Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 58 667 SAPTHATHI BUILDING KONTHURUTHY THEVARA ERNAKULAM KERALA 682013 | ERNAKULAM | KERALA | 682013 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
4 Feb 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGM P and P
Assistant General Manager Projects and Planning PD Administration
CANTEEN ROOM ELECTRIFICATION IN FACT UC
2025_FACT_844183_1
3017/2024-2025/E30743
Open Tender
Miscellaneous Works
Item Rate
60 days
Udyogamandal
ATTACHED IN TERMS AND CONDITIONS
6 documents required · 6 mandatory
₹0
₹12,000
Yes
5 Feb 2025
14 Jan 2025
5 Feb 2025
14 Jan 2025
4 Feb 2025
14 Jan 2025
CANTEEN ROOM ELECTRIFICATION IN FACT-UC
Supply, erection, termination and servicing of single/double door 12 way, 3 Phase , 415 Volts MCB DB having the following specification: 1) 63A 4 pole isolator - 1 No. 2) 63A 4 pole RCCB with sensitivity of 30mA - 1 No 3) 32A single pole C type MCB-4 nos 4) 10A single pole B type MCB - 10 Nos 5) 6A single pole B type MCB - 10 Nos 5) 16A 2 pole MCB D type-6 nos All the remaining module spaces should be covered by dummy plates. DB shall be mounted on suitable MS frame. The frame shall be applied with one coat of epoxy primer followed by two coats of epoxy finish paint and shall be grouted (or welded to steel structures) to wall / tiled surface. Supply of DB with all required items and consumables are in the contractor's scope. Existing incomer cable shall be made use of.
Supply, erection, termination and servicing of single/double door 12way,VTPN 3 Phase,415 Volts Power Distribution board with MCCB incomer having the following specification: 1) 100A 4 pole MCCB-1 no 2) 100A 4 pole RCCB with sensitivity of 30mA-1 no 3) 32A 3 pole MCB D type-3 nos 4) 25A 3 pole MCB D type-6 no 5) 16A 3 pole MCB D type-3 nos All the remaining module spaces should be covered by dummy plates. DB shall be mounted on suitable MS frame coated. The frame applied with one coat of epoxy primer followed by two coats of epoxy finish paint and shall be grouted (or welded to steel structures) to wall / tiled surface. Supply of DB with all required items and consumables are in the contractor's scope.Existing incomer cable shall be made use of.
Supply, erection, termination and servicing of single/double door 12way,VTPN 3 Phase,415 Volts Power Distribution board with MCCB incomer having the following specification: 1) 100A 4 pole MCCB-1 no 2) 100A 4 pole RCCB with sensitivity of 30mA-1 no 3) 32A 3 pole MCB D type-3 nos 4) 25A 3 pole MCB D type-2 no 5) 16A 3 pole MCB D type-7 nos All the remaining module spaces should be covered by dummy plates. DB shall be mounted on suitable MS frame coated. The frame applied with one coat of epoxy primer followed by two coats of epoxy finish paint and shall be grouted (or welded to steel structures) to wall / tiled surface. Supply of DB with all required items and consumables are in the contractor's scope.Existing incomer cable of 4C x 35 sq.mm PVC-A-PVC shall be made use of.
Supply, erection, termination and servicing of single/double door 16 way, Single phase , 230 Volts MCB Lighting DB having the following specification: 1) 32A Double pole isolator - 1 No. 2) 32A double pole RCCB with sensitivity of 30mA -1 No 3) 16A single pole C type MCB - 4 Nos 4) 10A single pole B type MCB-4 5) 6A single pole B type MCB- 4 nos All the remaining module spaces should be covered by dummy plates LDB shall be fixed on suitable MS frame. The frame applied with one coat of epoxy primer followed by two coats of epoxy finish paint and shall be grouted (or welded to steel structures) to wall / tiled surface. Supply of all required items and consumables including LDB are in the contractor's scope.Existing incomer cable shall be made use of.
Supply, fabrication, painting and fixing of cable trays/supports of different dimensions using MS angles/ channels/ flats etc. by welding / grouting to steel structures/pillars/ walls etc. The fabricated cable tray/ supports shall be applied with one coat of epoxy primer followed by two coats of epoxy finish paint with sufficent preparation/ curing. Supply of MS items and all consumables / tools such as welding set with welding rods, gas cutting sets with gas, cleaning brush,paint, primer, thinner, painting brush, cement and sand for grouting work etc. are under Contractor's scope.
Supply,fixing and servicing of 20W LED tube fittings surface mounted with required clamps and/fasteners.(LED fittings shall be of philips/Luker/hawells/panasonic /crompton make)
Supply, installation and servicing of recess type 36W- 2ft x 2ft false ceiling type LED light with color temperature cool day light and including suspension rod/chain point wiring. The installation of lighting fixtures shall be on false ceiling,as per the drawings or as instructed by the engineer in charge. The scope shall include terminations of cables on lighting fixtures, fixing lamps and accesories. Supply of lamp including all required accessories such as clamps, hanging rods/chains, bolts, nuts, screws, washers, copper flexible cable,PVC box for fixing ceiling rose, PVC Junction boxes(2/3/4 way) etc. for properly fixing the light fitting on to the ceiling wherever required are under the scope of contractor. The wiring shall be above ceiling. Preparation and fixing of concealed ceiling roses/junction boxes, drawing earth wires of 1.0 sq.mm flexible copper cable of green colour pvc for metal body earthing , connecting, testing and commissioning are under contractor's scope. For a point wiring, pipe length greater than 10 metres shall be considered as one and a half point. (LED fittings shall be of Philips/Luker/Hawells/Halonix/Bajaj/Crompton/Jaguar/Syska/Panasonic make)
Supply, fixing and servicing of industrial wall mall mounting fans 600 mm span, 230V on walls/beams. All the required fasteners/ acessories / fans are under the scope of contractor.Fans shall be of Almonard/ Usha/Crompton/Havells/Atomberg/ Orient Electric/Luker/V guard make
Supply, Fixing and servicing of Ex. Fan 450mm(Almonard/Crompton greaves/bajaj). All acessories and fasteners required for the completion of work are in the scope of contractor.
Supply of DOL Motor Starter 3 Phase for 415VAC, 50Hz with thermal bi-metallic Relay of range 1.5 to 2.5 A, Start-Stop Push Button on the cover, with 415V operating coil, in sheet-steel enclosure.
Supply of DOL Motor Starter 3 Phase, 415VAC 50Hz with thermal bi-metallic Relay of range 3 to 6 A, Start-Stop Push Button on the cover, with 415V operating coil, in sheet-steel enclosure.
Supply of DOL Motor Starter 3 Phase, 415VAC 50Hz with thermal bi-metallic Relay of range 6 to 10 A, Start-Stop Push Button on the cover, with 415V operating coil, in sheet-steel enclosure.
Supply of DOL Motor Starter 3 Phase, 415VAC 50Hz with thermal bi-metallic Relay of range 20 to 32 A, Start-Stop Push Button on the cover, with 415V operating coil, in sheet-steel enclosure.
Supply of DOL Motor Starter 3 Phase, 415VAC 50Hz with thermal bi-metallic Relay of range 28 to 42 A, Start-Stop Push Button on the cover, with 415V operating coil, in sheet-steel enclosure.
Fixing of DOL starter. Scope of work includes: Fixing of DOL by mounting on wall using suitable MS frame. The frame shall be applied with one coat of epoxy primer followed by two coats of epoxy finish paint and shall be grouted (or welded to steel structures) to wall / tiled surface.
Open cable point wiring (4x4sq.mm armoured copper) with individual control for 20 A, 415volts, TPN industrial type socket outlet,with 4 pole and earth, metal enclosed plug top along with 20 amps, TP, MCB,in sheet enclosure, with chained metal cover for the socket outlet . All the materials required for wiring like Industrial power socket, metal box, MCB and body earthing of metal clad items, armoured cable, glands, connecting, testing and commissioning shall be in the scope of contractor. For a point wiring, if cable length greater than 10 metres shall be considered as one and a half point.
Open cable point wiring (3x2.5sq.mm armoured copper) with individual control for 16 A, 230V metallic Industrial power sockets with control MCB. All the materials required for wiring like Industrial power socket, metal box, armoured cable, glands, MCB and body earthing of metal clad items, connecting, testing and commissioning shall be in the scope of contractor. For a point wiring, if cable length greater than 10 metres shall be considered as one and a half point.
Supply, laying and termination of earth conductor of 16 sq. mm single core copper multi stranded green colour cable from Power DB along the cable tray by properly clamping with aluminium clamps/saddles, with connection to aluminium 25x3mm strips of 20cm length. The cable shall be fastened to aluminium strip with suitable nuts,bolts and washers after lugging. Supply of all items including cable, lugs,nuts, washers, bolts etc. are under contractor's scope
Supply, laying and termination of earth conductor of 2.5 to 6 sq.mm single core multistranded copper green colour cable from aluminium strips to the starters/switch board of individual equipment for earthing individual equipment. The cables shall be fastened to aluminium strip with suitable nuts,bolts and washers after lugging. Supply of all items including cable, lugs,nuts, washers, bolts etc. are under contractor's scope
Supply and fixing of aluminium strip of size 25 x 3 mm of 20cm length to cable tray/structures. Supply of all items including strips, lugs,nuts, washers, bolts etc. are under contractor's scope
Supply of 4Cx35 sq.mm PVC/XLPE aluminium armoured Cable
Laying and clamping of cables of size 4Cx35 sq.mm PVC/XLPE aluminium armoured Cable as point wiring, from load centre to DB/starters. Scope of work includes : 1) Laying cable through MS cable trays/walls by properly clamping the cables at distance not exceedding 50 cm with aluminium clamps/ GI metal saddles. 2) Required holes through walls should be made by the contractor All the materials including clamps, fasteners etc. required for this work are under the scope of contractor.
Glanding and termination of armoured cables of size 4Cx35 sq.mm using single/double compression glands. All the materials including cable glands of required sizes, lugs, fasteners etc. required for this work is under the scope of contractor.
Supply of 3Cx2.5 sq.mm PVC/XLPE copper armoured Cable
Laying and clamping of cables of size 3Cx2.5 sq.mm PVC/XLPE copper armoured Cable as point wiring, from DB to starters/switch boards. Scope of work includes : 1) Laying cable through MS cable trays/walls by properly clamping the cables at distance not exceedding 50 cm with aluminium clamps/ GI metal saddles. 2) Required holes through walls should be made by the contractor All the materials including clamps, fasteners etc. required for this work are under the scope of contractor.
Glanding and termination of armoured cables of size 3Cx2.5 sq.mm using single/double compression glands. All the materials including cable glands of required sizes, lugs, fasteners etc. required for this work is under the scope of contractor.
Supply of 3Cx6 sq.mm PVC/XLPE copper armoured Cable
Laying and clamping of cabbles upto 3Cx6 sq.mm PVC/XLPE copper armoured Cable as point wiring, from DB to starters/switch boards. Scope of work includes : 1) Laying cable through MS cable trays/walls by properly clamping the cables at distance not exceedding 50 cm with aluminium clamps/ GI metal saddles. 2) Required holes through walls should be made by the contractor All the materials including clamps, fasteners etc. required for this work are under the scope of contractor.
Glanding and termination of armoured cables of size 3C x 6 sq.mm using single/double compression glands. All the materials including cable glands of required sizes, lugs, fasteners etc. required for this work is under the scope of contractor.
Open Pipe Point wiring through inside false ceiling / wall with individual control for light / fan/ bell/ 6A modular plug sockets separately mounted , using flexible copper cable of 1.5 sq.mm for control and 2.5 sq.mm for neutral connection through 20mm PVC conduit(ivory colour) using metal saddles with spacing not exceeding 50 cm, as per relevant drawings or instructions from FACT engineer. The wiring shall be along beam/wall / column / ceiling, preparation and fixing of concealed modular switch boards, switches, cover plates,dummy plates etc, fixing ceiling roses on suitable junction boxes, modular step type regulators for fans, drawing earth wires of 1.0 sq.mm flexible copper cable of green colour pvc for metal body earthing , connecting, testing and commissioning. The switch boards wiring should be kept conceiled if required, for maximum 1 metre length for that portion that goes under the tiled portion and switch boards should be mouted on the surface of tiles. For a point wiring, pipe length greater than 10 metres shall be considered as one and a half point and 6A plug points shall be considered as half point wiring. All the materials required for wiring such as copper flexible cable, metallic modular switch boards, modular switches, cover plate, dummy plates, PVC box for fixing ceiling rose, PVC Junction boxes(2/3/4 way), Step type regulators etc. shall be in the scope of contractor.
Open point wiring from DB to switch board using 2.5 sq. mm copper cable through 20mm PVC conduit(ivory colour) using metal saddles with spacing not exceeding 50cm, as per relevant drawings or instruction from FACT engineer. The wiring shall be along beam/wall/coloumn/ceiling/cable trays. Preparation and fixing of suitable junction boxes if required, drawing earth wires of 2.5 sq.mm flexibe copper cable of green colour pvc for metal body earthing, connecting, testing and commissioning are under the scope of contractor. For a point wiring, 10 metres shall be considered as one point and pipe length greater than 10 metres shall be considered as one and a half. All the materials required for wiring such as copper flexible cable, PVC junction boxes(2/3/4 way), etc. shall be in the scope of the contractor.
Concealed Pipe Point wiring through wall with individual control for light / fan/ bell/ 6A modular plug sockets separately mounted , using flexible copper cable of 1.5 sq.mm for control and 2.5 sq.mm for neutral connection through 20mm PVC conduit, as per relevant drawings or instructions from FACT engineer. The wiring shall be along wall. Preparation and fixing of concealed modular switch boards, switches, cover plates,dummy plates etc, fixing ceiling roses on suitable junction boxes, modular step type regulators for fans, drawing earth wires of 1.0 sq.mm flexible copper cable of green colour pvc for metal body earthing , connecting, testing and commissioning. For a point wiring, pipe length greater than 10 metres shall be considered as one and a half point and 6A plug points shall be considered as half point wiring. All the materials required for wiring such as copper flexible cable, metallic modular switch boards, modular switches, cover plate, dummy plates, PVC box for fixing ceiling rose, PVC Junction boxes(2/3/4 way), Step type regulators etc. shall be in the scope of contractor.
Open cable point wiring (3x2.5sq.mm copper) with individual control for 16A power sockets. The switch boards wiring should be kept conceiled if required, for maximum 1 metre length for that portion that goes under the tiled portion and switch boards should be mouted on the surface of tiles.All the materials required for wiring like flush type 16A, 5 in 1 switches and sockets separatly fixed on 6"x4" metal boxes having 75mm depth,glands etc. and body earthing of metal clad items, connecting, testing and commissioning. For a point wiring, if cable length greater than 10 metres shall be considered as one and a half point. Required cables shall be supplied by FACT.
Suppy of labor for dismantling/disconnection of existing cables/fans/lights/DBs/switchboards etc. from walls/structures/ trays/mountings/distribution boards and storing the dismantled items in proper order as instructed by the engineer in charge. Labor supply shall be on eight hour shift basis.
Supply of recess type 36W- 2ft x 2ft false ceiling type LED light with color temperature cool day light including suspension rod/chain. (LED fittings shall be of Philips/Luker/Hawells/Halonix/Bajaj/Crompton/Jaguar/Syska make)
Supply of industrial wall mall mounting fans 600 mm span, 230V on walls/beams. All the required fasteners/ acessories / fans are under the scope of contractor. Fans shall be of Almonard/ Usha/Crompton/Havells/Atomberg/Orient Electric/Luker/V guard make
Supply of 400mm remote controlled BLDC wall fan. The service value of wall fan shall be higher Than 5.5 CMM/Watts.(Refer BEE Guide lines for service value and Star Ratings) Approved Makes : Almonard/ Usha/Crompton/Havells/Atomberg/Orient Electric /Luker/V guard make
Supply of 100Amps 4 pole MCCB in in sheet steel enclosure.
Supply of Ex. Fan 450mm(Almonard/Crompton greaves/bajaj).
Supply of 32Amps, 4P, 415V, MCB in sheet steel enclosure.
Supply of 16Amps, 2P, MCB in sheet steel enclosure.
Supply of 32Amps, 2P, ELCB in sheet steel enclosure.
Supply of Fuse switch unit, 63 Amps, at 415V 50HZ(AC-23)in sheet steel enclosue with operating handle and fuses.
Supply of Fuse switch unit, 125 Amps, at 415V 50HZ(AC-23)in sheet steel enclosue with operating handle and fuses.
Nev Tech (BID ID -3166014)
V V ELECTRICALS (BID ID -3165631)
LAMOS TECHNOLOGY SOLUTIONS PVT LTD (BID ID -3160394)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .