Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
15 Feb 2020, 11:00 amClosed
Executive Engineer
EE IPH Indora
Providing LWSS to PC habitation of census Village DPF Lodhwan and Tikri in Tehsil Indora Distt Kangra Sub Head Supply and Errection of submersible and Centrifugal pumping machinery with its allied accessories
2020_HPIPH_34591_1
IND-KNG03-730
Open Tender
Civil Works
Item Rate
180 days
Indora
Please refer Tender documents.
8 documents required · 8 mandatory
₹250
Yes
EE Indora
₹18,400
Yes
4 Mar 2020
5 Feb 2020
15 Feb 2020
6 Feb 2020
15 Feb 2020
6 Feb 2020
Amount
Supply of submersible Pumping Set of BS/SABAR/LUBI/Calama/KSB/Crompton/SU/Johnston conforming to IS-8034-1979(Latest) suitable for clear water fitted with bronze Impellers or suitable alloys directly cooupled to squirrell cage electric Induction Motor of same make as that of Pump conforming to IS:9238-1979(Latest with uptosate ammend-ments) and totally water proof for Submersible duty,isolated from the pump by intermediate casing with double Mechanical seal in oil chamber,grease packed lubricated bearings and provided with stainless steel thrust bearing plate to withstand non-vertical loads with minimum wear and tear. It should also be fitted with a device to take-up expansion of water with the heating of motor including water level guard,erection clamps,cable clips and depth gauge etc. The Pump shall be suitable for operation on data given below:-
Location of site :-The site is located at a distance of 14 Kms.from Nurpur Road Railway Station.
The altitude of place in which :-Altitude of place is 460 Metres above Mean Sea Level. The motor is intended to work:- the Motor is intended to work
Type of current :-A.C.Three phase supply with frequency 50 cycles per second.
Rated Voltage :-415 Vvolts (+/-) 10%
Characterstics of water :-(a).Temperature = 20oC (f) PH =_____ (b).Turbidity =Upto 10NTU (g) Total solids____Mg/Litre ©. Hardness =__Mg/Litre(as CaCo3) (h). Others_____ (d).Alkalinity =__Mg/Litre(as CaCo3)
Depth of Well Assembly :- 100.00 Metres.
L.W.L.in Tube-Well :- 9.14 Metres
Maximum draw down :- 21.33 Metres
Centre line level of Pump :-33.52Metres
Discharge level of highest point:-39.00Metres
Nos.of Pumps required :-2 No.Pump.
Capacity :-7.11 L.P.S.
Total head in Metres :- 33.56 Metres
Length of Rising Main :- 60.00 Metres
Dia of Rising Main :- 125 mmdia GI (MEDIUM CLASS)
No.of working hours per day :-8.00 Hours.
Limits of pump operation :- ( - ) 15% ( + ) 10% of total head.
H.P.of Motor/Drive unit :-Required H.P.of Pump at ( + ) 10% and ( - ) 15% of total head. BHP.with following margins/multiplying factor at duty point,whichever is higher. a).Upto 2 H.P. =1.5 (d) 10 to 20 H.P. =1.2 b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15 c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10
Test Run :-8 Hours continueously for 7 days.
Providing CI double flanged sluice valve of Kirloskar/Kilburn/IVC. V Fouress/Gled/BHEL/Leader make of side dia as per offered pump and class PN 1.0 having one size higher to delivery size of pump and capable of withstanding nominal seat pressure of 10.20kgs/CM2 conforming to IS 780-1984 (P-1)( The size of valve shall be specified by the tenderers)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump(size 125mm.dia and clasas PN 1.0 and shall be suitable for withstanding nominal seat pressure of 10.20kgs. cm<2) conforming to IS: 5312-1984. ( The size of valve shall be specified by the tenderers.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and of size equal of dia of Rising Main i.e. 100mm & clasas PN 1.0 and shall be suitable for withstanding nominal seat pressure of 10.20kgs. cm<2)
Providing and laying suitable size copper PVC.insulated armoured power 3.5 core cable conforming to BIS-1554-Part-I -1988 or latest with uptodate ammendments Siemen/Gloster/ICC make from Meter of HPSEB. to MCB/OCB & from OCB to Busbar Switch & Starter(One cable carrying all three phases) including all other elecrc equipments/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipers or trenches size and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.auithority shall have to be replaced by the tenderer free of cost.The size of cable shall be specified by the tenderers (supply side 4 mm Square.
Providing and laying PVC jointless flat water proof cable 2.5mm square as per BIS-694-1990(Latest with uptodate ammendments) suitable for the pump set offered from OCB to Motor, Motor to Starter including all other electric equipment such as;thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipes or trenches under floor. The type & make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.authoirity,it shall have to be replaced by the tenderer free of cost. The size of cable shall be specified by the tenderer) motor side 2.5 mm Sqr.)
Providing and laying doub le loop earthing with copper plate 600x600x3mm.thick electrode complete with material such as;char coal,common salt,G.I.Pipes,thimbles,nuts & bolts,digging of pits,G.I.wiring and 25x5mm.copper strips of required capacity conforming to BIS-3043-1987 latest with uptodate ammendments for above motors and other electrical equipments.
Supply and erection of floor/wall mounted power factor shunt capacitor conforming to BIS-2834-1986 latest with uptodate ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to Induction Motor individually of required KVAR according to H.P.of Motor offered including Siemens/Gloster/ICC make from Busbar chamber to capacitor and also including LT/LK/ Kilburn make ICTP.Switchesconforming to BIS-4064-1978 or latest with HRC fuses(Range to be specified by the tenderer).
Supply of standard make circular dial pressure gauge of suitable range of Fiebeg/Bourden/Precision make with all accessories such as;stop cock,copper tubing etc.conforming to BIS-3624-1987 latest with uptodate amme
Laying of Column Assembly of 100mm.dia and common header 100mm.dia G.I.Pipe Confirmng to IS-1239 or pipe 4.80mm.thick conforming BIS-1978-82 considering site requirement duly flanged at every 3 Metre length with flanges conforming to BIS-6392-1971(Table-17) including tapers,flanges,rubber gaskets 3mm.thick as as per BIS-2712-1978,nuts & bolts as per 1364-1983 and specials upto collection tank as per directions of Engineer-in-Charge /as per layout approved by the Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total pressure indicated in item No.1(xii).The size of column assembly shall be supplied by the tenderers. NOTE:- Actual laying tobe done as per final drawings to be approved by the Engineer-in-Charge.
Erection of all equipments from S.No. 1 to 3 and 5 to 6 including cost of tees, bends,tapers and any other fittings required as per conditions and as per directions of the Engineer-in-Charge.
Providing horizental spindle, horizental/radial split casing/and suction ( backfull out arrangement) single/double/multistage centrifugal pump or combination of pumps, in series/paraller of recommended make such as BS/SABAR/LUBI/Calama/KSB/Crompton/SU/Johnston/Kirloskar/BE/Jyoti as per BIS-1520-1980 with upto date ammendment read with IS 9137-1978 or latest edition suitable for lifting water for under mentioned characterstics with bronze,impellers, priming funnels, casing ring and shaft sleaves of bronze, shaft of steel grade with cast iron casing coupled directly through a flexible coupling on a common CI/cast steel base plate (base plate to be from the manufacturer of the pumping set) to slipring/squirrel cage screen protected drip proof induction motor of kirloskar/BHEL/Crompton/NGEF/GEC/Siemen/Jyoti/BHEL/GEC/ABB conforing to BIS-325-1978 (latest with upto date amendments) It should be include the cost of bearing, nuts and bolts painting etc. and shall be suitable for operation as per data given below:-The pumping machinery shall be installed on properdised baseplate, which is to be from the principal manufacturer of pumping set. The foundation of the machinery should be designedandanchored properly.
Location of site :-The site is located at a distance of Kms.from Nurpur Road Railway Station.
The altitude of place in which :-Altitude of place is 460 Metres above Mean Sea Level. the Motor is intended to work
Type of current :-A.C.Three phase supply with frequency 50 cycles per second.
Rated Voltage :-415 Vvolts (+/-) 10%
Characterstics of water :-(a).Temperature = 20oC (f) PH =_____ (b).Turbidity =Upto 10NTU (g) Total solids____Mg/Litre ©. Hardness =__Mg/Litre(as CaCo3) (h). Others_____ (d).Alkalinity =__Mg/Litre(as CaCo3)
Depth of Well Assembly :- Metres.
L.W.L.in Collection Tank :-39.00 Metres
Maximum draw down :- Metres
Centre line level of Pump :- 35 Metres
Discharge level of highest point:-193.76 Metres
Nos.of Pumps required :-2 No.Pump.
Capacity :- 7.11 L.P.S.
Total head in Metres :- 184.36 Metres
Length of Rising Main :- 1275 Metres
Dia of Rising Main :-100 mm dia GI pipe
No.of working hours per day :-8.00 Hours.
Limits of pump operation :- ( - ) 15% ( + ) 10% of total head.
H.P.of Motor/Drive unit :-Required 135 H.P.of Pump at ( + ) 10% and ( - ) 15% of total head. BHP.with following margins/multiplying factor at duty point,whichever is higher. a).Upto 2 H.P. =1.5 (d) 10 to 20 H.P. =1.2 b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15 c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10
Test Run :-8 Hours continueously for 7 days.
Providing cast steel double flanged sluice valve of Kirloskar/Kilburn/IVC.Vfouress/Gled/BHEL/Leader make of size as per offered pump and class ASA-150 having one size higher to delivery size of pump and capable of withstanding nominal seat pressure of 21kgs/cms conforming to BS 1414/API-600. The size of valve shall be specified by the tenderer)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I./Cast steel double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump(size 100mm.dia and clasas ASA-150 and shall be suitable for withstanding nominal seat pressure of 21.00Kgs. Cm <2) conforming to BSA 1868/API-600. The size of valve shall be specified by the tenderer)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main i.e. 100mm & class ASA-150 shall be suitable for withstanding nominal seat pressure of 21.00kgs/Cm<2)
Providing and laying suitable size copper PVC.insulated armoured power 3.5 core cable conforming to BIS-1554-Part-I -1988 or latest with uptodate ammendments Siemen/Gloster/ICC make from Meter of HPSEB. to MCB/OCB & from OCB to Busbar Switch & Starter(One cable carrying all three phases) including all other elecric euipments /accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipers or trenches size and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.auithority shall have to be replaced by the tenderer free of cost.( The size of cable shall be specified by the tenderer)16mm square.
Providing and laying PVC jointless flat water proof cable 2.5mm square as per BIS-694-1990(Latest with uptodate ammendments) suitable for the pump set offered from OCB to Motor, Motor to Starter including all other electric equipment such as;thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipes or trenches under floor. The type & make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.authoirity. In case of non-acceptance by HPSEB authority, it shall have to be replace by the tenderer free of cost. The size of cable shall be specified by the tenderer. (10mm sqr.
Providing and laying double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as char coal salt GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring and 25x5mm copper stripsw of required capacity conforming to BIS 3043-1987 latest with update date amendments for above motors and other electrical equipments.
Supply and erection of floor/wall mounted power factor shunt capacitor conforming to BIS-2834-1986 latest with uptodate ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to Induction Motor individually of required KVAR according to H.P.of Motor offered including Siemens/Gloster/ICC make from Busbar chamber to capacitor and also including LT/LK/Kilburn make ICTP.Switchesconforming to BIS-4064-1978 or latest with HRC fuses. ( Range to be specified by the tenderer) (7x2=14KVAR)
Supply of standard make circular dial pressure gauge of suitable range of Fiebeg/Bourden/Precision make with all accessories such as;stop cock,copper tubing etc.conforming to BIS-3624-1987 latest with uptodate ammendments.
Laying and fixing of GI pipe of Column Assembly 80mm.dia and common header 100 mm.dia G.I.Pipe 4mm.thick conforming BIS-1978-82 considering site requirement duly flanged at every 3 Metre length with flanges conforming to BIS-6392-1971(Table-5) including tapers,flanges,rubber gaskets 3mm.thick as as per BIS-2712-1978,nuts & bolts as per 1364-1983 and specials upto collection tank as per directions of Engineer-in-Charge /as per layout approved by the Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total pressure indicated in item No.1(xii). (The size of pipe shall be suppling by the tenderers)
Suction pipe 80 mm dia GI medium duly flanged T-5
Delivery pipe 80 mm dia duly flanged T-5
Common header 125 mm dia GI medium thick T-5
Erection of all equipments from S.No. 8 to 10 and 12 to 13 including cost of tees, bends,tapers and any other fittings required as per conditions and as per directions of the Engineer-in-Charge.
M/S POLLY PHASE NEW ENGINEERING
A.K. Traders
sadeep kumar
HYDRO ENGINEERING COMPANY
Vijay Kumar C/O Vasudeva Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .