Loading…
Loading…
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
17 Jun 2026, 6:00 pm
Harikesh Meena EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2026_MES_762083_2
8982
Open Tender
Civil Works
270 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹300
GE ARMY BARODA
₹10,000
Yes
4 Jun 2026
4 Jun 2026
18 Jun 2026
4 Jun 2026
17 Jun 2026
12 Jun 2026
Supply only Sealed Compressor unit of capacity 5.5 TR three phase 415 Volt, 50Hz
Supply only PCB for 11/16.5 TR Package type as per existing board make and model or as per site requirement complete all as specified and directed
Supply only Contactors for blower motor and compressor
Supply only Expansion valve
Supply only Dryers
Supply only Fan motor for 11 TR plant outdoor unit
Supply only HP relay switch for compressor unit of 11 TR / 16.5 TR AC plant
Supply only LP relay switch for compressor unit of 11 TR / 16.5 TR AC plant
Supply only SPDT relay switch for 11 TR / 16.5 TR plant outdoor unit
Supply only Heating condensing coil for 11 TR / 16.5 TR plant Outdoor unit
Supply only Evaporator coil for 11 TR / 16.5 TR plant indoor unit
Supply only Temperature Sensor for 11 TR / 16.5 TR plant
Supply only MCCB 163 Amps 4 Pole 16 KA 415 Volt, 50Hz
Supply only MCCB 200 Amps 4 Pole 16 KA 415 Volt, 50Hz
Supply only Fan motor for 16.5 TR plant outdoor unit
M & L for package type A/C plant of capacity 11 / 16.5 TR comprises with out door/indoor unit of make BLUE STAR as directed by Engr-in-charge U/S parts of the machine including labour only for taking out blower motor and saft including lathe work if required and refixing the same to smooth functioning of the plant all as directed and testing complete on completion.
Repair only PCB for 11/16.5 TR Package type as per existing make and model or site requirment PCB card for split AC for indoor unit.
Repair / Rewinding of Blower Motor of Capacity 3/4 HP by taking out burnt winding wires from core, cleaning thoroughly and rewinding the same with bar insulated copper winding wire of proper gauge and turn to achieve required r.p.m and install the motor at its existing position and connected with the system. Existing DE and NDE bearings to be replaced with new bearings (SKF/NBC) and cost is deemed to be included with unit rate.
Charging Refrigerant gas R-407
Comprehensive maintenance/Servicing of air conditioners of Split type AC 1.0/1.5 Ton capacity installed at various location, including oiling/greasing the blower motor, bearings etc, cleaning the air filter pad, evaporator, condensor coils filter externally to remove the dust, replacement of defective parts all as directed by Engr-In Charge (Comprehensive maintenance also includes dismantling of outer/inner unit of spilit AC/window AC of any capacity after repairing the AC will be re-installed properly to same place). Note:- Spare parts, gas charging shall be measured and paid separately. Note: (i) T&P & suitable ladder required at site is responsible to the contractor.
All as per item no 6 but Split type AC 2.0 Ton capacity
Supply and fixing in replacement of inverter/Non inverter PCB of capacity 1.5 Ton for split AC as per existing make and model or site requirment PCB card for split AC for indoor unit.
Supply and fixing in replacement of inverter/non inverter PCB of capacity 1.5 Ton for split AC as per existing make and model or site requirment PCB card for split AC for outdoor unit.
Repair only of inverter/non inverter PCB of capacity 1.5 Ton for split AC as per existing make and model or site requirment PCB card for split AC for indoor unit.
Repair only of inverter/non inverter PCB of capacity 1.5 Ton for split AC as per existing make and model or site requirment PCB card for split AC for indoor unit.
Supply and fixing in replacement of Blower motor 1/5 HP single phase F.H.P. type 230 volts 50 Hz for window type AC including connecting, testing & commissioning(as per site model). Make : GE/Polar/Crompton
Supply and fixing in replacement of Starting capacitor suitable for window/split type AC capacity upto 2.0 Ton
Supply and fixing in replacement of Running capacitor suitable for window /split type AC capacity upto 2.0 Ton
S & F in replacement of Fan/Blower blade for split type AC upto 1.5 Ton capacity all as specified and directed by Engr-In-Charge
S & F in replacement of Blower motor for indoor unit of 1.5Ton capacity split type AC. Make : ISI marked
S & F in replacement of Blower motor for indoor unit of 2.0 Ton capacity split type AC. Make : ISI marked
S & F in replacement of Condensor fan motor for outdoor unit of split type AC 1.5 Ton capacity. Make : ISI marked
S & F in replacement of Condensor fan motor for outdoor unit of split type AC 2.0 Ton capacity. Make : ISI marked
Note:For Item No 1 to 19:-(i) During DLP/contract running time, contractor shall be liable with manufacture to provide replacement/repair the unservicable items with any extra cost. (ii) If any above AC and package AC plant be come breakdown, the contractor shall locate the breakdown/fault at site within 12 hrs on intimation by JE/Engr-in-charge.And ensure that the fault and rectified within 12 hrs to 48 hrs failing which as amount of Rs 200 per Hrs will be recovered as panel recovery from any payment due to the contractor after expiry 70 Hrs.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
TenderPages8982.pdf
Tender Documents • 0.33 MB
BOQ_861967.xls
BOQ • 4.85 MB
Download all tender documents and submit your bid