Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹9.0 L+₹9,288 (1.04%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹9.2 L+₹33,805 (3.80%)Rejected-Finance 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹11.4 L+₹2.5 L (28.4%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹11.9 L
EMD Value
₹23,840
Closing Date
16 Oct 2023, 6:00 pmClosed
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR/MAINT OF VARIOUS CAPACITY OF DG SETS EARTHING OF EQPTS AT RALAWAS UNDER GE BANAR
2023_MES_613246_2
8823/29/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Banar
₹23,840
Yes
29 Nov 2023
20 Sept 2023
18 Oct 2023
20 Sept 2023
16 Oct 2023
27 Sept 2023
Amount
Materials and labour for maintenance and servicing of DG Sets of following capacity complete all as specified and as directed.NOTE: (a) One service of DG Set is termed as ‘EACH JOB’.(b) Minor Spare parts like as rubber gasket,pin,seal etc shall be replaced under servicing without any cost and major parts like as oil filter, diesel filter,air filter & engine oil shall be measured & paid sepratelly under respective items of the schedule as supply only and fixing charge shall deemed to be inculded in the unit rate of this item .
DG set of 320 KVA
DG set of 250 KVA
DG Set of 125 KVA
DG set of 63/62.5 KVA
DG set of 30/40 KVA
Labour only for repair and calibration of FIP of following DG Sets including strip opening and refixing of plunger, washer manifold, injection nozzles etc. all as required and testing after re-fixing on engine and setting the rated RPM complete all as specified and as directed.NOTE: Spare parts shall be measured and paid separately under relevent schedule items
DG set of 320 KVA
DG set of 250 KVA
DG Set of 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity 30/40 KVA
Labour for overhauling of injector nozzles including strip opening and refixing of nozzles, washers, etc. and pressure setting as required for DG Sets of following capacities and replacement of timing shaft with coupling complete all as specified and as directed. NOTE: Spare parts shall be measured and paid separately under seperate under relevent schedule items.
DG set of 320 KVA
DG set of 250 KVA
DG st of 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity 30/40KVA
Labour for complete overhauling of self starter including strip opening and refixing of carbon bush, armature coil, field coil, bush and bendix pinion and other related components to the following capacities DG sets :NOTE: Spare parts shall be measured and paid separately under seperate under relevent schedule items.
DG set of 320 KVA
DG set of 250 KVA
DG Set 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity 30/40KVA
Labour only repair and overhauling of Battery Charging Alternator includingstrip opening and refixing of unserviceable armature coil, carbon set, field coil, clutch patti, bearing etc and other related items as required and re-fixing the same on mountings and testing complete for following capacities DG sets : Note: Spare parts shall be measured and paid separately under seperate seperate under relevent schedule items.
DG set of 320 KVA
DG set of 250 KVA
DG Set 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity 30/40KVA
Labour for repairing of Automatic voltage regulator, Diode forward and reverse, rotating rectifier accessories complete to the following capacity of DG set :- NOTE: Spare parts shall be measured and paid separately under seperate under relevent schedule items .
DG set of 320 KVA
DG set of 250 KVA
DG Set 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity - 30/40 KVA
Strip opening the radiator and cleaning the same by water jet completely and detect the leakage/breakage and repair the radiator by soldering/brazing and testing complete all as specified and as directed for the following capacity of DG Sets :-
DG Set of capacity - 320 KVA
DG Set of capacity - 250 KVA
DG Set capacity - 125 KVA
DG Set of capacity - 63/62.5 KVA
DG Set of capacity - 30/40 KVA
Labour only for taking out burnt out winding and rewinding the alternator main field coil, rotor, exicitor coil, armature of any type with minimum 80kg copper enameled wire including other minor repairs, and testing and re-fixing the alternator after repair with alignment rotor with shaft and coupling with all required accessories for 250/125/100/63 KVA capacity DG set including necessary electrical and earthing connections complete all as specified and as directed.
Supply and top up the coolant K Cool super plus-25/75 complete all as specified.
Supply and changing the engine oil of suitable grade including drain out existing used oil complete all as specified.
Supply only the following items in DG set of 320/250/125 KVA capacity.
Diesel filter element
Oil Filter element
Water pump assy
Air cleaner hose pipe with clamp
Radiator hose pipe with clamp
Safety control valve
flexible pipe for fuel pump to PT pump with banjo washer , nut bolt
flexible pipe for Disel tank to filter with banjo washer , nut bolt
Air cleaner Filter
Oil pump
Automatic voltage regulator
By pass filter
Supply only the following items in DG set of 63/62.5 KVA capacity.
Diesel filter element
Oil Filter element
Air cleaner hose pipe with clamp
Radiator hose pipe with clamp
Safety control valve
flexible pipe for fuel pump to PT pump with banjo washer , nut bolt
flexible pipe for Disel tank to filter with banjo washer , nut bolt
Air cleaner Filter
Oil pump
Automatic voltage regulator
By pass filter
Supply only the following items in DG set of 40/30 KVA capacity.
Diesel filter element
Oil Filter element
Air cleaner hose pipe with clamp
Radiator hose pipe with clamp
flexible pipe for fuel pump to PT pump with banjo washer , nut bolt
flexible pipe for Disel l tank to filter with banjo washer , nut bolt
By pass filter
Automatic voltage regulator
Air cleaner Filter
Supply only following spare parts of Self starter spare parts of capacity 320/250 KVA as per existing make and cat part no-
Self clutch assembly
Self pinion assembly
Self solenoid switch assembly
Self Bandex Assembly
Self carbon rocker assembly
Self carbon brush (set of 4 pcs)
Supply only following spare parts of Battery charging Alternator for DG Set of capacity 320/250 /125 KVA as per existing make and cat part no-
Rectifier assembly
carbon bush (Set of 2 Pcs)
Bearing
Stator assembly
Supply only following spare parts of Battery charging Alternator for DG Set of capacity 30/40/63 KVA as per existing make and cat part no-
Rectifier assembly
carbon bush (Set of 2 Pcs)
Stator assembly
Bearing
Supply only following spare parts of Self starter spare parts of capacity 320/250/125/63 KVA as per existing make and cat part no-
Self clutch assembly
Self solenoid switch assembly
Self carbon brush (set of 4 pcs)
Self carbon rocker assy
Supply only following spare parts of Self starter spare parts of capacity 30/40 KVA as per existing make and cat part no-
Self clutch assembly
Self solenoid switch assembly
Self carbon brush (set of 4 pcs)
Self carbon rocker assy
Supply only following spare parts of FIP spare parts of capacity 320/250 KVA as per existing make and cat No
Element
Delievery valve
FIP Repair kit
Supply only following spare parts of Injector for DG Set of Capacity 320/250 KVA as per existing make and cat No
Injector nozzle
Injector washer
Supply only following spare parts of FIP spare parts of capacity 125/63 KVA as per existing make and cat No
Element
Delievery valve
FIP Repair kit
Supply only following spare parts of Injector for DG Set of Capacity 125/63 KVA as per existing make and cat No
Injector nozzle
Injector washer
Supply only following spare parts of FIP spare parts of capacity 30/40 KVA as per existing make and cat No
Element
Delievery valve
FIP Repair kit
Supply only following spare parts of Injector for DG Set of Capacity 30/40KVA as per existing make and cat No
Injector nozzle
Injector washer
Supply and fixing Engine stop solined switch for DG Set 320/250 as per existing make and cat no
Supply and fixing Engine stop solined switch for DG Set 125/63 as per existing make and cat no
Supply and fixing Engine stop solined switch for DG Set 30/40 as per existing make and cat no
Supply and fixing Alternator Fly wheel ring gear for DG Set 125/100/63 as per existing make and cat no
S&F for battery lead with terminal cable of copper conductor size of 19 SWG and 90cmm long as in repair completed as specified as dirtected by Engr-in-charge
Labour only for taking out burnt out winding and rewinding the Self startor coil, of any type with copper enameled wire including other minor repairs and testing and refixing the Self startor after repair with alignment rotor with shaft and coupling, Copper enameled wire, lumex paper, glass wire varnish and cotton tape etc with all required accessories for 320/250 /125 KVA DG sets including necessary electrical and earthing connections complete all as spedcified and as directed.
Labour only for taking out burnt out winding and rewinding the Self starter coil of any type with copper enameled wire including other minor repairs and testing and refixing the self starter after repair with alignment rotor with shaft and coupling, Copper enameled wire, lumex paper, glass wire varnish and cotton tape etcwith all required accessories for 63 /40/30 KVA DG sets including necessary electrical and earthing connections complete all as spedcified and as directed.
Site visit of OEM service Engineer as per DG set manufacturer for inspection and repair of DG sets as and when required basis as specified and dirtected by EIC Note:- (i) Spare parts shall be measured and paid separately under relevent schedule of items.(ii) All thr visit charge of service enginner of OEM will be paid by Contractor. Max two visit charges will be paid per DG set during inspection,repair and testing complete.(iii) Inspection of DG set of OEM service engineer and recommaded parts for repairs of DG sets/minor defacts rectified on the spot will be consider in Ist visit.(iv) Repairs of DG sets after material by the contractor and testing of DG sets as dirtected by EIC will be considered in 2nd visit.
Labour for servicing & replacement wornout parts ( relays,metering equipments,control circuits etc) of AMF pannel to the following capacity of DG set :- NOTE: Spare parts shall be measured and paid separately items.
DG Set of capacity – 320/250 KVA
DG Set of capacity - 125/63 KVA
DG Set of capacity - 30/40 KVA
Supply only power contactor 4 pole suitable for 320/250KVA DG AMF Panel .
Supply only SMPS for 320/250 KVA DG Set AMF panel
Supply only current transformer 200/5 A set of three for 320/250 KVA DG AMF Panel .
Supply only power fuse link with breaking capacity 80 KA for 320/250 KVA DG AMF Panel .
Supply only relay with board for 320/250 KVA DG AMF Panel .
Supply only controller circuit for 320/250 KVA DG AMF Panel .
Supply only power contactor 4 pole suitable for 125/63/62.5 KVA DG AMF Panel .
Supply only SMPS for 63 KVA DG Set AMF panel
Supply only power fuse link with breaking capacity 80 KA for 63 KVA DG AMF Panel .
Supply only relay with board for 63 KVA DG AMF Panel .
Supply only controller circuit for 63 KVA DG AMF Panel .
Supply only current transformer 200/5 A set of three for 63 KVA DG AMF Panel .
Supply only power contactor 4 pole for 30/35/45 KVA DG AMF Panel .
Supply only SMPS for 30/35/45 KVA DG Set AMF panel
Supply only current transformer 200/5 A set of three for 30/35/45 KVA DG AMF Panel .
Supply only relay with board for 30/35/45 KVA DG AMF Panel .
Supply only controller circuit for 30/35/45 KVA DG AMF Panel .
Supply and fix battery of capacity 150 AH 12V all as specified. Make :- EXIDE new xpress , cat part No XP1500 or equavalent.
Supply and fix battery of capacity 180 AH 12V all as specified. Make :- EXIDE new xpress , cat part No Xp1800 or equavalent.
Supply and fix battery of capacity 120 AH 12V all as specified. Make :- EXIDE new xpress , cat part No Xp1200 or equavalent.
Supply and fix battery of capacity 100 AH 12V all as specified. Make :- EXIDE new xpress , cat part No Xp1000 or equavalent.
Supply fixing and testing Tarbo charger repair kit for DG Set cap 250/125/63 as per existing make and cat no
Supply , fixing and testing Tarbo charger repair kit for DG Set cap 35/40 as per existing make and cat No
Supply and fixing Amper meter for DG set as per existing make any type
Supply and fixing Water temp meter for DG Set as per existing make any tpye
Dismantling of existing earthing and M&L for plate earthing complete with Copper plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than 2.25 metre deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm in alternate layers on all sides and including Copper earth strip 20x3mm bolted (with brass nuts, bolts & check nuts) and rivetted to earth (Plate) electrode at one end and connected to elect pole/main switch board / Neutral of transformer/ body of transformer at the other, earth strip protected by and incl GI pipe 40 mm dia (medium grade) from top of electrode to connecting point with equipment and also incl watering pipe GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover with handle, funnel, wire mesh including necessary excavation & earth work, etc as shown on electrical plate No 5 of SSR Part I.
S&F in repair PVC insulated copper conductor multicore FRLS 3 core 4 sqmm for 1100V conforming to IS-694:2010 complete all specification and directed by Engr-in-Charge
vinayandsons
DIWAKAR CONSTRUCTION CO.
M/s Vishaka Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .