Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹44.2 L+₹1.4 L (3.31%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹45.5 L+₹2.7 L (6.25%)Rejected-AOC KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹46.4 L+₹3.7 L (8.56%)Rejected-AOC 33 NATIONAL CHAMBERS NEAR CITY GOLD CINEMA ASHRAM ROAD AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹47.6 L+₹4.8 L (11.3%)Rejected-AOC PLOT NO P PARASNAGAR NR SBI BANK NARSANG TEKRI PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹81,000
Closing Date
16 Jan 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
ADDN/ALT TO CGOM AT DHQ1, PORBANDAR FOR PROTECTION ALONG THE ROOF TOP AND ACCESSIBILITY UNDER GE I CG PORBANDAR
2022_MES_571380_1
8829
Open Tender
Civil Works
Item Rate
180 days
PORBANDAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
PORBANDAR
₹81,000
Yes
8 Apr 2023
26 Dec 2022
17 Jan 2023
26 Dec 2022
16 Jan 2023
9 Jan 2023
Amount
SCHEDULE 'A'
M&L Reinforced cement concrete 1:1.5:3 type A1 (using 20 mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M&L Reinforced cement concrete 1:1.5:3 type A1 (using 20 mm graded aggregate) in slab supported on walls, complete all as specified and as directed.
Use & waste of work to sides and soffits of floor or roof beams, beam haunching,lintel etc complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200 mm thick in sloping complete all as specified and directed.
S&F Mild steel TMT(CRS) bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips.complete all as specified and directed.
All as per item No. above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders -ditto-
M&L for cement concrete (1:2:4), type B-1, using 20mm graded mechanically crushed stone aggregate as in coping, bed block benching, kerbs, mud stop, rounded or chamferred on edges including necessary form work/moulds complete all as specified and as directed.
M & L Porbandar stone masonry, well bonded, bedded and solidly hearted built in CM 1:4 all as specified and as directed by Engineer-in-charge.
Taking down cement plaster includiing raking out joints hacking for key and scrubbing down with water complete, all as specified and directed by Engiiner-in-Charge
M&L for rendering 15 mm thick on fair face of brick work or concrete surfaces in CM 1:4 finished even and smooth wiithout using extra cement. complete all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining including 15 mm thick rendering in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture pigements to match the shade of granite all as specified and directed.
S&F for stainless steel of Grade 316 as in framed work as in doors or gates, ladder and railing of angles or other section with gusset plates, rails, braces, sheet sheeting for covering etc, complete drilled for fixing of door and sheet etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings, running rails and guides and hanging, also fastening and fixing complete all as specified and directed.
S&F for Galvanised iron Framed work such as grills, gratings etc with ends of bars shouldered and/or revited, or forged into spike, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar work complete all as specified and as directed.
M & L for Sculpture work (Heritage stone art work) as in parapet wall, in units , as per the length and details shown for each unit, in the drawing, using sand stone of best quality (approved by GE), constructed over existing roof slab of the building, including polishing stone surfaces to natural colour, all as specified and directed by the Engineer-in-charge.
M & L for Non skid ceremic white tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 15 mm thick in CM 1:4 and pointed in white or coloured cement to match complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc incl removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 Kg/Sqm complete all as directed by Engr-in-Charge.
M&L for 40mm thick cement plain cement concrete type B-0, 1:2:4 (using 12.5 mm graded aggregate) complete all as specified and directed.
M&L for 20mm thick cement plaster in cement mortar 1:4 mixed with 2% of water proofing compound as in roof treatment when concreate is green complete all as specified and directed. Note :- shall be meahred and paid separately under respective item.
M&L for aPP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method.
Supply only water proofing compound (integral) all as specified & directed.
M&L preparation of old stone suface of any description, and applying two coats of malemine 1 K PU Polishing paint aplying with compresor spry machine etc complete all as specified & directed by Engr-in-Charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. all as per the manufacturers instructions, complete all as specified and directed by Engr-in-charge.
Taking down rain water pipe , eaves gutters, soil pipes,waste pipes (any size and pattern) including all fittings heads shoes bends swan necks etc
S&F 110mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including GI clamps of approved shape and size approved by GE
S&F 160mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including GI clamps of approved shape and size approved by GE
M&L preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of epoxy paint over a coat of red oxide primer etc complete all as specified & directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillars, etc complete all as specified and as directed.
Supply and fixing of Dust & Weather proof PVC Enclosure 4 Modules on wall of IP 55 and all as specified and directed.Make : C&S (Model No CG264400W) or equivalent in sintex/Havells.
Supply & fix modular switch 1 way, 16 Amps, 1 modular (ISI marked).complete all as specified and as directed.
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed.
M & L for submain wiring 2x 4 Sqmm + 1x 4 Sqmm earth wire using ISI marked 1.1 kV grade single core FRLSH flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25 mm size PVC conduits surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, all complete as specified and directed. Make: RR Kabel, Polycab, Havells, Finolex & PVC Conduit Make :Precision, Prince, Supreme NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC conduit shall be measured as one length complete all as specified and directed
Supply & Lay for XLPE insulated, armoured heavy duty electric cable with aluminium conductor of size 10 Sqmm X 4 Core, 1100 volts grade of cross-sectional area complete all as specified and directed. Make: Polycab/ Asian/ Gloster/Havells/KEI
Supply,and fixing MCB DB 08 way SPN, PC (Polycarbonate), IP 65 "Weather Proof" concealed/Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecteing the cables with proper thimbuls and all as specified and directed. Make Hensel (KV PC 8109 or equivalent in Hagers.
Supply and fixing for amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
SP 6 To 32 AMP
FP 32 Amps
Supply and Lay for 50/38 OD Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings laid in trenches/road/nallah or fixed along wall poles or laid under floor for the following dia (Excavation and earthwork shall be measured and paid separately) complete all as specified and as directed. Make: Rex/Poly/Geminie (i) Fixing accessories for pipe laying such as clamps and nut bolts are to be included in quoted rate.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil and including taking out of PCC cable cover and getting out complete all as specified and directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
M & L for Earthing complete with galvanized steel pipe electrode , 40mm bore, medium grade, 2.5 metre length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of aluminium strip 25*4 mm size galvanised iron strip 4 all as shown in electrical plate no. 2 of MES SSR part-1 to the earthing test point all as specified and indicated including testing on completion all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .