Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.7 LAccepted-AOC | 1 | Accepted-AOC 1 | |
| 2 | 2₹14.9 L+₹22,149 (1.51%)Rejected-AOC | 2 | Rejected-AOC 2 |
Tender Value
₹14.7 L
EMD Value
₹36,783
Closing Date
27 Mar 2025, 2:00 pmClosed
Assistant Engineer
LID and EW Section/ Poothadi GP/ Wayand
Poothadi GP 2024-25/ Pr 176/ DRINKING WATER PROJECT IN VARIOUS WARDS/ Amount 1773000/ Electrical Work
2025_LSGD_752375_56
AE/ PDY/ TR/ 04/ 2024-25
Open Tender
Electrical Works
Item Rate
180 days
Poothadi Grama Panchayath
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹36,783
Yes
14 Jun 2025
20 Mar 2025
28 Mar 2025
20 Mar 2025
27 Mar 2025
20 Mar 2025
Amount
CHERUKUNNU RENOVATION DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD519115/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
OD491309/2024-2025:Supply and fixing 32 A, 2 Way Bakelite neutral links mounted on DMC/SMC base
OD491311/2024-2025:Supply and fixing of 32 ampere Bakelite HRC fuse with HRC fuse-link with connections in existing meter board.
OD491318/2024-2025:Supply and installation testing and commissioning of 2HP 4 inch borewell submersible pumpsets suitable for Single phase, 220V 50 Hz, AC supply conform to relevant ISS. Head 53/113/125 m,with a flow rate of 4000/1900/1000 LPh and should provide 2000 LPH at a head of 112m with standard size delivery pipe (1.25inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo- SE225/Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD491308/2024-2025:Supply and installation of L&T MR-G2 Single phase submersible pump controller 0.5 to 2HP with inbuilt indicators, ammeter, voltmeter,contactor, capacitors etc.
OD491317/2024-2025:Supply and connect a 1.25 inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD491315/2024-2025:Supply and installation of 1.25 inch Cast iron barrel nipple
OD491314/2024-2025:Supply and providing 1.25 inch or nearest size dia Gun metal non return valve (ISI)
OD491313/2024-2025:Supply and fix 1.25 inch or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD491316/2024-2025:Supply and providing 1.25 inch or nearest size stainless steel Hose collar with hose clip
OD491310/2024-2025:Supply and installation of 1- inch Cast Iron barrel nipple
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD491312/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
90.3.18.4:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.50 mm dia with clamps made from 25 x 3 mm MS flat
MANALVAYAL PANIYA COLONY DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD519116/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD491369/2024-2025:Supply and fixing 32 A, 2 way bakelite Neutral link mounted on DMC/SMC base with connection,in the existing meter board
OD491370/2024-2025:Supply and fixing of 32 A,Bakelite HRC fuse with HRC fuse link
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.3.3:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board
OD491374/2024-2025:Supply and installation testing and commissioning 1HP open well submersible, Monoblocks,Horizontal type Water cooled motor pump set having 2900 RPM, suitable for Single phase, 240V 50 Hz, AC supply conform to relevant ISS. Head 20/28 m,with a flow rate of 200/90 LPM and should provide 200 LPM at a head of 20m , 90LPM at a head of 28m with standard size delivery pipe (1inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo-ASM SP 625/Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD491396/2024-2025:S & F Motor starters of the following ratings submersible pump controller with ammeter , voltmeter , push buttons, capacitor, indicator with IP 54 for single phase 140-270 V, 1-2 hp pump set. Overload relay range 13.2-20 Amp with dimensions 8x4x10xcm and a minimum of one year warranty (Havels ,L&tT
OD491379/2024-2025:Supply and connect a 1- inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD491380/2024-2025:Supply and installation of 1- inch Cast iron barrel nipple
OD491381/2024-2025:Supply and providing 1- inch or nearest size stainless steel Hose collar with hose clip
OD491382/2024-2025:Supply and fix 1- inch or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD491383/2024-2025:Supply and installation of 1- inch full way valve
OD491384/2024-2025:Supply and providing 1- inch or nearest size dia Gun metal non return valve (ISI)
OD491403/2024-2025:Supply and fix flat iron clamps made from 32 mm flat iron clamps with suitable size bolts and nuts for fixing delivery pipe on the top of the well as required
OD491404/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
90.3.18.4:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.50 mm dia with clamps made from 25 x 3 mm MS flat
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
ANAPPANTHI DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD519118/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD491425/2024-2025:Supply and fixing 32 A, 2 way bakelite Neutral link mounted on DMC/SMC base with connection,in the existing meter board
OD491426/2024-2025:Supply and fixing of 32 A,Bakelite HRC fuse with HRC fuse link
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.3.3:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board
OD491430/2024-2025:Supply and installation testing and commissioning of 2 HP open well submersible, Monoblocks, Water cooled motor pump suitable for Single phase, 200V 50 Hz, AC supply conform to relevant ISS. Head 22/37/55 m,with a flow rate of 9000/6800/3200 LPH and should provide 9000 LPH at a head of 22 m, 6800 LPH at a head of 37 m, 3200 LPH at a head of 55 m with standard size delivery pipe (1.5 inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo- TC0806 /Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD491431/2024-2025:S & F Motor starters of the following ratings submersible pump controller with ammeter , voltmeter , push buttons, capacitor, indicator with IP 54 for single phase 140-270 V, 1-2 hp pump set. Overload relay range 13.2-20 Amp with dimensions 8x4x10xcm and a minimum of one year warranty (Havels ,L&tT
OD491432/2024-2025:Supply and connect a 1.5 inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD491433/2024-2025:Supply and installation of 1.5 inch full way valve
OD491434/2024-2025:Supply and fix 1.5 inch or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD491435/2024-2025:Supply and installation of 1.5 - inch Cast iron barrel nipple
OD491440/2024-2025:Supply and providing 1.5 inch or nearest size dia Gun metal non return valve (ISI)
OD491437/2024-2025:Supply and providing 1.5 inch or nearest size stainless steel Hose collar with hose clip
OD491442/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
OD491466/2024-2025:Supply and fix flat iron clamps made from 50 mm flat iron clamps with suitable size bolts and nuts for fixing delivery pipe on the top of the well as required
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
KOTTAKKOLLY DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD519119/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD491482/2024-2025:Supply and fixing 32 A, 2 way bakelite Neutral link mounted on DMC/SMC base with connection,in the existing meter board
OD491483/2024-2025:Supply and fixing of 32 A,Bakelite HRC fuse with HRC fuse link
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.3.3:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board
OD491485/2024-2025:Supply and installation testing and commissioning of 2HP 4 inch borewell submersible pumpsets suitable for Single phase, 220V 50 Hz, AC supply conform to relevant ISS. Head 53/113/125 m,with a flow rate of 4000/1900/1000 LPh and should provide 2000 LPH at a head of 112m with standard size delivery pipe (1.25inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo- SE225/Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD491502/2024-2025:Supply and installation of L&T MR-G2 Single phase submersible pump controller 0.5 to 2HP with inbuilt indicators, ammeter, voltmeter,contactor, capacitors etc.
OD491492/2024-2025:Supply and connect a 1.25 inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD491493/2024-2025:Supply and installation of 1.25 inch Cast iron barrel nipple
OD491494/2024-2025:Supply and providing 1.25 inch or nearest size dia Gun metal non return valve (ISI)
OD491495/2024-2025:Supply and fix 1.25 inch or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD491496/2024-2025:Supply and installation of 1.25 inch full way valve
OD491497/2024-2025:Supply and providing 1.25 inch or nearest size stainless steel Hose collar with hose clip
OD491518/2024-2025:Supply and fix flat iron clamps made from 40 mm flat iron clamps with suitable size bolts and nuts for fixing delivery pipe on the top of the well as required
OD491519/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
NELLIKKARA LAKSHAMVEED DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD519124/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD491660/2024-2025:Supply and fixing 32 A, 2 way bakelite Neutral link mounted on DMC/SMC base with connection,in the existing meter board
OD491661/2024-2025:Supply and fixing of 32 A,Bakelite HRC fuse with HRC fuse link
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.3.3:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board
OD502663/2024-2025:Supply and installation testing and commissioning 1HP open well submersible, Monoblocks,Horizontal type Water cooled motor pump set having 2900 RPM, suitable for Single phase, 240V 50 Hz, AC supply conform to relevant ISS. Head 20/32 m,with a flow rate of 200/90 LPM and should provide 200 LPM at a head of 20m , 90LPM at a head of 28m with standard size delivery pipe (1inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo/Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD502649/2024-2025:Supply and installation of L&T MR-G2 Single phase submersible pump controller 0.5 to 2HP with inbuilt indicators, ammeter, voltmeter,contactor, capacitors etc.
OD502650/2024-2025:Supply and fix flat iron clamps made from 32 mm flat iron clamps with suitable size bolts and nuts for fixing delivery pipe on the top of the well as required
OD502651/2024-2025:Supply and connect a 1- inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD502652/2024-2025:Supply and installation of 1- inch Cast iron barrel nipple
OD502653/2024-2025:Supply and providing 1- inch or nearest size stainless steel Hose collar with hose clip
OD502654/2024-2025:Supply and fix 1- inch or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD502655/2024-2025:Supply and installation of 1- inch full way valve
OD502656/2024-2025:Supply and providing 1- inch or nearest size dia Gun metal non return valve (ISI)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
90.3.18.4:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.50 mm dia with clamps made from 25 x 3 mm MS flat
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
ATHIRATTUKUNNU-KARAVAYAL DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD519127/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD492009/2024-2025:Supply and fixing 32 A, 2 way bakelite Neutral link mounted on DMC/SMC base with connection,in the existing meter board
OD492010/2024-2025:Supply and fixing of 32 A,Bakelite HRC fuse with HRC fuse link
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.3.3:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board
OD492527/2024-2025:Supply and installation testing and commissioning 1HP open well submersible, Monoblocks,Horizontal type Water cooled motor pump set having 2900 RPM, suitable for Single phase, 240V 50 Hz, AC supply conform to relevant ISS. Head 20/28 m,with a flow rate of 200/90 LPM and should provide 200 LPM at a head of 20m , 90LPM at a head of 28m with standard size delivery pipe (1inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo-ASM SP 625/Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD492528/2024-2025:Supply and installation of L&T MR-G2 Single phase submersible pump controller 0.5 to 2HP with inbuilt indicators, ammeter, voltmeter,contactor, capacitors etc.
OD492537/2024-2025:Supply and connect a 1- inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD492538/2024-2025:Supply and installation of 1- inch Cast iron barrel nipple
OD492539/2024-2025:Supply and providing 1- inch or nearest size stainless steel Hose collar with hose clip
OD492540/2024-2025:Supply and fix 1- inch or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD492541/2024-2025:Supply and installation of 1- inch full way valve
OD492542/2024-2025:Supply and providing 1- inch or nearest size dia Gun metal non return valve (ISI)
OD492536/2024-2025:Supply and fix flat iron clamps made from 32 mm flat iron clamps with suitable size bolts and nuts for fixing delivery pipe on the top of the well as required
OD492543/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
90.3.18.4:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.50 mm dia with clamps made from 25 x 3 mm MS flat
KORIKKUNNU COLONY DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD519129/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD492326/2024-2025:Supply and fixing 32 A, 2 way bakelite Neutral link mounted on DMC/SMC base with connection,in the existing meter board
OD492327/2024-2025:Supply and fixing of 32 A,Bakelite HRC fuse with HRC fuse link
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.3.3:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board
OD502599/2024-2025:Supply and installation testing and commissioning of 2HP 4 inch borewell submersible pumpsets suitable for Single phase, 220V 50 Hz, AC supply conform to relevant ISS. Head 53/113/125 m,with a flow rate of 4000/1900/1000 LPh and should provide 2000 LPH at a head of 112m with standard size delivery pipe (1.25inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo/Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD502610/2024-2025:S & F Motor starters of the following ratings submersible pump controller with ammeter , voltmeter, pushbuttons, capacotor, indicator with IP 54 for single phase 140-270 V, 1-2 hp pumpset. Overload relay range 13.2-20 Amp with dimensions 8x4x10 cm and a minimum of one year warranty.( Havels, L&amp;T)
OD502611/2024-2025:Supply and connect a 1.25 inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD502612/2024-2025:Supply and installation of 1.25 inch Cast iron barrel nipple
OD502613/2024-2025:Supply and providing 1.25 inch or nearest size dia Gun metal non return valve (ISI)
OD502614/2024-2025:Supply and fix 1.25 inch or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD502615/2024-2025:Supply and installation of 1.25 inch full way valve
OD502616/2024-2025:Supply and providing 1.25 inch or nearest size stainless steel Hose collar with hose clip
OD502631/2024-2025:Supply and fix flat iron clamps made from 40 mm flat iron clamps with suitable size bolts and nuts for fixing delivery pipe on the top of the well as required
OD502618/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
90.3.18.4:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.50 mm dia with clamps made from 25 x 3 mm MS flat
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
VRINDAVAN COLONY DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD519130/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD492104/2024-2025:Supply and fixing 32 A, 2 way bakelite Neutral link mounted on DMC/SMC base with connection,in the existing meter board
OD492105/2024-2025:Supply and fixing of 32 A,Bakelite HRC fuse with HRC fuse link
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.3.3:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board
OD502665/2024-2025:Supply and installation testing and commissioning 1HP open well submersible, Monoblocks,Horizontal type Water cooled motor pump set having 2900 RPM, suitable for Single phase, 240V 50 Hz, AC supply conform to relevant ISS. Head 20/32 m,with a flow rate of 200/90 LPM and should provide 200 LPM at a head of 20m , 90LPM at a head of 28m with standard size delivery pipe (1inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo/Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD500054/2024-2025:S & F Motor starters of the following ratings submersible pump controller with ammeter , voltmeter, pushbuttons, capacotor, indicator with IP 54 for single phase 140-270 V, 1-2 hp pumpset. Overload relay range 13.2-20 Amp with dimensions 8x4x10 cm and a minimum of one year warranty.( Havels, L&amp;T)
OD492544/2024-2025:Supply and connect a 1- inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD492545/2024-2025:Supply and installation of 1- inch Cast iron barrel nipple
OD492546/2024-2025:Supply and providing 1- inch or nearest size stainless steel Hose collar with hose clip
OD492547/2024-2025:Supply and fix 1- inch or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD492548/2024-2025:Supply and installation of 1- inch full way valve
OD492549/2024-2025:Supply and providing 1- inch or nearest size dia Gun metal non return valve (ISI)
OD492562/2024-2025:Supply and fix flat iron clamps made from 32 mm flat iron clamps with suitable size bolts and nuts for fixing delivery pipe on the top of the well as required
OD492550/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
90.3.18.4:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.50 mm dia with clamps made from 25 x 3 mm MS flat
CHEENGODU DWS ELECTRIICATION
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD492200/2024-2025:Supply and fixing of 9W LED
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD519136/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
OD492558/2024-2025:Supply and installation testing and commissioning of 2 HP open well submersible, Monoblocks, Water cooled motor pump suitable for Single phase, 200V 50 Hz, AC supply conform to relevant ISS. Head 22/37/55 m,with a flow rate of 9000/6800/3200 LPH and should provide 9000 LPH at a head of 22 m, 6800 LPH at a head of 37 m, 3200 LPH at a head of 55 m with standard size delivery pipe (1.5 inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo- TC0806 /Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD492551/2024-2025:Supply and installation of L&T MR-G2 Single phase submersible pump controller 0.5 to 2HP with inbuilt indicators, ammeter, voltmeter,contactor, capacitors etc.
OD492552/2024-2025:Supply and connect a 1.5 inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD492553/2024-2025:Supply and installation of 1.5 inch full way valve
OD492554/2024-2025:Supply and fix 1.5 inch or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD492555/2024-2025:Supply and installation of 1.5 - inch Cast iron barrel nipple
OD492556/2024-2025:Supply and providing 1.5 inch or nearest size dia Gun metal non return valve (ISI)
OD492557/2024-2025:Supply and providing 1.5 inch or nearest size stainless steel Hose collar with hose clip
OD492560/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
OD492235/2024-2025:Supply and installation of dust and vermin proof single phase sintex meter board (GS MB -3525) 350*250*150 and to fix KSEB meters , fuse unit etc. as required including fixing it on the wall , making good the damages, colour washing ,etc. as required
OD492209/2024-2025:Supply and fixing 32 A, 2 way bakelite Neutral link mounted on DMC/SMC base with connection,in the existing meter board
OD492210/2024-2025:Supply and fixing of 32 A,Bakelite HRC fuse with HRC fuse link
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
PANGUMOOPPAN NAGAR DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD500061/2024-2025:Supply and fixing of 9W LED
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD502463/2024-2025:Supply and installation testing and commissioning of 7.5 HP 3 stage Horizontal openwell multistage submersible Pumpset for Three phase, 380V 50 Hz, AC supply conform to relevant ISS. Head 29/76 m,with a flow rate of 450/120 LPM and should provide 450 LPM at a head of 29 m, 120 LPM at a head of 76 m with standard size delivery pipe (2 inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo /Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD502466/2024-2025:S & F Motor of the following rating DOL starter for 7.5 HP motor (L&T MUG10 ) or equivalent with dry run protection, overload set relay, single phase preventer , voltmeter , ammeter and with wide band coil
OD502465/2024-2025:Supply and installation of L&T Dry run protection relay for 3 phase motor pumpset
OD502464/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
OD502508/2024-2025:Supply and installation of 2 inch cast iron ball valve.
OD502510/2024-2025:Supply and installation of 63mm dia or nearest size Cast iron NRV, flange and flap type, conforms to relevant ISI (KARTAR or equivalent brand ).
OD502511/2024-2025:Supply and installation of 63mm dia or nearest size cast iron barrel nipple, confirm to relevant ISI.
OD502512/2024-2025:Supply and fix 63mm dia or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD502513/2024-2025:Supply and installation of 63mm dia or nearest size stainless steel Hose collar with hose clip, conforms to relevant ISI.(with or without hook).
OD502514/2024-2025:Supply and connect 63mm dia or nearest size HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD502526/2024-2025:Supply and fixing 63 A, 2 Way Bakelite neutral links mounted on DMC/SMC base
OD502527/2024-2025:supply and fixing of 63 A Bakelite HRC Fuse Base with HRC Fuse link with connections in existing meter board
OD502528/2024-2025:supply and installation of Sintex meter box (Model -GSMB 2520, Size-250x200x105 mm )
OD502529/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
OD502530/2024-2025:Supply and installation of dust and vermin proof three phase sintex meter board (GS MB -6535) 650*350*250 and to fix KSEB meters , fuse unit , CTs , etc. as required including fixing it on the wall , making good the damages, colour washing ,etc. as required
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
PLAKKOOTTAM UNNATHI DWS ELECTRIFICATION
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD516808/2024-2025:Supply and fixing of 9W LED
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD516918/2024-2025:Supply and installation testing and commissioning of 7.5 HP 3 stage Horizontal openwell multistage submersible Pumpset for Three phase, 380V 50 Hz, AC supply conform to relevant ISS. Head 29/76 m,with a flow rate of 450/120 LPM and should provide 450 LPM at a head of 29 m, 120 LPM at a head of 76 m with standard size delivery pipe (2 inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo /Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD516917/2024-2025:S & F Motor of the following rating DOL starter for 7.5 HP motor L&T MUG10 /kirloskar or equivalent brand with dry run protection, overload set relay, single phase preventer , voltmeter , ammeter and with wide band coil
90.14.24.3:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.3 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type suitable for direct connection to motors.
OD516931/2024-2025:Supply and installation of L&T Dry run protection relay for 3 phase motor pumpset
OD516946/2024-2025:Supply and connect 63mm dia or nearest size HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD516941/2024-2025:Supply and installation of 2 inch cast iron ball valve.
OD516942/2024-2025:Supply and installation of 63mm dia or nearest size Cast iron NRV, flange and flap type, conforms to relevant ISI (KARTAR or equivalent brand ).
OD516943/2024-2025:Supply and installation of 63mm dia or nearest size cast iron barrel nipple, confirm to relevant ISI.
OD516944/2024-2025:Supply and fix 63mm dia or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD516945/2024-2025:Supply and installation of 63mm dia or nearest size stainless steel Hose collar with hose clip, conforms to relevant ISI.(with or without hook).
OD516930/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD516978/2024-2025:Supply and fixing 63 A, 2 Way Bakelite neutral links mounted on DMC/SMC base
OD516979/2024-2025:supply and fixing of 63 A Bakelite HRC Fuse Base with HRC Fuse link with connections in existing meter board
OD516980/2024-2025:supply and installation of Sintex meter box (Model -GSMB 2520, Size-250x200x105 mm )
OD516981/2024-2025:Supplying and fixing TPN sheet steel enclosure on surface/ recess along with 32/40/63 amps 415 volts 4 Pole isolator complete with connections, testing and commissioning etc. as required.
OD516982/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system
OD516983/2024-2025:Supply and installation of dust and vermin proof three phase sintex meter board (GS MB -6535) 650*350*250 and to fix KSEB meters , fuse unit , CTs , etc. as required including fixing it on the wall , making good the damages, colour washing ,etc. as required
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
KOVALA DWS ELECTRIFICATION
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD516986/2024-2025:Supply and fixing of 9W LED
OD514752/2024-2025:Supply and installation testing and commissioning of 10 HP openwell vertical multistage submersible Pumpset for Three phase, 380V 50 Hz, AC supply conform to relevant ISS. Head 64/170 m and should provide 12000 LPH at a head of 140 m with standard size delivery pipe (2 inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/(Texmo- EAVM 30J/10 ) /Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD514753/2024-2025:Supply and installation of FASD starer for 10 HP motor (L&T MUG15 or equivalent brand) with overload set relay , single phasing preventer , phase reversal and phase unbalance protection , proven and tested MK1 contactor, indication of power ON and pump ON, auto restart (with variable 30 sec-5 min ON delay) , dual voltmeter and ammeter and with wide band coil operates rom 65% to 110% of ratedcoil voltage.
OD514754/2024-2025:Supply and installation of L&T Dry run protection relay for 3 phase motor pumpset
90.14.24.4:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.4 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Capacitor suitable for direct connection to motors.
OD514756/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
OD514757/2024-2025:Supply and installation of 2 inch cast iron ball valve.
OD514758/2024-2025:Supply and fixing flat iron clamps made from 63 mm flat iron clamp with suitable size bolt and nut for fixing delivery pipe on the top of the well as required
OD514759/2024-2025:Supply and installation of 63mm dia or nearest size Cast iron NRV, flange and flap type, conforms to relevant ISI (KARTAR or equivalent brand ).
OD514760/2024-2025:Supply and installation of 63mm dia or nearest size cast iron barrel nipple, confirm to relevant ISI.
OD514761/2024-2025:Supply and fix 63mm dia or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD514762/2024-2025:Supply and installation of 63mm dia or nearest size stainless steel Hose collar with hose clip, conforms to relevant ISI.(with or without hook).
OD514763/2024-2025:Supply and connect 63mm dia or nearest size HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD514779/2024-2025:Supply and fixing 63 A, 2 Way Bakelite neutral links mounted on DMC/SMC base
OD514780/2024-2025:supply and fixing of 63 A Bakelite HRC Fuse Base with HRC Fuse link with connections in existing meter board
OD514781/2024-2025:Supply and installation of dust and vermin proof three phase sintex meter board (GS MB -6535) 650*350*250 and to fix KSEB meters , fuse unit , CTs , etc. as required including fixing it on the wall , making good the damages, colour washing ,etc. as required
OD514782/2024-2025:Supply, provide and fix the following capacity TPN disconnector fuse switch unit in a sheet steel enclosure with ISI marked HRC fuse on wall/angle iron frame including drilling holes in the frame, making connections,etc. as required.63 A TPN
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.13:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
IRULAM MICHABHOOMI DWS ELECTRIFICATION
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD518610/2024-2025:Supply and fixing of 9W LED
OD518655/2024-2025:Supply and installation testing and commissioning of 10 HP openwell vertical multistage submersible Pumpset for Three phase, 380V 50 Hz, AC supply conform to relevant ISS. Head 64/170 m and should provide 12000 LPH at a head of 140 m with standard size delivery pipe (2 inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/(Texmo- EAVM 30J/10 ) /Crompton/Deccan or equivalent brands),conforms to IS 14220/1.
OD518657/2024-2025:Supply and installation of FASD starer for 10 HP motor (L&T MUG15 or equivalent brand) with overload set relay , single phasing preventer , phase reversal and phase unbalance protection , proven and tested MK1 contactor, indication of power ON and pump ON, auto restart (with variable 30 sec-5 min ON delay) , dual voltmeter and ammeter and with wide band coil operates rom 65% to 110% of ratedcoil voltage.
90.14.24.4:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.4 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Capacitor suitable for direct connection to motors.
OD518658/2024-2025:Supply and installation of L&T Dry run protection relay for 3 phase motor pumpset
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD518678/2024-2025:Supply and connect 63mm dia or nearest size HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors.
OD518674/2024-2025:Supply and installation of 63mm dia or nearest size Cast iron NRV, flange and flap type, conforms to relevant ISI (KARTAR or equivalent brand ).
OD518675/2024-2025:Supply and installation of 63mm dia or nearest size cast iron barrel nipple, confirm to relevant ISI.
OD518676/2024-2025:Supply and fix 63mm dia or nearest size GI flange with the required bolt, nut, washer and gasket etc.
OD518677/2024-2025:Supply and installation of 63mm dia or nearest size stainless steel Hose collar with hose clip, conforms to relevant ISI.(with or without hook).
OD518673/2024-2025:Supply and laying of 20mm or nearest size Nylon rope
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD518726/2024-2025:Supply and fixing 63 A, 2 Way Bakelite neutral links mounted on DMC/SMC base
OD518727/2024-2025:supply and fixing of 63 A Bakelite HRC Fuse Base with HRC Fuse link with connections in existing meter board
OD518728/2024-2025:supply and installation of Sintex meter box (Model -GSMB 2520, Size-250x200x105 mm )
OD518729/2024-2025:Supply and installation of dust and vermin proof three phase sintex meter board (GS MB -6535) 650*350*250 and to fix KSEB meters , fuse unit , CTs , etc. as required including fixing it on the wall , making good the damages, colour washing ,etc. as required
OD518730/2024-2025:Supply, provide and fix the following capacity TPN disconnector fuse switch unit in a sheet steel enclosure with ISI marked HRC fuse on wall/angle iron frame including drilling holes in the frame, making connections,etc. as required.63 A TPN
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.7.13:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
ABDUL NAZER K (BID ID -2178891)
Bidder Name
ABDUL NAZER K
SOMAN K
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .