type, Erection, Commissiong and Civil work for package substation and the foundation making is deemed to be included in quoted ratres.
Main LT Panel made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 2000Amp capacity complete with powder coating, necessary internal electric connection as required and provision of the following : (Main LT Panel).
Incoming: Air circuit breaker 1000 Amps, 50 kA, Draw out type, 4 Pole, microprocessor based, short circuit protection, with necessary CTs, meters and cable boxes. - 1 No. Outgoing: (a) Air circuit breaker 800 Amps, 50 kA, Draw out type, 4 Pole, microprocessor based, with necessary CTs, meters and cable boxes. - 2 No (500 kVA DG AMF panel & 01 Spare) b) MCCB 400 Amps, 36 kA, 4 Pole, microprocessor based- 03 No. (250 kVA DG AMF of AC Plant, APFC panel & 01 Spare). c) Intelligent Panel meter to measure Voltage, current, frequency, power factor, kWH, etc with all connected CTs. d) LED indicating lamps with colour Red, Yellow, Blue of 01 Sets.
LT Distribution Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (500 kVA DG Panel)
Incoming: a) Air circuit breaker 800 Amps, 50 kA, Draw out type, 4 Pole, microprocessor based, with necessary CTs, meters and cable boxes. - 1 No. Outgoing: a) MCCB 400 Amps, 36 kA, Pole, microprocessor based- 02 No (For Isolation transformer 300 kVA & 01 Spare). b) MCCB 200 Amps, 25 kA, Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection.- 02 No (For HTL Bldg panel & 01 Spare c) MCCB 100 Amps, 16 kA, Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection.- 03 No (02 Nos VTPN at Adm block & 01 Spare). d) LT 440 Volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 40 Amp rated complete with overload protection, no-Volt thermal based release.- 02 Nos. (for street light timer, and spare) e) LT 230 Volts 1 phase, 2 wire 50 cycles, 10 kA, MCB DP of 63 Amp rated complete - 03 Nos. (electrical room, paint room and spare) f) Intelligent Panel meter to measure Voltage, current, frequency, power factor, etc with all connected CTs f) LED indicating lamps with colour Red, Yellow, Blue - 01 Sets
LT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 400 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (HTL Bldg panel)
Incoming: a) MCCB 200 Amps, 25 kA, Pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection.- 01 No. Outgoing: a) MCCB 400 Amps, 36 kA, Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection.- 02 No (For Isolation transformer 300 kVA & 01 Spare). b) LT 440 Volts 3 phase, 4 wire 50 cycles, 16 kA, MCCB of 63 Amp rated complete with overload protection, no-Volt thermal based release.- 02 Nos. (For HTL Bldg V TPN and 01 spare) c) Intelligent Panel meter to measure Voltage, current, frequency, power factor, kWH, etc with all connected CTs d) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
S&F Loop in loop out box 155x210x92 mm of FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knockouts for cable entry and exit, of IP 66/ IP 67 for cable entry for cable exit with MCB 6 Amps, 10 kA, C Curve with terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands, etc all as specified.
M&L for PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694, 1.5 sqmm 3 core drawn through PVC pipe with clamping materials complete all as specified
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mPa working pressure.
S&F street light panel 415 V, three phase 6kW with digital 24 Hrs timer switch along with 32A TP contactor and 40A TP MCB fitting inside steel encloser including necessery arrangements for mounting on pole/wall or as directed.
SEWAGE DISPOSAL
M&L for SRFC factory made manhole cover with frame square, rectangular, circular of area not exc 2.1 sqm (heavy duty) complete as directed.
M&L for 100 Users RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 m and overall depth of 3 m all as specified and directed.
M&L for Soakage well of size 1.20 m dia x 3.00 m effective depth with excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size all as specified and directed.
M&L for 10 Users RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 m and overall depth of 2.38 m all as specified and directed.
M&L for Soakage Well of size 1.20 m Dia x 2 m effective depth with excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size all as specified and directed
FIRE ALARM SYSTEM
S&F 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directed.
FIRE FIGHTING SYSTEM
Supplying and lay ductile pipe with double flanged centrifugally cast(spun) class K-9 of 200 mm dia pipe conforming to IS-8329 including provision of gaskets, nuts/bolts and specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning.
Supplying and lay ductile pipe with double flanged centrifugally cast (spun) class K-9 of 150 mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows, bends reducers, taper pieces, including testing and commissioning.
M&L for valve chamber of internal size 1.0x1.0x1.0m comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm below GL,100mm thick PCC 1:3:6 type B1 as in copings, 3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primerincluding necessary earth work and excavation in any type of soil complete all as directed
Supply and install MS rectangular fire bucket stand with shed for four Nos fire buckets duly painted in red colour all as specified and directed.
AIR CONDITIONING WORKS INCLUDING DESIGN, SUPPLY, INSTALLATION, TESTING & COMMISSIONING (INCLUDING PHASE – I & PHASE – II PERFORMANCE TESTS):
Design, Supply, install, test and commissioning of scroll type Chiller Central Air Conditioning plant, water cooled with single/multi compressor, comprising of Hermetically sealed Compressors, Flooded type Evaporator, Shell and tube Condenser, suitable expansion device, suitable for operation on and nominal capacity of minimum 3x60 TR (2 Nos working at a time & 1 No Standby) comprising of the following : Note : AC shall be covered for the following Rooms : Room Q, R, S, T, U, V and Front Verandah.
(A) CHILLER PACKAGE UNIT:- Micro processor controlled scroll chiller unit complete, factory assembled, factory tested, of minimum 60 TR x 3 Nos (one number as standby), minimum 120 TR nominal cooling capacity working on latest eco friendly (with no greenhouse effect) refrigerant (Green gas) comprising of scroll compressors operated with green gas suitable for 415V, 50 Hz, 3 phase, piping controls & accessories, starter & microprocessor control panel, refrigerant, oil charged mounted on common base frame with anti vibration pads complete as per manufacturer's specifications as recommended by OEM: 03 Nos (Two Nos working at a time and one stand by).
(i) Efficiency of scroll type chiller package shall comply with latest ECBC norms. (ii) The contractor shall submit catalogue indicating model No of unit offered and test certificate indicating power consumption at 25%, 50% 75% and 100% load for approval of GE before placing the final order. Power consumption at part load shall also be as per ECBC norms. (iii) The scroll type chillers shall be accepted by GE based on test certificates. RCC foundation as per manufacturers standards shall be deemed to be included in the rate quoted.
(iii) HDPE/PVC make up water tank of adequate capacity but not less than 5000 liters (02 Nos) installed on PCC/brick staging up to height as per manufacturer specifications for make up water requirement including brass float valve with polyethylene ball, over flow and drain arrangement, incoming connection of suitable bore GI pipe medium grade from tank to tapping point including necessary cutting of existing pipe line and tapping of branch connections with GI pipe of suitable bore medium grade all as directed (The item rate is inclusive of provisioning all connected inlet pipe lines from existing sources and all outlet pipes - 01 Job (iv) Energy efficient mono block type 3 phase electric driven pump sets of adequate capacity working on 415V AC for re-circulation of condenser water of 50% plant capacity-03 Nos (02 Nos working and 1 No standby) & FASD starter for re-circulation of condenser water with ribbed rubber vibration isolation pads two nos mounted on ISMC frame (painted with anti corrosive primer & paint) on PCC foundation complete all as specified or as recommended by OEM. - 01 Job
(v) Condenser water piping of MS class 'B' medium grade (ISI marked), pipe and fitting of suitable size connected/jointed by electric arc continuous welding including two coats of anti corrosive paint over a coat of primer for interconnecting the cooling tower with condensers and pump, make up water tank, drain pipe, complete with Y strainer, NRV,pressure gauges and butterfly valves- 01 Job. Make of MS pipes will be approved by GE. (vi) Non-chemical type on line scale preventer of required size as per the capacity of the condenser water pumping system including piping and control valve.
(a) Compressors: Semi hermetic scroll compressors with minimum loading capacity 25%, operating voltage 360 - 440 Volts, 50 Hz, 3 Phase AC supply and working with refrigerant R- 410A / R - 407C / R - 134A. (b) Condenser Section : Shell and Tube type condenser internally knurled copper tubes (c) Expansion Valve: Electronic expansion valve should be capable enough to operate on wider temperature range with energy efficient improvement at part load conditions, as per manufacturer's specifications. (d) Evaporator: Flooded type evaporator all as per manufacturer's specifications. (e) Safety Protection: Safety protection on low cooling temperature, low oil pressure, high refrigerant pressure, electric leak, compressor overload, high/low voltage and single phasing shall be provided. Automatic control of refrigerant condition and compressor ON/OFF status and loading sequence system shall be provided.
(f) Refrigerant : HFC - 134A / HFC - 410A / HFC - 407C of zero ozone depletion potential refrigeration circuits of total capacity as per manufacturer's specifications. (g) Control : Micro Processor control with LCD interface capable of monitoring all machine operating parameters like suction / discharge pressure Oil pressure, compressor operating hours, set point, air temperature, entering/ leaving water temperature etc complete and precisely manages the operation of compressors, expansion devices, fans and of the evaporator/ chiller water pump for optimum energy efficiency as per manufacturers specifications.
(C) CHILLED WATER CIRCULATION SYSTEM Comprising of the following:- (i) Inlet and out let connections for Chiller unit - 03 Nos (ii) Energy efficient mono block type 3 phase electric driven pump sets working of adequate capacity on 415V AC for re-circulation of chilled water of 50% plant capacity-03 Nos (02 Nos working and 1 No standby) including 100mm dia Pressure gauge on delivery side of pumps including rubber vibration isolation pads mounted on ISMC frame (painted with anti corrosive primer & paint) on PCC foundation including all connections complete all as specified. - 01 Job
(iii) Chilled water piping with MS Medium Grade ERW pipe of suitable diameter including all wieldable fittings, butterfly valves NRVs & 'Y' strainers for interconnection between water chiller, chilled water pumps with AHUs and cooling coil units. Chilled water piping shall be insulated with 75mm thick EPS pipe section TF quality cladded with Aluminium sheet 26 SWG including water flow switch and electrically operated modulating / Three way mixing valve of required size with actuator & modulating thermostat control for each AHU - 1 No. (iv) PVC / HDPE Expansion tank of capacity not less than 1000 ltrs capacity including insulation with 75mm thick fibre glass/thermo coal/density of 24 kg/cum finished with cement plaster including civil works and painting with 3 coats of cement based paint and GI medium grade piping connections and necessary piping control valves on inlet, outlet and wash out, float valve etc-01 Job.
(D) AIR TREATMENT SYSTEM : Comprising of the following:- (i) Double skin construction air handling unit suitable for chilled water system made out of extruded aluminium structural frame /aluminium corners and intermediate connecting pieces and panels of galvanised steel sheet of appropriate thickness as recommended by OEM on both sides with 25mm thick pressure injected PUF of appropriate density using CFC free blowing agent ,the panels having scratch free plastisol coating on outer side.The fan section should be mounted on anti vibration spring isolators and free from main structure. The fan should be back ward curved centrifugal fan with air discharge up blast, belt driven with TEFC induction motor of suitable capacity. The coil section consist of 6 row deep coil with min 12 fins/inch duly coated. The filter section consist of prefilter with 5 micron 90% efficiency. The other accessories are view port, limit switch, stainless steel (SS3) drain pan, volume control damper with Energy Efficient Motor (EE Series) of suitable capacity and specified makes, AHU shall be provided with UVC emitters & fixtures in sufficient quantity so as to provide equal distribution of UVC energy on the coil and in the drain pan all as specified or as recommended by OEM.
(ii) Strip type Heater bank of suitable capacity in three banks with necessary copper conductor wiring for banking complete - 03 Sets (iii) Pan type humidifier comprising of stainless steel tank and pan necessary heater, wiring, water piping GI pipe medium grade 15mm bore including float valve and brass stop cock in inlet pipe. The make of GI pipe will be approved by GE. (iv) Humidistats and Thermostats are to be provided in AHU room (v) Three way Mixing Valve of required size with motorised actuator and modulating thermostat control for AHU. (vi) Accoustic Insulation with 25mm thick fibre glass rigid boards and finished with RP tissue paper and 28 mm gauge aluminium perforated sheet upto 5 mt from outlet of the air plenum including air plenum for all AHUs all as specified and directed. (vii) Under deck insulation for AHU rooms shall be provided with Fire retardant XPE closed cell of appropriate thickness as recommended by OEM metalised polyester film and self adhesive backings with protection peel off paper. (viii) Fresh air damper with GI bowl/ fittings and mosquito proof netting shall be provided for AHU.
(E) AIR DISTRIBUTION SYSTEM:- Comprising of the following:- (i) Supply and return air ducting made out of commercial grade GI sheet Zinc coating 120 grade, IS : 277 and factory fabricated as per SMACNA - 1995 standards and as per IS-655, required portion of duct shall be acoustically insulated with standard size of AC sheets, insulated with 25 mm thick resin bonded fibre glass wool of density 24 Kg /cum covered with factory laminated aluminium foil fixed with adhesive tape & finally cladded with 26 SWG aluminium sheet & supported by internal channel & clamping, wherever the ducting passes through un-conditioned space shall be insulated with 75 mm thick resin bonded fibre glass wool of density 24 Kg /cum and covered with GI chicken wire mesh and cladded with aluminium foil fixed with adhesive tape and finally cladded with 26 SWG aluminium sheet & supported by internal channel & clamping,wherever the ducting is exposed to sky shall be insulated with 75 mm thick resin bonded fibre glass wool of density 24 Kg /cum covered with polythene sheet faced hessian cloth, GI chicken wire mesh and cladded with sand cement plaster and supported by MS channel & clamps complete in all respect. Make: Sail/ Tata/Jindal
(ii) Aluminium powder coated double deflection adjustable type Supply air grills /diffusers with MS volume control dampers and Aluminium powder coated fixed bar type return air grilles/diffusers without volume control damper, for return air -1 Job. (iii) Fire dampers automatic type UL stamped fusible plug (CPRI Certified) and operated with stainless steel spring made out of 16 SWG GI sheet and limit switch to be provided in each main supply air duct near plenum in AHU room for each AHU and interlocked with AHU motor to cut off circulation of air in case of fire . - 01 Job (F) ELECTRICAL WORK :- Comprising of the followings: (i) Main Electrical Panel Board: Cubical type floor mounted, vermin proof, dust proof, CPRI approved, powder coated switch board panel made out of CRCA sheet not less than 2.0 mm thick Powder coated paint suitable for operation on 415 Volts 50HZ AC supply, internally wired with copper conductor wire, comprising of the following:-
12. Any work not included in the above details but is an in escapable technical requirement for the efficient performance and smooth functioning of the plant shall be clearly specified and included in the technical offer. 13. COP shall not be less than 4.7 14. The design conditions as specified in the tender shall be achieved within maximum 120 minutes time. 15. 3/6 core flat copper conductor of suitable size for compressor motors, cooling tower motor, chiller motor condenser motor and AHU motors etc shall deemed to be included in the unit rate quoted. 16. Minimum one chiller shall be tested at 100 % load on ARI test bed at manufacturer’s premises to verify the actual capacity & power consumption of the chiller machines.
21. The capacity mentioned for AC plant is tentative, actual capacity should be workout by the contractor based on inside and outside cenvironment conditions to attain desired conditions throughout the year. 22. Contractor should submit Design folder duly incorporating complete design, heat load calculations as per ASHRAE standards, layout plans and specifications and make/brand as per zonal specifications of equipment incl BoQ duly bound 3 hard copies and soft copy in 2 Nos CDs duly vetting from IIT/NIT for approval of Accepting Officer before execution.
S&F Voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output Voltage stablized at 230 V with accuraacy of 2.5 % of cap 2 kVA
SPECIAL POWER SUPPLY SOCKETS
Supply, install, commissioning and testing of 300 KVA Isolation transformer Power Supply 415 Volt A/C 50 cycle input and constant Output Voltage with Enclosure Protection IP 55 complete all as specified and directed.
S&F Servo Voltage stabilizer 300 kVA for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output Voltage stabilized at 415 with accuracy ± 2.5% unbalanced loag and Voltage condition and speed of correction 8 Volts per second with MCCB at input and output contactor with bypass switch providing protection in high/low Voltage, overload and short ckt protection complete all as specified and as directed.
M&L for LT Panel board made out of CRCA sheet 2 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 500 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (Isolation transformer panel).
Incoming: MCCB 400 Amps, 36 kA, 4 Pole, suitable for capacitive loads, microprocessor based.- 01 No. Outgoing: a) MCCB 125 Amps, 16 kA, 3 Pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection.- 05 No (Three Nos for HTL Bldg for special power supply, 01 for other rooms & 1 spare). b) Intelligent Panel meter to measure Voltage, current, frequency, power factor, kWH, etc with all connected CTs . c) LED indicating lamps with colour Red, Yellow, Blue - 03 Set.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 62A, 250V, 2P+earth(Battery Charging & trolley storage room).
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 63A, 500V, 4P+earth (12 Nos (6x2Nos) for HTL rooms+ 02 Nos for Silicagel room)
PVC CONDUIT
S&F telephone/communication network sockets(Jack type) RJ 45 with shutter 1 module with cover plate complete complete with all acessories all as directed.
S&F factory fabricated GI metal flush boxes suitable for 1-2 module complete
EOT CRANE (FLAME PROOF)
Supply, Install, Test and Commissioning of Electrically operated flame proof over Head Travelling (EOT) Crane of 2.0 Ton Capacity complete and having of 10 m span (approximate) with long travel distance of 12 m with clear hook hight of 3.0 m from floor level (including 04 Nos flame proof flood light near hook and corner, double box gider type with cecessary steel supporting structure electric moter with micro motion control with VVVF drive and shall be operated by means of push button pendent unit from the floor and control panel and operated with pendent control moveable independent of crab position including provision of steel gantry rails for long travel for complete lengh and provision of down shop Lead (DSL) and shrouded bus bar system complete all as specified. (For HTL hall). a) Hoist Speed 1.0 m/min. b) Hoist Creep 0.5 m/min. c) CT Speed 3.0 m/min. d) CT Creep 1 m/min. e) LT Speed 3.0 m/min. f) LT Creep 1.0 m/min. g) Hook height 3.0 m.
Supply, Install, Test and Commissioning of flame proof Electrically operated over Head Travelling (EOT) Crane of 2.0 Ton Capacity complete and having 7 m span (approximate) with long travel distance of 18.5 m with clear hook hight of 5.0 m from floor level including 4 Nos flame proof flood light near hook and corner, double box gider type with cecessary steel supporting structure electric moter with micro motion control with VVVF drive and shall be operated by means of push button pendent unit from the floor and control panel and operated with pendent control moveable independent of crab position including provision of steel gantry rails for long travel for complete lengh and provision of down shop Lead (DSL) and shrouded bus bar system complete all as specified. (For handling Area). a) Hoist Speed 1.0 m/min. b) Hoist Creep 0.5 m/min. c) C.T Speed 3.0 m/min. d) C.T Creep 1 m/min. e) L.T Speed 3.0 m/min. f) L.T Creep 1.0 m/min. g) Hook height 5.0 m.
Note: for the above crane item the contractor shall check actual dimensions on ground before submitting drawings for approval. Make: Tojym, Anupam, Mukund, Jessop, WMI, Dinesh Enterprises.
DG SET
iv) Regulation performance: The Voltage is kept constant with +/- 1%, manual Voltage adjustment within +/- 5% v) Frequency regulation +/- 1% (B) Diesel Engine: - Adequate capacity of Diesel engine as approved by GE basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under i) Fly wheel with housing. ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable size with MS pipe light grade up to & outside and 1 m away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold, Silencer : Residual type Bellows v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. vi) Lubricating oil System : Lubricating oil filter Lubricating oil pump
vii) Air Intake System :Air intake Manifold Air cleaner dry type viii) Governor :- Electronic Governor ix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator x) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, Lubricating oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel xi) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant Temperature indicator, Battery Volt display. xii) Safety Controls : - Engine low lubricating oil pressure high water Temperature and over speeding of engine. xiii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling. xiv) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xv) Base Frame : - Should be provided as OEM norms
vii) Air Intake System: Air intake Manifold Air cleaner dry type viii) Governor: Electronic Governor ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, Lubricating oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant Temperature indicator, Battery Volt display. xii) Safety Controls: Engine low lubricating oil pressure high water Temperature and over speeding of engine. xiii) Coupling arrangement: Flexible coupling, fly wheel to suit flexible coupling. xiv) Accessories: AVM Pads built in enclosure and for entire unit on platform. xv) Base Frame: Should be provided as OEM norms
C) AMF Panel :- Factory made outdoor type control cubical made out of CRCA sheet 3.15 mm thick dust and vermin proof totally enclosed with front opening of 415 Volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 500 kVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 pole ACB/MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating Voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery Voltage, etc. a) Annunciation with indication lamps for : (i) Low Lubricating oil pressure. (ii) High Water Temperature. (iii) Engine over speed. (iv) Battery low Voltage Controls :- a) Load on Indication b) Load off indication c) Engine start push button
viii) The enclosure should be suitably illuminated by LED Lamp fittings. ix) The noise level should be 75 dba at 1m under free field conditions. x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size as per OEM recommendation foundation drawing for placing of DG Set complete all as specified and directed.
iv) Regulation performance: The Voltage is kept constant with +/- 1%, manual Voltage adjustment within +/- 5% v) Frequency regulation +/- 1% (B) Diesel Engine: - Adequate capacity of Diesel engine as approved by GE basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under i) Fly wheel with housing. ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable size with MS pipe light grade up to & outside and 1mr away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold, Silencer : Residual type Bellows v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. vi) Lubricating oil System : Lubricating oil filter Lubricating oil pump
vii) Air Intake System :Air intake Manifold Air cleaner dry type viii) Governor :- Electronic Governor ix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator x) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, Lubricating oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel xi) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant Temperature indicator, Battery Volt display. xii) Safety Controls : - Engine low lubricating oil pressure high water Temperature and over speeding of engine. xiii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling. xiv) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xv) Base Frame : - Should be provided as OEM norms
C) AMF Panel :- Factory made outdoor type control cubical made out of CRCA sheet 3.15 mm thick dust and vermin proof totally enclosed with front opening of 415 Volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 250 kVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 pole ACB/MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating Voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery Voltage, etc. a) Annunciation with indication lamps for : (i) Low Lubricating oil pressure. (ii) High Water Temperature. (iii) Engine over speed. (iv) Battery low Voltage Controls :- a) Load on Indication b) Load off indication c) Engine start push button
viii) The enclosure should be suitably illuminated by LED Lamp fittings. ix) The noise level should be 75 dba at 1m under free field conditions. x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size as per OEM recommendation for foundation drg for placing of DG Set complete all as specified and directed.
WATER COOLER
S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250 V with output Voltage stabilized at 230 V with accuracy of +_ 2.5% and of capacity 2 KVA complete all as specified and directed.
DEMOLITION
Taking down aluminium point wiring (light, fan, socket, power, calling bell etc) complete including fixture and fittings such as switches, ciling roses, pendents, regulators, sockets, light fittings etc and making good the disturbed surface om walls floors complete all as specified and directed.
Taking down of ceiling fan/Exhaust fan/ Air circulator of any sweep/size/make from site and handed over to MES store including proper cleaning.
Taking down of light fittings of any type/make from site complete all as specified and directed.
Taking down unserviceable submain wiring of any size complete all as specified and directed.
Taking down unserviceable DBs/AC Box/Flame proof fittings etc with accessories complete.
Taking down unserviceable XLPE Cable of any type and size.
Disconnecting the AC plant from power spply and dismantling the AC plant of capacity 5.5 TR (3 Nos) along with connected ducting and pipe line complete all as directed and depositing the same to MES store yard at AGE E/M-II U-II. Note - The rate quoted deemed to include cost of all T&P including transportation.
Taking down CI pipe of 150 mm size incl all fittings complete all as specified and directed.
Supplying and laying ductile pipe with double flanged centrifugally cast(spun) class K-9 of 150 mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning.
Taking down MS pipe 200 mm size incl all fittings complete all as specified and directed.
S&F CI sluice valve of 150 mm dia, flanged conforming to IS 14846 PN 1.6 complete all as specified
S&F MS ERW pipe 200 mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and directed.
S&F CI sluice valve of 200 mm dia, flanged conforming to IS 14846 PN 1.6 complete all as specified.
PILE FOUNDATION
Boring for bored cast–in–situ piles 500mm dia in any type of soil/Soft disintegrated rock except hard rock and getting out and disposal of soil outside MoD land using Rotary drilling method by Hydraulic Rotary Rig by DMC method complete all as specified and directed.
Boring for bored cast–in–situ piles 500mm dia in hard rock and getting out and disposal of soil outside MoD land using Rotary drilling method by Hydraulic Rotary Rig by DMC method complete all as specified and directed.
Carrying out initial load test on 500mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out routine load test on 500mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out low strain integrity test on bored cast in situ piles including analysing the result as per ASTM D 5882 and as directed.
Carrying out lateral load test on cast in situ piles 500 mm dia piles as specified in IS and directed.
Carrying out pull out test on cast on situ piles 500 mm dia pile as per specified in IS ,complete all as specified
Schedule ‘A’, Part- XXII, Phase- II Outsourcing of Services for Operation of Central AC Plants (Water Cooled) 3x60 TR (02 Nos. running & 01 No. standby) as provided under this contract as per BOQ for 1st year after successful completion of Phase-II testing i.e. 1st year during defect Liability Period complete including Cooling Towers, AHUs, Electric Control Panels, Pumps and connected equipments in complete AC system, round the clock in 3 shifts of Eight Hours each to ensure smooth and trouble free operation of plants to the entire satisfaction of Dept. by providing services of One Skilled Technician of AC & Refrigeration (ITI Qualified with 03 years relevant experience) in each Shift of 08 hours complete all as specified and as directed.
Schedule ‘A’, Part- XXIII, Phase- III Outsourcing of Services for Operation of Central AC Plants (Water Cooled) 3x60 TR (02 Nos. running & 01 No. standby) as provided under this contract as per BOQ for 2nd year after successful completion of Phase-II testing i.e. 2nd year during defect Liability Period complete including Cooling Towers, AHUs, Electric Control Panels, Pumps and connected equipments in complete AC system, round the clock in 3 shifts of Eight Hours each to ensure smooth and trouble free operation of plants to the entire satisfaction of Dept. by providing services of One Skilled Technician of AC & Refrigeration (ITI Qualified with 03 years relevant experience) in each Shift of 08 hours complete all as specified and as directed.
Schedule ‘A’, Part- XXIV, Phase- IV Outsourcing of Services for Operation of Central AC Plants (Water Cooled) 3x60 TR (02 Nos. running & 01 No. standby) as provided under this contract as per BOQ for 3rd Year after successful completion of Phase-II testing i.e. 1st year after defect Liability Period complete including Cooling Towers, AHUs, Electric Control Panels, Pumps and connected equipments in complete AC system, round the clock in 3 shifts of Eight Hours each to ensure smooth and trouble free operation of plants to the entire satisfaction of Dept. by providing services of One Skilled Technician of AC & Refrigeration (ITI Qualified with 03 years relevant experience) in each Shift of 08 hours complete all as specified and as directed.
Schedule ‘A’, Part- XXV, Phase- V Outsourcing of Services for Operation of Central AC Plants (Water Cooled) 3x60 TR (02 Nos. running & 01 No. standby) as provided under this contract as per BOQ for 4th year after successful completion of Phase-II testing i.e. 2nd year after defect Liability Period complete including Cooling Towers, AHUs, Electric Control Panels, Pumps and connected equipments in complete AC system, round the clock in 3 shifts of Eight Hours each to ensure smooth and trouble free operation of plants to the entire satisfaction of Dept. by providing services of One Skilled Technician of AC & Refrigeration (ITI Qualified with 03 years relevant experience) in each Shift of 08 hours complete all as specified and as directed.
jd constructions (BID ID -3278440)
PJR PROJECT CONSTRUCTIONS PRIVATE LIMITED (BID ID -3278515)
DES RAJ AND SONS BUILDERS PVT LTD (BID ID -3276263)
RAGHUSONS INFRA ENGINEERING PVT. LTD (BID ID -3278694)
SVS PROJECTS (BID ID -3278271)
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD (BID ID -3278488)
Jeet Construction (BID ID -3278400)
Brahma Infra (BID ID -3278630)
Indus Projects Private Limited (BID ID -3278442)
SOOD ASSOCIATES PVT LTD (BID ID -3278548)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid