| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC TC 25664 RAJI OPP HOTEL AMRITHA THYCAUD THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.5 L+₹63,173 (5.32%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹12.0 L
EMD Value
₹30,073
Closing Date
29 Aug 2024, 6:00 pmClosed
AEE
PWD Electrical Sub Division Tvpm
DEPOSIT-Tourism Department- Yathri Nivas, Thycadu- Rewiring and Additional Electrical installation in the First and Second floor in connection with civil renovation-work-Electrical AC Work
2024_PWD_687392_1
ESDT/ET_58/2024-25
Open Tender
Electrical Works
Item Rate
300 days
PWD Electrical Sub Division Tvpm
please refer tender documents
5 documents required · 5 mandatory
₹2,760
₹30,073
11 Nov 2024
23 Aug 2024
31 Aug 2024
23 Aug 2024
29 Aug 2024
23 Aug 2024
Amount
SITC of AC
OD49447/2024-2025:Supplying, installation, testing and commissioning of 1 TR and ISEER value grater than or equal to 5 rated inverter type split air conditioner unit complying to IS 1391: 1992 (Part 1 & II) with up-to-date amendments complete with indoor unit, outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410/R32 refrigerant gas. 230V.50 Hz. single phase AC supply, capable of performing- a. Cooling b. Dehumidifying. Air Circulating. d. Filtering including providing wireless remote control unit. 3 metre copper refrigerant piping, wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete. Make :Hitachi/
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
OD43417/2024-2025:Supplying, installation, testing and commissioning of 1.5 TR and ISEER value grater than or equal to 5 rated inverter type split air conditioner unit complying to IS: 1391: 1992 (Part-I & II) with up-to-date amendments complete with indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerant gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumidifying. Air Circulating. d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/ Blue star/Voltas/Panasonic)
OD43419/2024-2025:Supplying, installation, testing and commissioning of 2 TR and ISEER value grater than or equal to 5 rated inverter type split air conditioner unit complying to IS: 1391: 1992 (Part-I & II) with up-to-date amendments complete with indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerant gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumidifying. Air Circulating. d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/Blue star/voltas/Panasonic
OD43420/2024-2025:Dismantling existing 2 TR/1TR -1.5TR split AC units from the second floor including out door and indoor units, indoor connection and stabilizer safely after pumping down and stacked in the ground floor store room
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD43542/2024-2025:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall
OD43472/2024-2025:Supply and fixing of 25mm 10Kg/cm2 PVC drain water pipe line with necessary,supports, saddles,clamps, hangers, and fittings such as bends, tees etc and insulated the entire length of the pipe with 19/25 mm Nitrile or Rubber insulation and covered by a 120 G/nearest size polythene sheet ( max-5cm width) as cladding complete with type as per specifications and as required., all complete as per direction of Engineer-in-Charge
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
OD43473/2024-2025:Supply and fixing additional Copper tube for 1/1.5/2 TR split AC unit (min 22 swg) with PVC insulated and PVC sheared 3 core 4 sq.mm copper conductor, neatly insulated the copper pipe with nitrle rubber form insulation and neatly covered with non adhesive white colour PVC/Polyethylene tap and clamping the entire neatly on wall/surface required suitable size and quantity metal saddle and screws as required
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD45078/2024-2025:Charges for filling sufficient quantity of Refregerant 22/32/410A gas for existing air conditioner unit including leak testing rectifying the defects leak arresting including breezing and make the compressor in good working condition for the following. 1TR/2TR/3TR AC unit
OD45408/2024-2025:Dismantling, Servicing, petty repairing and refitting of 1TR/1.5TR/ 2TR/3TR 240/415V , Wall Mounting type Split Air Conditioner Units covering all maintenance and rectifying the defects if any (excluding the cost of spare). The cleaning and servicing of IDU and ODU includes water servicing using chemicals, water pump, Checking electrical connection , tight mechanical parts and finally patch work etc. The operating status of the units should be monitored and intimated to the department staff in charge and the Air conditioner Units should be maintained in proper working condition.
sudeesh babu v s
Bidder Name
Seven Seas Infotech Systems
sudeesh babu v s
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1069556.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .