| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance SEUR AURAI BHADOHI SEUR AURAI BHADOHI SEUR AURAI BHADOHI BHADOHI UTTAR PRADESH 221301 | BHADOHI | UTTAR PRADESH | 221301 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical NOT OK |
Tender Value
Refer Docs
EMD Value
₹36,730
Closing Date
2 Jun 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC BHADOHI
SE EDC BHADOHI
Shifting of pole of Durgaganj Gopiganj Mirzapur (Durgaganj Danupur Gerai Marg) in the deposit scheme 2025-26 in the area of edd gopiganj
2025_PVVNV_1031337_2
02/EDC(Bh)/2025-26
Open Tender
Electrical Works
Lump-sum
90 days
BHADOHI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE EDD I BHADOHI
₹36,730
11 Jun 2025
19 May 2025
3 Jun 2025
19 May 2025
2 Jun 2025
19 May 2025
Amount
Supply and Errection of Decentralised materials given by Contractor Note- Consumable Material (nut&bolt&clamp) which is given by contractor.
nut and bolt all size
suspension Clamp
I hook clamp
dead end clamp
11 kv F clamp
clamp for 33 kv top 11 kv top & T off
cross arm holding clamp with nuts and bolt
Clamp for LT distribution box with nuts and bolt
ERECTION OF WORK Note:- All Centralised Materials will be provided by Department at Store.
Carriage of 11 kv 8.5 Mtr Long PCC Pole from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 11 kv 8.5 Mtr Long PCC Pole with all fitting as per respo Norms.
Carriage of 33 kv 9 Mtr Long PCC Pole from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 33 kv 9 Mtr Long PCC Pole with all fitting as per respo Norms.
Carriage of 33 kv 11 mtr STP Pole from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 33 kv 11 mtr STP Pole with all fitting as per respo Norms.
Carriage of 33 kv Dog conductor from store to site (Accroding to Estimate) with lodding and unlodding.
Errection/laying of 33 kv Dog conductor with all fitting as per respo Norms
Carriage of ACSR weasel conductor from store to site (Accroding to Estimate) with lodding and unlodding.
Errection/laying of ACSR Weasel conductor with all fitting as per respo Norms
Carriage of 33 kv XLPE cable 3x300 sqmm from store to site (Accroding to Estimate) with lodding and unlodding.
Errection/laying of 33 kv 33 kv XLPE cable 3x300 sqmm with all fitting as per respo Norms
Carriage of 33 kv Jointing Kit OD 3X300sqmm from store to site (Accroding to Estimate) with lodding and unlodding.
Errection 33 kv Jointing Kit OD 3X300sqmm with all fitting as per respo Norms
Carriage of 11 kv Jointing Kit OD 3X70sqmm from store to site (Accroding to Estimate) with lodding and unlodding.
Errection 11 kv Jointing Kit OD 3X70sqmm with all fitting as per respo Norms
Carriage of Stay Wire from store to site (Accroding to Estimate) with lodding and unlodding.
Errection Stay Wire with all fitting as per respo Norms
Carriage of substation base from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of substation base with all fitting as per respo Norms.
Carriage of 33 kv Top channel from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 33 kvTop channel with all fitting as per respo Norms.
Carriage of 11 kv Top channel from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 11 kvTop channel with all fitting as per respo Norms.
Carriage of 11 kv Dropper channel from store to site (Accroding to Estimate) with lodding and unlodding.
Errection 11 kv Dropper channel with all fitting as per respo Norms.
Carriage of 11 kv Pin Insulator with pin from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 11 kv Pin Insulator with pinwith all fitting as per respo Norms.
Carriage of 33 kv Pin Insulator with pin from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 33 kv Pin Insulator with pinwith all fitting as per respo Norms.
Carriage of 11 kv Disc Insulator with fitting site (Accroding to Estimate) with lodding and unlodding.
Errection of 11 kv Disc Insulator with fitting with all fitting as per respo Norms.
Carriage of 33 kv Disc Insulator with fitting site (Accroding to Estimate) with lodding and unlodding.
Errection of 33 kv Disc Insulator with fitting with all fitting as per respo Norms.
Carriage of 11 kv T OFF channel from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 11 kv T OFF channel with all fitting as per respo Norms.
Carriage of single phase Distribution BOX from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of single phase Distribution BOX with all fitting as per respo Norms.
Carriage of 3 phase Distribution BOX from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 3 phase Distribution BOX with all fitting as per respo Norms.
Carriage of 11 kv V Type Cross arm from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 11 kv V Type Cross arm with all fitting as per respo Norms.
Carriage of 33 kv V Type Cross arm from store to site (Accroding to Estimate) with lodding and unlodding.
Errection of 33 kv V Type Cross arm with all fitting as per respo Norms.
Carriage of Earthing Complete sets from store to site (Accroding to Estimate) with lodding and unlodding.
Errection Earthing Complete sets with all fitting as per respo Norms
Carriage of 33 kv stay Rod complete from store to site (Accroding to Estimate) with lodding and unlodding.
Errection 33 kv stay Rod complete with all fitting as per respo Norms
Carriage of 11 stay rod complete from store to site (Accroding to Estimate) with lodding and unlodding.
Errection 11 kv stay rod complete with all fitting as per respo Norms
Carriage of ABC cable (3x120+1X95+1X16 sqmm) from store to site (Accroding to Estimate) with lodding and unlodding.
Errection/Laying of ABC cable (3x120+1X95+1X16 sqmm) with all fitting as per respo Norms.
Carriage of ABC cable (3x50+1X35+1X16 sqmm) from store to site (Accroding to Estimate) with lodding and unlodding.
Errection/Laying of ABC cable (3x50+1X35+1X16 sqmm) with all fitting as per respo Norms.
Carriage of ABC cable (3x95+1X70+1X16 sqmm) from store to site (Accroding to Estimate) with lodding and unlodding.
Errection/Laying of ABC cable (3x95+1X70+1X16 sqmm) with all fitting as per respo Norms.
Carriage of ABC cable (1X25+1X16 sqmm) from store to site (Accroding to Estimate) with lodding and unlodding.
Errection/Laying of ABC cable (1X25+1X16 sqmm) with all fitting as per respo Norms.
Carriage of 11 kv xlpe cable 3X70 sqmm from store to site (Accroding to Estimate) with lodding and unlodding.
Errection/Laying of 11 kv xlpe cable 3X70 sqmm with all fitting as per respo Norms.
Carriage of I HOOK from store to site (Accroding to Estimate) with lodding and unlodding.
Errection I HOOK With all fitting as per respo Norms.
Carriage of GI WIRE from store to site (Accroding to Estimate) with lodding and unlodding.
Errection GI WIRE With all fitting as per respo Norms.
Carriage of Gaurding angle from store to site (Accroding to Estimate) with lodding and unlodding.
Errection Gaurding angle With all fitting as per respo Norms.
dismetling and installtion of 63 kva transformer with all fitting
dismetling and installtion of 25 kva transformer with all fitting
dismetling and installtion of 16 kva transformer with all fitting
dismetling and installtion of 10 kva transformer with all fitting
cable laying charge with all fitting
Receive back of all Material as per estimate
Concreting/Grouting of PCC Pole as per respo Norms.
Concreting/Grouting of stay as per respo Norms
M/s Sharada Electricals (BID ID -5230227)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .