Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.2 LAccepted-AOC | 1 | Accepted-AOC AWARDED | |
| 2 | 2₹5.6 L+₹46,536 (8.98%)Rejected-Finance CHIEF ENGINEER DRAINAGE CUM MINING AND GEOLOGY 2 | 2 | Rejected-Finance high bidder |
Tender Value
₹5.0 L
EMD Value
₹9,934
Closing Date
6 Nov 2024, 9:00 amClosed
Executive Engineer
Faridkot Canal and Ground water Division, Faridkot
Estimate for repair and renovation of Gauge Reader Hut at R.D. 104500 of Abohar Branch.
2024_WR_129005_1
Estimate for repair and renovation of Gauge Reader Hut at R.D. 104500 of Abohar Branch.
Open Tender
Civil Works - Canal
Item Rate
60 days
Jagroan
Pre Qualification Details
2 documents required · 2 mandatory
₹500
Yes
₹9,934
Yes
Faridkot
18 Dec 2024
23 Oct 2024
6 Nov 2024
23 Oct 2024
6 Nov 2024
23 Oct 2024
29 Oct 2024
Amount
Dismantling brick work tile, masonry or tile lining in cement.
Dismantling Mud roofing with wooden planks laid over battens.
Dismantling Cement concrete plain 1:3:6 mix
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation.
Cement concrete 1:3:6 with stone ballast or shingle mixing by manual means
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level.
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels.
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Cold twisted deformed (Ribbed/Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 for R.C.C. works, where not including in the complete rate of R.C.C. including bending and placing in position complete in all respect.
12.5 mm thick cement plaster 1:3
20mm thick cement plaster 1:3 in two coat work
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Finishing walls with acrylic smooth exterior paint of required shade with two coats applied @ 1.67 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc.
Conglomerate floor 50mm thick cement concrete rate 1:2:4 on 100mm thick cement concrete 1:8:16 and Stone aggregate 40mm gauge and 100mm sand filling
Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock- notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete. Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter
Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. Panelled, glazed or glazed and panelled , 35mm thick.
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 3mm thick up to 0.40 sqm area
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt). For shutter area above 0.50 sqm
Providing and fixing helical door spring 150mm (superior quality) including necessary screws, complete with Iron helical spring
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. (a) With special quality paint
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. SDR 11 CPVC pipes & fittings 20mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 75 mm
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock long nose/ long body without flange.
Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification (IS:1729) of approved make (to the approval of Engineer-in-charge) of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. minimum depth of water should be 150mm with a minimum seal 50mm. With 75mm i/d outlet deep seal
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Double Layer Tanks
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball , 25mm i/d
Wiring Light point in PVC insulated copper conductor single core FLRS cable (I.S.I. marked) overall 1.5 sqmm 1100 volts Grade complete
Wiring 6Amp. Plug control comprising wall socket point. Wall socket point in PVC insulated copper conductor single core FLRS cable (I.S.I. marked) overall 1.5 sqmm 1100 volts Grade complete
Supply & erection of Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory,transportation to site and vice versa etc. complete in all respect (a) Boring with 150mm id Housing Pipe . As per CSR Item No 28.72 (a)
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – incharge. (a) 100 mm nominal size dia. As per CSR Item No 28.92 (a)
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge . (a) 100 mm nominal size dia. As per CSR Item No 28.93 (a)
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. As per CSR Item No 28.80 a (100 mm dia)
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect . As per CSR Item No 28.77
Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP- Mpa) of Overall length 7 metre, with planting depth 1.25 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2) and base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia.
Any other Item
MANINDER PAL SINGH (BID ID -595357)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .